Rail Vikas Nigam Limited Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Rail Vikas Nigam Limited - RVNL Tender

Goods
Telecommunication Services
Ireps
Opening Date8 Jul 2024
Closing Date30 Jul 2024
Tender Amount₹ 2,61,51,249.5 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
"Horizontal direction drilling/boring without damage of surface of road /Track formation. The bore shall be 150mm dia & shall be at the proper depth as per site conditions decided by Engineer -in-charge . The 4 ground level shall be considered ignoring the bankheight of the bank of the road. The length of the bore shall be minimum 4 Mtrs. long. This include insertion of different dia DWC pipe/GI/HDPE pipes coupling etc. as perdifrection of Egineer In charge. Note: The cost of pipe is not included in this item. Contractor shall provide all material required for boring and adequate nos. of labours for proper laying of cables into the bore. Cable shall be laid cautiously so that it should not get damage due to rough handling & pressure on cable."

4000

1565

6260000

... More
Excavation trench 0.35 M wide 1.2 M deep in all categories of soils such as black cotton/ hard / 5 murram/hardy soft rock . Filling th trench with earth to the level of surrounding ground after laying cables.NOTE: Where digging of trench as per specified depth is not possible, the depth can be reduced with the approval of the engineer in charge and the payment shall be made proportionately

3

131928

395784

... More
"Supply of Permananently lubricated HDPE pipe 40 / 33 mm dia. As per RDSO specification no. 6 RDSO/SPN/TC/45/ 2013 Rev 2.0 or latest RDSO specification if any; suitable for armoured 24 fibre OFC cable including its accessories like plastic coupler, end plug, cable sealing plug and end cap etc as required for the OFC system based on survey report."

12.5

84133

1051662.5

... More
Blowing of armoured Optical Fiber Cable into duct by using blowing machine and associated works 8 .Before blowing the duct integrity shall be tested .If any defect shall be found during duct integrity test , the entire length of HDPE duct from one chamber to another chamber chamber is to be replaced by Contractor at free of cost .

12

17129

205548

... More
Supply and installation of OFC cable joint enclosure as per TEC No. G/OJC-01/03 Jan 99 or latest RDSO specification and splicing of optical fibre cables ( 24 Fibre) and testing.

12

17428

209136

... More
Supply and installation of rack mounted 24 fIbre Fibre Distribution Management System part no FMS - 1U 24 FS 24 FP Raychem make including 24 Nos 0.2 db SC/PC adaptors and 24 Numbers. 900 micron 1.5 meter SCPC Pigtails RDSO Specification no. : RDSO/SPN/TC/037-2000(Rev.3) or latest.

3

36958

110874

... More
Supply and jointing of Quad cables with theromoshrinkable jointing kits

10

6797

67970

... More
Supply of Switch board cable 10 pair for indoor wiring.

0.5

-

16911.5

... More
Laying of signaling / power / telecom / quad/OFC cable of various sizes in trench and pipes.

12

7508

90096

... More
Placing of half round ( Split DWC ) pipe over the laid cable in open trenches

1.5

4871

7306.5

... More
Supply and Fixing of 20 pair CTB and termination of quad/ jelly filled cable.

6

6064

36384

... More
Testing of point to point insulation / continuity test for all laid out cables, Measuring Parameters and preparing the records

1

70932

70932

... More
Supply and fixing of RCC cable route marker as per Drg.No.SK/ 12/10 with engraving of Signal/Telecom cable one side and Zonal Rly on other side as per Railway Practice and painting on both sides of marker with numbering with black paint (Colour of the cable route marker paint and numbering may be 17 changed/decided by the RVNL Site incharge). The markers should be fixed for a maximum of 30 mtrs to locate the Signaling/Telecom cable path and the marker should be visible about one feet above the ground for the clear visibility, the remaining portion of marker should be buried in the ground. Whererver track crossing are available, RCC markers are to be provided on both sides of the track for easy identification. All required materials (Supply, painting, transportation to site and fixing) are to be aranged by the Contractor

100

1446

144600

... More
Supply of SPLIT DWC pipe of size 200 mm outer dia & 175 mm inner dia.

1500

394

591000

... More
Excavation for Jointing pit and provision of joint chamber of 1.2 mtr dia of 60 cm height with 2 piece 19 cover on top and bottom cover with holes for drainage ( reinforcement drawing will be as per technical specification ) .This includes water cooling of chamber , backfilling and ramming of trench after laying and consolidated of soil as well as disposal of soil as per plan as advised by site engineer.

6

6998

41988

... More
Excavation of cable trench of 1 m. depth & 300 mm. wide across the track crossing, road crossing, level crossing, platform & refilling.

1

93526

93526

... More
Laying HDPE duct in already made trenches and through DWC/GI/RCC pipes wherever necessary

4

13503

54012

... More
"Communication Server as per Clause 5 and 6 of RDSO/SPN/TC/99/2012 Ver.3.0 or latest. Communication server block shall be provided with 1+1 or 1:1 redundancy. (Inspection agency:-RDSO) "

1

2082384

2082384

... More
"Network Management Server as per Clause 5 and 8 of RDSO/SPN/TC/99/2012 Ver.3.0 or latest. (Inspection agency:-RDSO)"

1

495184

495184

... More
"Voice Recording Server as per Clause 5 and 7 of RDSO/SPN/TC/99/2012 Ver.3.0 or latest. (Inspection agency:-RDSO) "

1

1270607

1270607

... More
"Event Notification Gateway as per clause 12.3 of RDSO/SPN/TC/99/2012 Ver.3.0 or latest. (Inspection agency:-RDSO)"

1

291534

291534

... More
"The Portable Maintenance Terminal As per clause 8.7 and 8.9 of RDSO/SPN/TC/99/2012 Rev.2 or latest. (Inspection agency:-RDSO)"

1

52942

52942

... More
"Desktop Client PC As per clause 8.7 and 8.8 of RDSO/SPN/TC/99/2012 Ver.3.0 or latest. (Inspection agency:-RDSO) "

1

60001

60001

... More
"Supply of Controller Console (customized integrated as single unit) as per clause 9 of RDSO/SPN/TC/99/2012 Rev.2 or latest. (Inspection agency:-RDSO) "

5

362335

1811675

... More
"Supply of Test Room Console (customized integrated as single unit) as per clause 10 of RDSO/SPN/TC/99/2012 Ver.3.0 or latest. (Inspection agency:-RDSO)"

1

403983

403983

... More
"Gateway for Emergency communication at HQ/way stations as per clause 13 of RDSO/SPN/TC/99/2012 Rev.2 or latest. (Inspection agency:-RDSO) "

1

104119

104119

... More
Supply of DTMF Gateway 4 port as per Clause 12.2 of RDSO/SPN/TC/99/2012 Ver.3.0 or latest. (Inspection agency:-RDSO)

4

104119

416476

... More
"Mobile Application for event notification as per Clause no. 8.4.7 and 12.3.4 of RDSO/SPN/TC/99/2012 Rev.2 or latest. (Inspection agency:-RDSO)"

20

9996

199920

... More
Supply of managed router with ethernet 10/100/1000 Base-T LAN ports and WAN ports working on 48V DC. (Inspection agency:-Consignee)

2

137649

275298

... More
"Supply and installation of Layer 2 managed Gigabit switch for HQ LAN (servers), with minimum 24 ethernet 10/100/1000 Base-T ports having RSTP protocol ,POE+,IPV6 support. (Inspection agency:-Consignee)"

4

38824

155296

... More
Supply of remote fault diagonstic system . Configuration Intel Coe i 7 , operating system , window 8.1 or better or similar. (acer tmp 246 or better or similar). Inspection by Consignee

2

60290

120580

... More
"Supply of Cat-6 armoured cable of make D-Link, AMP., Finolex or similar. (Inspection agency:- Consignee)"

3050

25

76250

... More
"Supply and installation of 8 port Gigabit Managed PoE Layer 2 Switch supports 8 nos 10/100/1000BASE-T ports,along with 2 Gigabit SFP ports, having RSTP protocol+IPV6 support make DIGISOL / CISCO/JUNIPER or superior or similar. (Inspection agency:-RITES) "

6

13576

81456

... More
"Supply of D-Link Cat-6 Patch Cord Lan Cable having 5 metre length Or similar. (Inspection agency:-Consignee) "

160

314

50240

... More
"Supply and fixing of PVC casing caping of size 1"". (Inspection agency:-Consignee)"

3120

25

78000

... More
"Supply and installtion of DC to DC converter (48V DC to 12 V DC). Inspection agency:-Consignee)"

6

423

2538

... More
"Supply and installation of wall mountable 19''9 U rack with transparent door with all accessories like fans and tray with PDU etc. (Inspection agency:-RITES)"

6

3883

23298

... More
"Supply and installation of 19"" 42 U covered server Rack with front side transparent door with lock 21 arrangement, fitted with one no.FAN tray with 4 nos. 230 V operated fans,cable organizers 2 nos.,provision of two nos.of horizontal power supply (each consists of 8 Nos.x 15A/5A multi pin sockets with ON/OFF switch and fuse arrangement strip )Make HCL/Rittel/APW/President. (Inspection agency:-Consignee)"

1

20342

20342

... More
"Supply and fixing of PVC conduit pipe 25 mm dia along with all fixing accessories.like T, Bend pipe albow etc. (Inspection agency:-Consignee)"

500

34

17000

... More
"Supply of RJ-45 Connector D-Link make or better. (Inspection agency:-Consignee)"

500

5

2500

... More
"Installation , Testing and Commissioning of divisional HQ VOIP TCCS equipments at division and 24 at stations including all necessary fitting, joints, coupling etc. This includes proper wiring of data cables, power cables, Telecom cables, housing of equipments in the racks / cabinets etc. All installation materials like PVC pipes, Flexible pipes, Electrical MCB/ Switch / sockets/ boards etc. has been arranged by the bidder. (Inspection agency:-Consignee) "

1

2470625

2470625

... More
"Training of staff as per RDSO/SPN/TC/99/2012 Ver.3.0 or latest (Man hours) (Inspection agency:- Consignee) "

80

1694

135520

... More
Supply, installation, testing and commissioning of LED-Based 55-inch smart Android TV for Video Conferencing system. Make Samsung or Similar.

2

64989

129978

... More
Supply of Ahuja make.SSA -250 M P A AMPLIFIER or similar

1

20027

20027

... More
Supply of PA column Speakers Ahuja Make or similar ASC 20T

18

2510

45180

... More
Speaker cable 2 core PVC sheathed & screened of size 47/0.193 as per IS -694 or latest RDSO specification Running

5000

71

355000

... More
Supply Installation and commissioning of maintenance free earthing system which consists of supply of earthing kit-1 set consisting of (1) Earth Electrodes of copper clad steel alloy of 10 feet (3mts) long, 6 17mm dia and copper thickness of 250 microns- 1Nos. (II) RDSO approved Earth enhancing compound in 30 kg. Pack - 01 Nos. (III) Copper tape of 25mm x 6mm x 300mm with 99% purity - 02 Nos. and another of 25 mm x 6mm x 150mm to terminate on earth electrode. The earthing material shall be supplied as per RDSO specification RDSO/SPN/197/2008 or latest.

1

61612

61612

... More
"Counter communication system mode no. CCS-2300 make :Ahuja Shureoutput:- 2w (max) in each 7 amplifier, microphone electret condenser in both the units, auto mute % F3n -enables after 30 seconds (approx),power required :-AC :220240V,50/60 Hz, protection- AC fuse 1X0.5A it consists of an attendant unit, customer unit and a power supply. firm should be ISO 9001 certifield."

2

6780

13560

... More
"Supply, installation, testing and commissioning of Surveillance Hard Disk with a capacity to record upto 4 TB data Make Toshiba, Seagate, Western Digital Inspection : Consignee"

1

12218

12218

... More
"Supply and testing of Crimping tool for RJ-45 and RJ-11. Make: AMP, D-Link or similar of reputed make.[Inspection by Consignee]"

2

1264

2528

... More
Supply of remote fault diagonstic system . Configuration Intel Core i 7 , operating system , window 8.1 or better or similar. (acer tmp 246 or better or similar) with SSD Inspection by Consignee

3

89986

269958

... More
HP multifuntion machine, on site OEM warrenty 01 Year Brand HP OR CANON Multi funtion Laser Printer or better or similar. Inspection by Consignee

3

18442

55326

... More
"Supply of 6 Fiber Core armored single mode optic Fiber cable 17.2.2 of RDSO/SPN/ TC/65/2021 Rev.6.0 or latest Schneider, Systemax, Panduit, D-Link, Finolex Inspection by Consignee"

1000

67

67000

... More
Supply of power cable 3 core, 2.5 sq mm, multi strand (36/0.3 mm dia) cable as per IS 694:1990 reaffi rmed 1995 or latest suitable for Railway electrifi cation area, shall be of reputed make like Havells, Delton, LAPP, Finolex, or superior

1000

82

82000



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.