Pashchimanchal Vidyut Vitran Nigam Limited Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Pashchimanchal Vidyut Vitran Nigam Limited - PVVNL Tender

Works
Software and IT Solutions
Eprocure
Opening Date16 Feb 2019
Closing Date25 Feb 2019
Tender Amount₹ 5,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
3-Line material such as 11 KV cross arm/11KV pin insulator/conductor/GI wire/MS angle & MS channel/stay wire/stay rod, disc fitting etc.

45

-

-

... More
Cartage of the following material from J.E. store to site of work including loading & unloading at both ends.maximum distance up to 10 km

-

-

-

... More
1-PCC Pole 8.5 mtr. Long.

41

-

-

... More
2-Round Pole/PCC Pole 9.5 mtr. Long.

11

-

-

... More
3-Line material such as 11 KV cross arm/11KV pin insulator/conductor/GI wire/MS angle & MS channel/stay wire/stay rod, disc fitting etc.

45

-

-

... More
Safe cartage of Transformer from central store Meerut to J.E. store of work including loading & unloading at both ends (maximum distance up to 50 km.)

-

-

-

... More
1-250 KVA

1

-

-

... More
2-63 KVA to 100 KVA

4

-

-

... More
3-10 KVA to 25 KVA

5

-

-

... More
Safe cartage of Transformer from J.E. store to site of work including loading & unloading at both ends (maximum distance up to 15 km.)

-

-

-

... More
1-250 KVA

1

-

-

... More
2-63 KVA to 100 KVA

4

-

-

... More
3-10 KVA to 25 KVA

5

-

-

... More
Erection of Round Pole/P.C.C. Pole 8.5 Mtr. Long including fixing all accessories and fabrication as required after digging a pit of size 1.20X0.75X1.75 Mtrs.

-

-

-

... More
1-PCC Pole

41

-

-

... More
2-Round Pole/ST Pole 11 mtr. Long.

11

-

-

... More
Erection of D/P on PCC/Round Poles after digging of pits of size 1.20X0.75X1.75 Mtrs including fabrication of Structure as per RESPO norms.

9

-

-

... More
Earthing of PCC support with MS Earth rod of 2.5 Mtr. Long including excavation of pit & driving of MS rod up to proper depth & connection the earth electrode with the help of GI wire.

20

-

-

... More
Laying Lifting stringing and sagging of conductor complete in all respects as per RESPO norms.

-

-

-

... More
1-Rabbit Conductor.

1200

-

-

... More
2-Weasel Conductor.

15000

-

-

... More
Erection fixing & grouting of stay rod size 16X1800mm after digging the pit of size 0.60X0.30X0.30 meter in ratio 1:4:8 including fixing of stay wire clamp and nuzzling at the both ends.

20

-

-

... More
Straightening of tilled PCC Pole of 11 KV/LT Lines after opening the bindings from insulators and digging the pit for require depth and refilling the same pit after completion of work including rebinding the conductor with insulators & sagging the conductor.

10

-

-

... More
Mounting of 11/0.4 KV T/F on plinth & making connection of PVC Cable & Lead of HT/LT line.

-

-

-

... More
1-63 KVA to 100 KVA

4

-

-

... More
2-10 KVA to 25 KVA

5

-

-

... More
Providing & fixing of following clamps for PCC Pole/STP, made of MS flat of size 50X6mm complete in all respect.

-

-

-

... More
1-LT Pin Clamps with nut & bolt.

60

-

-

... More
2-Shackle Insulator with nut & bolt.

120

-

-

... More
3-Double Pole Clamps with nut & bolt.

18

-

-

... More
Providing & fixing of stay clamp for PCC Pole/STP made of MS flat of size 50X6 mm complete in all respect.

20

-

-

... More
Providing & fixing of Stay insulator in stay wire as per site requirement.

20

-

-

... More
Fabrication of cross arm from given MS channel for making T/Section of HT Line.

10

-

-

... More
Dismantling of PCC pole of existing line after opening all fittings and digging the pit of required size.

10

-

-

... More
Providing & Fixing of F-Clamp for PCC Pole/STP made of MS flat of size 50X6mm with nut & bolt.

25

-

-

... More
Providing & fixing of cross arm holding clamp for PCC Pole/STP made MS flat of size 50X6mm with nut & bolt.

25

-

-

... More
Dismantling of Damaged/Rusted STP/Rail pole of existing line after opening all fittings and digging the pit of required size.

10

-

-

... More
Providing D-Type loop on each face & neutral.

80

-

-

... More
Providing & fixing of bamboo sticks of required size on LT Line as per instructions of JE concerned.

80

-

-

... More
Making section T-off for 11 KV/LT Line.

3

-

-

... More
Refixing of old stay after digging of pole of regard size & then grouting of stay on site required.

7

-

-

... More
Cutting & Chopping of tree branches.

10

-

-

... More
Jumpering of 11 KV/LT Line at different places/T points.

15

-

-

... More
Disconnecting the Cable of existing consumers from LT Line and reconnection the cable of existing consumers after completion the work of replacement of damaged conductor etc.

80

-

-

... More
Guarding of 11 KV Line as per norms.

10

-

-

... More
Removal of damaged/burnt conductor/GI wire after opening the bindings & making the role etc.

-

-

-

... More
1-Rabbit Conductor

1200

-

-

... More
2-Weasel Conductor.

12000

-

-

... More
Resagging of Loose 11 KV Line/LT Line after opening the binding than stringing the conductor & rebinding the same properly.

-

-

-

... More
1-Rabbit Conductor.

15

-

-

... More
2-Weasel Conductor.

30

-

-

... More
Dismantling of D.P. including the work of dismanling of all accessories and connected HT/LT Line connections.

2

-

-

... More
Replacement of Damaged wooden cross arms by 11 KV ‘V’ type cross arms after opening the bindings and removal of 11 KV Pin insulators and fixing of new ‘V’ type cross arms and binding properly and other related works.

2

-

-

... More
Removal & Replacement of defective/damaged LT Pin clamp/stay clamp/double Pole Clamp/Cross arm holding clamp/F Clamp by new clamp as per site requirement.

2

-

-

... More
Replacement of old & defective/damaged shackle insulator by new one.

10

-

-

... More
Errection of section by PCC Pole after digging a pit of size 1.20x0.75x1.75 mt

1

-

-

... More
Repair/Replacement of damaged burnt Jumpers of double pole/section pole of 11 KV/LT Line.

10

-

-

... More
Cartage of ABC Cable with junction Box & other store materials related with the work of ABC for each site/Transformer.

1

-

-

... More
Laying Lifting of ABC Cable complete in all respect as per instruction of J.E./SDO.

150

-

-

... More
Fixing of Junction Box & making connection & other related works.

2

-

-

... More
Fixing of TPMO at D/P.

1

-

-

... More
Fixing of Fuse Set at D/P.

1

-

-

... More
Replacement/Repairing of LT PVC Cable of existing T/F.:

-

-

-

... More
1-63 KVA to 100 KVA

3

-

-

... More
Water level Earthing (Neutral/Body) by providing & fixing 30 mtrs 30 mm dia GI Pipe with MS Strip 40x6 mm. lowering the same after boring of earth by 4" dia upto 30 mtr depth/water level.

1

-

-

... More
Cartage of Dismantled and removal material from site to J.E store including loading & unloading at both ends maximum distance about upto15 Km.

1

-

-

... More
Cartage of Dismantled and removal material from J.E store to Central Store Meerut including loading & unloading at both ends maximum distance about upto15 Km.

1

-

-

... More
Cartage of old/damaged T/F. from work site to JE Store including loading & unloading at both ends.

-

-

-

... More
1-63 KVA to 100 KVA

3

-

-

... More
Cartage of old/damaged T/F. from JE Store to Central Store Meerut including loading & unloading at both ends.

-

-

-

... More
2-63 KVA to 100 KVA

3

-

-

... More
Cartage of dismantled PCC Pole/STP from work site to JE Store (Distance up to 15 KM) including Loading & Unloading at both ends.

-

-

-

... More
1-PCC Pole

2

-

-

... More
Cartage of dismantled PCC Pole/STP from JE Store to Central Store Meerut.(Distance up to 50 KM) including Loading & Unloading at both ends.

-

-

-

... More
1-PCC Pole

1

-

-

... More
Removal of old/damaged T/F from exsisting D.P. after Opening the LT/HT side connections due to increasing capacity or due to any other reason.

-

-

-

... More
2-63 KVA to 100 KVA

4

-

-

... More
Dismantling of exsisting HT/LT Line by opening the binding at required place and rebinding the wire/conductor etc. as per site requirement to complete the work.

2

-

-

... More
Making new Plinth for 250/400 KVA T/F. for installation new T/F. as per RESPO Norms (all the material used shall be Provide by the Contractor).

1

-

-

... More
Making Post Card size colour Photographs before starting the work/after completion of work.

50

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.