Purvanchal Vidyut Vitaran Nigam Limited Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Purvanchal Vidyut Vitaran Nigam Limited - PUVVNL Tender
Energy, Oil and Gas
Eprocure
Opening Date18 Nov 2024
Closing Date3 Dec 2024
Tender Amount₹ 3,16,50,810
Costs
EMD
₹ 3,16,508Document Cost
₹ 5,900Tender Fee
Refer Documents
Summary
Supply And Erection 1000 Kva Compact Type Transformer And Construction Of Line For Issuing 1500 Kva/1667 Kva New Connection For Regional Manager Prayag. Depot, Rajapur Prayagraj On Semi-turn Key Basis Under Eudd-mayohall In The Head Of Deposit Scheme
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_PVVNV_974759_1Tender No
20/EUDC-II/PYG/SE/2024-25Tender Authority
Purvanchal Vidyut Vitaran Nigam Limited ViewPurchaser Address
-Website
http://http://puvvnl.up.nic.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
11 KV Cable jointing kit O/D 3*120 SQMM
34
-
-
11 KV Cable jointing kit I/D 3*120 SQMM
12
-
-
11 KV Cable jointing kit S/T 3*120 SQMM
10
-
-
11 KV Cable jointing kit O/D 3*185 SQMM
4
-
-
Pipe electrode Earthing Complete
24
-
-
Fire fighting equipment
10
-
-
control cable 2*2.5 sq mm
300
-
-
control cable 4*2.5 sq mm
200
-
-
24V battery & charger with cabinet
1
-
-
Structure for 33 KV VCB
1
-
-
Red oxide paint
10
-
-
GI Pipe 6'' dia
96
-
-
Clamp for foxing pipe
32
-
-
MS Nut bolt with washer
100
-
-
MS Angle iron cross bracing with 4 no clamp 65*65*6*2700 mm
3
-
-
Barbed wire
74
-
-
Aluminium paint
31
-
-
Service clamp
31
-
-
Danger board with clamp
11
-
-
Top channel 100*50*2240 mm
1
-
-
Number plate
1
-
-
Droper channel
1
-
-
MS Rod Earthing complete
16
-
-
11 KV LINE & METERING WORK
-
-
-
Construction of cast concrete foundation plinth for 11/0.4 KV CSS 1000 KVA Plinth size length and width as per requirement. 0.5 mtr. plinth Height from surface, and 0.6 mtr. below from surface. ratio 1:3:6 cement, sand and concret. concreting upto 15 cm. thickness after ramming should be done. The two channels (rail pole) should be grouted as per direction of site in charge. (All material related this work like cement ,bricks, sand etc will be arranged by the contractor at his own cost)
3
-
-
Cartage ,Erection & commissioning of Compact sub station 1000 KVA,11/0.4 KV on plinth along with HT/LT connections Complete in all respect, as per Resspo and Electrical Safety rule (All material related this work like compact sub ststion & its all accessories will be arranged by the contractor at his own cost)
3
-
-
Providing fixing of welded wire mesh fencing, around transformer plinth having one locking arrangements, Fencing should be provided by grouting MS angle 40x40x5 mm & wire mesh size 8 SWG(wire mesh bitween the MS nagle will be as per standard practice and design..) Fencing length & width is require as per site. The painting of fencing should be done by good quality green paint with two coats after rubbing and cleaning and providing one coat red oxide primer. The fencing should be 2 M. above ground level. The rates should be inclusive of all materials required for completion of above work. (All material related this work will be arranged by the contractor at his own cost)
1
-
-
Cartage, Erection, grouting, plinthing, earthing & painting of 11 mtr long sub station type D/P for mounting of CVT outdoor metering with all accessories like MS cross bracing,channel etc. grouting in ratio 1:4:8, cement, stone grit & coarse sand, plinthing of support of size 0.4x0.45x0.3 Mtr. with cement sand& bricks blast in ratio 1:4:8 and 12 mm thick plastring around the plinth in ration 1:2:4 with 12 mm thickness curing of plingth should be done properly as per Resspo and Electrical Safety rule (All decentralized material like Holding clamp, service clamp,MS cross bracing angle,GI pipe, nut bolt ,number plate,danger board,barbed wire,paint,and material related civil work will be arranged by the contractor at his own cost)
1
-
-
Cartage, Erection, grouting, plinthing, earthing & painting of 11 mtr long double pole structure D/P for 11KV XLPE cable out door hosting with all accessories like MS cross bracing,channel etc. grouting in ratio 1:4:8, cement, stone grit & coarse sand, plinthing of support of size 0.4x0.45x0.3 Mtr. with cement sand& bricks blast in ratio 1:4:8 and 12 mm thick plastring around the plinth in ration 1:2:4 with 12 mm thickness curing of plingth should be done properly as per Resspo and Electrical Safety rule (All decentralized material like Holding clamp, service clamp, nut bolt,channel,MS cross bracing ang,GI pipe ,number plate,danger board,barbed wire,paintand material related civil work will be arranged by the contractor at his own cost)
6
-
-
Fixing & grouting of stay rod with cement, sand and bricks ballast in ratio 1:4:8 and fastening the stay wire with pole and stay rod nozzling. (All decentralized material Holding clamp, nut & bolt and material related civil work, will be arranged by the contractor at his own cost)
4
-
-
Cartage & Laying of single 11 KV 3x120 sq mm XLPE cable by machine HDD (Horizontal Directional Drilling) method/ manual drilling method. The cable shall be laid at the depth of 1050 mm from the surface of road. The cable shall be laid strictly in compliance to RESSPO Norms (All material realated this work will be arranged by the contractor at his own cost except 11 KV 3x120 Sqmm XLPE Cable)
3550
-
-
Fixing of Heat Shrink cable type end Terminations suitable for 11 KV, 3x120 sq mm XLPE cable as per Resspo and Electrical safety rules. (All material related this work will be arranged by the contractor at his own cost)
-
-
-
Straight through jointing kit
10
-
-
Outdoor/indoor jointing kit
42
-
-
Hoisting of 11 KV 3x120/3X185 sq mm XLPE cable providing GI pipe of size 6” dia 3 M long on double pole including its jumpering complete (All material related this work like Holding clamp, nut bolt, GI pipe etc will be arranged by the contractor at his own cost)
30
-
-
Earthing of support/Pannel complete with the help of M.S. rod 16 mm dia and 2.5 mtr long using charcoal & salt layer properly. fastening of G.I. wire with clamps/X-arm/support to M.S. earth rod.Testing of earthing as pe rule ofter complete this work result will be satishfactory then connect all connection properly (All decentralized material G.I. strip ,nut bolt and clamp ,charcoal, salt etc will be arranged by the contractor at his own cost)
16
-
-
Earthing of transformer body, neutral & metering cubical by lowering of pipe earthing connecting with GI Strip of size 25x6 mm with clamps, Testing of earthing as pr rule ofter complete this work result will be satishfactory then connect all connection properly (All material related this work will be arranged by the contractor at his own cost)
6
-
-
Caetage ,Errection, Commissioning and grouting of 11 KV HT Metering cubical and 11 KV CVT complete with making foundation for cubical, earthing & its proper connection. (All material except 11 KV CVT UNIT & 11 KV HT Metering cubical will be arranged by the contractor at his own cost)
1
-
-
33/11 SUB STATION WORK
-
-
-
Cartage of 11 KV 3x 300 and 3*120 /185 sq mm XPLE cable from Store to dump store/work Site Including loading and unloading
380
-
-
Cartage of 33 KV VCB,control pannel, and 11 KV Pannel with VCB,I/C & O/G, and 11 KV Bus Coupler from Store to dump store/work Site Including loading and unloading
1
-
-
Cartage of 33 KV PT and 33 KV CT from Store to dump store/work Site Including loading and unloading
1
-
-
Cartage of 5 MVA Power Transformer from Store to dump store/work Site Including loading and unloading
1
-
-
Erection of complete bus bar gantry in switch yard as per RESPO . Work also includes construction of gantry plinth of size 1.0x0.45x0.45 cum with Cement,coarse sand and ballast in ratio 1:3:6 and plastaring of plinth with cement & sand in ratio 1:4 including digging of pits& backfilling. All concreting material like Channel, Clamp, cement, ballast, sand labour & T&P etc. will be provided by the contractor at his own cost). (Including Carrige of Related Centerliazed Materials)
1
-
-
Erection,making foundation, Grouting, earthing and painting of complete structure for Line and Bus Isolator and Instalation of 33 KV Line/Bus Isolator with all fitting in switch yard as per RESPO . Work also includes construction of plinth of size 1.0x0.45x0.45 cum with cement, coarse sand and ballast in ratio 1:3:6 and plastaring of plinth with cement & sand in ratio 1:4 including digging of pits & backfilling. (All Require material as like clamps nut and bolts etc and concreting material like cement, ballast, sand labour Line/Bus Structure with fitting will be provided by the contractor.) (Including Carrige of Related Centerliazed Materials)
2
-
-
Erection of complete structure and instalation of 33 KV lightening arresstor with earth couter meter, in switch yard as per RESPO . Work includes erection of 3 Nos.33 KV lightening arrestor, its fitting and mounting with care. Grouting of structure with cement, coarse sand and ballast in ratio 1:3:6, construction of plinth size 0.90x0.45x 0.45 cum. Plastering the plinth with cement mortar with cement and sand in ratio 1:4.(All Require material as like clamps nut and bolts etc and concreting material like cement, ballast, sand labour LA Arresster Structure with fitting will be provided by the contractor.) (Including Carrige of Related Centerliazed Materials)
2
-
-
Construction of complete T/F plinth size 3mx3m x 0.3 Mtr. above the ground level and 0.75 Mtr. deep foundation . Top of plinth is to be C.C. work in the ratio of 1:3:4 fitted with 3 Mtr. long, 90 lbs, 2Nos. rail pieces. Cement mortar is to be used in 1:3 ratio. Cement, concrete material, bricks used in plinth shall be supplied by the contractor. 6” stone grit is to be laid before foundation start for whole plinth. All material shall be provided by the contractor. (Including Carrige of Related Centerliazed Materials)
1
-
-
Instalation of complete 33 KV VCB 800A ,750MVA with structure in switchyard and making foundation of VCB structure by cement, sand, brick ballast mortar in ratio 1:3:4. Work includes complete fitting of VCB on structure carefully with making all connections of control cable for operating the VCB . All Require item like cement, concrete material, T&P and all require clamp nut bolts and clamps will be provided by the contractor exept 33 KV VCB 800A ,750MVA. (Including Carrige of Related Centerliazed Materials)
1
-
-
Mounting of complete 33 KV C.T 200/100/1-1-1A (02 NO) with structure in switchyard and making foundation of C.T. structure by cement, sand, brick ballast mortar in ratio 1:3:4. Work includes complete fitting of C.T. on structure carefully with making all connections of control cable . All Require item like, CT Clamps, cement, concrete material, T&P will be provided by the contractor except 33 KV C.T (Including Carrige of Related Centerliazed Materials)
1
-
-
Instalation of complete 33 KV P.T (03 NO) with structure in switchyard and making foundation of P.T. structure by cement, sand, brick ballast mortar in ratio 1:3:4. Work includes complete fitting of P.T. on structure carefully with making all connections of control cable . All Require item like Pt Clamps, cement, concrete material, T&P shall be provided by the contractor except 33 KV P.T (Including Carrige of Related Centerliazed Materials)
1
-
-
Installation of 33 KV single transformer control pannel & 33 KV line control pannel in the switchgear room and grouting the pannel by rag bolt using cement, sand mortar in ratio 1:3. Work includs fitting of all accessories in all respect with complete connection of control cable with pannel. Grouting material and all require materia as control cable 2x2 sq mm and 2x4 sq mm will be provided by the Contractor.except 33 KV single transformer control pannel
1
-
-
Erection of 33 KV post Insulators with complete structure in Switch yard as per RESPO . Work includes Installation of 2X3 Nos. 33 KV Post Insulator on each structure complete as per schedule, grouting of Structure with Ist class brick ballast in the ratio of 1:3:6, plastering in the ratio of 1:3 on plinth size 0.90x0.45x0.45 Cum. The work is to be done strictly as per RESPO . All the material like clap, Cement, concrete material used for above work will be provided by the Contractor. (Including Carrige of Related Centerliazed Materials)
1
-
-
Installation of 33/11 KV 5 MVA T/F on the transformer plinth. This work includes dragging loading, shifting, lifting and complete assembling after placing on the plinth.All special and ordinary T&P is to be arranged by the contractor. Special care is to be taken to avoid tilting of T/F and loss of transformer oil. Any damage in T/F will be chargeable to contractor.
1
-
-
Earthing of 33 and 11 KV indoor equipments, switchgears by 40 mm dia 2.5 Mtr. Long G.I. pipe electrodes/rod by digging 3 Mtr. deep pits and connecting with GI Strip of size 25x6 mm with clamps, Testing of earthing as pr rule ofter complete this work result will be satishfactory then connect all connection properly (All material related this work will be arranged by the contractor at his own cost)
1
-
-
Earthing of 33 KV C.T. Structure complete by 40 mm dia 2.5 Mtr. Long G.I. pipe electrodes/rod by digging 3 Mtr. deep pits and connecting with GI Strip of size 25x6 mm with clamps, Testing of earthing as pr rule ofter complete this work result will be satishfactory then connect all connection properly (All material related this work will be arranged by the contractor at his own cost)
1
-
-
Earthing of lightening arrestor structure with 8 Nos. additional 40 mm dia 2.5 Mtr. Long G.I. pipe electrodes/rod by digging 3 Mtr. deep pits and connecting it with L.A. through G.I. Strip 35x6 mm welded at both ends, Testing of earthing as pr rule ofter complete this work result will be satishfactory then connect all connection properly (All material related this work will be arranged by the contractor at his own cost)
3
-
-
Special earthing of T/F neutral by boring 2" dia 60 feet long G.I. pipe in the wet earth and connecting it with 35x6 mm. G.I. strip to T/F neutral giving half round turn at the T/F(Delta). Two separate earthing to be provided to T/F body by connecting it with earth mat by special earthing arrangement for earthing work. Material like strip of size 50x6/35x6 mm and G.I. pipe 2” dia 2.9 mm thick. All the material will be provided by the contractor.(As per RESSPO)
2
-
-
Laying and stringing of ACSR DOG conductor for busbar between busbar gantry as well as terminal gantry. Three phase jumpering from bus to bar L.A, VCB, C.T., P.T., Post insulator, and 33/11 KV T/F, Terminal Gantry, Isolator etc. properly with jumpering with P.G. Clamp, T. Clamp and Post Insulator clamp, All decentraliselike clamp,nut bolt,pg clampetc. material will be provided by the contractor .
1
-
-
Erection Cable Stand in Switch yard for 1 No 33 KV Incoming Source and 2 No for 11 KV Power Transformer secondary side outgoing side. Including grouting and Calmping of cable (Cable stand as per sample, Grouting Material and clamp and nut bolts provided by contractor)
1
-
-
Painting of all structure and equipment inside the switch yard with two coats of red oxide primer and thereafter two coats of aluminium paint, giving silver white finish, painting is to be done after proper cleaning of the structures. paint, primer, thinner etc. required will be provided by the contractor himself.
1
-
-
Instalation of fire stand & fire bucket with M.S. Angle Iron 50x50x6 mm with shed of M.S. sheet to cover the bucket and stand properly. All matrial required for this work like except M.S. Angle. 5 Nos fire bucket with sand will be provided by contracto
1
-
-
Installation of 24 VOLT BATTERY AND BATTERY CHARGER WITH CABNET in the switch gear room, by grouing base channel 100 x 50 x 6 x 1000mm. Fixing of rag bolt. (battery & Charger provided by contrctor)
1
-
-
Laying of 11 KV 3 x 300 Sqmm. XLPE power cable by digging 0.75 Mtr. deep trench, putting layer of sand in the bottom, ramming it, laying of cable over it RMT and covering the cable from sides and top by laying bricks, finally covering the same by earth and levelling of the same, all the materials, except cable, will be pvovided by the contractor.
60
-
-
Laying of 11 KV 3 x 120/185 Sqmm. XLPE cable from O/g VCB to DP by digging 0.75 Mtr. deep trench, putting layer of sand in the bottom, ramming it, laying of cable over it RMT and covering the cable from sides and top by laying bricks, finally covering the same by earth and levelling of the same, all the materials, except 3x185/3x120 Sqmm XLPE 11 KV cable, will be pvovided by the contractor.
320
-
-
Fixing of termination of 11 KV cable boxes Boxes will be of Heat Shrink indoor type and outdoor type .All material will be arranged by the contractor
-
-
-
Outdoor jointing kit 3x 300/185/120 sq mm
8
-
-
Indoor jointing kit 3x 300 /185/120 sq mm
2
-
-
Installation of 11 KV VCB in the switch gear room, by grouting base channel 100 x 50 x 6 x 1000mm. Fixing of 11 KV switchgears rag bolt, mounting of P.T. on incoming.
-
-
-
11 KV incoming
1
-
-
11 KV O/G VCB
1
-
-
11 KV BUS-CUPLER
1
-
-
Laying of 0.4 KV Alm. PVC 4x25s q mm. power cable from sub station T/F to L.T. Distribution Board. Approx Length of cable 100 Mtr. All materials like LT Cable, DB, LT Power Board etc will be arranged by the conctractor
50
-
-
Laying of following copper control cable form C.T. T/F to transformer control panel /protection Board. All control cable will be provided by the contractor.
-
-
-
2*2.5 sqmm
200
-
-
4*2.5 sqmm
300
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%