Rural Engineering Department Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Rural Engineering Department Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date10 Jan 2025
Closing Date16 Jan 2025
Tender Amount₹ 11,44,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III)derived from natural sources : 3 graded stone aggregate 20 mm nominal sizederived from natural sources). Above Plinth Level. As per Code No-5.3

21.97

8456

185778.32

... More
Centering and shuttering including stutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access plateform. As per DSR Code No- 5.9.3

107.95

681

73513.95

... More
Steel reinforcement for R.C.C. work ready to use "cut and bend" rebars of approved make from factory/workshop to construction site including placing in position and binding all complete in Thermo-Mechanically Treated bars of grade Fe-500D or more. As per Code No.- 5.22 B.1

16.91

7300

123443

... More
Brick work with common burnt clay F.P.S. (non modular) bricks of Class designation 7.5 in super structure above plinth level upto floor V level in all shapes and sizes in cement mortar 1:6 ( 1 cement : 6 coarse sand ). As per Code No 6.4.2

34.92

6692

233677.95

... More
12 mm thick cement plaster of mix 1:6 ( 1 cement : 6 fine sand ) As per Code No 13.1.2

343.41

245

84135.45

... More
Providing and applying white cement based putty of average thickness 1 mm of approved brand and manufacturer,over the plasterd wall surface even and smooth surface. As per Code No-13.80

343.41

114

39148.74

... More
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm as per Code No-11.41.2

122.15

1141

139373.15

... More
Finishing walls with Acrylic Smooth exterior paint of required shade: New work (Two or more coats applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) As per Code No-13.46.1 Two Coats

148.88

118

17567.84

... More
Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre. (Interior) As per Code No-13.41.1 Two Coats

307.57

136

41829.52

... More
Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge. M.S. Angle 35x35x5 for door frames As per Code No. 10.31

140.4

95

13338

... More
Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, i/c applying a priming coat of approved steel primer. Using flats 36x6 mm for diagonal braces and central cross piece As per Code 10.5.2

14.04

4089

57409.56

... More
Painting on G.S. sheet with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :New work (two or more coats) including a coat of approved steel primer but excluding a coat of mordant solution DSR Code No.13.53.1

31.59

132

4169.88

... More
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. DSR-22 E&M Code no. 1.10.1

10

778

7780

... More
Supplying and fixing brass batten/ angle holder including connection etc. as required. DSR-22 E&M Code no. 1.34

10

100

1000

... More
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole. DSR-22 E&M Code no. 2.10.1

3

196

588

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire. DSR-22 E&M Code no. 1.14.1

30

178

5340

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire. DSR-22 E&M Code no. 1.14.2

15

211

3165

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. DSR-22 E&M Code no. 1.31

4

449

1796

... More
Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.As per DSR Code No. 10.18

8

169

1352

... More
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. DSR-22 E&M Code no. 1.25

8

383

3064

... More
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. 4 way (4 + 12), Double door. DSR-22 E&M Code no. 2.4.1

1

3139

3139

... More
Same as item No 1 but for Plug point . 134 (C)

6

335

2010

... More
Supply and fixing of Power pluge . 1139 (A)

2

625

1250

... More
Providing & fixing PVC pipes conforming to IS make workinh pressure 6 Kg/cm² including testing, labour, T&P and all complete fittings. 75mm dia As per Code No.12.41.1

10

182

1820

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. :Concealed work, including cutting chases and making good the walls etc. 20mm dia nominal dia pipes As per Code No.18.8.2

10

395

3950

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. :Concealed work, including cutting chases and making good the walls etc. 15mm dia nominal dia pipes As per Code No.18.8.1

15

365

5475

... More
Providing and fixing white vetreous china laboratory sink with Cl brackets, CP brass chain with rubber plug, 40 mm CP brass waste and 40 mm CP brass trap with necessary CP brass unions complete, i/c painting of fittings and brackets, cutting and making good the walls wherever required. Size 600x450x200 mm bowl depth 200 mm. As per Code No.17.11

2

4840

9680

... More
Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. Semi rigid pipe (a) 32mm dia As per Code No.17.28.1.1

2

76

152

... More
Providing & fixing CP brass bib cock of approved quality conforming to IS 8931 (a) 15mm nominal bore As per Code No.18.49.1

2

372

744

... More
Providing and placing on terrace (at all floor levels) polyethylene water storage tank of approved brand and manufacture with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. As per Code No.18.48

500

8

4000

... More
Supply and fixing of round jali125 mm dia i/c all complete

2

40

80



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.