Pashchimanchal Vidyut Vitran Nigam Limited Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Pashchimanchal Vidyut Vitran Nigam Limited - PVVNL Tender
Civil And Construction
Excavation
Eprocure
Opening Date29 Oct 2024
Closing Date11 Nov 2024
Tender Amount₹ 20,00,000
Costs
EMD
₹ 20,000Document Cost
₹ 3,540Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_PVVNL_969949_1Bid Award Id
ViewTender No
31/2024-25/EDCIMTender Authority
Pashchimanchal Vidyut Vitran Nigam Limited ViewPurchaser Address
-Website
http://http://pvvnl.org/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
11/0.4 10 KVA Transformers.
1
-
-
11/0.4 25 KVA Transformers.
1
-
-
11/0.4 63 KVA Transformers.
1
-
-
11/0.4 100 KVA Transformers.
1
-
-
11/0.4 250 KVA Transformers.
1
-
-
LT A.B.C. Cable of different size.
1
-
-
11 KV XLPE cable of size 3x70 sq.mm./ 3x120 sq.mm./ 3x180 sq.mm. etc.
1
-
-
33 KV XLPE cable of size 3x300 sq.mm./ 3x400 sq.mm. etc.
1
-
-
Line material such as Cross-Arms, Pin Insulators, Guarding Angles, Guarding Wire, Disc Insulators and Cable Jointing Kits etc.
1
-
-
CT/PT Unit
1
-
-
11 KV pilfer proof metering cubical.
1
-
-
Dismantling of the line by :-
-
-
-
Removing of ACSR Weasel/Dog conductor from all phases on line, making bundle and stacking at a safe place.
1
-
-
Removing of 33 KV/11 KV XLPE CABLE of different size from pole, making bundle and stacking at a safe place.
1
-
-
Uprooting/cutting of 13 Mtr./11 Mtr./9 Mtr./8.5 Mtr. Long PCC/ST Poles.
1
-
-
For 33 KV Line, Single support 13/11/9 Mtr. long ST Poles :- Excavation of foundation pit in size of 75x45 cm. having depth of 1/6th of the full length of the support (pole), providing and laying of stone pad (300x300x75mm.) in the bottom of the pit. Erection of support (pole) complete with fixing of 33 KV V-Type cross-arms and all other accessories by providing stone pad, cross arms, holding clamps, f-bracket and nuts & bolts etc. as per RESPO Norms.
1
-
-
For 33 KV Line, Double pole 13/11/9 Mtr. long ST Poles Excavation of foundation pit in size of 75x45 cm. having depth of 1/6th of the full length of the support (pole). Erection of support (pole) complete work by fixing of D.P. Clamps and all other accessories. The work includes fabrication work and fixing of cross bracing sets, cutting holes complete work as per RESPO Norms.
1
-
-
For 11 KV Line, Single support 13/11/9/8.5 Mtr. long ST/PCC Poles :- Excavation of foundation pit in size of 75x45 cm. having depth of 1/6th of the full length of the support (pole), providing and laying of stone pad (300x300x75mm.) in the bottom of the pit. Erection of support (pole) complete with fixing of 11 KV V-Type cross-arms and all other accessories by providing stone pad, cross arms, holding clamps, f-bracket and nuts & bolts etc. as per RESPO Norms.
1
-
-
For 11 KV Line, Double Pole structure with 13/11/9/8.5 Mtr. long ST/PCC Poles :- Excavation of foundation pit in size of 75x45 cm. having depth of 1/6th of the full length of the support (pole). Erection of support (pole) complete work by fixing of D.P. Clamps and all other accessories. The work includes fabrication work and fixing of cross bracing sets, cutting holes complete work as per RESPO Norms.
1
-
-
Construction of Tri-Pole Structure on ST Poles including fabrication of MS Angle Channel, Cross Bracing etc. with proving and fitting of all type of clamps made of MS Flat of size 65x8mm. with Nuts, Bolts & washer, grouting of pole in size of 220x45x45 cm. with Cement, Sand and Brick Ballast in the ratio of 1:4:8, as per RESPO Norms.
1
-
-
Grouting of Poles Single line support :- Grouting of support in CC 1:4:6 (cement, sand and 40 mm. brick ballast) Grouting will be done in the block of size 45cm x 45cm x 1/6th of full length of the support upto ground level as per RESPO Norms.
1
-
-
Grouting of stay rods (20x1800mm.) including all works of excavation, cement concrete in size of (0.60x0.60x0.30)M in the ratio of 1:4:6 (cement, sand and 40 mm. brick ballast) including back filling of soil and proper ramming etc.
1
-
-
Fixing, tightening and nozelling of stay wire with stay rod and stay insulators with the pole of required tension by providing stay clamps, nuts, bolts etc.
1
-
-
Earthing of support with MS Earth Rod of (20x2500)mm. long including excavation of pit and driving MS Rod 3.0M apart from support and 0.5M below the ground level and connecting below the earth electrodes with the help of G.I. Wire No.6 SWG tightening with nuts and bolts.
1
-
-
Laying, sagging, stringing and binding of ACSR Weasel/ Dog and other Conductor with all other accessories on pole as per RESPO Norms.
1
-
-
Laying, sagging, stringing and binding of ABC Conductor of different size with all other accessories on pole as per RESPO Norms.
1
-
-
Laying of 11 KV XLPE Cable of size 3x70 sq.mm./ 3x120 sq.mm./ 3x180 sq.mm. etc. and making connections as per RESPO Norms.
1
-
-
Laying of 33 KV XLPE Cable of size 3x300 sq.mm./ 3x400 sq.mm sq.mm. etc. and making connections as per RESPO Norms.
1
-
-
Filling and fixing of 33KV/11 KV outdoor/indoor type cable jointing kits as per RESPO Norms.
1
-
-
Construction of 33KV/ 11 KV Underground Line :-
-
-
-
Digging of cable trench suitable size for 33/11 kv xlpe cable.
1
-
-
Laying of 33 kv cable of size 3x300, 3x400 sqmm cable etc./11 KV 3x70/120/185 sq.mm. cable in the trench.
1
-
-
Providing sand cushion beneath above the cable. The cable shall be duly protected by 1st Class Bricks, two on either side and third on top of the cable, laid in the series one after the other.
1
-
-
Refilling and ramming of the left out soil, closing and trench and levelling. Spare cable shall be left in the loop shape at both ends, including providing of all required material and T&P.
1
-
-
Fitting of 11 KV Pilfer proof metering cubical including making proper connections.
1
-
-
Providing and fixing of Danger board with clamp, nuts and bolts on pole as per norms.
1
-
-
Providing and fixing of Number plate with clamp, nuts and bolts on pole as per norms.
1
-
-
Providing and wrapping Barbed wire on pole at a standerd height, complete work as per norms.
1
-
-
Guarding of 33KV/11 KV Line with G.I. wire as per RESPO Norms.
1
-
-
Mounting and fixing of 11 KV CT/PT Unit on double pole including making proper connections.
1
-
-
Mounting and fixing of 10 KVA transformer on pole including making proper connections.
1
-
-
Mounting and fixing of 25 KVA transformer on double pole including making proper connections.
1
-
-
Mounting and fixing of 63 KVA transformer on double pole including making proper connections.
1
-
-
Mounting and fixing of 100 KVA transformer on double pole including making proper connections.
1
-
-
Construction of plinth suitable for 250 KVA transformer by providing all type of material and T&P.Complete work as per RESPO norms.
1
-
-
Installation of 250 KVA transformer on plinth, making H.T./L.T. connections as per norms.
1
-
-
Fencing arround the 250 KVA transformer by providing all type of material and T&P.Complete work as per RESPO norms.
1
-
-
Providing G.I. Pipe 6” dia for inserting XLPE cable for safety of cable on Single/Double Pole by providing and fixing of MS Clamp, Nuts and Bolts.
1
-
-
Carriage of following from work site to Store Centre Majhola including loading and unloading at both ends :-
-
-
-
13 Mtr./11 Mtr./9 Mtr. Long ST Poles.
1
-
-
ACSR Weasel/Dog Conductor/M.S. Scrap.
1
-
-
CT/PT Unit/ 11 KV pilfer proof metering cubical.
1
-
-
11/0.4 63 KVA Transformers.
1
-
-
11/0.4 250 KVA Transformers.
1
-
-
33 KV/11 KV XLPE cable of different size.
1
-
-
Evaluation Notes How It Works ?