Public Works Department Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Public Works Department - PWD Tender
Civil And Construction
Road Construction
Eprocure
Opening Date22 Jan 2025
Closing Date27 Jan 2025
Tender Amount₹ 13,08,000
Costs
EMD
₹ 1,30,800Document Cost
₹ 860Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_PWDBL_994627_1Bid Award Id
ViewTender No
136/E-Tender/2024-25 dt. 13.01.2025Tender Authority
Public Works Department ViewPurchaser Address
-Website
http://http://uppwd.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
Providing and laying damp-proof course 40 mm thick with cement concrete 1:2:4 (1 Cement: 2 coarse sand zone-III) derived from natural sources: 4 graded stonr aggregate 12.5 mm nominal size derived from natural sources) DSR No. 4.10,
3.24
324
1049.76
... More
Brick work with Common burnt clay (Non Modular ) bricks of Class-150 in Superstructure above plinth level up to floor V level in all shapes and size in Cement Mortar 1:4 Cement and Coarse sand in including Supply of all materials labour T& etc required for proper completion of work as per DSR.No-6.4.1,
6.68
7381
49305.08
... More
Centering and shuttring including strutting, Propping etc. and removal of from for suspended floors, roofs, landings , balconies and access platform. DSR-5.9.3,
12.43
732
9098.76
... More
Reinforced cement concrete work in beams, suspended floors, roofs having slop up to 15 landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III): 3 graded stone aggregate 20 mm nominal size derived from natural sources. DSR N0-5.3,
2.53
9088
22992.64
... More
Steel reinforcement for R.C.C. work including Straightening, Cutting, Bending, Placing in position and binding all Complete upto Plinth Level. Themo-Mechanicaily Trated Bars of grade Fe-500D or more. DSR-5.22C.1,
248.44
78
19502.56
... More
Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat 20 mm cement plaster. DSR No 13.9.2,
35.35
463
16367.05
... More
Three Tack Three Panels Sliding window with two glazed & One wire mesh panels with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body. Using R23 series with frame (98mm & above) x(40mm & above)& both glazed and fly screen sadh (30mm & above) X (55mm & above) with zinc aloy (zamak) powder coated handle on every glazed panel along with multi-point locking system. (Height upto 1.8m) DSR No. 9.147.A4.2,
45.04
8590
386893.6
... More
Fixed window / ventilator without mullion / Transom_ Using R3 series with frame (55 mm & above) x (45 mm & above). (Height upto 2.5 metre) DSR No 9.147.C1.3,
13.97
5592
78120.24
... More
Providing and laying Vitrified floor tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved Make, in all colours & shades, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Jointing with grey Cement Slurry @ 3.3 kg/Sqm including grouting the joint with white cement and matching Pigments etc. Complete. Size of Tile 600x600 mm. (DSR-11.41.2)
13.84
1227
16981.68
... More
Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. For thickness of tiles 10 mm to 25 mm DSR. 15.23.1 ,
22.08
57
1269.6
... More
Providing and laying Rectifited Glazed Ceramic floor tiles of Size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with Grey cement Slurry @3.3kg/Sqm including Grouting the Joints with and matching pigment etc., complete. (DSR-11.40)
22.08
1137
25104.96
... More
Providing and laying 60 mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. DSR No. 16.68,
94.92
767
72803.64
... More
Providing and applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top of concrete roof in three coats @10.76 litre/ 10 sqm. One coat of self-priming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric waterproofing liquid (dry film thickness of complete application/system not less than 500 microns). The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as per the direction of Engineer- in-Charge. DSR No. 22.22A,
559.55
444
248440.2
... More
Dismantling old Plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dummping ground within 50 metres lead. DSR No.-15.56,
208.18
43
8951.74
... More
12mm. Thick plaster with cement mortar in proportion of 1:4 cement & coarse sand DSR No. 13.4.1,
208.18
282
58706.76
... More
Removing white or colour wash by scrapping andsand papering and preparing the surface smooth including necessary repairs to scratches etc. complete DSR N0 13.88,
361.24
15
5599.22
... More
Providing and Applying white Cement based Putty of average thickness 1 mm. of approved brand and manufacture. Over the Plastered wall Surface to Prepare the Surface even and Smooth Complete. DSR N0-13.80)
569.42
123
70038.66
... More
Wall Painting with acrylic emulsion paint, having VOC (Voiating Organic Compound) Content less than 50 grams/litre of approved brand and manufacture, lncluding applying additional coats wherever required, to achive even shad and colour. Two Coat, DSR.N0-13.83.2),
632.67
112
70859.04
... More
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade Old work (Two or more coats applied @1.43 ltr/10sqm) over existing cement paint surface (apex Ultima, weather coat All guard). (DSR N0. 13.112.1),
860.18
103
88598.54
... More
Painting with synthetic enamal paint of approved brand and manufacture of required colour to given an even shade,Two or more Coats on New work over an under coat of suitable shade with ordinary paint of approved brand and manufacture. DSR.N0-13.62.1),
73
178
12994
... More
Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. DSR No-15.60
8
208
1668
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements