Public Works Department Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Public Works Department - PWD Tender
Civil And Construction
Road Construction
Eprocure
Opening Date12 Jul 2024
Closing Date19 Jul 2024
Tender Amount₹ 8,39,000
Costs
EMD
₹ 84,000Document Cost
₹ 766Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_CEEMP_938167_1Bid Award Id
ViewTender No
1186/nivida suchana (GKP-Zone)-44/24-25 Dt. 27.06.24Tender Authority
Public Works Department ViewPurchaser Address
-Website
http://etender.up.nic.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. D.S.R 1.32 .
12
5597
466.46
Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required. D.S.R 1.57
8
4629
578.69
Supplying and fixing following way, horizontal type Single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator) 8 way (4 + 12), Double door DSR 2.3.2
6
12288
2048.11
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator) 8 way (4 + 12), Double door D.S.R 2.4.1
2
6512
3256.44
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
(A) Single pole DSR 2.10.1
28
5705
203.78
(B) Double pole DSR 2.10.3
6
3133
522.18
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
(A) 40 amps DSR 2.13.1
4
3088
772.12
(B) 63 amps DSR 2.13.2
2
1646
823.06
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2X 1.5 sq.mm+1X1.5sq. mm earth wire D.S.R 1.14.1
180
33384
185.47
2X 2.5sq.mm+1X2.5sq. mm earth wire D.S.R 1.14.2
233
51003
218.9
2X 4sq.mm+1X4sq. mm earth wire D.S.R 1.14.3
100
26586
265.86
2X 6sq.mm+1X6sq. mm earth wire D.S.R 1.14.4
115
40186
349.44
2X 10sq. mm + 1X 6 sq. mm earth wire D.S.R 1.14.5
50
22686
453.72
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.. DSR 5.2
2
10913
5456.58
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. D.S.R 5.15
30
5826
194.22
Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required. D.S.R 1.38
4
315
78.8
Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing D.S.R Civil 10.18
18
1783
99.06
Supplying, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor notless than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. D.S.R 19.1
18
39115
2173.08
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep D.S.R 1.50.1
7
2507
358.2
Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade of following size on wall surface/ Underground as required. complete in all respect. including Lugs and Glands
(A) 50 sq. mm 3-1/2 core 20a.1.12
108
78840
730
Supply and Fixing of 10-15 Watt LED COB Light complete in all respect. CAT AA SOR 23.02
16
18208
1138
Supply and fixing of LED tube light batten suitable for up to 18-22 watt LED Tube Light on surface 100 lm/watt, P.F0.95,THD10% at full load,CRI80, sheet Thickness 0.8mm complete in all respect. CAT AA SOR 23.08
31
25234
814
Supply and Fixing of Bulkhead fitting upto 10 Watt lumen 1000 complete in all respect. CAT AA SOR 23.11
2
2554
1277
Supply and Fixing of Lamp Base LED Mirror Light 11 Watt lumen 800 complete in all respect. CAT AA (RA)
3
5379
1793
Supply and Fixing of LED Street Light fitting having die cast aluminium body and diffuser with driver set suitable for 90 Watt confirming to IP 66 and above protection complete in all respect. 82500-9900 system lumens high power LED with lenses 110 lm/watt, P.F.0.95, THD10% at full Load, CRI70, potted driver set phase to phase protection at 440 V and 300 V, auto cut and restart feature with 5 Year warranty. CAT-AAA SOR 23.16
4
34316
8579
S&F of 100 Amp. four pole change over switch on 50mm x 50mm x 6mm angle iron frame, including the cost of labour, T&P, painting and other material required for proper completion of the work as per direction and satisfaction of Engineer in charge. (MR)
1
9100
9100
Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN ACB(65 KA,4Pole Elect draw out , Micor processer Release IPR2 ) and TPN MCCB's (Four Pole 36 KA with thermal magnatic release) Switches and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type/digital ammeter Voltmeter, Selector switches for ammeter and Voltmeter, istrument fuses, current transormer etc. The Board shall have suitable capacity electrolytic aluminium busbars as per IS8623 insulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/ DMC support with deteachable side covers and shall be suitable for extension on the sides. The switches entry boxes shall be complete with suitable cable end boxes reverse. INCOMING 100 Amp /415Volt ACB-1 No, Outgoing 63 Amp MCCB-2 Nos., 20.1.1(a)
1
107768
107768.64
GST @ 18%
1
127931
127931.3