Pashchimanchal Vidyut Vitran Nigam Limited Tender
... More
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of etender.up.nic.in - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Pashchimanchal Vidyut Vitran Nigam Limited - PVVNL Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date15 Jan 2025
Closing Date3 Feb 2025
Tender Amount₹ 10,00,000
Costs
EMD
₹ 10,000Document Cost
₹ 1,180Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_PVVNL_993404_1Bid Award Id
ViewTender No
E.T.No.47(W)/EDCH/2024-25Tender Authority
Pashchimanchal Vidyut Vitran Nigam Limited ViewPurchaser Address
-Website
http://http://pvvnl.org/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Carriage of 250 KVA T/F from Electricity store center, Hapur to site of work with loading and unloading at both ends on Kachha Packka road, as per direction of site incharge.
4
-
-
... More
Erection & Fixing of PCC Pole 8.5 mtr. long in LT. line after digging of suitable pits including fixing of requisite accessories as per RESPO Drawing/ Norms by providing L.T. Pin Clamps, M.S. Flat of size 50x6 & Schacle Insulator of size 75x90mm, with proper size nuts and bolts, as per direction of site incharge.
128
-
-
... More
Erection of double pole structure with all accessories on PCC Pole 8.5 mtr. long, fabrication and fixing of M.S. Top & Dropper Channel, M.S. T/F Angle, E-Bracket, 11 KV Pin insulator with Pin, Disc Insulator with Disc fitting etc., as per RESPO Drawing/Norms by providing all clamps made of M.S. Flat of size 50x6 mm with proper size nuts and bolts, and jumpering etc work, as per direction of site incharge.
4
-
-
... More
Safely installing the New 250KVA transformer with the help of crane/manual labour at LT Sub-Station Double Pole/Plinth, as per direction of site incharge.(Work includes all connection properly for energisation of Transformers).
4
-
-
... More
Laying of LT XLPE Cable Aluminum 1X400 sqmm and completion work properly, as per RESPO/Norms, and as per direction of site incharge.
80
-
-
... More
Laying of LT ABC 3x95+1x70+1x16 sq.mm. completion work properly, as per RESPO/Norms, and as per direction of site incharge. (Execpt cable all material will be provided by the Contractor).
2400
-
-
... More
Erection & Fixing of 3 Phase 4 wire L.T. Distribution Box on pole by provding 02 Nos. D/B Clamps & proper size nut & bolts, as per direction of site incharge.(with making all connection of AB Cable to Distribution Box properly).
80
-
-
... More
Providing and fixing of P.R.C FOR ABC as per RESPO/Norms and as per direction of site incharge.
320
-
-
... More
Providing and fixing of Dead End Clamp with Eye Hook, as per RESPO/ Norms and as per direction of site incharge.
30
-
-
... More
Providing and fixing of Holding Clamp as per RESPO/Norms and as per direction of site incharge.
160
-
-
... More
Providing and fixing of Aluminum Lug suitable for 400 sq.mm. cable. as per RESPO/Norms and as per direction of site incharge.
16
-
-
... More
Grouting & fixing of stay rods (20x1800)mm including all work of excavation, cement concrete in size (0.60x0.60x0.30)m in ratio 1:4:8 cement, sand, 40mm brick ballast as per drg. Including back filling, proper ramming etc and fixing tightening & nozzling of stay wire with stay rod with the poles of required tension as per drawing as per RESPO Drawing/Norms by providing all grouting material and stay clamp made of M.S. Flat of size 50x6mm with proper size bolts & nuts & loops, as per direction of site incharge.
20
-
-
... More
Grouting of ST/PCC supports in CC 1:4:8 (Cement, sand & 40mm brick ballast) Grouting will be done in the block of size (450x450)mm x1/6th of full length of the support, up to ground level, 300mm plinth above the ground level with CC 1:3:6 (Cement, core sand and Stone grit) with mufting as per drawing, work includes back filling & proper ramming by providing all required grouting materials, as per direction of site incharge.
136
-
-
... More
Laying , Stringing and final sagging of ACSR Weasel Conductor, as per RESPO/Drawing Norms and as per direction of site incharge.
200
-
-
... More
Construction of T/F plinth suitable for 250KVA T/F (size of 2 x 2 x 1.5 mt.) as per drawing, cc work in foundation in ratio 1:4:8 (Cement, Sand & Brick ballast). Ist class brick work in side walls cc ratio of 1:4 (cement & fine sand). 12mm thick plaster in ratio 1:4 (cement & fine sand). The RCC work on top of plinth in ratio 1:2:4 after duly filling of brick ballast inside the plinth & ramming the same, including cost of all material & labour, as per direction of site incharge.
4
-
-
... More
Providing and Fixing Chemical Earthing with 50x3000 mm size Earthing rod and 50 Kg. Chemical each earthing for Transformers Equipment the ground surface where it will be bolted to the G.I. earth strip of size 50x6 mm for connection the earth strip will be welded to the earthing and neutral support, as per RESPO/Normas. (All material will be provided by Contractor).
16
-
-
... More
Construction of safety fencing (MS) for Transformer 11/0.4 KV Sub Station, size of 3x3x3 mtr. With supply of material required for MS fencing (50X50X3 MM) M.S. wire mesh construction utilizing vertical post duly grouted/fitted in ground/on floor. Horizontal angle/T-iron to be fitted on vertical posts. Pickets (if required) fitted to rail and gate to facilitate entry and exit. The vertical Posts/Horizontal post shall be made of M.S. angle 75x75x6mm. Such post shall be kept preferably at distance of 800-1000 MM. and shall be grounded with CC ratio 1:4:8. The length of vertical post shall be sufficient to take care of fencing as requirement at site, and as per direction of site incharge.
4
-
-
... More
Jumpering and line energisation work properly as per RESPO/Norms and as per direction of site incharge.
4
-
-
Evaluation Notes How It Works ?