Pradeshik Cooperative Dairy Federation Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Pradeshik Cooperative Dairy Federation Tender
Civil And Construction
Building Construction
Eprocure
Opening Date5 Nov 2024
Closing Date21 Nov 2024
Tender Amount₹ 15,00,000
Costs
EMD
₹ 50,000Document Cost
₹ 1,770Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_UPCDF_971012_1Bid Award Id
ViewTender No
C-1011/PAG/NIVIDA/24-25Tender Authority
Pradeshik Cooperative Dairy Federation ViewPurchaser Address
-Website
http://etender.up.nic.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering- All work up to plinth level: 1:4:8 (1 Cement: 4 coarse sand: 8 graded stone aggregate 40 mm nominal size).
13
-
-
Brick Work Brick work with F.P.S bricks of class designation 75 in foundation and plinth in Cement mortar 1:6 (1 cement: 6 coarse sand)
10
-
-
Brick Work Brick work with F.P.S bricks of class designation 75 in superstructure above plinth level up to floor V level in all shapes and sizes in Cement mortar 1:6 (1 cement: 6 coarse sand)
20
-
-
Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement- All work up to plinth level 1:1.5:3 (1 cement: 1.5 coarse sand: 3 graded stone aggregate 20 mm nominal size)
5
-
-
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15 degree landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement with 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size).
2
-
-
Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up to floor five level excluding cost of centring, shuttering, finishing and reinforcement 1:1.5:3 (1 cement: 1.5 coarse sand: 3 graded stone aggregate 20 mm nominal size)
2
-
-
Centring and shuttering including strutting, ropping etc. and removal of form for foundations, footings, bases for columns
20
-
-
Lintels, beams, plinth beams, girders, bressumers and cantilevers
25
-
-
Columns, Pillars, Piers, Abutments, Posts and Struts. Column
50
-
-
Supplying and filling in plinth with Jamuna sand under floors including, watering, ramming consolidating and dressing complete.
72
-
-
Reinforcement for R.C.C Work Including Straightening, cutting bending, placing in position and binding all complete. Thermo- Mechanically Treated bars.
750
-
-
12 mm cement plaster of mix 1:6 (1 cement: 6 fine sand)
136
-
-
15 mm cement plaster on rough side of single or half brick wall of mix 1:6 fine sand).
91
-
-
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer – in – charge) 0.50 mm (+ 0.05%) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length up to 12 metre or as desired by Engineerin - charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x55mm) with EPDM seal, complete up to any pitch in horizontal/ vertical or curved surfaces, excluding the cost of Purlins, rafters and trusses and including cutting to size and shape wherever required.
160
-
-
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+ 0.05%) total coated thickness, zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top Coat 15-18 microns using self drilling / self tapping screws complete Gutter(600 mm Over all Girth)
13
-
-
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+ 0.05%) total coated thickness, zinc coating
120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top Coat 15-18 microns using self drilling / self tapping screws complete . Ridges plain (500- 600 mm)
13
-
-
Supplying and fixing rolling shutters of approved make, made of required size M.S laths, interlocked together through their entire length and jointed together at the end by locks, mounted on specially designed Pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the coat of providing and fixing necessary 27.5 cm long wire spring manufactured from high tensile steel wire of adequate strength conforming to IS: 4454- part 1 and M.S top cover of required thickness of rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover
9
-
-
Providing and fixing ball bearing for rolling shutters.
2
-
-
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade Tow or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture.
150
-
-
Providing and laying in position cement concreate of specified grade excluding the coat of centering and shuttering – All work up to plinth level :1:2:4(1 cement : 2 coarse sand (zone-lll) : 4 graded stone aggregate 20 mm nominal size)
8
-
-
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. Complete Hot finished welded type tubes.
2500
-
-
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A, including jointing with seal ring conforming to IS: 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 75 mm diameter
12
-
-
Providing and fixing on wall face unplasticised – PVC moulded fitting/accessories for unplasticised Rigid PVC rain water pipes conforming to IS: 13592 Type A, including jointing with seal ring conforming to IS: 5382, leaving 10 mm gap for thermal expansion. Bend 87.5 .75 mm bend
4
-
-
Cement concreate flooring 1:2:4(1 cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat neat cement, including cement slurry, but excluding the coat of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate.
78
-
-
Providing and fixing glass strips in joints of terrazzo/ cement concrete floors. 40 mm wide and 4 mm thick WGPCMOD point wiring in pvc conduit with modular type switch wiring for light point/fan point with 1.5 sqmm fr pcv insulated coper conducter single core cable in surface/ recessed pvc conduit with modular switch modular plate suitable gi box and earthing the point with 1.5 sqmm fr pvc insulated coper conducter single core cable etc. as required
234
-
-
Groupe A
8
-
-
WGPVCPP2 power plug wiring in pvc conduit (2*4 sq. mm wiring for light / power plug with 2*4 sq. mm for pvc insulated copper conducter single core cable in surface/recessed pvc conduit along with 1 on 4 sq mm fr pvc insulated copper conducter single core cable for loop bearthing as required WGPVCSB Circuit/ sub man wiring in pvc conduit wiring for circuit/sub man wiring along with earth wire with the following sizes of pvc insulated copper conduter single core cable in surface/recessed pvc conduit as required.
10
-
-
2*4sqmm + 1*4sqmm earth wire. MS s/f metal boxes of following size (nominal sizes) on surface or in recesse with suitable size of phenolic laminated sheet cover in front including painting etc. required.
10
-
-
100MM*100MM*60MM DEEP
2
-
-
Supplying an fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (Rccb), having a sensitivity current up to 300 mamp in the existing MCB DB Completed with testing and commissioning etc. as required. 25 amps
1
-
-
Finishing walls with Acrylic smooth exterior paint of required shade: New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10sqm)
136
-
-
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade: New work (two or more coats) over and including water tenable priming coat with cement primer
91
-
-
Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement: 2 coarse sand(zone-III): 4 graded stone Aggregate 12.5mm nominal size)
9
-
-