Pashchimanchal Vidyut Vitran Nigam Limited Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Pashchimanchal Vidyut Vitran Nigam Limited - PVVNL Tender
Electrical Generators And Transformers
Electrical and Electronics
Eprocure
Opening Date30 Nov 2024
Closing Date11 Dec 2024
Tender Amount₹ 66,20,000
Costs
EMD
₹ 66,500Document Cost
₹ 3,540Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_PVVNL_978884_1Bid Award Id
ViewTender No
E-Tender No. 40/EWC-MRT/2024-25Tender Authority
Pashchimanchal Vidyut Vitran Nigam Limited ViewPurchaser Address
-Website
http://http://pvvnl.org/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
(iv) 100 KVA
280
-
-
... More
(v) 160 KVA
50
-
-
... More
(vi) 250 KVA
85
-
-
... More
(vii) 400 KVA
150
-
-
... More
(viii) 630/1000 KVA
10
-
-
... More
Cutting of sealed T/fs top cover/ opening of nut and bolt of damaged t/f cover plate, de- tanking of core coil assembly dismantling of HV&LV Coils and other accessories, draining of T/f oil in sump well and weighing of scraps and shifting of all scrap to the store of JE in charge. (i) 10/16 KVA
800
-
-
... More
(ii) 25 KVA
760
-
-
... More
(iii) 63 KVA
280
-
-
... More
(iv) 100 KVA
280
-
-
... More
(v) 160 KVA
50
-
-
... More
(vi) 250 KVA
85
-
-
... More
(vii) 400 KVA
150
-
-
... More
(viii) 630/1000 KVA
10
-
-
... More
Dismantling of core stamping and its cleaning of dust and dirt. (i) 10/16 KVA
800
-
-
... More
(ii) 25 KVA
760
-
-
... More
(iii) 63 KVA
280
-
-
... More
(iv) 100 KVA
280
-
-
... More
(v) 160 KVA
50
-
-
... More
(vi) 250 KVA
85
-
-
... More
(vii) 400 KVA
150
-
-
... More
(viii) 630/1000 KVA
10
-
-
... More
Assembly of core coils and fitting of other accessories requiring replacement such as press board support spacers and tapping etc. and also cutting of insulation required for coil assembly. (i) 10/16 KVA
800
-
-
... More
(ii) 25 KVA
760
-
-
... More
(iii) 63 KVA
280
-
-
... More
(iv) 100 KVA
280
-
-
... More
(v) 160 KVA
50
-
-
... More
(vi) 250 KVA
85
-
-
... More
(vii) 400 KVA
150
-
-
... More
(viii) 630/1000 KVA
10
-
-
... More
Dragging of T/f Tank to washing Zone its cleaning by jet pump and washing by caustic soda shifting to open space for drying Providing primer of red oxide on the inner and outer side of tank and painting inner side of T/fs including core channel and tie rod / core rods with heat proof zinc chromate paint and out side with two coats of synthetic grey enamel paint. The paint should be of Asian/Nerolec/Burger/ Dulux/British make only. Writing of PUC/ Unique No. of transformer readable paint color with the help of stencils design. (i) 10/16 KVA
800
-
-
... More
(ii) 25 KVA
760
-
-
... More
(iii) 63 KVA
280
-
-
... More
(iv) 100 KVA
280
-
-
... More
(v) 160 KVA
50
-
-
... More
(vi) 250 KVA
85
-
-
... More
(vii) 400 KVA
150
-
-
... More
(viii) 630/1000 KVA
10
-
-
... More
Making of new HV coil from new wire / strip as per design of respective T/F (Complete Job) (i) 10/16 KVA
800
-
-
... More
(ii) 25 KVA
760
-
-
... More
(iii) 63 KVA
280
-
-
... More
(iv) 100 KVA
280
-
-
... More
(v) 160 KVA
50
-
-
... More
(vi) 250 KVA
85
-
-
... More
(vii) 400 KVA
150
-
-
... More
(viii) 630/1000 KVA
10
-
-
... More
Making of new LV coil from new wire / strip as per design of respective T/F (Complete Job) (i) 10/16 KVA
800
-
-
... More
(ii) 25 KVA
760
-
-
... More
(iii) 63 KVA
280
-
-
... More
(iv) 100 KVA
280
-
-
... More
(v) 160 KVA
50
-
-
... More
(vi) 250 KVA
85
-
-
... More
(vii) 400 KVA
150
-
-
... More
(viii) 630/1000 KVA
10
-
-
... More
Complete the core and coil assembly(CCA) by fitting HV & LV coils required insulating material and shifting it to oven for de-moisture (i) 10/16 KVA
800
-
-
... More
(ii) 25 KVA
760
-
-
... More
(iii) 63 KVA
280
-
-
... More
(iv) 100 KVA
280
-
-
... More
(v) 160 KVA
50
-
-
... More
(vi) 250 KVA
85
-
-
... More
(vii) 400 KVA
150
-
-
... More
(viii) 630/1000 KVA
10
-
-
... More
Tanking of the complete core and coil assembly (CCA) in to the painted tank safely, filling of reclaimed / centrifuged/ fresh oil fitting of all accessories. (i) 10/16 KVA
800
-
-
... More
(ii) 25 KVA
760
-
-
... More
(iii) 63 KVA
280
-
-
... More
(iv) 100 KVA
280
-
-
... More
(v) 160 KVA
50
-
-
... More
(vi) 250 KVA
85
-
-
... More
(vii) 400 KVA
150
-
-
... More
(viii) 630/1000 KVA
10
-
-
... More
Welding/ Tightening of nut and bolts of top cover of repaired T/f by electric welding filling Gap etc. properly including denting of tank if necessary and welding of MS plate 100x50x3 mm thick on the out side of the T/Fs contain unique no., capacity, name of the workshop etc. at proper place . (i) 10/16 KVA
800
-
-
... More
(ii) 25 KVA
760
-
-
... More
(iii) 63 KVA
280
-
-
... More
(iv) 100 KVA
280
-
-
... More
(v) 160 KVA
50
-
-
... More
(vi) 250 KVA
85
-
-
... More
(vii) 400 KVA
150
-
-
... More
(viii) 630/1000 KVA
10
-
-
... More
Dragging the Repaired T/f to the testing zone for final testing with necessary record and after testing it should be re dragged / stacked at despatch area. (i) 10/16 KVA
800
-
-
... More
(ii) 25 KVA
760
-
-
... More
(iii) 63 KVA
280
-
-
... More
(iv) 100 KVA
280
-
-
... More
(v) 160 KVA
50
-
-
... More
(vi) 250 KVA
85
-
-
... More
(vii) 400 KVA
150
-
-
... More
(viii) 630/1000 KVA
10
-
-
... More
General Cleaning of T&P / Machinery and stacking of material at suitable place
300
-
-
... More
General clearness of store testing room, workshop floor, oven area, generator room, in cutting area, tanking area, assembly area, painting area by wiping, booming and wooden dust properly to keep floor clean by engaging proper man power for cleaning works. As required for cleaning works
300
-
-
Evaluation Notes How It Works ?