Public Works Department Tender
... More
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of etender.up.nic.in - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Public Works Department - PWD Tender
Road Construction
Eprocure
Opening Date21 Apr 2025
Closing Soon21 May 2025
Tender Amount₹ 31,50,00,000
Costs
EMD
₹ 47,25,000Document Cost
₹ 11,800Tender Fee
Refer Documents
Summary
Widening And Strengthening Work Of 04 Lane Road From The Main Gate Of Maa Pateshwari Devi Temple To
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_CEDPW_1030984_1Tender No
1893/2Com(B)-Gonda Circle/24-25 Dt. 05.4.25Tender Authority
Public Works Department ViewPurchaser Address
-Website
http://http://uppwd.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
1225.72
-
-
... More
15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:3 (1 cement: 3 fine sand) SOR LKO 2020-21 SI.NO. 13.8.1
1225.72
-
-
... More
Pointing with cement mortar (1:3 ) on brick work in substructure & Super Structure as per Technical Specifications
1240.05
-
-
... More
Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. SOR LKO 2020-21 SI.NO. 2.25(a)
1211.38
-
-
... More
Supply and fixing of M.S. iron railing 1.2 mtr high of approved design having vertical M.S. iron pipe, 14 Gauge of outer dia 41mm molded at rop at the inner dia 200mm connected together with M.S. pipe, 14 gauge of outer dia 25mm at three palces 40mm long and at the clear distance from bottom 125mm filled also with 25mm outer dia pipe continuously total height of railing legs 970mm except outer legs which embedded minimum 125mm in the base with 1:2:4 C.C. of size 230x230x230 mm hole in base . The railing have also two plates of size 230x230 mm squire and circular 14 gauge plane sheet, squire plate weld double on legs and circular plate in between semi circular head as per attaced drawing including cost of all material, labour and T&P etc. required for proper completion of work, and as per direction of E/I. Analysis Rate
69.08
-
-
... More
Direction and place Identification signs up to 0.90 sqm size Board
Providing and erecting direction and place identification retro-reflectorised sign as per IRC-67 made of high intensity grade sheeting The Retro reflective sheeting shall be tested for a certificate of having the sheeting tested for coefficient of retro reflection, daytime colour and luminance, shrinkage, flexibility. liner removal, adhesion, impact resistance, specular gloss and fungus resistance, 3 years outdoor weathering and its having passed these tests shall be obtained from international/Government Laboratory/ Institute by the manufacturer of the sheeting and in case the certificate is obtained from international condition, it should also be obtained from Indian condition within 3 years of launching of product by the manufacture in abroad. Alternatively, a certificate conforming to ASTM Specification (D 4956-09) on artificial accelerated weathering requirements from a reputed laboratory in India can be accepted provisionally. In such a situation, the Employer/Client, if so desires, could seek for a performance guarantee which would be released after receipt of certificate meeting the requirement of three years outdoor weathering of the sheeting as per IRC 67:2012. Legends, letters, numerals and borders etc should be as per MoRTH specification No-801.3.7 Sheet fixed over aluminium sheeting 2 mm thick with area not exceeding 0.9 sqm. Supported on a mild steel single angle iron post 75x75x6 mm firmly fixed to the ground by means of property designed foundation with M-15 grade cement concrete 45x45x60 cm., below ground level as per approved drawing, complete.
2.7
-
-
... More
Supply, fixing & erection of built up Cantilever Structure 2.40 m span comprising of one vertical posts of 7.30 M height made up of 200 mm NB medium class MS pipe and 4.85mm thick as vertical member welded with 10 mm MS plate at top & 10 mm MS plate at bottom fixing to vertical post as per structure design & drawing with one of steel primer and two coats of synthetic enamel plant and The Retro reflective sheeting shall be tested for a certificate of having the sheeting tested for coefficient of retro reflection, daytime colour and luminance, shrinkage, flexibility, liner removal, adhesion, impact resistance, specular gloss and fungus resistance, 3 years outdoor weathering and its having passed these tests shall be obtained from International/Government Laboratory/ Institute by the manufacturer of the sheeting and in case the certificate is obtained from international condition, it should also be obtained from Indian condition within 3 years of launching of product by the manufacture in abroad. Alternatively, a certificate conforming to ASTM Specification (D 4956-09) on artificial accelerated weathering requirements from a reputed laboratory in India can be accepted provisionally. In such a situation, the Employer / Client, if so desires, could seek for a performance guarantee which would be released after receipt of certificate meeting the requirement of three years outdoor weathering of the sheeting as per IRC 67 upto date . Legends , letters , numerals and borders etc should be as per MoRTH specification No-801.3.7 . The work includes construction of RCC Foundation of size 0.60x0.60x1.20 m of required depth as per site condition for built up structure including Earth work in excavation 100 mm thick Lean Concrete in 1:3:6 cement coarse sand and 40 mm gauge stone ballast RCC M25 including supply and fixing of 25 mm dia Foundation Bolts 600 mm long as per provision of structure design including cost of reinforcement & shuttering. The lateral vertical clearances and complete. Installation work shall be as per relevant clauses of MoRT&H specification section 800 and IRC 67 upto date complete in all respect The Rates shall include cost of design fabrication, supply, transportation, Local shifting Erection of Signage structure using crane, inclusive of all T&P machine, material and labour required for proper completion of work as per direction of Engineer-in-charge. (Exclusive cost of G.S.T) as per SOR Ch. 26 Item Sl. No. 29
3
-
-
... More
Supply and, fixing of raised pavement marker with Made of Plastic body of RPM/ Road Stud shall be moulded from ASA (Acrylic Styrene Acrylonitrite) or HIPS (High-imoact Polystyrene) or Acryloniitrite Butadien Styrene (ABS) or Any other suitable material approved by the Engineer. The Marker shall support a load of 13.635 kg tested in accordance with ASTM D4280. The Reflective panels shall consist of number of lenses contatning single or dual prismatic cubes capable of providing total internal reflection of the light entring the lens face Lenses shall be mouled of methyl methecrylate conforming to ASTM D788 of equivalent. The slop or retro-reflecting surface shall preferably be 35+/-5 degree to base and the area of each retro -reflecting surface shall not be less than 13.00 sq cm. the marker height shall not be less than 10 mm and shall not exceed 20 mm & Width shall not exceed 130 mm The base of the be immediately removed. The contractor shall submit a two year warranty for satisfactory field performance including stipulated retro-reflectance of the reflecting panel, to the Engineer In addition, a two year warranty for satisfactory infield performance of the finished road marker shall also be given by the contractor who cames out the work of fixing of reflective road markers. In case the markers arel displaced, damaged get worn out or lose their reflectivity compared to stipulated standards marker shall be flat within 1.3 mm all road studs shall be legibly marked with the name, trade or other means of identification of the manufacture. epoxy installations, excess adhesive around the edge of the marker, excess adhesive on the pavement and adhesive on the exposed surfaces of the markers shall contractor would be required to replace all such markers within 15 days of the intimation fro Engineer, at his own cost. The rate shall include all materials, labour, T&P, transportation, instal. and incidentals all complete as per direction of the Engineer-in-Charge.
663
-
-
... More
Supplying of Solar Raised Pavement Markers made polycarbonate molded body with circular shape , solar powered , LED self illumination in active mode , 360 degree illumination and reflective panels with micro prismatic lens capable of providing total internal reflection of the light entering the lens face in passive mode . The marker shall support a load of 13635 kg tested in accordance to ASTM D 4280. The marker should be resistant to dust and water ingress according to IP 65 standards and should withstand temperatures in the range of 0 C to 70 C. Color of lighting could be provided in red or yellow ( amber ) as per requirement and typical frequency of blinking is 1 Hz . There should be current losses of less than 20 macroamperes at 2.4 V In sleepcharging mode to enhance the life of the marker and a full charge should provide for a minimum autonomy of 50 hours . The height , width and length of the marker shall not be less than 10 mm x 100 mm x 100 mm . Also , the surface diameter of the marker shall not be less than 100 mm respectively . The weight of the marker shall not exceed 0.5 kilograms . Fixing will be by drilling holes on the road for the shanks to go inside , without nails and using epoxy resin based adhesive and complete as directed by the engineer. as per SOR Ch-26 SI No.-16
63
-
-
... More
Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of high intensity grade sheeting vide clause 801.3, fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing (Stop )
2
-
-
... More
30X90 cm (Left/Right) Object Hazard
6
-
-
... More
Painting colur washing with priming and putty
9560
-
-
... More
Providing and laying dence graded 2 bituminous macadam with 100-120 TPH hot mix plant producing an average output of 75 tonnes per hour using crushed aggregates of specified grading premixed with VG-30 @ 4.50% by weight of total mix and filler, transported to site, laid over a previously prepared surface with paver finisher to the required grade, level and alignment and rolled to achieve the desired compaction as per morth specification clause 507 complete in all respects.
2612.99
-
-
... More
Supplying, fitting and placing HYSD bar reinforcement in foundatin complete as per drawing and technical specifications
47.64
-
-
... More
Supply, fixing & eraction of built up Overhead Structure of 12M-15M span comprising of two vertical posts of 6.00 M height made up of 300 mm NB heavy class MS pipe as vertical member welded with 10 mm MS plate at top & 12 mm M S plate at bottom. The horizontal Truss shall comprise of 50 mm dia heavy class M.S. pipe and 40 mm dia heavy MS pipe as bracing & 10 mm MS plate at bottom for fixing to vertical post as per structure design & drawing with one of steel primer and two coats of synthetic enamel plant. The work includes construction of RCC Foundation of size 0.90x0.90x1.50 m of required depth as per site condition for built up structure including Earth work in excavation 100 mm thick Lean Concrete in 1.3.6 (cement coarse sand and 40 mm gauge stone ballast and RCC M-25 cement concrete including supply and fixing of 25 mm dia Foundation Bolts 600 mm long as per provision of structure design including cost of reinforcement & shuttering The lateral vertical clearances and complete. Installation work shall be as per relevant clauses of MORT&H specification section 800 and IRC 67 2012 complete in all respect. The Rates shall include cost of design, fabrication, supply. transportations, Local shifting Erection of Signage structure using crane, inclusive of all taxes etc all T&P machine, material and labour required for proper completion of work as per direction of Engineer-in charge
4
-
-
... More
Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of high intensity grade sheeting vide clause 801.3, fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing
(For Maximum Speed Limit)
6
-
-
... More
Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of high intensity grade sheeting vide clause 801.3, fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing (Junction)
10
-
-
... More
Providing and erecting direction and place identification retro-reflectorised sign as per IRC:67 made of high intensity grade sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick with area not exceeding 0.9 sqm supported on a mild steel single angle iron post 75 x 75 x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 x 45 x 60 cm, 60 cm below ground level as per approved drawing (Facility Information Sings - Resting Place/First Aid Post/Toilet/Filling Station/Hospital/Poilc Station /Picnic Site)
3
-
-
... More
Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of high intensity grade sheeting vide clause 801.3, 2mm thick aluminium sheeting, 3mm/4mm thick Aluminum composite material sheet depending on the size of the sign fixed over back support frame of min 25x25x3mm Angle mounted on a mild steel circular pipe 65 NB ,3.2 mm thicknness firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing.
10
-
-
... More
Providing and laying bituminous concrete with 100-120 TPH batch type hot mix plant producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with VG-30 @ 5.4 percent of mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MORTH specification clause No. 509 complete in all respects.
1356.73
-
-
... More
Planting and Maintaining of flowering plants and shrubs in central verge
4.78
-
-
... More
Road Marking with Hot Applied Thermoplastic Compound with Reflectorising Glass Beads on Bituminous Surface. (Repeated/ Tranvers bar). Providing and laying of hot applied thermoplastic compound 5 mm thick including reflectorising glass beads @ 500 gms per sqm area, thickness of 5 mim is exclusive of surface applied glass beads as per IRC:35-2015 The finished surface to be level, uniform and free from streaks and holes.
64.8
-
-
... More
Same as above item but providing Repeated bars of yellow colour thesuoplastic coupound in 15mm thickness
259.2
-
-
... More
Providing and erecting overhead signs with a corrosion resistant 2mm thick aluminium alloy sheet reflectorised with high intensity retro-reflective sheeting of encapsulated lense type with vertical and lateral clearance given in clause 802.2 and 802.3 and installed as per clause 802.7 over a designed support system of aluminium alloy or galvanised steel trestles and trusses of sections and type as per structural design requirements and approved plans & as per IRC :67
72
-
-
... More
Construction of un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with 43 grade cement @ 400 kg per cum, coarse and fine aggregate conforming to IS 383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design, transported to site, laid with a fixed form or slip form paver, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawing
7608.71
-
-
... More
Providing and laying cement concrete in retaining walls, retum walls, walls (anythickness) including attached pilasters. columns, piers, abutments, pillars, posts, struts, buttresses string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing 1:3:6 (1 cement 3 coarse sand (zone-III) 6 graded stone aggregate 20 mm (nominal size) SOR LKO 2020-21 SI.NO. 4.2.5
93.87
-
-
... More
Construction of embankment with approved material obtained from borrow pits with all lifts and leads upto 1000 m transporting to site, spreading, grading to required slope and compacting to meet requirement of table 300-2. As per Technical Specification Clause 305(3.16) of MORTH
24390.42
-
-
... More
Brick Masonry Work in Cement Mortar 1:3 in Foundation complete excluding Pointing and Plastering, as per Drawing and Technical Specifications.
494.46
-
-
... More
Providing and erecting direction and place identification retro-reflectorised sign as per IRC:67 made of high intensity grade sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick with area not exceeding 0.9 sqm supported on a mild steel single angle iron post 75 x 75 x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 x 45 x 60 cm, 60 cm below ground level as per approved drawing (For School)
4
-
-
... More
Providing and erecting direction and place identification retro-reflectorised sign as per IRC :67 made of High Intensity grade sheeting lause 801.3, fixed over aluminium sheeting, 2 mm thick or Aluminum composite material sheet with overall thickness of 4 mm with area exceeding 0.9 sqm fixed over back support frame of min 40 x 40 x 5 mm MS Angle mounted on two nos. of mild steel circular pipe 65 NB ,3.2 mm thicknness and 4.5 meter total height firmly fixed to the ground by means of properly designed foundation with M 25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing (Place Identification)
8
-
-
... More
Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of table 300-2.Technical Specification Clause 305(3.17) of MORTH
7649.78
-
-
... More
Providing and laying reinforcement concrete for wall and slab M-25 grade including reinforcement complete as per drawing and Technical Specifications. As per MoRTH Spec.2702
60.69
-
-
... More
Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of high intensity grade sheeting vide clause 801.3, fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing (Hazard Marker)
8
-
-
... More
60 mm x 45 mm rectangular with diffinitation plate (20cm X 60cm).
3
-
-
... More
Reinforced Cement Concrete M15 Grade Kilometre stone of standard design as per IRC:8-1980, fixing in position including painting and printing etc
7
-
-
... More
Providing and laying of interlocking concrete Block pavement having thickness 80 mm as per drawings and technical specification Clause 1504. (Exclusive G.S.B.) SOR LKO 2020-21 SI.NO. Mord 1500 (6.7)
350
-
-
... More
Widening & Construction of bridge and culvert
Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 metres
12.93
-
-
... More
Construction Of Median
Filling of earth obtained from barrow pits with all lifts and lead trasporting to side spreading grading to required sloper in median required of Table 300-2
2593.15
-
-
... More
Centering and shuttering including strutting, propping etc. and removal of form work for Retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc. SOR LKO 2020-21 SI.NO. 4.3.2
1017.14
-
-
... More
Construction of cement concrete kerb with top and bottom width 115 and 165 mm respectively, 250 mm high in M 20 grade PCC on M-10 grade foundation 150 mm thick, foundation having 50 mm projection beyond kerb stone, kerb stone laid with kerb laying machine, foundation concrete laid manually, all complete as per clause 408
9560
-
-
... More
60 cm equilateral triangle with definition plate (20cm X 60cm)
6
-
-
... More
Plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days.
99.12
-
-
... More
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC :67 upto date made of high intensity grade sheeting type-IV vide clause 801.3, fixed over aluminium sheeting 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with PCC M-25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing. The Retro reflective sheeting shall be tested for a certificate of having the sheeting tested for coefficient of retro reflection, daytime colour and luminance, shrinkage, flexibility, liner removal, adhesion, impact resistance, specular gloss and fungus resistance, 3 years outdoor weathering and its having passed these tests shall be obtained from International/Government Laboratory/ Institute by the manufacturer of the sheeting and in case the certificate is obtained from international condition, it should also be obtained from Indian condition within 3 years of launching of product by the manufacture in abroad. Alternatively, a certificate conforming to ASTM Specification (D 4956-09) on artificial accelerated weathering requirements from a reputed laboratory in India can be accepted provisionally. In such a situation, the Employer / Client, if so desires, could seek for a performance guarantee which would be released after receipt of certificate meeting the requirement of three years outdoor weathering of the sheeting as per IRC 67 upto date. Legends , letters , numerals and borders etc should be as per MoRTH specification No-801.3.7 . Proof of the same in form of government report shall be uploaded while quoting tender. 60 cm circular with definition plate (20cm X 60cm)
15
-
-
... More
Providing and laying of Filter media with granular materials/stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2. of MoRTH specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and Technical Specification.
29.97
-
-
... More
Providing and laying Cement concrete wearing coat M-30 grade including reinforcement complete as per drawing and Technical Specifications
6.9
-
-
... More
Providing weep holes in Brick masonry/Plain/ Reinforced concrete abutment, wing wall/ return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical Specifications
108
-
-
... More
Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.
473.61
-
-
... More
Flexible Median Marker (FMM) should be used for improving median visibility during dark hours. , Use of Median Marker provides safety against collision happening with medians during night time , or severe weather. Flexible Median Markers shall be provided with fluorescent yellow colour retro-reflective sheeting Type XI as per IRC:67 upto date. Flexible Median Marker shall be of tough, high impact resistant, injection-molded, thermoplastic body with property of flexibility to provide high durability 'and U shape structure having rebound / bounce back property. the sheeting shall be of Type XI conforming to IRC:67 upto date and it should be on both .the faces whereby providing maximum reflectivity at longer distances with adequate durability. The logo of the manufacturer shall be embossed on either side of the body during the injection molding process. FMM shall be fixed by a combination of epoxy adhesive and grouting/ drilling on concrete medians or properly constructed solid medians. Height: The marker height shall be a minimum of 180 mm. width 120 mm & Body Thickness: 6.5 mm. the shanks shall not be less than 20 mm and depth shall not be less than 30 rnm Reflective Area: Shall not be less than 90 cm square . Proof of the same Report shall be uploaded which quoting tender. The body of FMM shall bounce back to its original position of after 750 number of hits using pendulum of 1.8 kg conforming 40 ASTM D256 adhesion between the body and outer casing body of FMM shall with stand 50 kg f Tensile loads conforming to ASTM D638 method. The rate shall include all materials, labour, T&P, transportation, installation and incidentals all complete as per direction of the Engineer-in-Charge. As per SOR ch-26 SI no.-6
62
-
-
... More
Providing and applying tack coat with emulsion using emulsion pressure distributor at the rate of 0.20 kg per sqm on the prepared bituminous/granular surface cleaned with mechanical broom as per Technical Specification Clause 503.
(Including cost of Emulsion)
46222.5
-
-
... More
Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying with 1% OPC Cement + 3.50% Emulsion in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density.
2795.95
-
-
... More
Supply & Laying of 1000 mm dia NP3 hume pipe including fixing of collar with 1:2 cement mortar as per MORD/ MORTH specification
15
-
-
... More
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the All kinds of soil. SOR LKO 2020-21 SI.NO. 2.8.1
853.71
-
-
... More
Reinforced Cement Concrete M15 Grade Hectometre stone of standard design as per IRC:8-1980, fixing in position including painting and printing etc
21
-
-
... More
Aluminum-backed flexible prismatic sheeting shall be made of yellow colored flexible prismatic sheeting with non-metallic prismatic lens formed in a transparent, synthetic resin as retro reflective elements. This flexible prismatic sheeting shall have black and yellow stripes with aluminum backed flexible prismatic Type VI sheeting conforming to ASTM: D4956 . specifications and standards of coefficient of retro reflectivity, flexibility and impact resistance applicable for reboundable devices. This flexible prismatic sheeting shall have screen printed arrow/slant line pattern in black colour in a continuous roll format. Width of object marker shall be 300 mm. The rate shall include all materials, labour, T&P, transportation, installation and incidentals all complete as per direction of the Engineer-in-Charge. as per SOR Ch-26 SI No.-24
20.72
-
-
... More
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
1225.72
-
-
... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
7368.8
-
-
... More
Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 tonnes vibratory roller, finishing and curing.
5156.63
-
-
... More
Tubular Markers (Spring post or Spring Bollard)
S/F of plastic Tubular bollards having 450 mm to 700 mm Height, shall be attached to the pavemet to display the minimum 50 mm width of reflective bands to the approaching road users including labour, material, T&P etc. for propar completion of the work. 700 mm Height
80
-
-
... More
Excavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, and transporting to the embankment location within all lifts and lead upto 1000 m. As per Technical Specification Clause 301 of MORTH
7649.78
-
-
... More
Construction of granular sub-base by providing close graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401
16347.76
-
-
... More
Cast-in-Situ Cement Concrete M 20 Kerb
Construction of cement concrete kerb with top and bottom width 115 and 165 mm respectively. 250 mm high in M 20 grade PCC on M-10 grade foundation 150 mm thick, foundation having 50 mm projection beyond kerb stone, kerb stone laid with kerb laying machine, foundation concrete laid manually, all complete as per Clause 408. SOR LKO 2020-21 SI.NO. MoRTH - 804 (8.1)
175
-
-
... More
P/L of hot applied thermo plastic compound 2.5 mm thick including reflecto rising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass breads as per IRC 35.The finished surface to be level uniform & free from streaks and hole. in edges and center line.
3017.2
-
-
... More
Bollard (Single Side) Supply & fixing of Bollard made(Single Side) out of 2mm thick aluminium sheet face to be covered with high intensity prismatic grade type IV sheeting, Legends, letters, numerals and borders etc should be as per MoRTH specification No-801.3.7 Welded poly shaped to make it monolithic pillar size 1200 mm high Bollard is having a frame 900x600 mm and 600 mm dia for fixation made out of 35 x 35 x 5 mm angie iron and from side is fully cover (size of foundation 0.45x0.45x0,60m).
36
-
-
... More
Construction of sub-grade and earthen shoulders with approved material obtained from borrow pits with all lifts & leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of table No. 300-2
1804.15
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%