Public Works Department Tender

... More
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of etender.up.nic.in - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.

Public Works Department - PWD Tender

Works
Civil And Construction
Road Construction
Eprocure
Opening Date6 Mar 2025
Closing Soon11 Mar 2025
Tender Amount₹ 17,50,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply & fixing of Linear Delineator System (LDS) panels made of Micro Prismatic Retro Reflective sheeting type XI duly laminated on thin aluminium foil to a unique corrugated shape to provide Retro Reflection across wide range of observations and external angles. Eatch LDS panel should be of nominal length of 33 inch and each ridge shall be approximately 0.34 inch high. Each LDS panel is to be firmly fixed on existing concrete/brick work with 16 Nos fastner/ screw . SOR Ch-26 SI No.-9

140

855

119700

... More
Delineator: Supply & Fixing of M S Delineator made of Mild steel with pure polyester powder coating with the minimum thickness of powder coating of not less than 40 micron for protection against corrosion. The surface should be concealed so that there should not be any exposed surface without powder coating. Alternatively, these metal guide poles can be concealed with thermoplastic body. The posts shall have an ellipsoidal or circular design with the height of the pole shall be 800 to 900 mm above the ground with about 200 to 300 mm base which can be anchored onto the ground. Mild steeI Guide Poles shall conform to Type XI sheeting specifications as per IRC:67 upto date and ASTM D4956 which would ensure to obtain clear visibility of the road alignment during night time. The Retro reflective sheeting shall be tested for A certificate of having the sheeting tested for coefficient of retro reflection, daytime colour and luminance, shrinkage, flexibility, liner removal, adhesion, impact resistance, specular gloss and fungus resistance, 3 years outdoor weathering and its having passed these tests shall be obtained from International/Government Laboratory / Institute by the manufacturer of the sheeting and in case the certificate is obtained from international condition, it should also be obtained from Indian condition within 3 years of launching of product by the manufacture in abroad. Alternatively, a certificate conforming to ASTM Specification (D4956-09) on artificial accelerated weathering requirements from a reputed laboratory in India can be accepted provisionally. In such a situation, the Employer / Client, if so desires, could seek for a performance guarantee which would be released after receipt of certificate meeting the requirement of three years outdoor weathering of the sheeting as per IRC 67 upto date & Proof of the same Report shall be uploaded with quoting tender. The rate shall include all materials, labour, T&P, transportation, installation and incidentals all complete as per direction of the Engineer-in-Charge.as per SOR Ch-26 SI No.-2

350

828

289800

... More
Providing and Fixing of Flexible Median Markers as per IRC 79-2019 which shall be made of combination of tough, high impact resistant molded thermoplastic body along with florescent yellow color retro-reflective type XI sheeting with minimum exposed reflective area 285 square mm and with rebound property. The reflective sheeting should confirm to Type XI Florescent Yellow sheeting as per IRC 67 2012 and ASTM D4956-11. The flexible median marker shall have overall height of minimum 180 mm, body thickness of minimum 2mm and shank depth of minimum 30mm. The retro-reflective sheeting shall be on both sides of the Flexible Median Marker and shall be edge protected with no exposed edges which will prevent edge lifting, vandalism, sheeting damage, etc. The edge of sheeting should not come out easily by putting nails, sharp objects etc. The logo of the manufacturer shall be embossed on either side of the body. The product design has to with stand all natural impacts and should not get damaged if any pedestrian stamp on top of it intentionally or unintentionally. The product should bend up to 90 degree on both sides without breakage or damage. The product shall be tested for reboundability & tensile test as per IRC 79-2019 and government lab test report shall be submitted along with tender. If somehow tender pre qualification condition do not ask for government report then the report shall be submitted to engineer-in-charge before finalization of bill. The rate shall include all materials, labour, equipments, fabrication, transportation, erection, installation and incidentals all complete as per direction of the Engineer-in-Charge. .as per SOR Ch-26 SI No.-6

160

312

49920

... More
Tubular Markers (Spring post or Spring Bollard) S/F of plastic Tubular bollards having 450 mm to 700 mm Height, shall be attached to the pavemet to display the minimum 50 mm width of reflective bands to the approaching road users including labour, material, T&P etc. for propar completion of the work. as per SOR Ch-26 SI No.-23 700mm in height

100

1874

187400

... More
6M Span over head Cantilever Structure with 300 dia M S one vertical post Supply, fixing & eraction of built up Cantilever Structure 6 m span comprising of one vertical posts of 6.00 M height made up of 300 mm NB heavy class MS pipe as vertical member welded with 10 mm MS plate at top & 12 mm M S plate at bottom. The horizontal Truss shall comprise of 50 mm dia heavy class M.S. pipe and 40 mm dia heavy M S pipe as bracing & 10 mm MS plate at bottom for fixing to vertical post as per structure design & drawing with one of steel primer and two coats of synthetic enamel plant. The work includes construction of RCC Foundation of size 0.90x0.90x1.50 m of required depth as per site condition for built up structure including Earth work in excavation 100 mm thick Lean Concrete in 1:3:6 cement coarse sand and 40 mm gauge stone ballast and RCC - M25 grade concrete including supply and fixing of 25 mm dia Foundation Bolts 600 mm long as per provision of structure design including cost of reinforcement & shuttering. The lateral vertical clearances and complete. Installation work shall be as per relevant clauses of MORT&H specification section 800 and IRC 67 2012 complete in all respect The Rates shall include cost of design fabrication, supply, transportation, Local shifting Erection of Signage structure using crane, inclusive of all taxes etc. all T&P machine, material and labour required for proper completion of work as per direction of Engineer-in-charge.

1

126302

126302

... More
Providing and erecting direction and place identification retro-reflectorised sign as per IRC-67 made of high intensity grade sheeting The Retro reflective sheeting shall be tested for a certificate of having the sheeting tested for coefficient of retro reflection, daytime colour and luminance, shrinkage, flexibility, liner removal, adhesion, impact resistance, specular gloss and fungus resistance, 3 years outdoor weathering and its having passed these tests shall be obtained from International/Government Laboratory/ Institute by the manufacturer of the sheeting and in case the certificate is obtained from international condition, it should also be obtained from Indian condition within 3 years of launching of product by the manufacture in abroad. Alternatively, a certificate conforming to ASTM Specification (D 4956-09) on artificial accelerated weathering requirements from a reputed laboratory in India can be accepted provisionally. In such a situation, the Employer / Client, if so desires, could seek for a performance guarantee which would be released after receipt of certificate meeting the requirement of three years outdoor weathering of the sheeting as per IRC 67:2012. Legends , letters , numerals and borders etc should be as per MoRTH specification No-801.3.7 . Sheet fixed over aluminium sheeting ,2 mm thick with area not exceeding 0.9 sqm.Supported on a mild steel single angle iron post 75x75x6 mm firmly fixed to the ground by means of property designed foundation with M-15 grade cement concrete 45x45x60 cm.,below ground level as per approved drawing, complete.as per SOR Ch-26 SI No.-19

10

6317

63170



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.