Rural Engineering Department Tender
... More
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of etender.up.nic.in - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Rural Engineering Department Tender
Civil And Construction
Civil Works Others
Eprocure
Opening Date7 Jan 2025
Closing Date10 Feb 2025
Tender Amount₹ 2,06,85,000
Costs
EMD
₹ 4,14,000Document Cost
₹ 2,714Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_REDUP_991038_1Tender No
1073 /RED/Nivida-Spn/2024-25 dt 26-12-2024Tender Authority
Rural Engineering Department ViewPurchaser Address
-Website
http://http://upred.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Brick Work with common burnt clay F.P.S (non modular) brick of class designation 7.5 in super structure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) As per D.S.R 6.4.2
450.42
6630
2986428.73
... More
Washed stone grit plaster on exterior walls height upto 10 metre above ground level, in twolayers, under layer 12 mm cement plaster 1:4 (1 cement : 4 coarse sand ), furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 2 Kg of cement per square metre, top layer 15 mm cement plaster 1:1/ 2:2 (1 cement: 1/2 coarse sand : 2 stone chipping 10 mm nominal size), in panels with groove all around as per approved pattern, including scrubbing and washing the top layer with brushes and water to expose the stone chippings ,complete as per pecification and direction of Engineer-in-charge (payment for
providing grooves shall be made separately).As per DSR 13.72
5284.25
846
4471902.25
... More
12 mm cement plaster of mix 1:6 (1 cement: 6 fine sand) D.S.R 13.1.2
28.8
242
6990.34
... More
1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural
sources : 3 graded stone aggregate 20 mm nominal size de
rived from natural sources)As per D.S.R 5.1.2
214.82
6586
1414909.78
... More
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).As per D.S.R 5.3
94.29
8377
789915.42
... More
Centering and shuttering including strutting, propping etc. and removal of form Foundations, footings, bases of columns, etc. for mass concrete As per D.S.R 5.9.1
1983.73
285
566434.26
... More
Centering and shuttering including strutting, propping etc. and removal of form Lintels, beams, plinth beams, girders, bressumers and cantileversAs per D.S.R 5.9.5
790.76
536
424005.51
... More
Thermo-Mechanically Treated bars work such as in reinforced concreted or reinforced brick work (when not included in overall rates) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage.As DSR Each5.22.6
26794.65
78
2104183.86
... More
Finishing walls with Acrylic Smooth exterior paint of required shade : 13.46.1 New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm).As DSR NO13.46.1
93.27
116
10907.01
... More
Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth completeAs DSR NO13.26
93.27
191
17840.69
... More
Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster
including disposal of rubbish to the dumping ground within 50 metres lead.As DSR NO15.56
926
39
36845.54
... More
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.As DSR NO 15.7.4
160.25
1500
240391.03
... More
Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead As DSR NO 15.18
557.4
4
2290.91
... More
Steel work in built up tubular (round, square or rectangular hollow tubes etc.)
trusses etc., including cutting, hoisting, fixing in position and applying a priming
coat of approved steel primer, including welding and bolted with special shaped
washers etc. complete.
10.16.1 Hot finished welded type tubes As DSR NO 10.16.1
13579.02
141
1922110.28
... More
Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufactureAs DSR NO 13.48.3
527.66
124
65582.99
... More
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the rchitectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. 11.56.1 Polished Granite stone slab colour of Black, Cherry/Ruby Red or equivalentAs DSR NO 11.56.1
263.75
3262
860601.81
... More
1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) DSR NO 4.1.3
18
5736
103258.44
... More
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.DSR NO1.10.1
3
800
2402.52
... More
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. DSR NO1.14.2
85
216
18443.3
... More
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as requiredDSR NO1.14.3
55
263
14494.15
... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. DSR NO1.24.1 5/6 A switch
8
81
650.16
... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. DSR NO1.24.2 2 way 5/6 A switch
3
116
350.31
... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. DSR NO1.24.3 15/16 A switch
4
123
492.32
... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. DSR NO1.24.4 3 pin 5/6 A socket outlet
10
96
962.6
... More
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. DSR NO 1.25
1
291
291.14
... More
Supplying and fixing following size/ modules, Gl box along with modular base & cover plate for modular switches in recess etc. as required. DSR NO 1.27.1
2
235
470.24
... More
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. DSR NO 2.10
10
201
2019.8
... More
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of
insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc.complete as required.AS DSR 19.1
1
2153
2153.97
... More
Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement: 3 coarse sand 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. Above 4.50 Mt .and upto 6.50 Mt. DSR 11.3.1
2
4040
8080.94
... More
Supply and fixing of LED Tube Light with batten suitable for up
to 1 X 22 watt LED tube light complete including tube etc on
surface complete in all respect. As per PWD SOR 1413 (A) CAT-AA
4
1100
4400
... More
Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 90 Watt. Confirming to IP 65 and above Protection complete in all respect CAT- AAA AS PED SOR 1423
12
8070
96840
... More
Supply and fixingof recess mountinground Ceillingcutout 160 mm height55 mm 18 Watt LED Down LighterhavingPowder coated die cast aluminiumhousing with heat sink, diffuser/ Reflector and driver set complete in all respect PWD SOR 1403 CAT- AA
20
1750
35000
... More
Supply and fixingof recess/ Surface/ Pendent mountinground 12 to 15 Watt LED Down Lighter havingPowder coated die cast aluminiumhousing with heat sink, diffuser/Reflector and driver set complete in all respect. As PWD SOR 1402
CAT- AA
50
1590
79500
... More
Supply & Fixing of sign board of size 1.20X0.90 Mtr. With M.S. Sheet of 16BG made of angle iron post 2 Nos. of 1.20 Mtr. In horizontal and 2.75mts. In vertical of size 40X40X6mm & flat Iron for cross 02 Each 40X6mm with complete letter writing as per drawing (Rate sanctioned by SE RED Bly.)
1
5000
5000
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements