If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Pashchimanchal Vidyut Vitran Nigam Limited - PVVNL Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date28 Mar 2023
Closing Date5 Apr 2023
Tender AmountRefer Documents 
Notes
Download

Costs

Summary

Work Of Increasing Capacity Of Transformers New Line Errection And Other Works Under The Area Of Edd 1 Moradabad

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
11/0.4 63 KVA Transformers.

2

-

-

... More
11/0.4 100 KVA Transformers.

1

-

-

... More
11/0.4 250 KVA Transformers.

27

-

-

... More
11/0.4 400 KVA Transformers.

24

-

-

... More
LT A.B.C. Cable of size 3X120+1X95+1X16, 3X95+1X70+1X16 and other.

164675

-

-

... More
11 KV XLPE cable of size 3x70 sq.mm./ 3x120 sq.mm./ 3x180 sq.mm. etc.

2700

-

-

... More
Line material such as Cross-Arms, Pin Insulators, Guarding Angles, Guarding Wire, Disc Insulators and Cable Jointing Kits etc.

4586

-

-

... More
11 KV A.B.C.

2000

-

-

... More
33 KV Cable of size 3x300

780

-

-

... More
11 KV Cable of size 3x120

680

-

-

... More
Dismantling of the line by :-

-

-

-

... More
Removing of ACSR Weasel/Dog conductor from all phases on line, making bundle and stacking at a safe place.

2500

-

-

... More
For 33 KV Line, Double Pole structure with 13/11/9/8.5 Mtr. long ST/PCC Poles :- Excavation of foundation pit in size of 75x45 cm. having depth of 1/6th of the full length of the support (pole). Erection of support (pole) complete work by fixing of D.P. Clamps and all other accessories. The work includes fabrication work and fixing of cross bracing sets, cutting holes complete work as per RESPO Norms.

2

-

-

... More
For 33 KV Line, Single support 13/11/9/8.5 Mtr. long ST/PCC Poles :- Excavation of foundation pit in size of 75x45 cm. having depth of 1/6th of the full length of the support (pole), providing and laying of stone pad (300x300x75mm.) in the bottom of the pit. Erection of support (pole) complete with fixing of 11 KV V-Type cross-arms and all other accessories by providing stone pad, cross arms, holding clamps, f-bracket and nuts & bolts etc. as per RESPO Norms.

22

-

-

... More
For 11 KV Line, Double Pole structure with 13/11/9/8.5 Mtr. long ST/PCC Poles :- Excavation of foundation pit in size of 75x45 cm. having depth of 1/6th of the full length of the support (pole). Erection of support (pole) complete work by fixing of D.P. Clamps and all other accessories. The work includes fabrication work and fixing of cross bracing sets, cutting holes complete work as per RESPO Norms.

18

-

-

... More
For 11 KV Line, Single support 13/11/9/8.5 Mtr. long ST/PCC Poles :- Excavation of foundation pit in size of 75x45 cm. having depth of 1/6th of the full length of the support (pole), providing and laying of stone pad (300x300x75mm.) in the bottom of the pit. Erection of support (pole) complete with fixing of 11 KV V-Type cross-arms and all other accessories by providing stone pad, cross arms, holding clamps, f-bracket and nuts & bolts etc. as per RESPO Norms.

1113

-

-

... More
Grouting of Poles Single line support :- Grouting of support in CC 1:4:6 (cement, sand and 40 mm. brick ballast) Grouting will be done in the block of size 45cm x 45cm x 1/6th of full length of the support upto ground level as per RESPO Norms.

1157

-

-

... More
Grouting of stay rods (20x1800mm.) including all works of excavation, cement concrete in size of (0.60x0.60x0.30)M in the ratio of 1:4:6 (cement, sand and 40 mm. brick ballast) including back filling of soil and proper ramming etc.

463

-

-

... More
Fixing, tightening and nozelling of stay wire with stay rod and stay insulators with the pole of required tension by providing stay clamps, nuts, bolts etc.

1532

-

-

... More
Earthing of support with MS Earth Rod of (20x2500)mm. long including excavation of pit and driving MS Rod 3.0M apart from support and 0.5M below the ground level and connecting below the earth electrodes with the help of G.I. Wire No.6 SWG tightening with nuts and bolts.

1165

-

-

... More
Laying, sagging, stringing and binding of ACSR Weasel/ Dog Conductor with all other accessories on pole as per RESPO Norms.

67763

-

-

... More
Laying, sagging, stringing and binding of LT ABC Conductor with all other accessories on pole as per RESPO Norms.

164675

-

-

... More
Laying of 11 KV XLPE AB Cable and making connections as per RESPO Norms.

2000

-

-

... More
Filling and fixing of 11 KV outdoor/indoor type cable jointing kits as per RESPO Norms.

36

-

-

... More
Construction of 11 KV Underground Line :-

-

-

-

... More
Digging of cable trench in size of 0.45Mtr.x1.05 Mtr.

3180

-

-

... More
Laying of 11 KV 3x70/120/185 sq.mm. cable in the trench.

3180

-

-

... More
Providing 150 mm. sand cushion beneath and 150 mm. above the cable. The cable shall be duly protected by 1st Class Bricks, two on either side and third on top of the cable, laid in the series one after the other.

3160

-

-

... More
Refilling and ramming of the left out soil, closing and trench and levelling. Spare cable shall be left in the loop shape at both ends, including providing of all required material and T&P.

3160

-

-

... More
Providing and fixing of Danger Board with clamp, nut and bolts.

75

-

-

... More
Providing and wrapping of barbed wire on 11 KV PCC Poles at a height of 2.75 Mtr. from the ground level as per RESPO Norms.

1495

-

-

... More
Guarding of 11 KV Line with G.I. wire as per RESPO Norms.

9

-

-

... More
Construction of plinth suitable for 250 KVA Transformer in size of 2.0X2.0X1.5 Mtr. Including cost of material as per RESPO Norms.

27

-

-

... More
Installation of 250 KVA Transformer on plinth including HT/LT connections as per RESPO Norms.

27

-

-

... More
Construction of plinth suitable for 400 KVA Transformer in size of 2.0X2.0X1.5 Mtr. Including cost of material as per RESPO Norms.

24

-

-

... More
Installation of 400 KVA Transformer on plinth including HT/LT connections as per RESPO Norms.

24

-

-

... More
Providing, erection and fixing of wire mesh fencing of 2.00X2.00X1.50 Mtr. Size of 24 gauge with 4 Nos. 35X35X4 mm. angle for support, including grouting at suitable height from the groung in such a way that 11/0.4 KV, 250 KVA & 400 KVA sub station is covered in safe manner. The fencing will be painted with one coat of Red oxide as primer and two coats with green colour.

51

-

-

... More
Providing G.I. Pipe 6” dia for inserting 11 KV XLPE cable for safety of cable on Single/Double Pole by providing and fixing of MS Clamp, Nuts and Bolts.

160

-

-

... More
Laying of 33 KV cable and making connections as per RESPO Norms.

780

-

-

... More
Carriage of following from work site to Store Centre Majhola including loading and unloading at both ends :-

-

-

-

... More
13 Mtr./11 Mtr./9 Mtr. Long ST Poles.

766

-

-

... More
ACSR Weasel/Dog Conductor/M.S. Scrap./L.T. cable scrap.

16

-

-

... More
11/0.4 25 KVA Transformers.

2

-

-

... More
11/0.4 63 KVA Transformers.

1

-

-

... More
11/0.4 100 KVA Transformers.

26

-

-

... More
11/0.4 250 KVA Transformers.

15

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.