Pashchimanchal Vidyut Vitran Nigam Limited Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Pashchimanchal Vidyut Vitran Nigam Limited - PVVNL Tender
Civil And Construction
Civil Works Others
Eprocure
Opening Date14 Oct 2024
Closing Date21 Oct 2024
Tender Amount₹ 8,00,000
Costs
EMD
₹ 8,000Document Cost
₹ 1,180Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_PVVNL_962795_2Bid Award Id
ViewTender No
39/EDC-III/B/2024-2025Tender Authority
Pashchimanchal Vidyut Vitran Nigam Limited ViewPurchaser Address
-Website
http://http://pvvnl.org/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
S.T.P.Pole 11 Mtr. Long
10
-
-
Carriage of All line Material from store center BSR to j.e store Sub station as ACSR Weasel conductor, ABC conductor & cable GI Wire, Earth Wire. M.S. Chanel, Angle, Stay & Earthig Rods, Barbed Wire. Disc Insulator etc.
50
-
-
Erection of Single pole support including complete 1 IT fittings as per RESPO manual and as per direction of Engineer in charge including the cost of labour, T&P and carrier etc. required for proper completion of work.
35
-
-
Erection of Double pole/Scation Pole support including complete 1 IT fittings as per RESPO manual and as per direction of Engineer in charge including the cost of labour, T&P and carrier etc. required for proper completion of work.
10
-
-
Grouting of Single support shall be grouted with cement, sand and birck ballast/stone ballast in including the cost of cement, sand, birck ballast/stone ballast, etc. as per actual size requirement, as per RESPO manual and as per direction of Engineer in charge including the cost of labour, T&P and carrier etc. required for proper completion of work.
35
-
-
Grouting of Double pole support shall be grouted with cement, sand and birck ballast/stone ballast in including the cost of cement, sand, birck ballast/stone ballast, etc. as per actual size requirement, as per RESPO manual and as per direction of Engineer in charge including the cost of labour, T&P and carrier etc. required for proper completion of work.
10
-
-
Carriage of All line Material from J.E store Sub station to Pit Site ACSR Weasel conductor, ABC conductor GI Wire, Earth Wire. M.S. Chanel, Angle, Stay & Earthig Rods, Barbed Wire. Disc Insulator etc.
50
-
-
Cutting /drilling /Welding of MS Angle iron for making guarding angle size 65x65x6/50x50x6 mm including the work of fixing the bracket on PCC/ST pole for construction of the line.
1350
-
-
Carriage of 11 Kv CT/PT metering polemounted unit Varius ratio
2
-
-
Carriage and installation of 11 Kv Pilferresistant metering cubicle with out cable termination kit
2
-
-
Mounting of 11 KV CT/PT Unit Varius ratio
2
-
-
Carriage of T/F from ESC. BSR to pit site on kachcha pacaa road including loading and unloading chagres at both ends, rcquricd for proper completion of work, distance about to 60 Kms.
-
-
-
25 KVA T/F
2
-
-
63 KVA T/F
3
-
-
100 KVA T/F
1
-
-
fixing of 11 Kv Stay rod with Stay wire in proper way with Nozelling
30
-
-
Grouting of 11 Kv Stay rods
30
-
-
Laying, sagging. Stringing and binding and jumpering of 11 Kv XLPE cable 3*70/120/185 Square MM & Outher size newly erected pole as per RESPO manual and as per direction of supervising engineer. It includes the cost of labour, T&P, carrier etc. requried for proper completion of work.
250
-
-
Laying, sagging. Stringing and binding and jumpering of ACSR Weisal , rabbit, dog newly erected pole as per RESPO manual and as per direction of supervising engineer. It includes the cost of labour, T&P, carrier etc. requried for proper completion of work.
-
-
-
ACSR weisal conductor
1500
-
-
ACSR Rabbit/Dog conductor
650
-
-
ABC Cable 3*50 Square MM
240
-
-
ABC Cable 3*95 Square MM
240
-
-
Fixing of Earthing rod
48
-
-
Fixing of pin insulator
130
-
-
Fixing disc insulator
78
-
-
Fixing of Toff Channel
25
-
-
Fixing of Sub station Angle.
22
-
-
Mounting & Installation of T/F From D/P
-
-
-
25 KVA T/F
2
-
-
63 KVA T/F
3
-
-
100 KVA T/F
1
-
-
The folloing material is required to be supplied by the contractor.
-
-
-
DISTRIBUTION BOX 3 PHASE Complet
10
-
-
Providing & Fixing of Chemicle earthing.
4
-
-
Holding clamp.
70
-
-
11Kv Cable Jointing kit 3*70 Square mm XLPE cable
4
-
-
Double Pole clamp
25
-
-
Fuse set
5
-
-
F Clamp
50
-
-
LT Clamp
30
-
-
PG Clamp
30
-
-
J hook
30
-
-
Earth clamp
40
-
-
Stay clamp
30
-
-
dead & clamps
38
-
-
Stay insulator
30
-
-
Suspension clamps
40
-
-
LT Insulator
40
-
-
Bolt & nut off size.
200
-
-
Extra Milage charges and carriage from PCC/ST Pole & other material from each 10 Km.
1
-
-
Above work shall be done as per UPPCL/RESPO Rules.
-
-
-