Public Works Department Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Public Works Department - PWD Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date13 Dec 2024
Closing Date23 Dec 2024
Tender Amount₹ 8,76,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Providing and laying in position ready mixed or site batched design mix cementconcrete for plain cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana/ Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering and finishing as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the minimum specified cementcontent, the contractor shall have discretion to either re-design the All works upto plinth level :mix or bear the cost of extra cement. Concrete of M10 grade with minimum cement content of 220 kg /cum As per DSR 4.20.1.1

497.31

6493

3229033.83

... More
Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and around the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete (plinth area of the building at ground floor only shall be measured as per I.S.6313(PartII 1981)Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows : (1)Treatment for masonary & foundation 5 liters per sqm. (2) Back fill in immediate contact with foundation 7.5 liters/sqm (3) Treatment of top surface of plinth filling 5 liters/sqm (4) Treatment of soil along external perimeter of building 7.5 liters/sqm. (5) Treatment of soil under apron along external perimter 5 liters/sqm. 2.35.3

1091.4

227

247747.8

... More
Reinforced cement concrete work in beams suspended floors, roofs having slope up to 15° landings, balconies, shelves, chaijjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). R.C.C. work in Lintel. as per DSR 5.3

707.14

8456

5979575.84

... More
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :. 1:1.5:3 (1 cement : 1.5 coarse sand (zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) R.C.C.work in footing DSR 5.1.2

396.87

6648

2638391.76

... More
Reinforced cement concrete work in wall (any thickness ) including attached plaster, butteresses plinth and string cources fillets, column, pillers, piers, abutment, post and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering finishing and reinforcement 1:1.5:3 (1 cement:1.5 coarse sand:3 graded stone aggregiate 20 mm nominal size derived from natural sources. as per DSR 5.2.2

247.83

7976

1976692.08

... More
Class 150 brick work in 1:6 (one cement and six coarse sand sand of 2.25 fineness modulus) mortar in foundation & plinth including supply of all materials, labour and T & P etc required for proper completion of the work.DSR 6.1.2

152.45

5242

799142.9

... More
Brick work in super-structure in 1:6 (1:6 cement & coarse sand) above plinth level up to floor two level (up to two storeys) including necessary cutting and moulding of bricks as required ..DSR 6.4.2

798.85

6692

5345904.2

... More
Half brick masonry with (Class M-150 First Class Brick) in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand) DSR 6.13.2

1353.82

825

1116901.5

... More
Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size). 4.1

144.65

301

43539.65

... More
Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil. 4.13

144.65

107

15477.55

... More
Providing and Laying integral cement based water proofing treatment including prepartaion of surface as required for treatment of roofs, balconies, terraces etc consisting of following oprations. (a)Applying slurry coat of neat cement using 2.75 kg / sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer in charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment (b) laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1cement:5coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by Engineer in charge over 20 mm thick layer of cement mortoar of mix 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by engineer in charge to required slope and treating similerly the adjoining walls upto 300 mm hight including rounding of junctions of walls and slabs.( c ) after two days of proper curing applying a second coat of cement slurry using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS 2645 and approved by engineer in charge. (d) finishing the surface with 20 mm thick jointless cement mortor of mix 1:4 (1cement :4coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by engineer in charge including laying glass fiber cloth of approved quality in top layer of plaster and finaly finishing the surface with trowel with net cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) the hole tarrace so finished shall be floaded with water for a minimum period of two week for curing and for final test all above operation to be done in order and as directed and specified by the engineer in charge. with average thickness of 120 mm minumum thickness at khurra as 65 mm.

1035.17

1238

1281540.46

... More
Supply & fixing of flush door commercial quality conforming to I.S. : 2202 Part I (1983) including fixing of wooden cleats & stopper and including fixing and adjustment of hinges , Bolts locks , handles , springs , fitting with necessary screws to be supplied departmentally.Extra for Providing and fixing flush doors with decorative veneering instead of non decorative ISI marked flush door shutters conforming to IS: 2202 (Part I)Both SIde Laminated (35mm thick). DSR-9.21.1

510.94

2461

1257423.34

... More
Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) DSR 10.15.1

28167.6

143

4027966.8

... More
Providing and fixing wire gauge shutters using stainless steel grade 304 wire gauge with wire of dia 0.5 mm and average width of aperture 1.4 mm in both directions for doors, windows and clerestory windows with necessary screws 35 mm thick shutters Second class teak wood. DSR-9.134.1.2.1

260.2

3834

997606.8

... More
Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete. With 2nd class teak wood beading 62X19 mm. DSR-9.51.1

371.5

961

357011.5

... More
TMT Fe-500 steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of all steel and and over lapping & hooks. DSR 5.22.6

1861.46

7926

14753931.96

... More
Fixing of Door, windows/ventilators chaukhats in position. PWD-NS-3 (a) Door/Window chaukhats above 1.5 sqm

281

1310

368110

... More
Fixing of Door, windows/ventilators chaukhats in position. PWD-NS-3 (b) Window chaukhats up to 1.5 sqm

151

826

124726

... More
Fixing of Door, windows/ventilators chaukhats in position. PWD-NS-3 (c) Ventilator chaukhats (1/2) of door

78

625

48750

... More
15mm thick plaster with cement mortar in proportion of 1:4 cement & coarse sand of 2.25 F.M. DSR-13.5.1-14.05%

191.81

302

57926.62

... More
12mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or rounded angles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. (1)1 cement : 6 coarse sand. F.M.-2.25. DSR 13.4.2

5784.01

252

1457570.52

... More
15Mm cement plaster in single coat on rough side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or rounded angles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. (1)1 cement : 6 coarse sand. F.M.-2.25. DSR 13.5.2

7801.3

290

2262377

... More
12mm thick plaster in 1:3 cement & coarse sand on ceiling and soffits of stairs upto floor two level. DSR 13.9.1

2608.51

330

860808.3

... More
Making grooves 10 to 12 mm wide 8mm deep in plaster of the wallor in ceiling vertically or horizontally as required. DSR 13.76

2989.88

73

218261.24

... More
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm. DSR 11.46.2

1394.93

1192

1662756.56

... More
Supply and fixing 6 mm (1/4") thick China glazed tiles in flooring or in skirting or dado laid with 1:3 cement and approved coarse sand mortar finished with white cement slurry jointing and polishing complete including supply of all materials, labour and tool sand plants etc. required for proper completion of the work. Anti Skid Tiles. DSR 11.37A

804.76

817

657488.92

... More
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :25 mm thick. DSR -11.26.1

914.92

1431

1309250.52

... More
Kota stone slabs 25 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. DSR -11.27

234.66

1730

405961.8

... More
Cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement without base concrete (25 mm thick floor). DSR 11.3.1

628.91

451

283638.41

... More
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture. and also for wooden painting DSR 13.62.1

1665.39

166

276454.74

... More
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) with base of wall putty . DSR 13.47.1

6574.05

125

821756.25

... More
Distempering (Two coat) with oil bound distemper of approved brand and manufacture & of required shade on undecorated wall surface to give an even shade over & including a priming coat with cement primer of approved brand & manufacture such as Berger,J&N, Shalimar, Asian paints after thoroughly brushing the surface free from mortar droppings & other foreign matters & also including preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth including cost ofall materials. DSR 13.41.1

9347.81

136

1271302.16

... More
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. DSR-13.80

16213.82

114

1848375.48

... More
Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes. DSR-10.30.1

371.5

782

290513

... More
Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete : 250x16 mm. DSR-9.62.2

249

142

35358

... More
Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete : (a) 250 mm x 10mm DSR-9.63.1

249

61

15189

... More
Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete : (a) 200 mm x 10mm DSR-9.63.2

249

51

12699

... More
Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete : 125 mm. DSR-9.66.1

498

61

30378

... More
Providing & laying of light cinder filling under floor of toilets & other sunken roofs. MR

60.7

1695

102886.5

... More
Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.DSR 22.5

319.39

453

144683.67

... More
P/F curtain rods of 1.25mm thick chromium plated brass plate, with two chromium plated brass brackets fixed with C.P. brass screws and wooden plugs etc. wherever necessary complete (a) 25 mm dia. DSR-9.46.3

471.83

386

182126.38

... More
Providing and fixing cup board shutters with 25mm thick veneered particle board IS: 3097 marked exterior grade (Grade 1) of approved make including lind class teak wood lipping of 25mm wide x 12 mm thick with necessary screws and bright finished stainless steel plano hinges complete as per direction of Engineer-in Charge. With decorative veneering on one side and commercial veneering on other side. DSR-9.130.1

219.03

1416

310146.48

... More
Providing precast cement concrete Jali 1:2:4 (1 cement : 2 coarse sand(zone-III) : 4 graded stone aggregate 6mm nominal size ) , reinforced with 1.6 mm dia mild steel wire, including centering and shuttering, roughening cleaning, fixing and finishing in cement mortar 1:3 (1 cement: 3 fine sand) etc. complete, excluding plastering of the jambs, sills and soffits. DSR-5.18.2

25.95

5790

150250.5

... More
Centering and shuttering including strutting, propping etc. and removal of form for all heights : a)Foundations, footings, bases of columns, etc. for mass concrete.

848.13

288

244261.44

... More
Centering and shuttering including strutting, propping etc. and removal of form for all heights : b)Columns,Pillars, Piers, Abutments, Posts and Struts.

2960.56

706

2090155.36

... More
Centering and shuttering including strutting, propping etc. and removal of form for all heights : c) Lintel beam, Plinth beam, graders brasmer and cantilever

3889.56

541

2104251.96

... More
Centering and shuttering including strutting, propping etc. and removal of form for all heights : d)Suspended floors, roofs, landings, balconies and access platform.

3294.48

681

2243540.88

... More
52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer's specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.

15.24

719

10957.56

... More
Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement. 18 mm thick

2.48

486

1205.28

... More
Supply & fixing of glass strips of 4.0mm thickness in joint of floor and skriting at the time of laying labour, tool mand plants etc. complete (3.5cm depth & 5 mm thickness)

22.86

67

1531.62

... More
Supply and fixing rolling shutters of approved make made of 8.25mm (3"x18 gauge) cold rolled M.S. path interlocked through out their entire length and joined togather at the end by end locks and mouted on specially designed pipe shaft with brick etc. side guides and arragement for inside and outside locking with push and pull operation complete with excluding the cost top cover and spring.

7.06

2685

18956.1

... More
Providing and fixing ball bearing for rolling shutters.

2

361

722

... More
Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying: (a) after surface preparation, first layer of slurry of cement @ 0.488 kg/ sqm mixed with water proofing cement compound @ 0.253 kg/sqm. (b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. (c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. (d) fourth and final layer of brick tiling with cement mortar (which will be\ paid for separately. For the purpose of measurement the entire treated surface will be measured.

31.72

506

16050.32

... More
Internal Plumbing Providing and fixing water closet squatting pan ( Indian type W.C. pan ) with 100mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever) conforming to IS:7231, Parryware/ Hindware / Seabird / Orient (Coral) with all fittings and fixtures complete including cutting and making good the walls and floors wherever required. White Vitreous china Orissa pattern W.C. pan of size 580x440mm with integral type foot rests. DSR 17.1.1

46

4974

228804

... More
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever), conforming to IS : 7231, Parryware/Hindware/Seabrid /Orient (Coral) with all fittings and fixtures complete including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked black solid plastic seat and lid DSR

4

4691

18764

... More
Providing & fixing white vitreous china wash basin with C.I. brackets painted white, 15mm C.P. brass cutting & making good the walls wherever required.a) Flat back wash Basin size 550x400 mm with single 15mm C.P. brass pillar tap. pillar taps, C.P. brass chain with rubber plug, 32mm C.P. brass waste of standard pattern including.DSR 17.7.4

27

1381

37287

... More
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. semi rigid pipe. 32 mm dia DSR 17.81.1.1

13

76

988

... More
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. semi rigid pipe. 40 mm dia DSR 17.81.1.2

42

85

3570

... More
Providing & fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick asbestos cement sheet ground fixed to wooden cleats with C.P. brass screws and washers. DSR 17.31

31

1181

36611

... More
Providing and fixing Stainless Steel AISI 304 (18/8) kitchen sink as per I.S. 13983 with C.I. brackets and stainless steel plug 40 mm including painting of fittings and brackets, cutting and making good the walls wherever required :Kitchen sink with drain board. 510x1040mm bowl depth 250mm DSR 17.10.1.1

5

5105

25525

... More
Providing and fixing Stainless Steel AISI 304 (18/8) kitchen sink as per I.S. 13983 with C.I. brackets and stainless steel plug 40 mm including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink without drain board. 610x510 mm bowl depth 200 mm DSR 17.10.2.1

38

3631

137978

... More
Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350mm and 340x410x265mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I. clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required: DSR 17.4.1

19

4600

87400

... More
Providing and fixing unplasticised PVC connection pipe with brass unions 45 cm length. 15 mm nominal bore. DSR 18.21.2.1

103

71

7313

... More
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 a) 15 mm nominal bore. DSR 18.49.1

64

372

23808

... More
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.a) 15 mm nominal bore. DSR 18.51.1

63

587

36981

... More
Providing and fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS:8931 a) 15 mm nominal bore. DSR 18.53.1

66

422

27852

... More
Providing and fixing ball valve (brass) of approved quality complete. (High or low pressure with plastic floats). 25 mm nominal bore

28

341

9548

... More
Providing and fixing C.P. brass shower rose with 15or 20mm inlet, 150 mm diameter

24

163

3912

... More
Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931: 18.52.1 15mm nominal bore

26

492

12792

... More
Providing & fixing soil, waste and vent pipes. 17.35.1.2 a) 100mm dia centrifugally cast iron S & S pipe.

380

867

329460

... More
b) 75mm dia centrifugally cast iron S & S pipe.

445

871

387595

... More
Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes & fitting of diameters. 17.58.1 a) 100mm

195

457

89115

... More
Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes & fitting of diameters. 17.58.2 b) 75mm

269

386

103834

... More
Providing & fixing M.S. holder bat clamps of approved design to sand cast iron/centrifugally cast (Spun) iron S & S pipe embeded in & including cement concrete blocks 10x10x10cm. of 1:2:4 mix (1 cement : 2 coarse : 4 graded stone aggregate 20mm nominal size). Including cost of cutting holes & making good the walls etc. b) for 100mm dia pipe. DSR 17.37.1

133

266

35378

... More
Providing & fixing M.S. holder bat clamps of approved design to sand cast iron/centrifugally cast (Spun) iron S & S pipe embeded in & including cement concrete blocks 10x10x10cm. of 1:2:4 mix (1 cement : 2 coarse : 4 graded stone aggregate 20mm nominal size). Including cost of cutting holes & DSR 17.37.2

143

264

37752

... More
Providing and laying cement concrete 1:5:10(1 cement : 5 coarse sand : 10 graded stone aggregate 20mm nominal size) around P.V.C Soil and waste pipe including bed concrete as per standard design(embedded in the flooring / ground) 100 mm dia

70

709

49630

... More
Providing and laying cement concrete 1:5:10(1 cement : 5 coarse sand : 10 graded stone aggregate 20mm nominal size) around P.V.C Soil and waste pipe including bed concrete as per standard design(embedded in the flooring / ground) 75 mm dia

70

433

30310

... More
Providing & fixing cast iron trap of self cleansing design with or without ventarm complete, including cost of cutting & making good the walls & floors. a) 100mm inlet & 75mm outlet.

112

1451

162512

... More
Providing & fixing cast iron coller. a) for 100mm dia pipe.

167

377

62959

... More
Providing & fixing cast iron coller. b) 75mm dia.

175

266

46550

... More
Providing and fixing plain cast iron S & S sanitary bend. a) 100mm

39

418

16302

... More
Providing and fixing plain cast iron S & S sanitary bend. b) 75mm

35

287

10045

... More
Providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete. a) 100mm

1

518

518

... More
Providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete. b) 75mm

2

384

768

... More
Providing and fixing centrifugaly cast iron single equal plain junction of required degree. 17.44.1.2 100x100x100mm

24

596

14304

... More
Providing and fixing centrifugaly cast iron single equal plain junction of required 75x75x75mm

26

412

10712

... More
Providing and fixing cast iron terminal guard. 17.56.1.2 100 mm

13

371

4823

... More
Providing and fixing cast iron terminal guard. 17.56.1.2 75 mm

15

297

4455

... More
Providing and fixing on wall face unplasticised- Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion. 110 mm

391

277

108307

... More
Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion. Bend 87.5 degree

18

110

1980

... More
Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion. Shoe (Plain) 110 mm Shoe

10

196

1960

... More
Providing and fixing unplasticised-PVC pipe clips of approved design to unplasticised-PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with MS screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm

101

272

27472

... More
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement,punning,rounding the edges and making and finishing the outlet complete.

11

219

2409

... More
Providing & fixing G.I. pipes complete with G.I. fittings & clamps including cutting & making good the walls etc. internal work a) 25mm dia nominal bore (medium duty)

410

405

166050

... More
Providing & fixing G.I. pipes complete with G.I. fittings & clamps including cutting & making good the walls etc. internal work b) 32mm dia nominal bore (medium duty)

285

490

139650

... More
Providing & fixing G.I. pipes complete with G.I. fittings & clamps including cutting & making good the walls etc. internal work c) 40mm dia nominal bore (medium duty)

210

596

125160

... More
Concealed pipe including painting with anticorrosive bitumatic paint, cutting chases and making good the wall. a) 15mm dia nominal bore

295

426

125670

... More
Concealed pipe including painting with anticorrosive bitumatic paint, cutting chases and making good the wall. b) 20mm dia nominal bore

250

466

116500

... More
Painting G.I. pipes and fittings with two coats of anti corrosive bitumastic paint of approved quality.a) 15mm dia nominal bore.

295

8

2360

... More
Painting G.I. pipes and fittings with two coats of anti corrosive bitumastic paint of approved quality.b) 20mm dia nominal bore.

250

10

2500

... More
Painting G.I. pipes and fittings with two coats of anti corrosive bitumastic paint of approved quality.c) 25mm dia nominal bore.

410

13

5330

... More
Painting G.I. pipes and fittings with two coats of anti corrosive bitumastic paint of approved quality.d) 32mm dia nominal bore.

285

16

4560

... More
Painting G.I. pipes and fittings with two coats of anti corrosive bitumastic paint of approved quality.e) 40mm dia nominal bore.

210

18

3780

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. (internal work). 15mm dia nominal bore

360

210

75600

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. (internal work).20mm dia nominal bore

355

246

87330

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. (internal work).25mm dia nominal bore

233

295

68735

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. (internal work). 32mm dia nominal bore

47

381

17907

... More
Providing and fixing GI Union in GI pipes including cutting and threading the pipe and making long screws etc. complete (new work).15mm dia nominal bore

21

233

4893

... More
Providing and fixing GI Union in GI pipes including cutting and threading the pipe and making long screws etc. complete (new work).20mm dia nominal bore

15

254

3810

... More
Providing and fixing GI Union in GI pipes including cutting and threading the pipe and making long screws etc. complete (new work). 25mm dia nominal bore

12

322

3864

... More
Providing and fixing GI Union in GI pipes including cutting and threading the pipe and making long screws etc. complete (new work). 32mm dia nominal bore

5

359

1795

... More
Providing and fixing gun metal gate valve with wheel of approved quality. 25mm dia nominal bore

44

457

20108

... More
Providing and fixing gun metal gate valve with wheel of approved quality. 32mm dia nominal bore

36

506

18216

... More
Providing and fixing brass stop cock of approved quality.a) 15 mm nominal bore

3

259

777

... More
Providing and fixing brass stop cock of approved quality. b) 20 mm nominal bore

22

278

6116

... More
Providing and placing on terrace (at all floor levels)polyethylene water storage tank ISI : 12701 marked indicating the BIS License No. with cover and suitable locking arrangement and making necessary holes for inlet, outlet and over flow pipes but without fitting and base support for tank.[Sintex, Electroplast, Star, Lotus or equivalent having valid ISI license]. Capcity in Per Liters

22500

8

180000

... More
Excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth including consolidating Nos. deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed, within a lead of 50m. All kinds of soil. Pipes, cables etc. exceeding 80mm dia but not exceeding 300mm.

293

258

75594

... More
Providing, laying and jointing glazed stoneware pipes grade 'A' with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete. 100mm diameter

149

326

48574

... More
Providing, laying and jointing glazed stoneware pipes grade 'A' with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete. 150mm diameter

174

511

88914

... More
Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) all round S.W. pipes including bed concrete as per standard design 100mm dia SW pipe

149

709

105641

... More
Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) all round S.W. pipes including bed concrete as per standard design 150mm dia SW pipe

224

867

194208

... More
Providing and fixing square-mouth S.W. gully trap grade‘A’ complete with C.I. grating, brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design. With Sewer bricks conforming to IS :4885 150 x 100 mm size P type

25

1993

49825

... More
19.7 Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design. 19.7.1 Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg). With FPS bricks of class designation 75

23

9386

215878

... More
Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement:3 coarse sand :6graded stone aggregate 20 mm nominal size) as per standard design With 20x20 mm square bar

16

400

6400

... More
Providing and fixing PTMT towel rail complete with brackets fixed towooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms.

16

521

8336

... More
Providing and Fixing C.P. brass Ablution health faucet assembly with 1.2 m long braided PVC hose with mounting bracket fixed on wall complete.[FOR EWC]

22

500

11000

... More
Providing and fixing C.P. brass Two-way angle valve for EWC points & for fixing Ablution Health Fauct of approved quality conforming to IS:8931. 15 mm nominal bore

22

750

16500

... More
Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement:3 coarse sand :6graded stone aggregate 20 mm nominal size) as per standard design With 20x20 mm square bar

10

6486

64860

... More
Providing and fixing PTMT towel rail complete with brackets fixed towooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms.

20

400

8000

... More
Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge.

4

256

1024

... More
Providing and fixing PTMT soap Dish Holder having length of 138mm,breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms.

28

81

2268

... More
Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge.

1

81

81

... More
Providing and fixing C.P. brass Two-way angle valve for EWC points & for fixing Ablution Health Fauct of approved quality conforming to IS:8931. 15 mm nominal bore

4

1400

5600

... More
Providing & fixing Jaquar make C.P. brass bottle trap.

4

1050

4200

... More
Boring/ Tubewell Transportation, Erection Dismantling of Rig Machine

1

32680

32680

... More
Drilling of Borehole for Tubewell construction by DC/RC/DTH Rig Machine including transportation, erection, dismantling of Rig and assosisted T&P complete in all respect including required all material. labour etc. Transportation, Erection Dismantling of Rig machine. (i)DC/RC Drilling up to 100Mtr. Deep 600 mm dia

100

2290

229000

... More
Drilling of Borehole for Tubewell construction by DC/RC/DTH Rig Machine including transportation, erection, dismantling of Rig and assosisted T&P complete in all respect including required all material. labour etc. Transportation, Erection Dismantling of Rig machine. (ii)DC/RC Drilling from 101 to 200 Mtr. Deep 600 mm dia

60

2620

157200

... More
M.S. tubewell assembly with all required parts like plain pipe,sltted pipe (as required up50% of plain pipes) rings,well cap,bail plug,clamp reducer,central guide,support structure etc.as required & as per typed design complete in all respect (Note-Axial length of reducers without ring shall be measured with casing PIpe) (Rate Effectiv 35 % later nos 100/110,ce/( 2062-0087)/22 Dated 20/05.2022 (i)300 mm. dia housing pipe (6 mm. thick) (Rs.

60

5386

323160

... More
M.S. tubewell assembly with all required parts like plain pipe,sltted pipe (as required up50% of plain pipes) rings,well cap,bail plug,clamp reducer,central guide,support structure etc.as required & as per typed design complete in all respect (Note-Axial length of reducers without ring shall be measured with casing PIpe) (Rate Effectiv 35 % later nos 100/110,ce/( 2062-0087)/22 Dated 20/05.2022 (ii)200 mm. dia housing pipe (6 mm. thick)

48

3726

178848

... More
M.S. tubewell assembly with all required parts like plain pipe,sltted pipe (as required up50% of plain pipes) rings,well cap,bail plug,clamp reducer,central guide,support structure etc.as required & as per typed design complete in all respect (Note-Axial length of reducers without ring shall be measured with casing PIpe) (Rate Effectiv 35 % later nos 100/110,ce/( 2062-0087)/22 Dated 20/05.2022 (iii)200 mm. dia Slotted pipe (6 mm. thick)

30

2808

84240

... More
Lowering of tubewell assembly duly welded including welding electrode and shrouding of Pea Gravel Complete in all respect. (i)300 mm. dia housing pipe

60

370

22200

... More
Lowering of tubewell assembly duly welded including welding electrode and shrouding of Pea Gravel Complete in all respect. (ii)200 mm. dia M.S. pipe

48

250

12000

... More
Lowering of tubewell assembly duly welded including welding electrode and shrouding of Pea Gravel Complete in all respect. (iii)200 mm. dia Slotted M.S. pipe

30

310

9300

... More
SITC of Main Piping & Valves with 24 mtr. Column pipe, Electronic type Chlorinating plant Power wiring, earthing, Printing, Tools sets, wiring of pump house (internal & External) Chain Pulley block and gauges complete in all respect with all required material, T&P labou,3Mtr. Long heavy duty Column Pipe same as above (spare)

1

220380

220380

... More
Supplying, filling, spreading & leveling pea gravel (Kanpur Zone)

35

5200

182000

... More
Transportation, Installation & Dismantling of 600 PSI Compressor.

1

28320

28320

... More
Charges of Development by 600 PSI Compressor per Hr.

64

3890

248960

... More
Charges for Development of Tube Well by 1 cuses O.P. Unit .

120

650

78000

... More
SITC of Pumping plant including starter, control Panal, cable, complete in all respect with all required material T&P labour etc.[ 15 H.P.]

1

256520

256520

... More
Logging of bore hole by departmental / approved electric logger.

1

18000

18000

... More
Supply and wiring of 3 number 6 sq. mm. PVC insulated 1100 V grade single core Copper conductor cable in 40 mm dia PVC conduit partly concealed in wall and partly laid in slab alongwith reinforcement before concreting, with two number 10 sq mm single core Copper conductor cable as earth continuity wiredrawn in coudit including matching colour wash etc, complete in all respect. (PWD -232B)

120

353

42360

... More
Water Supply of tanker 5000 litre capacity of boring. DSR 7763-14.05%

100

1194

119400

... More
Excavating trenches in all kinds of soil of required width for pipes. including excavation for sockets and dressing of sides, ramming of bottoms, including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating Nos. deposited layer by ramming, watering, etc & disposing of surplus excavated soil as directed. up to 1.50 m depth. Pipes 80 mm to 300 mm diameter

180

258

46440

... More
Excavating trenches in all kinds of soil of required width for pipes. including excavation for sockets and dressing of sides, ramming of bottoms, including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating Nos. deposited layer by ramming, watering, etc & disposing of surplus excavated soil as directed. 1.50 m to 3.00 m depth. Pipes 80 mm to 300 mm diameter

30

318

9540

... More
Open timbering in trenches including shuttering and shoring complete. (Measurement to be taken of the face area timbered). Depth not exceeding 1.5 meter

150

52

7800

... More
Open timbering in trenches including shuttering and shoring complete. (Measurement to be taken of the face area timbered). Depth 1.5 to 3.00 meter

30

59

1770

... More
Providing Laying and jointing glazed stone ware pipes grade . 150mm diameter

168.5

511

86103.5

... More
Providing & laying cement concrete 1:5:10 (1 cement :5 coarse sand :10 graded stone aggregate 40mm nominal size) alround S.W. Pipes including bed concrete as per standard design. 150mm diameter

168.5

867

146089.5

... More
Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of 19.7.1With common burnt clay FPS (non modular) bricks of class designation 75 frame 15kg). 19.7.1.1 (i) For Sewer Line Extra for depth for manholes:

20

9386

187720

... More
Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard Inside size 90x80cms and 45cms deep including CI cover with frame . Size 90x80cm with With common burnt clay FPS (non modular) bricks of class designation 7.5

12.5

6486

81075

... More
Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard Inside size 90x80cms and 45cms deep including CI cover with frame . Inside size 90x120cms and 90cms deep including CI cover with frame (MEDIUM duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58kg). With common burnt clay FPS (non modular) bricks of class designation 75(i) For Sewer Line

3

19408

58224

... More
Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard Inside size 90x80cms and 45cms deep including CI cover with frame Size 90x120cm with With common burnt clay FPS (non modular) bricks of class designation 7.5 Extra for depth for manholes:

1.2

7780

9336

... More
Providing orange colour safety foot rests of minimum 6 mm thick plastic encapsulated as per IS:10910 on 12 mm dia steel bar conforming to IS:1786 having minimum cross section as 23 mm x 25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm thread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.

18

406

7308

... More
Providing & fixing G.I. pipes complete with G.I. fittings including tenching and refilling etc. (external work) 65mm nominal bore.

150

659

98850

... More
Providing & fixing G.I. pipes complete with G.I. fittings including tenching and refilling etc. (external work) 50mm nominal bore.

120

560

67200

... More
Providing & fixing G.I. pipes complete with G.I. fittings including tenching and refilling etc. (external work) 40mm nominal bore.

250

453

113250

... More
Providing & fixing G.I. pipes complete with G.I. fittings including tenching and refilling etc. (external work) 32mm nominal bore.

15

397

5955

... More
Providing & fixing G.I. pipes complete with G.I. fittings including tenching and refilling etc. (external work) 25mm nominal bore.

40

343

13720

... More
Supplying and fixing of specials for pressure pipe.

1

29916

29916

... More
Providing and fixing gate valve (with cap complete with bolts, nuts, rubber insertion etc. 50mm nominal bore.

2

754

1508

... More
Providing and fixing gate valve (with cap complete with bolts, nuts, rubber insertion etc. 40mm nominal bore.

7

607

4249

... More
Providing and fixing gate valve (with cap complete with bolts, nuts, rubber insertion etc. 32mm nominal bore.

2

506

1012

... More
Providing and fixing gate valve (with cap complete with bolts, nuts, rubber insertion etc. 25mm nominal bore.

5

396

1980

... More
Constructing brick masonry chamber 600 x 600 x 750 mm inside with F.P.S. brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for Sluice Valve / Air Valve, with C. I. surface box 100 mm top diameter, 160 mm bottom diameter and 180mm deep (inside) with chained lid and RCC top slab with 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4 grade stone aggregate 20 mm nominal size); necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand: 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1 : 3 (1 cement : 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design

12

7983

95796

... More
R.c.c. work with cement approved coarse sand and 2 cm. (3/4") guage approved stone ballast in the proportion 1:6,(1 cement :6 aggregate) in lintels of doors and windows excluding supply of reinforcement and its fixing and binding the same with 24 B WG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. strength of the concrete shall not beless than M-20. (PWD-283) 1:1.5:3 MIX. As in item 3 above but for slabs +0 LVL Same as item no. 5 but for +3000 LVL

0.56

8456

4735.36

... More
R.c.c. work with cement approved coarse sand and 2 cm. (3/4") guage approved stone ballast in the proportion 1:6,(1 cement :6 aggregate) in lintels of doors and windows excluding supply of reinforcement and its fixing and binding the same with 24 B WG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. strength of the concrete shall not beless than M-20. (PWD-283) 1:1.5:3 MIX. As in item 3 above but for slabs +0 LVL Same as item no. 5 but for +6000 LVL

0.56

8456

4735.36

... More
R.c.c. work with cement approved coarse sand and 2 cm. (3/4") guage approved stone ballast in the proportion 1:6,(1 cement :6 aggregate) in lintels of doors and windows excluding supply of reinforcement and its fixing and binding the same with 24 B WG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. strength of the concrete shall not beless than M-20. (PWD-283) 1:1.5:3 MIX. As in item 3 above but for slabs +0 LVL Same as item no. 5 but for at +9000 LVL.

0.56

8541

4782.96

... More
R.c.c. work with cement approved coarse sand and 2 cm. (3/4") guage approved stone ballast in the proportion 1:6,(1 cement :6 aggregate) in lintels of doors and windows excluding supply of reinforcement and its fixing and binding the same with 24 B WG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. strength of the concrete shall not beless than M-20. (PWD-283) 1:1.5:3 MIX. As in item 3 above but for slabs +0 LVL Same as item no. 5 but for +12000 LVL

0.56

8626

4830.56

... More
R.c.c. work with cement approved coarse sand and 2 cm. (3/4") guage approved stone ballast in the proportion 1:6,(1 cement :6 aggregate) in lintels of doors and windows excluding supply of reinforcement and its fixing and binding the same with 24 B WG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. strength of the concrete shall not beless than M-20. (PWD-283) 1:1.5:3 MIX. As in item 3 above but for slabs +0 LVL Same as item no. 5 but for at +15000 LVL.

0.56

8712

4878.72

... More
R.c.c. work with cement approved coarse sand and 2 cm. (3/4") guage approved stone ballast in the proportion 1:6,(1 cement :6 aggregate) in lintels of doors and windows excluding supply of reinforcement and its fixing and binding the same with 24 B WG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. strength of the concrete shall not beless than M-20. (PWD-283) 1:1.5:3 MIX. As in item 3 above but for slabs +0 LVL Same as item no. 5 but for at +18000 LVL.

0.56

8799

4927.44

... More
R.c.c. work with cement approved coarse sand and 2 cm. (3/4") guage approved stone ballast in the proportion 1:6,(1 cement :6 aggregate) in lintels of doors and windows excluding supply of reinforcement and its fixing and binding the same with 24 B WG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. strength of the concrete shall not beless than M-20. (PWD-283) 1:1.5:3 MIX. As in item 3 above but for slabs +0 LVL Same as item no. 5 but for at +20000 LVL.

2.34

8887

20795.58

... More
R.c.c. work with cement approved coarse sand and 2 cm. (3/4") guage approved stone ballast in the proportion 1:6,(1 cement :6 aggregate) in lintels of doors and windows excluding supply of reinforcement and its fixing and binding the same with 24 B WG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. strength of the concrete shall not beless than M-20. (PWD-283) 1:1.5:3 MIX. As in item 3 above but for slabs +0 LVL Same as item no. 5 but for above +20000 lvl

7.41

8976

66512.16

... More
R.c.c. work with cement approved coarse sand and 2 cm. (3/4") guage approved stone ballast in the proportion 1:6,(1 cement :6 aggregate) in lintels of doors and windows excluding supply of reinforcement and its fixing and binding the same with 24 B WG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. strength of the concrete shall not beless than M-20. (PWD-283) 1:1.5:3 MIX. As in item 3 above but for slabs +0 LVL. for the lighter beams for +3000 LVL

1.19

8456

10062.64

... More
R.c.c. work with cement approved coarse sand and 2 cm. (3/4") guage approved stone ballast in the proportion 1:6,(1 cement :6 aggregate) in lintels of doors and windows excluding supply of reinforcement and its fixing and binding the same with 24 B WG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. strength of the concrete shall not beless than M-20. (PWD-283) 1:1.5:3 MIX. As in item 3 above but for slabs +0 LVL. for the lighter beams for +6000 LVL

1.19

8456

10062.64

... More
R.c.c. work with cement approved coarse sand and 2 cm. (3/4") guage approved stone ballast in the proportion 1:6,(1 cement :6 aggregate) in lintels of doors and windows excluding supply of reinforcement and its fixing and binding the same with 24 B WG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. strength of the concrete shall not beless than M-20. (PWD-283) 1:1.5:3 MIX. As in item 3 above but for slabs +0 LVL. for the lighter beams for + 9000 LVL

1.19

8541

10163.79

... More
R.c.c. work with cement approved coarse sand and 2 cm. (3/4") guage approved stone ballast in the proportion 1:6,(1 cement :6 aggregate) in lintels of doors and windows excluding supply of reinforcement and its fixing and binding the same with 24 B WG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. strength of the concrete shall not beless than M-20. (PWD-283) 1:1.5:3 MIX. As in item 3 above but for slabs +0 LVL. for the lighter beams for + 12000 LVL

1.19

8626

10264.94

... More
R.c.c. work with cement approved coarse sand and 2 cm. (3/4") guage approved stone ballast in the proportion 1:6,(1 cement :6 aggregate) in lintels of doors and windows excluding supply of reinforcement and its fixing and binding the same with 24 B WG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. strength of the concrete shall not beless than M-20. (PWD-283) 1:1.5:3 MIX. As in item 3 above but for slabs +0 LVL. for the lighter beams for + 15000 LVL To

1.19

8712

10367.28

... More
R.c.c. work with cement approved coarse sand and 2 cm. (3/4") guage approved stone ballast in the proportion 1:6,(1 cement :6 aggregate) in lintels of doors and windows excluding supply of reinforcement and its fixing and binding the same with 24 B WG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. strength of the concrete shall not beless than M-20. (PWD-283) 1:1.5:3 MIX. As in item 3 above but for slabs +0 LVL. for the lighter beams for + 18000 LVL To

1.19

8799

10470.81

... More
R.c.c. work with cement approved coarse sand and 2 cm. (3/4") guage approved stone ballast in the proportion 1:6,(1 cement :6 aggregate) in lintels of doors and windows excluding supply of reinforcement and its fixing and binding the same with 24 B WG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. strength of the concrete shall not beless than M-20. (PWD-283) 1:1.5:3 MIX. As in item 3 above but for slabs +0 LVL. for the lighter beams for + 20000 LVL To

1.74

8887

15463.38

... More
R.c.c. work with cement approved coarse sand and 2 cm. (3/4") guage approved stone ballast in the proportion 1:6,(1 cement :6 aggregate) in lintels of doors and windows excluding supply of reinforcement and its fixing and binding the same with 24 B WG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. strength of the concrete shall not beless than M-20. (PWD-283) 1:1.5:3 MIX. As in item 3 above but for slabs +0 LVL. for the lighter beams for above +20000 lvl.

0.6

8976

5385.6

... More
R.c.c. work with cement approved coarse sand and 2 cm. (3/4") guage approved stone ballast in the proportion 1:6,(1 cement :6 aggregate) in lintels of doors and windows excluding supply of reinforcement and its fixing and binding the same with 24 B WG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. strength of the concrete shall not beless than M-20. (PWD-283) 1:1.5:3 MIX. As in item 3 above but for slabs +0 LVL. R.C.C. Raft foundation and footing with approved stone ballast.

9.53

6648

63355.44

... More
R.c.c. work with cement approved coarse sand and 2 cm. (3/4") guage approved stone ballast in the proportion 1:6,(1 cement :6 aggregate) in lintels of doors and windows excluding supply of reinforcement and its fixing and binding the same with 24 B WG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. strength of the concrete shall not beless than M-20. (PWD-283) 1:1.5:3 MIX. As in item 3 above but for slabs +0 LVL. R.C.C. columns in1:1.5:3having strength not less than M'-20. for +3000 LVL

1.6

7976

12761.6

... More
R.c.c. work with cement approved coarse sand and 2 cm. (3/4") guage approved stone ballast in the proportion 1:6,(1 cement :6 aggregate) in lintels of doors and windows excluding supply of reinforcement and its fixing and binding the same with 24 B WG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. strength of the concrete shall not beless than M-20. (PWD-283) 1:1.5:3 MIX. As in item 3 above but for slabs +0 LVL. R.C.C. columns in1:1.5:3having strength not less than M'-20. for +6000 LVL

1.06

7976

8454.56

... More
R.c.c. work with cement approved coarse sand and 2 cm. (3/4") guage approved stone ballast in the proportion 1:6,(1 cement :6 aggregate) in lintels of doors and windows excluding supply of reinforcement and its fixing and binding the same with 24 B WG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. strength of the concrete shall not beless than M-20. (PWD-283) 1:1.5:3 MIX. As in item 3 above but for slabs +0 LVL. R.C.C. columns in1:1.5:3having strength not less than M'-20. for + 9000 LVL

1.06

8056

8539.36

... More
R.c.c. work with cement approved coarse sand and 2 cm. (3/4") guage approved stone ballast in the proportion 1:6,(1 cement :6 aggregate) in lintels of doors and windows excluding supply of reinforcement and its fixing and binding the same with 24 B WG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. strength of the concrete shall not beless than M-20. (PWD-283) 1:1.5:3 MIX. As in item 3 above but for slabs +0 LVL. R.C.C. columns in1:1.5:3having strength not less than M'-20. for + 12000 LVL

1.06

8137

8625.22

... More
R.c.c. work with cement approved coarse sand and 2 cm. (3/4") guage approved stone ballast in the proportion 1:6,(1 cement :6 aggregate) in lintels of doors and windows excluding supply of reinforcement and its fixing and binding the same with 24 B WG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. strength of the concrete shall not beless than M-20. (PWD-283) 1:1.5:3 MIX. As in item 3 above but for slabs +0 LVL. R.C.C. columns in1:1.5:3having strength not less than M'-20. for + 15000 LVL To

1.06

8218

8711.08

... More
R.c.c. work with cement approved coarse sand and 2 cm. (3/4") guage approved stone ballast in the proportion 1:6,(1 cement :6 aggregate) in lintels of doors and windows excluding supply of reinforcement and its fixing and binding the same with 24 B WG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. strength of the concrete shall not beless than M-20. (PWD-283) 1:1.5:3 MIX. As in item 3 above but for slabs +0 LVL. R.C.C. columns in1:1.5:3having strength not less than M'-20. for + 18000 LVL To

1.06

8300

8798

... More
R.c.c. work with cement approved coarse sand and 2 cm. (3/4") guage approved stone ballast in the proportion 1:6,(1 cement :6 aggregate) in lintels of doors and windows excluding supply of reinforcement and its fixing and binding the same with 24 B WG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. strength of the concrete shall not beless than M-20. (PWD-283) 1:1.5:3 MIX. As in item 3 above but for slabs +0 LVL. R.C.C. columns in1:1.5:3having strength not less than M'-20. for + 20000 LVL To

1.06

8383

8885.98

... More
Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in anover all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. for +3000 LVL

17.42

7926

138070.92

... More
Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in anover all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. for +6000 LVL

4.34

7926

34398.84

... More
Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in anover all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. for + 9000 LVL

4.39

8006

35146.34

... More
Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in anover all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. for + 12000 LVL

4.2

8086

33961.2

... More
Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in anover all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. for + 15000 LVL To

4.2

8167

34301.4

... More
Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in anover all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. for + 18000 LVL To

7.08

8248

58395.84

... More
Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in anover all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. for + 20000 LVL To

10.65

8331

88725.15

... More
Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in anover all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. M.S.Work in railing

1440

161

231840

... More
Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineerin- charge .The elevational area of the scaffolding shall be measured for payment purpose .The payment will be made once irrespective of duration of scaffolding.

291.52

248

72296.96

... More
Providing and fixing G.I.pipes complete with G.I. fitting and clamps including cuttingand making good the walls. 40 mm dia nominal bore (inlet)

50

596

29800

... More
Providing and fixing G.I.pipes complete with G.I. fitting and clamps including cuttingand making good the walls. 65 mm dia nominal bore (outlet)

30

659

19770

... More
Providing and fixing G.I.pipes complete with G.I. fitting and clamps including cuttingand making good the walls. 40 mm dia nominal bore (wash out)

25

596

14900

... More
Providing and fixing G.I.pipes complete with G.I. fitting and clamps including cuttingand making good the walls. 65 mm dia nominal bore (overflow)

30

659

19770

... More
Painting G.I. pipes and fittting with synthetic enamel white paint over a ready mixed priming coat, both of approved quality for new work 40 mm dia nominal bore

70

31

2170

... More
Painting G.I. pipes and fittting with synthetic enamel white paint over a ready mixed priming coat, both of approved quality for new work 65 mm dia nominal bore

60

37

2220

... More
providing and fixing gun metal gate valve with C I wheels of approved quality (screwed ends). 40 mm dia nominal bore

2

607

1214

... More
providing and fixing gun metal gate valve with C I wheels of approved quality (screwed ends). 65 mm dia nominal bore

2

1280

2560

... More
Supply and burying of 600mm x 600 mmx6mm G.I. plate, vertically for earthing with its top atleast 3 mts. below ground level complete with 20mm G.I.pipe and funnel for watering and two earthing leads of No.8to10SWG G.I.wire in 15mm diaG.I. pipe upto switch board (from apron to switch board the cost of G.I. pipe and G.I. wire will be extra) 30cm. square C.I. frame with hinged cover, masonary housing, alternate layers/of charcoal/ coke and salt at least 150mm thick alround etc. complete in all respects.

1

4042

4042

... More
Supplying & Laying of 25mmx3mm G.I. Strip for earthing purpose as required complete in all respects.

60

73

4380

... More
Supply & fixing of two number 8 SWG G.I. wire for earthing purpose as required complete in all respects.

80

183

14640

... More
M-150 brick work in 1:4 (one cement and six coarse sand sand of 1.25 fineness modulus) mortar in foundation & plinth including supply of all materials, labour and T & P etc required for proper completion of the work. As per S.I. No. PWD-305

209.2

5417

1133236.4

... More
Class 150 brick work in 1:6 (one cement and six coarse sand sand of 2.25 fineness modulus) mortar in foundation & plinth including supply of all materials, labour and T & P etc required for proper completion of the work. As per Dsr 6.1.2

51

5242

267342

... More
Fe-500 Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level.

133.14

79

10518.06

... More
15 mm cement plaster 1:4 in single coat on rough side of single or half brick wall for interior plastering rp to floor two level including internal rounded angles not exceeding 80 mm in girth and finished even and smooth.

993.87

302

300147.23

... More
Providing M.S. foot rest including fixing with 20x20x10 cm. cement concrete block 1:3:6 as per standered design with 20x20 mm sq bars. As per DSR 19.15.1

25

400

10000

... More
Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality M.D.-10 circular shape 500 mm internal diameter as per DSR 19.19.3.1

2

1231

2462

... More
Boring/Drilling bore well of required dia for casing/strainer pipe, by suitable method prescribed in IS:2800(part-1), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 meter depth below ground level, drilling of 30 mm dia bore hoe manually, As per DSR 23.1.1.1

60

520

31200

... More
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs conforming to I.S. 12818. including hire & labour charges, fittings and acessories etc. all complete, for all depths, as per direction of Engineer in charge as per DSR 23.4.2 (150 mm nominal size dia)

60

593

35580

... More
Suppling, filling, spreading and levelling stone boulders of size range 5 cm to 20 cm in recharge pit, in the required thickness, for all leads and lifts, all complete as per direction of Engineer in charge as per DSR 23.5 (22.4-53 mm)

7.06

1109

7829.54

... More
Suppling, filling, spreading and levelling stone boulders of size range 5 cm to 10 cm in recharge pit, in the required thickness, for all leads and lifts, all complete as per direction of Engineer in charge as per DSR 23.6 (5-10 mm)

7.06

1130

7977.8

... More
Suppling, filling, spreading and levelling stone boulders of size range 1.5 mm to 2 mm in recharge pit, in the required thickness, for all leads and lifts, all complete as per direction of Engineer in charge as per DSR 23.7 (1.5-2.00 mm )

7.06

1130

7977.8

... More
Gravel packing in tubewell construction in accordance with IS;4097, including providing gravel fine/medium/ coarse in required grading and sizes as per actual requirement, all complete as per direciton of Engineer in charge as per DSR no 23.8

4

1488

5952

... More
Construction masonary chamber 60x60x75 cm inside, in brickwork in cement mortar 1:4 for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix i/c necessary excavation, foundation concrete 1:5:10 and inside plastering with 12 mm thick cement mortar 1:3 finished with a floating coat of neat cement complete as per standard design with common burnt clay F.P.S. brick class designation 7.5 as per DSR No 18.33.1

35

7983

279405

... More
Excacating trenches in all kind of soil required for pipes, including excavation for sockets and dressing of sides, ramming of bottoms, including getting out the excavated soil and then retruning the sil as required, in lahyers not exceeding 20 cm in depth including consolidating Nos. deposited layer by ramming, watering, etc and disposing of surplus excavated soil as directed within a lead of 50 m upto 1.50 m depth pipes 80 mm to 300 mm dia meter as per DSR 2.10.1.2

550

258

141900

... More
Providing and laying non pressure NP-2 class (light duty) RCC pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including of joints etc. complete 150 mm diameter RCC pipes DSR 19.6.1

550

408

224400

... More
Providing and laying cement concrete 1:5:10 (1 cement :5 coarse sand :10 graded Stone aggregate 40 mm nominal size) alround S.W. pipes including bed concrete as per standard design 150 mm diameter. As per DSR 19.2.2

550

867

476850

... More
Uprooting rank vegetation and weeds by digging the area to a depth of 60 cm, removing all weeds and other growth with roots by forking repeatedly, breaking clods, rough dressing, flooding with water, uprooting fresh growths after 10 to 15 days and then fine dressing for planting new grass, including disposal of all rubbish with all leads and lifts

1600

58

92800

... More
Trenching in ordinary soil up to a depth of 60 cm including removal and stacking of serviceable materials and then disposing of surplus soil, by spreading and neatly leveling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or / and manure before and after flooding trench with water (excluding cost of imported earth, sludge or manure).

480

75

36000

... More
Supplying and stacking at site dump manure from approved source including carriage upto 1 km (manure measured in stacks will be reduced by 8% for payment) : Screened through sieve of I.S. designation 4.75 mm.

160

308

49280

... More
Spreading of sludge, dump manure or/and good earth in required thickness (cost of sludge dump manure or/and good earth to be paid separately).

160

50

8000

... More
Carrigae of manure upto 5 K.M.

320

180

57600

... More
Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge.

320

35

11200

... More
Preparation of beds for hedging and shrubbery by excavating 60 cm deep and trenching the excavated base to a further depth of 30 cm, refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8:1 (8 parts of stacked volume of earth after reduction by 20% : one part of stacked volume of sludge or manure after reduction by 8%), flooding with water, filling with earth if necessary, watering and finally fine dressing, leveling etc. including stacking and disposal of materials declared unserviceable and surplus earth by spreading and leveling as directed, within a lead of 50 m, lift up to 1.5 m complete (cost of sludge, manure or extra earth to be paid for separately)

240

214

51360

... More
Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) Holes 90 cm dia, and 90 cm deep

90

137

12330

... More
Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) Holes 60 cm dia, and 60 cm deep

120

42

5040

... More
Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) Holes 45 cm dia, and 45 cm deep.

240

18

4320

... More
Anti termite treatment by digging holes 30 cm deep and 4 cm dia, 6 to 7 holes around the tree using chemical emulsion at the rate of 1.5 liter per hole in two time or more application to get the trees free from termite infection chemicals used Chlorpyriphos 20% EC in the ratio of 1% concentration and as per direction of officer-in-charge.

450

49

22050

... More
Providing and stacking of Bottle palm of ht. 210-240 cm bottom girth 30-35 cm well developed in big HDPE bags.

120

337

40440

... More
Providing and stacking of Adansonia digitata (kalp vricksh) of ht 150-165 cm in bag size of 25 cm as per direction of the officer-in-charge.

90

255

22950

... More
Providing and stacking of Fishtail palm of ht. 270-300 cm bottom girth 40-50 cm well developed in big size HDPE bags as per direction of the officer-in-charge.

120

529

63480

... More
Providing and stacking of Ficus benjamina (green) of height 150-165 cm., bushy with healthy branches and lush green foliage in big size HDPE bags as per direction of the officer-in-charge.

120

173

20760

... More
Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50 mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 80 mm thick C.C. paver block of M-35 grade with approved colour design and pattern..

333.97

802

267843.94

... More
Providing and laying design mix cement concrete of M-30 grade, in roads/ taxi tracks/ runways, using cement content as per design mix, using coarse sand and graded stone aggregate of 40 mm nominal size in appropriate proportions as per approved & specified design criteria, providing dowel bars with sleeve/ tie bars wherever required, laying at site, spreading and compacting mechanically by using needle and surface vibrators, levelling to required slope/ camber, finishing with required exture, including steel form work with sturdy M.S. channel ections, curing, making provision for contraction/ expansion, construction & longitudinal joints (10 mm wide x 50 mm deep) by groove cutting machine, providing and filling joints with approved joint filler and sealants, complete all as per direction of ngineerin- charge (Item of joint fillers, sealants, dowel bars with sleeve/ tie bars to be paid separately). Cement concrete manufactured in automatic batching plant (RMC plant) including transportation to site in transit mixer

102

8157

832014

... More
Providing and laying in position bitumen hot sealing compound for expansion joints etc. Using grade 'A' sealing compound.

202

6

1212

... More
Cost of Trimixing of floor

676

147

99372

... More
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard

405

126

51030

... More
Supply and burying earth electode for lightining conductor of 900mmx900mm x 6.0mm G.I. Plate vertically for earthing with its top at least 3 Metres below ground level complete with 20mm G.I.Pipe for watering funnel, 30cm square C.I. Frame with hinged cover masonry housing alternate layers of chorcoal / coke and salt at least 150mm thick alround etc. complete in all respects.

2

6610

13220

... More
Supply and fixing of horizontal air termination (roof conductor )of 25mm x 3mm G.I. Strip, G.I. Clamps on surface complete in all respects as approved by Engineer - in - charge.

35

150

5250

... More
(A) Supply and fixing of vertical air termination final rod comprising of 300 mm long x 25 mm dia. Copper rod with one pointed prong and 100mm dia. x 3mm thick base plate etc. complete in all respects. (B) As in Item 712 (A) but with G.I. Material.

1

1235

1235

... More
Supply and fixing of vertical down conductor of 32mm x 6mm G.I.Strip etc. on approved clamps on surface for lightning conductor complete in all respects ( for two storeyed Buildings) As in item 713 ( A ) but for three or four storeyed building

48

245

11760

... More
Supply and laying of 35mm x 3mm G.I. Strip from earth electrode directly in the ground as required complete in all respects.

12

145

1740

... More
Supply and fixing of testing joint of G.I. Strip 32mm x 6mm and 150mm long with G.I.bolts and nut etc. complete in all respects.

15

60

900

... More
Cost of Chlorinator

1

50000

50000

... More
Earthworki in filling up to Plinth Level

368.91

240

88538.4

... More
Part (B) Electrical Work Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.

44

932

41008

... More
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.

897

800

717600

... More
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.

15

1232

18480

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.

325

376

122200

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.

229

177

40533

... More
Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.

209

462

96558

... More
Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 Amodular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required.

58

573

33234

... More
Supplying and drawing for inverter connection 1x 1.5 sq.mm of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.

1902

35

66570

... More
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.

6

415

2490

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2X 1.5sq.mm+1X1.5sq. mm earth wire

1180

183

215940

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2X 2.5sq.mm+1X2.5sq. mm earth wire

1600

216

345600

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2X 4sq.mm+1X4sq. mm earth wire

2080

263

547040

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2X 6sq.mm+1X6sq. mm earth wire

490

346

169540

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2X 10sq. mm + 1X 6 sq. mm earth wire

595

450

267750

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.4X 16 sq. mm +1 X 6 sq. mm earth wire

50

1076

53800

... More
Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.

42

78

3276

... More
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.

164

267

43788

... More
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep

89

355

31595

... More
Supplying and fixing 4way (4+12),Double door, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)

5

3227

16135

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).

36

533

19188

... More
Supplying and fixing 12 way , Double door, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)

21

1826

38346

... More
Supplying and fixing 8 way , Double door, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)

31

2030

62930

... More
Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required. 32 A TP&N

6

1697

10182

... More
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.

307

201

61707

... More
Supplying and fixing 40A, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.

61

343

20923

... More
Earthing with Copper. earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.

5

10918

54590

... More
Earthing with G.I.r earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.

63

5895

371385

... More
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.

840

192

161280

... More
Supply of ceilling Fan with fan moter ofA.c.Permanent insulation,capacitor rating conforing BEE 5starrating and IS:374/79 and also comply with IS:1709/1984 with latest amendment the rated Voltage 220/240 volt,50Hz,1PH,A.C the fan assemble shuld consists of down rod Blades,shackle canopies etc and with double ball bearing system BEE 5 star rated-1200mm,sweep

164

2153

353092

... More
32 Amp D.P Main Switch

37

1420

52540

... More
Supply and fixing of LED tube light batten suitable for up to 1x20 watt LED Tube Light on surface 100 lm/watt,P.F0.95,THD10% at full load,CRI80,sheet Thickness 0.8mm complete in all respect.

275

612

168300

... More
Supply and fixing LED Bulb 9watt lumen 810 to 945 complete in all respect.

322

199

64078

... More
Supply of fresh air Fan 300mm 1-phase 1400 rpm,230/250 volts,50Hz.

89

2000

178000

... More
Supply and fixing of Lamp base LED mirror light 11W lumen 800 complete in all respect.

22

1746

38412

... More
Supply and laying of aluminium conductor PVC insulatedarmoured served sheathed cables 1100 Volts grade at a depth of750 mm below ground levelover a cushionof 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge,complete in allrespect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc 10 sqmm 4core

370

430

159100

... More
Supply and fixing of Single light wall bracket with opal glasspaint finishing up to 6watt LED complete in all respect.

16

963

15408

... More
Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 70Watt. Confirming to IP 66 and above Protection complete in all respect. 6600-7920 system lumens High Power LED with lenses110lm/W, PF0.95, THD10% at full load CRI 70. potted driver set phase to phase protection at 440V and 300V auto cut and restart feature with 5 year warranty

5

5725

28625

... More
Supply and laying of aluminium conductor PVC insulated armoured served shaethed cables 1100 Volts garde at a depth of 750 mm below ground level over a cushion of 75 mm thick sand all around and protected with burnet bricks on sides and on top. On surface the cable run shall be fixed on M.S, Clamps etc of suitable size or as directed by the Engineer -incharge,complete in all respect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc (i) 16 sq mm 4 core

677

463

313532.24

... More
Supply and laying of aluminium conductor PVC insulated armoured served shaethed cables 1100 Volts garde at a depth of 750 mm below ground level over a cushion of 75 mm thick sand all around and protected with burnet bricks on sides and on top. On surface the cable run shall be fixed on M.S, Clamps etc of suitable size or as directed by the Engineer -incharge,complete in all respect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc (i) 10 sq mm 2 core

1270

325

412750

... More
Supply and laying of aluminium conductor PVC insulated armoured served shaethed cables 1100 Volts garde at a depth of 750 mm below ground level over a cushion of 75 mm thick sand all around and protected with burnet bricks on sides and on top. On surface the cable run shall be fixed on M.S, Clamps etc of suitable size or as directed by the Engineer -incharge,complete in all respect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc (i) 6 sq mm 2 core

1230

371

456809.7

... More
Supply and fixing of 7 meter GI Octagonal Pole of approved make(top dia70mm,Bottom dia 130mm and base plate 12mm thick)having 3mm thikness with singal arm Bracket(1 Mtr.Length)on Rcc foundation including the cost of foundation foundation bolts excavation and,back filling and Required T&P complete in all respect.

30

16500

495000

... More
Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 90Watt. Confirming to IP 66 and above Protection complete in all respect. 8250-9900 system lumens High Power LED with lenses110lm/W, PF0.95, THD10% at full load CRI 70. potted driver set phase to phase protection at 440V and 300V auto cut and restart feature with 5 year warranty

30

9126

273780

... More
Supply and fixing of plain or pin type copper tin plated cable socket(lug) to the cable leads,insulating with tape and making connection etc . Complete in all respect as per direction of the Engineer -Incharge 35 sq mm (i)16SQMM

35

21

735

... More
Supply and fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed,underground cable including rubber ring etc. complete in all respect.The armouring of the cable shall be properly connected with the earth as per direction of Engineer -Incharge. 16 sq mm 4 core

4

87

348

... More
Supply and fixing following capacity of automatic street light cubical control panel painted with anticorrosive alkail and acid proof paint consisting of timer switch TSO 100 series with contractors HRC fuses,isolating switch metering,instrument and instrument box with CTC etc.in case of TPN complete in all respect.

2

17200

34400



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.