Pashchimanchal Vidyut Vitran Nigam Limited Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Pashchimanchal Vidyut Vitran Nigam Limited - PVVNL Tender
Agriculture or Forestry Works
Eprocure
Opening Date21 Nov 2024
Closing Date27 Nov 2024
Tender AmountRefer Documents
Costs
EMD
₹ 24,000Document Cost
₹ 3,540Tender Fee
Refer Documents
Summary
E-tender No. 49/2024-25, Eudc-ii Noida
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_PVVNL_968016_2Tender No
E-Tender No. 49/2024-25, EUDC-II NoidaTender Authority
Pashchimanchal Vidyut Vitran Nigam Limited ViewPurchaser Address
-Website
http://http://pvvnl.org/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
PCC POLE 8.5MTR
12
-
-
STONE PAD
32
-
-
11KV XLPE 3X185
900
-
-
11KV O/D KIT
20
-
-
LT AB CABLE 3X120
1200
-
-
DOG CONDUCTOR
9000
-
-
11KV CROSS ARM
24
-
-
11KV T OFF CHANNEL
10
-
-
11KV PIN INSULATIOR
80
-
-
11KV DISC INSULATOR
30
-
-
EARTHING COMPLETE
32
-
-
STAY SET COMPLETE
10
-
-
GUARDING ANGLE 65X65X6
72
-
-
Errection of above Following material and Supply and errection of the DE-CENTRALISED material for completing the works as per RESPO.
-
-
-
The excavation of foundation pit in mix soil/normal soil/soft soil & hard rock as per site condition and its back filling and leveling etc. The size of the pit will be (750x450)mm and having depth of 1/6th of the full length of the support. Erection of support, complete with providing & fixing of all G.I.Clamps size of 75x10mm, 65x8mm, G.I.Nut bolt & washer, P.G.Clamp, Stone Pad, Al. Binding wire, 'E' bracket 75x10mm, and other accessories as per drawing. The work includes carriage and handling of supports from sectional store to pit site as well as any fabrication work if required & fixing of cross bracing sets 4.3mtr long, from G.I.Angle 65x65x6mm. The work includes cutting holes and providing G.I.Bolt of 16x40mm size, in the middle of the cross bracing with 01No. spring washer of proper size as per drawing/ as per schedule.
Double Pole Structures
(a) ST POLE 11MTR
2
-
-
The excavation of foundation pit in mix soil/normal soil/soft soil & hard rock as per site condition and its back filling and leveling etc. The size of the pit will be (750x450)mm and having depth of 1/6th of the full length of the support. Erection of support, complete with providing & fixing of all G.I.Clamps size of 75x10mm, 'F' bracket 75x10mm, G.I.Nut bolt & washer, Stone Pad Al. Binding wire and other accessories as per drawing. The work includes carriage and handling of supports from sectional store to pit site as well as an fabrication work if required.
Single Pole
(a) ST POLE 11 MTR AND PCC POLE 8.5MTR
28
-
-
Grouting of supports in CC 1:3:6 (Cement, sand & 20mm stone grift). Grouting will be done in the block of size (450x450)mm x1/6th of full length of the support, upto ground level, 300mm plinth above the ground level with C.C. 1:3:6 (Cement, Course sand and Stone grift) with muffing as per RESPO. Work includes back filling and proper ramming.
Single Pole and Double Pole
(a) ST POLE 11 MTR AND PCC POLE 8.5MTR
32
-
-
FIXING OF PIN INSULATOR WITH PIN, COMPLETE WORK IN ALL RESPECT.
80
-
-
FIXING OF T OFF CHANNEL AS PER SITE REQUIREMENT.
10
-
-
FIXING OF CROSS ARM AS PER SITE REQUIREMENT.
24
-
-
FIXING OF STONE PAD AS PER SITE REQUIREMENT.
32
-
-
FIXING OF 11KV DISC INSULATOR WITH FITTINGS AS PER SITE REQUIREMENT.
30
-
-
FIXING OF GUARDING ANGLES AS PER SITE REQUIREMENT
72
-
-
Supply of 160mm OD PN-4-PE-80 Grade UV Stabilized HDPE Pipe.(PVVNL GTP APPROVED)
400
-
-
Drilling of dia 220 mm in two parallel bores for Double Curcuit by trenchless method by horizontal boring machine at a depth of 1.50 mtrs to 2.50 mtrs. (as requirement at site) below the ground level with complete work in all respect as per RESPO.
400
-
-
Laying of HDPE Pipe PE-80, PN-4, DN-160mm dia by HDD trenchless method for 11KV, 3x185sq.mm XLPE cable as per site requirement. (PVVNL GTP APPROVED HDPE PIPE SHALL BE SUPPLIED WITH INSPECTION.)
400
-
-
Laying and commissiong of 11KV 3x185sqmm XLPE Cable Double Ckt. in HDPE Pipe dia after digging HDD trenchless method boring including complete connections at both ends after providing and crimping of lugs of proper size for completion of work. as per site requirement.
400
-
-
Digging of pits of size 4 mtr x 4 mtr x 1.5 mtr for cable loop and making risers at double pole and re-filling of pits in proper manner with required material at kacha/pakka and hot mix road. (All Work and material in the scope of contractor)
4
-
-
Laying, Sagging, connecting, Re-sagging of overhead 11 KV 3X185 Sq.mm XLPE Cablemaking connection complete at both ends as per site requirement.
500
-
-
Preparation and Fixing of 11 KV Power Cable ends:
Making and Fixing of 11 KV XLPE Heat shrinkable outdoor jointing kits suitable for 3x185sqmm XLPE Cable after duly plumbing and taping of cable, providing, fixing and crimping of proper size good quality lugs with complete connention in all respect.
20
-
-
Driving of MS earth rod of size 20x2500 mm in earth and jointing through G.I. wire of 6 SWG between support and earth electrode by providing proper size of bolts and nuts for pole earthing. Supply Erection, fixing, grouting of stay rod in cement, sand and brick ballast in ration 1:4:8 in Block 600*600*300 mm with binding & nuzzling including providing & fixing of stay insulator complete in all respect with grouting. (All Work and Material in the scope of Contractor)
32
-
-
Laying, spreading, lifting and final sagging of 3 OR 4 phases ACSR Dog conductor in accordance with Line chart includidng binding and fixing of all accessories in 03Nos OR 04 Nos. Conductor in parallel as per site requirement.
9000
-
-
Laying, spreading, lifting and final sagging of AB Cable 3x120sqmm in accordance with Line chart includidng binding and fixing of all accessories as per site requirement.
1200
-
-
Fixing, tightening & nozzling of stay set with wire and stay rod with the poles of required tension as per drawing, including providing & fixing of Stay Insulators of 11KV and Stay Clamps and Grouting of stay rods (20x1800)mm including all work of excavation, cement concrete in size (0.60x0.60x0.30)m in ratio 1:3:6 cement, sand, 20mm Stone grift) as per drg. Including back filling of soil and proper ramming etc.
10
-
-
PROVIDING AND FIXING OF HOLDING CLAMP AS PER REQUIREMENT.
240
-
-
PROVIDING AND FIXING OF EYE BOLTS AS PER REQUIREMENT.
216
-
-
PROVIDING AND FIXING OF NUT BOLT AND WASHERS AS PER REQUIREMENT
70
-
-
PROVIDING AND FIXING OF PG CLAMP (DOG TO DOG) AS PER REQUIREMENT
30
-
-
PROVIDING AND FIXING OF 11KV F BRACKET AS PER REQUIREMENT
24
-
-
Providing and Fixing of GI Wire 4&8 SWG 1/5mm as per site requirement.
525
-
-
Road Cutting and Road Restoration Charges for the above work.
1
-
-
TREE CHOPPING AND CUTTING IN THE WAY OF LINE BY BOOM BARRIER MACHINE.
30
-
-
Removal and Dismentaling of old and used Conductor from the site and safe carriage of its from the site to any store of PVVNL DISCOM including loading and un-loading both ends.
800
-
-
Removal and Dismentaling of old and Damaged PCC Pole from the site and safe carriage of its from the site to any store of PVVNL DISCOM including loading and un-loading both ends.
8
-
-
Removal and Dismentaling of old and Damaged ST Pole from the site and safe carriage of its from the site to any store of PVVNL DISCOM including loading and un-loading both ends.
700
-
-
Removal and Dismentaling of old and Damaged Cross Arm from the site and safe carriage of its from the site to any store of PVVNL DISCOM including loading and un-loading both ends.
240
-
-
RE-ARRANGEMENT OF DAMAGED CONDUCTOR AT KRISHNA FLOOR MILL
-
-
-
Safe carriage of following stock material, from any of the Store Center of PVVNL to work site including Loading from Store and safe unloading at site for Item No. 52 TO 63
-
-
-
11KV XLPE 3X185
1080
-
-
11KV O/D KIT
1
-
-
11KVI/D KIT
12
-
-
11KV TOP CHANNEL
5
-
-
11KV DROPPER CHANNEL
12
-
-
DOG CONDUCTOR
2200
-
-
ST POLE 11MTR
32
-
-
11KV PIN INSULATIOR
45
-
-
11KV DISC INSULATOR
18
-
-
11KV CROSS ARM
15
-
-
EARTHING COMPLETE
32
-
-
STAY SET COMPLETE
4
-
-
Errection of above Following material and Supply and errection of the DE-CENTRALISED material for completing the works as per RESPO.
-
-
-
The excavation of foundation pit in mix soil/normal soil/soft soil & hard rock as per site condition and its back filling and leveling etc. The size of the pit will be (750x450)mm and having depth of 1/6th of the full length of the support. Erection of support, complete with providing & fixing of all G.I.Clamps size of 75x10mm, 65x8mm, G.I.Nut bolt & washer, P.G.Clamp, Stone Pad, Al. Binding wire, 'E' bracket 75x10mm, and other accessories as per drawing. The work includes carriage and handling of supports from sectional store to pit site as well as any fabrication work if required & fixing of cross bracing sets 4.3mtr long, from G.I.Angle 65x65x6mm. The work includes cutting holes and providing G.I.Bolt of 16x40mm size, in the middle of the cross bracing with 01No. spring washer of proper size as per drawing/ as per schedule.
Double Pole Structures
(a) ST POLE 11MTR
6
-
-
The excavation of foundation pit in mix soil/normal soil/soft soil & hard rock as per site condition and its back filling and leveling etc. The size of the pit will be (750x450)mm and having depth of 1/6th of the full length of the support. Erection of support, complete with providing & fixing of all G.I.Clamps size of 75x10mm, 'F' bracket 75x10mm, G.I.Nut bolt & washer, Stone Pad Al. Binding wire and other accessories as per drawing. The work includes carriage and handling of supports from sectional store to pit site as well as an fabrication work if required.
Single Pole
(a) ST POLE 11 MTR AND PCC POLE 8.5MTR
20
-
-
Grouting of supports in CC 1:3:6 (Cement, sand & 20mm stone grift). Grouting will be done in the block of size (450x450)mm x1/6th of full length of the support, upto ground level, 300mm plinth above the ground level with C.C. 1:3:6 (Cement, Course sand and Stone grift) with muffing as per RESPO. Work includes back filling and proper ramming.
Single Pole and Double Pole
(a) ST POLE 11 MTR AND PCC POLE 8.5MTR
32
-
-
FIXING OF PIN INSULATOR WITH PIN, COMPLETE WORK IN ALL RESPECT.
45
-
-
FIXING OF TOP CHANNEL AS PER SITE REQUIREMENT.
5
-
-
FIXING OF DROPPER CHANNEL AS PER SITE REQUIREMENT.
12
-
-
FIXING OF 11KV DISC INSULATOR WITH FITTINGS AS PER SITE REQUIREMENT.
18
-
-
FIXING OF CROSS ARM AS PER SITE REQUIREMENT
15
-
-
Supply of 160mm OD PN-4-PE-80 Grade UV Stabilized HDPE Pipe.(PVVNL GTP APPROVED)
360
-
-
Drilling of dia 220 mm in two parallel bores for Double Curcuit by trenchless method by horizontal boring machine at a depth of 1.50 mtrs to 2.50 mtrs. (as requirement at site) below the ground level with complete work in all respect as per RESPO.
360
-
-
Laying of HDPE Pipe PE-80, PN-4, DN-160mm dia by HDD trenchless method for 11KV, 3x185sq.mm XLPE cable as per site requirement. (PVVNL GTP APPROVED HDPE PIPE SHALL BE SUPPLIED WITH INSPECTION.)
360
-
-
Laying and commissiong of 11KV 3x185sqmm XLPE Cable Double Ckt. in HDPE Pipe dia after digging HDD trenchless method boring including complete connections at both ends after providing and crimping of lugs of proper size for completion of work. as per site requirement.
360
-
-
Digging of pits of size 4 mtr x 4 mtr x 1.5 mtr for cable loop and making risers at double pole and re-filling of pits in proper manner with required material at kacha/pakka and hot mix road. (All Work and material in the scope of contractor)
6
-
-
Laying, Sagging, connecting, Re-sagging of overhead 11 KV 3X185 Sq.mm XLPE Cablemaking connection complete at both ends as per site requirement.
720
-
-
Preparation and Fixing of 11 KV Power Cable ends:
Making and Fixing of 11 KV XLPE Heat shrinkable outdoor jointing kits suitable for 3x185sqmm XLPE Cable after duly plumbing and taping of cable, providing, fixing and crimping of proper size good quality lugs with complete connention in all respect.
1
-
-
Preparation and Fixing of 11 KV Power Cable ends:
Making and Fixing of 11 KV XLPE Heat shrinkable Inddoor jointing kits suitable for 3x185sqmm XLPE Cable after duly plumbing and taping of cable, providing, fixing and crimping of proper size good quality lugs with complete connention in all respect.
12
-
-
Driving of MS earth rod of size 20x2500 mm in earth and jointing through G.I. wire of 6 SWG between support and earth electrode by providing proper size of bolts and nuts for pole earthing. Supply Erection, fixing, grouting of stay rod in cement, sand and brick ballast in ration 1:4:8 in Block 600*600*300 mm with binding & nuzzling including providing & fixing of stay insulator complete in all respect with grouting. (All Work and Material in the scope of Contractor)
32
-
-
Laying, spreading, lifting and final sagging of 3 OR 4 phases ACSR Dog conductor in accordance with Line chart includidng binding and fixing of all accessories in 03Nos OR 04 Nos. Conductor in parallel as per site requirement.
2200
-
-
Fixing, tightening & nozzling of stay set with wire and stay rod with the poles of required tension as per drawing, including providing & fixing of Stay Insulators of 11KV and Stay Clamps and Grouting of stay rods (20x1800)mm including all work of excavation, cement concrete in size (0.60x0.60x0.30)m in ratio 1:3:6 cement, sand, 20mm Stone grift) as per drg. Including back filling of soil and proper ramming etc.
4
-
-
PROVIDING AND FIXING OF HOLDING CLAMP AS PER REQUIREMENT.
56
-
-
PROVIDING AND FIXING OF NUT BOLT AND WASHERS AS PER REQUIREMENT
30
-
-
PROVIDING AND FIXING OF PG CLAMP (DOG TO DOG) AS PER REQUIREMENT
12
-
-
PROVIDING AND FIXING OF ISI MARKED GI PIPE 6" DIA AS PER REQUIREMENT
48
-
-
Providing and Fixing of F BRACKET as per site requirement.
15
-
-
Road Cutting and Road Restoration Charges for the above work.
1
-
-
TREE CHOPPING AND CUTTING IN THE WAY OF LINE BY BOOM BARRIER MACHINE.
20
-
-
Removal and Dismentaling of old and used Conductor from the site and safe carriage of its from the site to any store of PVVNL DISCOM including loading and un-loading both ends.
200
-
-
Removal and Dismentaling of old and Damaged PCC Pole from the site and safe carriage of its from the site to any store of PVVNL DISCOM including loading and un-loading both ends.
8
-
-
Removal and Dismentaling of old and Damaged ST Pole from the site and safe carriage of its from the site to any store of PVVNL DISCOM including loading and un-loading both ends.
500
-
-
Removal and Dismentaling of old and Damaged Cross Arm from the site and safe carriage of its from the site to any store of PVVNL DISCOM including loading and un-loading both ends.
240
-
-
U/G CROSSING FOR 11KV CLAVE CONE MES
-
-
-
Safe carriage of following stock material, from any of the Store Center of PVVNL to work site including Loading from Store and safe unloading at site for Item No. 97 TO 104
-
-
-
11KV XLPE 3X185 cable
620
-
-
ST POLE 11MTR
12
-
-
STONE PAD
12
-
-
11KV DISC INSULATOR
18
-
-
11KV O/D KIT
16
-
-
EARTHING COMPLETE
12
-
-
TOP CHANNEL
5
-
-
DROPPER CHANNEL
15
-
-
Errection of above Following material and Supply and errection of the DE-CENTRALISED material for completing the works as per RESPO.
-
-
-
The excavation of foundation pit in mix soil/normal soil/soft soil & hard rock as per site condition and its back filling and leveling etc. The size of the pit will be (750x450)mm and having depth of 1/6th of the full length of the support. Erection of support, complete with providing & fixing of all G.I.Clamps size of 75x10mm, 65x8mm, G.I.Nut bolt & washer, P.G.Clamp, Stone Pad, Al. Binding wire, 'E' bracket 75x10mm, and other accessories as per drawing. The work includes carriage and handling of supports from sectional store to pit site as well as any fabrication work if required & fixing of cross bracing sets 4.3mtr long, from G.I.Angle 65x65x6mm. The work includes cutting holes and providing G.I.Bolt of 16x40mm size, in the middle of the cross bracing with 01No. spring washer of proper size as per drawing/ as per schedule.
Double Pole Structures
(a) ST POLE 11MTR
4
-
-
The excavation of foundation pit in mix soil/normal soil/soft soil & hard rock as per site condition and its back filling and leveling etc. The size of the pit will be (750x450)mm and having depth of 1/6th of the full length of the support. Erection of support, complete with providing & fixing of all G.I.Clamps size of 75x10mm, 'F' bracket 75x10mm, G.I.Nut bolt & washer, Stone Pad Al. Binding wire and other accessories as per drawing. The work includes carriage and handling of supports from sectional store to pit site as well as an fabrication work if required.
Single Pole
(a) ST POLE 11 MTR AND PCC POLE 8.5MTR
4
-
-
Grouting of supports in CC 1:3:6 (Cement, sand & 20mm stone grift). Grouting will be done in the block of size (450x450)mm x1/6th of full length of the support, upto ground level, 300mm plinth above the ground level with C.C. 1:3:6 (Cement, Course sand and Stone grift) with muffing as per RESPO. Work includes back filling and proper ramming.
Single Pole and Double Pole
(a) ST POLE 11 MTR AND PCC POLE 8.5MTR
12
-
-
FIXING OF TOP CHANNEL AS PER SITE REQUIREMENT.
5
-
-
FIXING OF DROPPER CHANNEL AS PER SITE REQUIREMENT.
15
-
-
FIXING OF 11KV DISC INSULATOR WITH FITTINGS AS PER SITE REQUIREMENT.
18
-
-
FIXING OF 11KV STONE PAD AS PER SITE REQUIREMENT.
12
-
-
Supply of 160mm OD PN-4-PE-80 Grade UV Stabilized HDPE Pipe.(PVVNL GTP APPROVED)
460
-
-
Drilling of dia 220 mm in two parallel bores for Double Curcuit by trenchless method by horizontal boring machine at a depth of 1.50 mtrs to 2.50 mtrs. (as requirement at site) below the ground level with complete work in all respect as per RESPO.
460
-
-
Laying of HDPE Pipe PE-80, PN-4, DN-160mm dia by HDD trenchless method for 11KV, 3x185sq.mm XLPE cable as per site requirement. (PVVNL GTP APPROVED HDPE PIPE SHALL BE SUPPLIED WITH INSPECTION.)
460
-
-
Laying and commissiong of 11KV 3x185sqmm XLPE Cable Double Ckt. in HDPE Pipe dia after digging HDD trenchless method boring including complete connections at both ends after providing and crimping of lugs of proper size for completion of work. as per site requirement.
460
-
-
Digging of pits of size 4 mtr x 4 mtr x 1.5 mtr for cable loop and making risers at double pole and re-filling of pits in proper manner with required material at kacha/pakka and hot mix road. (All Work and material in the scope of contractor)
4
-
-
Laying, Sagging, connecting, Re-sagging of overhead 11 KV 3X185 Sq.mm XLPE Cable making connection complete at both ends as per site requirement.
160
-
-
Preparation and Fixing of 11 KV Power Cable ends:
Making and Fixing of 11 KV XLPE Heat shrinkable outdoor jointing kits suitable for 3x185sqmm XLPE Cable after duly plumbing and taping of cable, providing, fixing and crimping of proper size good quality lugs with complete connention in all respect.
16
-
-
Driving of MS earth rod of size 20x2500 mm in earth and jointing through G.I. wire of 6 SWG between support and earth electrode by providing proper size of bolts and nuts for pole earthing. Supply Erection, fixing, grouting of stay rod in cement, sand and brick ballast in ration 1:4:8 in Block 600*600*300 mm with binding & nuzzling including providing & fixing of stay insulator complete in all respect with grouting. (All Work and Material in the scope of Contractor)
12
-
-
PROVIDING AND FIXING OF HOLDING CLAMP AS PER REQUIREMENT.
48
-
-
PROVIDING AND FIXING OF ISI MARKED GI PIPE 6" DIA AS PER REQUIREMENT
48
-
-
Road Cutting and Road Restoration Charges for the above work.
1
-
-
TREE CHOPPING AND CUTTING IN THE WAY OF LINE BY BOOM BARRIER MACHINE.
20
-
-