Public Works Department Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Public Works Department - PWD Tender

Works
Civil And Construction
Road Construction
Eprocure
Opening Date13 Jan 2025
Closing Soon22 Jan 2025
Tender Amount₹ 12,40,00,000 
Notes
Download

Costs

Summary

Widening And Strengthening Work Of Chaubepur Bandi Mata Road By Full Depth

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per technical specification clause 401. complete as per Morth Item No 4.01-401B

904.4

-

-

... More
Stabilized Sub-Base (FDR Technology) Providing, laying, spreading and compacting of existing granular material adding cement using truck mounted / self propelled cement spreader shall have variable working width with microprocessor, controlled spray rate through augers and cellular wheels. The aggregate shall be in situ pulverized/stabilize using four wheeled drive recycler having working depth up to 50 cm with variable depth control system. Compacting with vibratory roller, Pneumatic roller and vibratory Pad Foot pad roller (20tonn) to achieve design unconfined compressive strength.

8250

-

-

... More
Construction of sub-grade and earthen shoulders with approved material obtained from borrow pits with all lifts, transporting to site, spreading, grading to required slope and compacted to meet requirement of table No. 300-2 complete as per Morth Item No 3.18-305.

11296.5

-

-

... More
Construction of sub-grade and earthen shoulders with approved material obtained from 5KM carted with all lifts, transporting to site, spreading, grading to required slope and compacted to meet requirement of table No. 300-2 (Carted Earth Upto 5.00km Lead) complete as per Morth Item No 3.18-305

4556.2

-

-

... More
Emulsion Treated Aggregate Base (Wet Mix Macadem + Cement + Emulsion) - As per Morth 2nd Revision 2019. Providing laying and spreading of graded stone aggregate (WMM) after mixing of water at OMCin mechanical mix plant carriage of mixed material by tipper to site laying with 1% OPC and 3.5 % emulsion(SS-2) in uniform single layer on subbase subgrade and compacting with road roller to achive desired density complete as per Morth Item No 4.1.4-406.

4125

-

-

... More
Providing and applying tack coat with bitumen VG-10 using emulsion pressure distributor at the rate of 0.20 kg per sqm on the prepared bituminous surface cleaned with mechanical broom. (Incl cost of bitumen) complete as per Morth Item No 5.02-503(i)

41250

-

-

... More
Providing and laying Bituminous Concrete. with HMP producing an average output of 120 tonnes per hour using crushed aggregates of specified grading premixed with bituminous binder VG-30 @ 5.4 % of mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandom roller to achieve the desired compaction as per MoRT&H Specification clause no 509 complete in all respects.. (Incl cost of bitumen) complete as per Morth Item No 5.05-507B.

1650

-

-

... More
Construction of un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with 43 grade OPC cement @ 400 kg per cum, coarse and fine aggregate conforming to IS 383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design, transported to site, laid with a fixed form or slip form paver, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawing complete as per Morth Item No 6.02-602

2150.5

-

-

... More
Plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by v ibration including curing for 14 days. complete as per Morth Item No 12.04-2100.

365.8

-

-

... More
Plain/Reinforced Cement Concrete in Open Foundation complete as per Drawing and Technical Specifications. RCC Grade M20 complete as per Morth Item No 12.8C-Case II

683.4

-

-

... More
Supplying, fitting and placing TMT steel reinforcement complete in sub-structure as per drawing and Technical Specification (For Drain) complete as per Morth Item No 13.7-1600&2200

42918.2

-

-

... More
Supplying, Fitting and Placing un-coated HYSD bar Reinforcement in Foundation complete as per Drawing and Technical Specifications. (For Box Culvert) complete as per Morth Item No 15.13-1600

29020.1

-

-

... More
Brick Masonry Work in Cement Mortar 1:4 in Foundation complete excluding Pointing and Plastering, as per Drawing and Technical Specifications. complete as per Morth Item No 12.05-1300

122

-

-

... More
Laying Reinforced cement concrete pipe NP4/prestressed concrete pipe for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets complete as per Morth Item No 9.04-2900.

150

-

-

... More
Pointing with Cement Mortar 1:3 on brick work in substructure as per Technical Specifications complete as per Morth Item No 13.02-1300&2200.

310

-

-

... More
Plastering with Cement Mortar 1:4 on brick work in sub-structure as per Technical Specifications complete as per Morth Item No 13.03-1300&2200

22.8

-

-

... More
Lettering with painting on parapet of culvert and KM stone etc including all complete as per Morth Item no 8.3-801. Complete as per direction of Engineer-in-charge.

12

-

-

... More
PCC Grade M 20 using batching plant transit mixure & manual placing complete as per Morth Item No 15.11-1500,1700 & 2100.

483.4

-

-

... More
RCC Grade M25 Using Batching Plant transit mixer & manual placing complete as per Morth Item No 15.11E-Case II

369.6

-

-

... More
Providing weep holes in Brick masonry/Plain/ Reinforced concrete abutment, wing wall/ return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical Specifications complete as per Morth Item No 15.14-2706&2200.

84

-

-

... More
Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces complete as per Morth Item No 8.8-803.

95

-

-

... More
Sand Filling in Foundation Trenches as per Drawing & Technical Specification complete as per Morth Item No 15.03-304

10.7

-

-

... More
Providing and laying boulders apron on river bed for protection against scour with stone boulders weighing not less than 40 kg each complete as per drawing and Technical specification complete as per Morth Item No 16.01-2503.

266.2

-

-

... More
Providing and laying of Filter media with granular materials/stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2. of MoRTH specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and Technical Specification complete as per Morth Item No 15.24-710.1.4 of IRC 78 & 2504.2

43.2

-

-

... More
Thermoplstic Paint - Providing and Laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35. The finished surface to be level, uniform and free from streaks and holes. Rates to be inclusive of all taxes, royalty, VAT etc. all T&P/machine, material and labour required for proper complition of work. In centre line, side line, stop line, Zebra line, etc.

2116

-

-

... More
Providing & fixing, km. stone, hectometre stone etc with complete Informetry sign. (KM Stone) complete as per Morth Item No 8.14-814 (ii).

10

-

-

... More
Providing & fixing, km. stone, hectometre stone etc with complete Informetry sign. (Hectometer Stone) complete as per Morth Item No 8.14-814 (iii).

36

-

-

... More
Providing & fixing, km. stone, hectometre stone etc with complete Informetry sign. (5 Km Stone) complete as per Morth Item No 8.14-814 (i).

1

-

-

... More
Type - A, "W": Metal Beam Crash Barrier - Providing and erecting a "W" metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 1.8 m high, 1.1 m below ground/road level, all steel parts and fitments to be galvanised by hot dip process, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per clause 811.

280

-

-

... More
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC :67 upto date made of high intensity grade sheeting type-IV vide clause 801.3, fixed over aluminium sheeting 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with PCC M-25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing. The Retro reflective sheeting shall be tested for a certificate of having the sheeting tested for coefficient of retro reflection, daytime colour and luminance, shrinkage, flexibility, liner removal, adhesion, impact resistance, specular gloss and fungus resistance, 3 years outdoor weathering and its having passed these tests shall be obtained from International/Government Laboratory/ Institute by the manufacturer of the sheeting and in case the certificate is obtained from international condition, it should also be obtained from Indian condition within 3 years of launching of product by the manufacture in abroad. Alternatively, a certificate conforming to ASTM Specification (D 4956-09) on artificial accelerated weathering requirements from a reputed laboratory in India can be accepted provisionally. In such a situation, the Employer / Client, if so desires, could seek for a performance guarantee which would be released after receipt of certificate meeting the requirement of three years outdoor weathering of the sheeting as per IRC 67 upto date. Legends , letters , numerals and borders etc should be as per MoRTH specification No-801.3.7 . Proof of the same in form of government report shall be uploaded while quoting tender. (40 x 90 Hazard Twoway object)

12

-

-

... More
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC :67 upto date made of high intensity grade sheeting type-IV vide clause 801.3, fixed over aluminium sheeting 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with PCC M-25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing. The Retro reflective sheeting shall be tested for a certificate of having the sheeting tested for coefficient of retro reflection, daytime colour and luminance, shrinkage, flexibility, liner removal, adhesion, impact resistance, specular gloss and fungus resistance, 3 years outdoor weathering and its having passed these tests shall be obtained from International/Government Laboratory/ Institute by the manufacturer of the sheeting and in case the certificate is obtained from international condition, it should also be obtained from Indian condition within 3 years of launching of product by the manufacture in abroad. Alternatively, a certificate conforming to ASTM Specification (D 4956-09) on artificial accelerated weathering requirements from a reputed laboratory in India can be accepted provisionally. In such a situation, the Employer / Client, if so desires, could seek for a performance guarantee which would be released after receipt of certificate meeting the requirement of three years outdoor weathering of the sheeting as per IRC 67 upto date. Legends , letters , numerals and borders etc should be as per MoRTH specification No-801.3.7 . Proof of the same in form of government report shall be uploaded while quoting tender. (Direction plate 80 x 60 rectangular)

8

-

-

... More
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC :67 upto date made of high intensity grade sheeting type-IV vide clause 801.3, fixed over aluminium sheeting 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with PCC M-25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing. The Retro reflective sheeting shall be tested for a certificate of having the sheeting tested for coefficient of retro reflection, daytime colour and luminance, shrinkage, flexibility, liner removal, adhesion, impact resistance, specular gloss and fungus resistance, 3 years outdoor weathering and its having passed these tests shall be obtained from International/Government Laboratory/ Institute by the manufacturer of the sheeting and in case the certificate is obtained from international condition, it should also be obtained from Indian condition within 3 years of launching of product by the manufacture in abroad. Alternatively, a certificate conforming to ASTM Specification (D 4956-09) on artificial accelerated weathering requirements from a reputed laboratory in India can be accepted provisionally. In such a situation, the Employer / Client, if so desires, could seek for a performance guarantee which would be released after receipt of certificate meeting the requirement of three years outdoor weathering of the sheeting as per IRC 67 upto date. Legends , letters , numerals and borders etc should be as per MoRTH specification No-801.3.7 . Proof of the same in form of government report shall be uploaded while quoting tender. (Equilateral Triangular plate 90cm)

3

-

-

... More
Part-B Maintainance Charge including @ Earth Work, repair of painted surface, Earth Work on patri, Culvert, Road Furniture etc as per Direction of E/I for the period of Five Year from the actual completion of work. Total of Work Amount 1 to 36 (Excluding G.S.T.) Maintainance of First Year (@ 0.00% of Total Work Amount of 1 to 35)

1

-

-

... More
Part-B Maintainance Charge including @ Earth Work, repair of painted surface, Earth Work on patri, Culvert, Road Furniture etc as per Direction of E/I for the period of Five Year from the actual completion of work. Total of Work Amount 1 to 36 (Excluding G.S.T.) Maintainance of Second Year (@0.25% of Total Work Amount of 1 to 35)

1

-

-

... More
Part-B Maintainance Charge including @ Earth Work, repair of painted surface, Earth Work on patri, Culvert, Road Furniture etc as per Direction of E/I for the period of Five Year from the actual completion of work. Total of Work Amount 1 to 36 (Excluding G.S.T.) Maintainance of Third Year (@0.50% of Total Work Amount of 1 to 35)

1

-

-

... More
Part-B Maintainance Charge including @ Earth Work, repair of painted surface, Earth Work on patri, Culvert, Road Furniture etc as per Direction of E/I for the period of Five Year from the actual completion of work. Total of Work Amount 1 to 36 (Excluding G.S.T.) Maintainance of Fourth Year (@0.75% of Total Work Amount of 1 to 35)

1

-

-

... More
Part-B Maintainance Charge including @ Earth Work, repair of painted surface, Earth Work on patri, Culvert, Road Furniture etc as per Direction of E/I for the period of Five Year from the actual completion of work. Total of Work Amount 1 to 36 (Excluding G.S.T.) Maintainance of Fifth Year (@1% of Total Work Amount of 1 to 35)

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.