North Eastern Railway Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

North Eastern Railway - NER Tender

Works
Civil And Construction
Telecommunication Services
Consultancy Services
Civil And Architectural Services
Ireps
Opening Date22 Nov 2024
Closing Date16 Dec 2024
Tender Amount₹ 42,62,84,039.14 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Installation, wiring, testing andcommissioning of embeddedfanless PC based 4 Maintenanceterminal as per RDSO spec. No.RDSO/SPN/192/2019 Ver. 2 orlatest & RDSO TAN No. - STS/E/TAN/3007 version 1dated:02.11.12 . Note: (i)Technical requirements shall be mentioned in the tender document.

22

106203

2336481.4

... More
Modification/Alteration in existing EI (Electronic Interlocking) at Stations as per latest 5 RDSO guidelines/TAN. It includes design and modification in existing Interface and Interlocking circuits and logic of EI system including modification in the VDU (Video Display Unit)/ CCIP (Control Cum Indication Panel), Maintenance Terminal (MPC), Data Logger, Relay rack wiring. The complete work should comply with the latest RDSO specifications and guidelines and as per approved SIP and circuit diagrams. All the material (Interface cards/relays/wiring/ material/ connectors/ fuses/ relay rack/ communication devices etc.) shall be provided by the contractor. The work also includes the supply of modified Selection table, Interface Circuits, VDU/ CCIP diagram etc. to suit the modified SIP. It also includes the carrying out of FAT, SAT (as applicable) jointly with Railways and satisfactory commissioning. All plans/ drawings/ circuits etc. should be prepared on AUTOCAD, approved softcopy to be supplied on Pen Drive and 06 sets of approved hard copies are also to be supplied. (Inspection by RDSO. However, items not covered under RDSO inspection will be inspected by consignee with manufacturer certificate.)

2

1836181

3672363.92

... More
Supply of Set of Spares for Electronic Interlocking System of RDSO Specification No. RDSO/SPN/192/2019 Version 2 with latest amendments/revisions, if any. Each set shall consist of 10% 6 of each type of cards & sub-assemblies of EI system used in one EI Auto Relay Hut subject to minimum one card if 10% is less than one. Note: For this item, Tenderer should submit details of Individual Cards/ Modules with Item wise details, Rate and Quantity along with Offer in Proforma attached as Annexure - 'D' of Financial Bid Document. (Inspection by RDSO. However, items not covered under RDSO inspection will be inspected by consignee with manufacturer certificate.)

1

1530578

1530578.78

... More
Installation, wiring, testing & commissioning of complete Electronic Interlocking System 7 as per RDSO Specification No. RDSO/SPN/192/2019 Version 2 (with latest amendment/ revision, if any) with Hot Standby and all other required accessories for functioning of Signalling System of Auto Relay Huts at mid sections. (ONE Job = ONE Auto Relay Hut)

12

432447

5189370.12

... More
Supply of Tools for EI System of standard make as per Annexure-E. (Inspection By Consignee.)

1

226326

226326.44

... More
Supply of Multi section Digital Axle Counter (MSDAC) complete System including central evaluators, processors, final track clearance relay for each track section, Rest Boxes, Monitoring consoles, Diagnostic PC/Laptop of suitable configuration, LV boxes, detection points, mushroom housing for track side electronic, deflector plates and all other accessories as per RDSO's specification No. RDSO/SPN/176/2013 (Ver.3) with latest amendment/revision as per Technical Specification and Scope of Work mentioned in Tender Document. (Unit is per Detection Point (DP).Note: 1. There will be 12 Auto Relay Huts (ARH) in complete section where MSDAC systems are to be installed. There shall be 1 minimum TWO nos. Central Evaluators per ARH i.e. minimum 24 nos. of Central Evaluators with all required accessories for 12 nos. of ARH. 2. Detection points are to be provided in redundancy on UP & DN line as per SIP/Roll Plan of ABS section enclosed. One Central Evaluator shall control main Detection Points of one line and standby Detection Points of another line and vice versa. 3. Track sections controlled by one Central Evaluator of ARH will vary from 6 track sections to 12 track sections depending upon nos. of auto signals controlled from ARH. 4. Auto preparatory reset shall be provided in main & standby track section in case one system fails as well as supervisory reset feature. In case of both system failing simultaneously, manual preparatory reset through cooperation to be provided. (Inspection by RDSO. However, items not covered under RDSO inspection will be inspected by consignee with manufacturer certificate.) (DP = Number)

368

346483

127505843.36

... More
Installation, testing and commissioning of MSDAC complete set with all accessories consisting of complete indoor and outdoor equipment including reset box and monitoring console as per RDSO's specification No. RDSO/SPN/176/2013 (Ver.3) with latest amendment/ revision of required track section as per Technical Specification and Scope of Work mentioned in Tender Document. It 2 includes transportation from SSE/Depot to site of work. It also includes installation of protective cover like Mushroom or Location Box (if required as per OEM design), grouting of MSDAC Racks/Cabinets, Rest Boxes, LV Boxes, maintenance free earth as per specification of RDSO (if required as per OEM design) etc. with supply of cement, concrete, sand, nuts, bolts etc. It also includes supply of HDPE pipe for laying of transmitter and receiver cable, digging of trench under track upto location /mushroom housing. All other accessories required for commissioning will be provided by contractor. This includes supply of design, pre installation checklist and documentation of installation. (DP = Number)

368

14252

5244971.52

... More
Supply of Tool Kit for Digital Axle Counter (suitable for MSDAC complying to the RDSO Specification No. RDSO/SPN/176/2013/Ver.3 or latest) & Test Panel including Meter for testing of track equipment, tools for monitoring & adjustment of track equipment and standard jig for drilling holes in a 3 rail. It should be as per principal manufacturing (OEM) recommended list adequate for installation, day to day maintenance and adjustment of indoor and outdoor gears. The tool kit shall be equipped with the atleast following minimum equipments: (i). All mechanical tools shall be of reputed make like Taparia/Bosch etc. (ii). Digital multimeter true RMS type of make Fluke 189 or similar reputed make with probe set- 1 no. (iii). Adjustable Torque Wrenches 25-135 N/mtr with 13 mm and 19 mm inserts-1 Set. (iv). Set of spanners screw drivers and soldering iron -1 set. (v). Dummy wheel- 1 no. (vi). Marking jig -1 no. (vii). Adapter card-1 no. (viii). Extended wired socket to interface with diagnostic plug -1 no. (ix). Selector switch on panel base-1 no. (x). DAC EC card puller. (xi). Any other tools required for maintenance purpose. (Inspection by consignee).

4

124343

497372.92

... More
Supply of 5% spare Cards/Modules of all types of cards of all the Evaluators of MSDAC systems (i.e. CPU cards, power supply cards, vital communication cards, vital I/O cards, etc.) subject to 4 minimum quantity of TWO nos. of each type of cards) and FIVE sets of all types of cards of Way Side Electronics (DP) as per OEM design of MSDAC. Description of each type spare card with quantity & rate to be mentioned in Proforma attached as Annexure - 'F' of Financial Bid Document. (Inspection by RDSO. However, items not covered under RDSO will be inspected by consignee)

2

2114317

4228634.38

... More
Supply of one set of Track Device (including Tx and Rx) with 10 metre cable length suitable for one Detection Point of MSDAC as spare as per RDSO's specification No. RDSO/SPN/176/2013 (Ver.3) or latest. (Inspection by RDSO)

10

52886

528865.8

... More
Supply of Electrically Operated Lifting Barriers (110V AC operated) complete set along with pedestal driving and driven mechanism boom of 32 feet long, balancing weight, boom support and boom locking, limit switches/circuit controllers, gate operating panel, 2 booms of 32 feet length 1 etc. along with all accessories complete in all respect as per RDSO Specification No. RDSO/ SPN/ 208/ 2012/ver.2 with latest amendments/revision, if any from RDSO approved sources. Tool kit shall be supplied free of cost with each set of ELB as per Para 10.2 of RDSO specification. Note: Required nos. of limit switches are to be provided including 2 nos. of 0-50 limit switch for redundancy.) (Inspection by RDSO. However, items not covered under RDSO will be inspected by consignee).

13

358517

4660729.58

... More
Installation, wiring, testing and commissioning electrically operated lifting barrier complete with casting of concrete foundation for pedestal and boom rest post. This includes cabling, 2 power supply connection wiring and all the associated outdoor activities. All materials except signalling cable shall be supplied by contractor as per technical specification & scope of work mentioned in tender document. Foundation drawings of pedestal & boom rest post shall be got approved by Railway Engineer. Installation, wiring, testing & commissioning shall be done in presence of technical representative by OEM of ELB.

13

36184

470394.6

... More
Supply, fixing, wiring, testing & commissioning of Electronic Hooter Unit (24V DC/110V AC operated) of approved design/make along with 2 nos. of outdoor speaker of 15W 8 ohms to warn road users during operation gate. (Inspection by Consignee)

23

3064

70477.52

... More
Installation, testing & commissioning of Sliding Boom Barriers with posts & E type of 4 locks as per standard drawing of Railway including casting of concrete foundations for boom supporting posts & boom lock post. (Note: Sliding Boom Barriers with required accessories will be supplied by Railway. All types of nut-bolts to be used for installation of sliding boom barriers will be supplied by contractor.)

13

50658

658564.66

... More
Supply, installation, wiring, testing & commissioning of domino type LC gate signal control panel suitable for ABS territory as per drawing approved by Railway Engineer and as per technical specification & scope of work mentioned in tender document. (Inspection by Consignee.)

21

31498

661459.26

... More
Supply of Electrical KeyTransmiter (EKT) RotaryType as per RDSO Specn.No. IRS:S- 6 21/01 & RDSODrg. No. SA-22601(Alt.4)or latest with the keys andwards as per approvedSignal Interlocking Plan(SIP) or as per instructionsgiven by site Engineer incharge. InspectionAuthority :- RDSO Inspection

21

5054

106139.67

... More
Supply of Key Lock Checking Relay (KLCR) working on 24V DC, AC Immunized withdifferent ward combinations and contact configuration 4F/4B with 2 extra ward plates and with case, RDSO spec no. RDSO/SPN/219/2016 ver 1.0 or latest, confirming to IRS S-23, S-34 & S@45<44@ IRS S:46. Inspection authority:- For bare relay -RDSO, for key lock housing- consignee

45

10221

459973.35

... More
Supply of Colour Light Signal Post, Tubular Mild Steel, 4.5 m length, 140 mm Dia, as per 1 RDSO Spec. No. IRS: S-6/81 with latest amendments/ revision and Supply of cast iron Main signal surface base (As per RDSO Drg. No. 2011/M with latest amendments/ revision), with CLS ladder assembly suitable for colour light signal of 4.5 m long, as per RDSO drg. No. SA 23153 and complete assembly of signal front & back staging for CLS unit. (Inspection by RITES.)

100

25924

2592449

... More
supply of Offset Bracket for colour light signal Main unit, with fixing U clamps & nuts etc., as per RDSO Drg. No. SA 23080 (Adv.) with latest amendments. (Inspection by RITES.)

20

1237

24753.2

... More
Supply of Junction route indicator unit 1 way, made of FRP (without lenses & holder) as per Drg No. SA 23401-06 (Adv) (as applicable) suitable for LED Signal Lighting unit and as per RDSO Spec. IRS:S-66/84 Amd.-1 or latest and RDSO/SPN/194/2006 (Rev.2) or latest.(Inspection by RITES.)

20

45600

912015.4

... More
Supply of Four Aspect Non Metallic (FRP) colour light signal housing multi unit type for 4 Railway Signalling suitable for RE area, complete without lenses, lamps and signal transformer as per RDSO Drg No. SA 23001 A/M (Adv) and as per RDSO Spec No.RDSO/SPN/194/2006 (Rev 2.0) or latest and FRP material as per RDSO Spec No. RDSO/SPN/151/1997 or latest.(Inspection by RITES.)

142

43318

6151197.18

... More
Supply of hand cuff lock with key of approved type & standard make for locking signal unit door. (Inspection by Consignee)

540

168

91152

... More
Supply of Apparatus Cases (full location box) as per RDSO Drawing No. RDSO/S-11500 6 or latest with miniature E type locks & keys. The key & handle shall be supplied at the rate of one set per four Apparatus Case. miniature E type locks are to be fitted on both front & back doors of location box.(Inspection by RITES.)

250

28207

7051985

... More
Supply of Phenolic laminated Sheet, resin bonded, grade P3 in standard size of 1220 X 1220 x 10 mm as per specification No IS 2036 of 1995 or latest. Test report of manufacture to be supplied. (Inspection by RITES.)

250

5901

1475417.5

... More
Supply of Fuse Block made of PBT/Polycarbonate material as per RDSO Specification No. IRS:S-78/2006 & RDSO Drg.no SA-23748 or latest from RDSO approved sources.(Inspection by RDSO.)

1800

122

220554

... More
Supply of Non-deteriorating type low voltage cartridge fuse rated current 1/2/4 Amp, round head type as per RDSO spec no. IRS.S 78/2006 with latest amendments/ revision from RDSO approved sources. (Inspection by RDSO.)

900

97

87804

... More
Supply of Non-deteriorating type low voltage cylindrical head cartridge electric fuse 6/10 amp as per RDSO specification No. IRS/S/78/2006 with latest amendments/ revision from RDSO approved sources. (Inspection by RDSO.)

1000

103

103410

... More
Supply of ARA Terminal Block made of PBT - 6 Way as per RDSO Spec. No. IRS: S75/2006 (Rev. 2) or latest & Drg. No.SA-23756 (Alt-4) or latest from RDSO approved sources.

3000

271

815460

... More
Supply of PVC Insulated, Indoor cable, single core, 1.0 mm, flexible, as per RDSO Specification No. IRS-S-76/89 (Amndt. -3) or latest. Coil should be of different colours, each coil in 100 m length. (Inspection by RDSO.)

6000

7

43440

... More
Supply of 1 x 6 Sq mm (Red/Black/Green) multi strand copper power wire, 85 conductor 13 each dia 0.30 +/- 0.01 with insulation thickness of 0.8 mm and nominal conductor resistance of 3.3 ohms/km as per RDSO Specn.No.IRS:S-76/89 (Amnd.3) or latest and IS: 2465/1984 and IS:694:2010 or latest. Colour of the wire will be specified by the Engineer incharge.(Inspection by RDSO.)

8000

49

393440

... More
Supply of 1 x 10 Sq mm (Red/Black/Green) multi strand copper power wire, 101 14 conductor each dia 0.45 +/- 0.01 with insulation thickness of 1.2 mm and nominal conductor resistance of 1.127 ohms/km as per RDSO Specn.No.IRS:S-76/89(Amnd.3) or latest and IS: 2465/1984 and IS:694:2010 or latest. Colour of the wire will be specified by the Engineer incharge.(Inspection by RDSO.)

5000

128

643800

... More
Supply of 1 x 16 Sq mm (Red/Black/Green) multi strand copper power wire, 101 15 conductor each dia 0.45 +/- 0.01 with insulation thickness of 1.2 mm and nominal conductor resistance of 1.127 ohms/km as per RDSO Specn.No.IRS:S-76/89(Amnd.3) or latest & and IS: 2465/1984 and IS:694:2010 or latest. Colour of the wire which is required will be specified by the Engineer incharge. (Inspection by RDSO.)

4500

151

681795

... More
Supply of 16/0.2 mm (0.5 sq mm) PVC insulated, multi strand single core, tinned copper conductor as per RDSO Specification No. IRS: S-76/89 (Ammdet-3) or latest from RDSO approved sources. Each coil shall be of 100 meters.(Inspection by RDSO.)

250000

11

2790000

... More
Supply of Q-Series Universal type QECX-61 AC LED lamp proving relay (ECR) of 4F-4B 17 contacts with plug board (base plate), connectors, retaining clip etc. and conforming to BRS:941A, STS/E/RELAYS/AC LED SIGNAL/09-2002, Amndt.1 or latest and RDSO Specification No. IRS:S@45"45@68 & Amendment 6, S-23-88 & Amendment 1 or latest as applicable from RDSO approved sources.(Inspection by RDSO)

600

6988

4193298

... More
Supply of Q-Series Neutral Line Relay, non-AC immunized (QN1 type), 8F/8B, 24V or 18 50V DC complete with plug board (base plate), connectors, retaining clip etc. and conforming to BRS:930 and Specification No. IRS:S@45"45@68 & Amendment 6, S-23-88 & Amendment 1, S@45<45@78 & Amendment 1 or latest as applicable from RDSO approved sources. (Inspection by RDSO.)

1000

4169

4169490

... More
Supply of Q-Series Line Relay, AC immunized (QNA1 type), 8F/8/B, 24V or 50V DC 19 complete with plug board (base plate), connectors, retaining clip etc. and conforming to BRS:931 and Specification No. IRS:S@45"45@68 & Amendment 6, S-23-88 & Amendment 1, S@45<45@78 & Amendment 1 or latest as applicable from RDSO approved sources. (Inspection by RDSO.)

1000

4569

4569530

... More
Supply of main LED signal lamps of Green aspect with inbuilt current regulator as per RDSO Specification No. RDSO/SPN/199/2010 Revision 1.1 or latest retrofittable in existing CLS housing & compatible with AC LED ECR from RDSO approved sources. (Inspection by RDSO.)

142

10142

1440293.22

... More
Supply of main LED signal lamps of Red aspect with inbuilt current regulator as per RDSO Specification No. RDSO/SPN/199/2010 Revision 1.1 or latest retrofittable in existing CLS housing & compatible with AC LED ECR from RDSO approved sources. (Inspection by RDSO.)

142

8938

1269252.8

... More
Supply of main LED signal lamps of Yellow aspect with inbuilt current regulator as per RDSO Specification No. RDSO/SPN/199/2010 Revision 1.1 or latest retrofittable in existing CLS housing & compatible with AC LED ECR from RDSO approved sources. (Inspection by RDSO.)

284

8943

2539837.56

... More
Supply of Route LED Signal lighting unit 110V AC retrofittable in existing CLS housing and compatible with AC LED ECR as per RDSO Specification No. RDSO/SPN/153/2011 revision 4.1 or latest. (Inspection by RDSO.)

100

6178

617865

... More
Supply of "A" Marker LED Signal Lighting Unit retrofittable in existing CLS housing and compatible with AC LED ECR as per RDSO Specification No. RDSO/SPN/153/2011 revision 4.1 or latest. (Inspection by Consignee.)

120

6133

735979.2

... More
Supply of "AG" Marker LED Signal Lighting Unit retrofittable in existing CLS housing and compatible with AC LED ECR as per RDSO Specification No. RDSO/SPN/153/2011 revision 4.1 or latest. (Inspection by Consignee.)

55

6133

337323.8

... More
Supply of Double Walled Corrugated (DWC) pipe with associated collars etc. as per RDSO Specification No. RDSO/SPN/204/2011 Ver. 1.1 & Amendment 1 or latest, anti-rodent & anti- oxidant and non-flame propagating type of size 175 mm inner dia and 200mm outer dia in 6 metre 26 length suitable for taking underground communication/ signalling cables. One coupler with suitable rubber O-ring for jointing shall be supplied with each 6 mtrs. length. (Note: DWC pipe shall be marked at every ONE meter length in such a way that manufacturer's name & year of manufacturing can be easily identified. (Inspection by RITES)

500

429

214710

... More
Supply of Double Walled Corrugated (DWC) pipe with associated collars etc. as per RDSO Specification No. RDSO/SPN/204/2011 Ver. 1.1 & Amendment 1 or latest, anti-rodent & anti- 27 oxidant and non-flame propagating type of size 103.5 mm inner dia and 120 mm outer dia in 6 metre length suitable for taking underground communication/ signalling cables. One coupler with suitable rubber O-ring for jointing shall be supplied with each 6 mtrs. length. (Note: DWC pipe shall be marked at every ONE meter length in such a way that manufacturer's name & year of manufacturing can be easily identified.(Inspection by RITES.)

500

307

153750

... More
Supply of Double Walled Corrugated (DWC) pipe with associated collars etc. as per RDSO Specification No. RDSO/SPN/204/2011 Ver. 1.1 & Amendment 1 or latest, anti-rodent & anti- 28 oxidant and non-flame propagating type of size 103.5 mm inner dia and 120 mm outer dia in 6 metre length suitable for taking underground communication/ signalling cables. One coupler with suitable rubber O-ring for jointing shall be supplied with each 6 mtrs. length. (Note: DWC pipe shall be marked at every ONE meter length in such a way that manufacturer's name & year of manufacturing can be easily identified.(Inspection by RITES.)

200

1016

203366

... More
Supply of HDPE duct of 40/33 mm in Drum length of 500/1000 meter length as per RDSO Specification RDSO/SPN/TC/ 45/ 2013 revision 2.0 (Amdt. 2.0) or latest either from RDSO or TEC approved firms along with test report of manufacturer.(Inspection by RITES.)

230

78753

18113298.1

... More
Supply of 4 conductor disconnect terminal block with screwing cage/ clamp type, sliding switch disconnect as per RDSO Specification No. RDSO/SPN/189/2004 Ver 3.0 or latest for each conductor size upto 2.5 sqmm from RDSO approved sources. (Inspection by RITES.)

80000

99

7967200

... More
Supply of end and intermediate plate 2.5 mm/0.098 in thick as per RDSO Specification No. RDSO/SPN/189/2004 Ver 3.0 or latest. Make Wago or Phoenix make or similar. (Inspection by RITES.)

80000

21

1755200

... More
Supply of screwless end stop 10 mm/0.394 in wide carrier wide rail din 35 of Wago or Phoenix make or similar.(Inspection by RITES.)

2000

21

43820

... More
Supply of steel carrier rail of size 35x7.5 mm of Wago or Phoenix make or similar. (Inspection by RITES.)

1000

178

178290

... More
Supply of Thermo Shrink Jointing Kit (RTSF4) as per RDSO Specification No. IRS TC-77- 34 2012 (Rev.3) or latest suitable for 6 quad jelly filled cables for straight through/ derivation joints including supply of all the accessories from RDSO/TEC approved sources & along with test report of manufacturer. (Inspection by Consignee)

200

2166

433240

... More
Supply of of V.F.Transformer (2T/3T) 1120:470 Ohms as per RDSO Specification No. IRS TC-76-2021 (Ver.1) (Cylindrical Type) or latest suitable for 6 quad jelly filled cables for derivation and Termination of underground Telecom Cable Circuit. (Inspection by Consignee)

75

920

69018

... More
Supply of Fibre DistributionManagement system (FDMS)/LIU for 48 Fiber as per drawing 36 No:RDSO/TCDO170(a) complete with allaccessories as per TEC Spec.GR/FDM/01/02 April'2007 or latest.This include supply of installation accessories as per technical specification.(Inspection by Consignee)

84

7911

664524

... More
Supply of 48 Fiber OFC Joint Closure similar to Specification No.RDSO/SPN/TC/68/2014 Rev 1.0 or latest.(Inspection by Consignee)

110

1738

191239.4

... More
Supply of Rodometer [Analog] Spec:Mechanical 5 digits counter, ABSPlastic wheel with rubber tyre,measure Forward & Backward,Telescopic handle, Precision measuringwheel. Make/Brand: Stanley or Boschor JCB or Freeman or Equivalent.(Inspection by Consignee)

3

3662

10986

... More
Supply of Auto single fiber fusion splicer machine with all relatedaccessories and power supply backuparrangement. Make: Fuzikura orbetter.(Inspection by Consignee)

1

217384

217384

... More
Supply of STP CAT-6 Cable (ShieldedTwisted Pair) STP compliant with latest EIA/TIA-568- B2-1.(Inspection by Consignee)

600

33

19800

... More
Supply of Optical Time DomainReflectometer (OTDR) as per TEC SpecNo. : TEC/GR/TX/OTD001/05/SEP-19or latest. Make- Yokogawa/ Fuzikura/Sumimoto.(Inspection by Consignee)

-

-

41

... More
Supply of OFC patch card with SC/PC-SC/PC connectors of 2/5/10/15 meter long of standard make.(Suitable for interconnect S&T equipments of ABS work) (Inspection by Consignee)

600

531

319002

... More
Supply of Office Almirah of size 914.4 (W) x 1981.2 (H) x 533.4 (D) mm as per model No. KD MNOR with metal top of Godrej make or similar. (Inspection by Consignee)

12

35487

425854.44

... More
Supply of Table of size 1370 (W)x740(H)x690 (D) mm as per Model No. T-9 of Godrej Make or similar. (Inspection by Consignee.)

12

17620

211443.48

... More
Supply of Chair of model OXBO with High Back of Godrej make or similar. (Inspection by Consignee)

12

16963

203565.6

... More
Supply of Chair Superior Quality with Arm and Cane seated of size 57(D)x58(W)x88(H) and seat height of 45 mm of model no. classic CH-7 of Godrej make or similar. (Inspection by Consignee)

48

3922

188298.72

... More
Supply of Micro Processor based Data Logger System with 512 digital inputs and 32 analog inputs with protocol converter as per RDSO Spec. No. IRS (S) 99/2006 (Amnd. 3) or latest. It includes supply of all the items required for complete indoor relay room wiring from data logger to 47 relay rack tag blocks, drawing/extension of power supply upto Data Logger. It includes relay room door lock checking arrangement, commercial power supply monitoring arrangement & monitoring of DG sets, ELD, IPS, UFSBI, ELD, MSDAC etc., interlinking and networking of Data logger, interfacing with EI. Note: Total numbers of relays and other signalling functions/gears required to be wired as per list circulated vide RDSO Letter No.STS/E/Data logger dtd.12.09.2011 or latest guidelines.(Inspection by RDSO)

12

332088

3985066.56

... More
Supply of T-Networking Modem for connecting RTU with existing Data logger/RTU as per RDSO Spec. No. IRS (S) 99/2006 (Amdt. 3) or latest.(Inspection by Consignee)

12

23544

282530.16

... More
Supply of Maintenance Console along with Inkjet Printer, 1 KVA UPS of minimum 30 49 minutes capacity and one set of table & chair for Datalogger/RTU for online tracking & monitoring of data of station/auto relay huts as per Technical Specifications mentioned in Tender Documents. (Inspection by Consignee on OEM test certificate.)

14

101321

1418497.5

... More
Supply of Optical Power Meter having resolution of 0.1 db & measuring range +3 dbm to -60 dbm as per TEC specification No. GR/OPM-01/03 Feb 05 or latest.(Inspection by Consignee)

1

18191

18191.2

... More
Supply of Insulation Resistance Tester 500V DC, 100 Mega ohm, hand generator type. Make: Meco/Motwane/Waco or similar.(Inspection by Consignee)

2

18281

36563

... More
Supply of Insulation Resistance Tester 100V DC, 100 Mega ohm, hand generator type. Make: Meco/Motwane/Waco or similar.(Inspection by Consignee)

2

16088

32177.52

... More
Supply of Digital Clamp Earth Tester/Meter with storage facility of Model DET20 of Motwane make or Meco or Fluke or better.(Inspection by Consignee)

1

117847

117847.33

... More
Supply of Digital Multimeter of model No. Fluke 287 of Fluke make or better.(Inspection by Consignee)

2

76480

152960.54

... More
Supply of Digital AC/DC Leakage Current Clamp on Meter of Model CL360 of Yokogawa or DCM 39A of Fluke make or similar model of Motwane make or better.(Inspection by Consignee)

4

59741

238964

... More
Supply of Magneto Telephone Handle Type as per RDSO Spec IRS-TC-79/2000 or latest. (Inspection by Consignee)

50

3549

177469.5

... More
Supply of Tag blocks 120 way with Polycarbonate cover as per IRS: S-77/2006 (Rev. 1) or latest, as per drawing no. SA-24751, SA-24752, SA-24753 respectively. (Inspection by Consignee)

90

1450

130558.5

... More
Supply of Ethernet to OFC & OFC to Ethernet Media Converters of MOXA/ATOP/Phoenix make or similar as per Technical Specification mentioned in Tender Document.(Inspection by Consignee)

-

-

58

... More
Supply of Networking Switch of minimum Four Ethernet Ports & Two SFP Ports of MOXA/ ATOP/ ADVANTECH make or similar as per Technical Specification mentioned in Tender Document. (Inspection by Consignee)

23

49982

1149598.88

... More
Supply of PVC Indoor Cable 1x60x0.6mm dia Colour coding of insulation of inner core shall be in six colour viz Blue, Red, Grey,Green, Brown & Black conforming to IRS 76/89 (Amd. 3) or latest from RDSO approved sources.(Inspection by RDSO)

3000

308

924810

... More
Supply of PVC Indoor Cable 1x 40x0.6mm dia. Colour coding of insulation of inner core shall be in eight colour viz Blue, Red, Grey, Green, Brown, Black, Yellow & White conforming to IRS 76/89 (Amd. 3) or latest from RDSO approved sources.(Inspection by RDSO)

2000

202

405440

... More
Supply of Calling ON Signal Unit with out lenses and lamps and with offset bracket 3.5" dia as per RDSO drawing No. SA-24351(Adv) alter 1 or latest . (Inspection by RITES)

230

4705

1082267.3

... More
Supply of portable Work Station Note Book for doing programming & data analysis in the field as per Technical Specifications mentioned in Tender Documents of make-HP/DELL or superior. (Inspection by Consignee on OEM test certificate.)

2

87842

175685

... More
Supply of Laserjet Printer for taking print out of various field data for analysis as per Technical Specifications mentioned in Tender Documents of make- HP/Canon/Epson or superior. (Inspection by Consignee on OEM test certificate.)

2

29369

58738.66

... More
Supply of Micro Processor based Data Logger System with 512 digital inputs and 32 analog inputs with protocol converter as per RDSO Spec. No. IRS (S) 99/2006 (Amnd. 3) or latest. It includes supply of all the items required for complete indoor relay room wiring from data logger to 65 relay rack tag blocks, drawing/extension of power supply up to Data Logger. It includes relay room door lock checking arrangement, commercial power supply monitoring arrangement & monitoring of DG sets, ELD, IPS, UFSBI, ELD, MSDAC etc., interlinking and networking of Data logger, interfacing with EI. Note: Total numbers of relays and other signalling functions/gears required to be wired as per list circulated vide RDSO Letter No. STS/E/Data logger dtd.12.09.2011 or latest guidelines.Inspection by RDSO)

3

252732

758197.02

... More
Supply & installation of Relay Rack Assembly complete with scaffolding, fixtures, wall supports and accessories including MS Bars for fixing of relay plug board, string rods, fuse strips with 1 bracket, 11 Way Bus Bars with cover and mounting brackets, runway for cable/wires, frame, base assembly etc. with all required accessories suitable for Q-Series Relays & as per drawing & extant practices on NE Railway. Relay rack shall be corrosive resistant and power coated. (Inspection by Consignee)

19

41295

784617.54

... More
Supply and installation of Cable Termination (CT) rack as per drawing of NE Railway, complete along with fitting arrangements, wall supports, scaffolding and suitable grouting 2 arrangements and also with arrangement for fixing Disconnect type terminal blocks/ ARA terminals. The CT rack shall be covered with Phenolic Laminated Sheet of minimum 10 mm thickness for fixing of Disconnect type terminal blocks/ ARA terminals. Cable termination rack shall be corrosive resistant and power coated. Note: Supply of Disconnect type terminal blocks/ ARA terminals not covered under this item. (Inspection by Consignee)

19

33235

631470.32

... More
Fabrication, supply and installation of Power Supply Distribution Rack made of MS Angle of Size 40mm x 40mm x 6mm (similar to Cable Termination rack) as per drawing of NE Railway, 3 complete along with fitting arrangements, wall supports, scaffolding and suitable grouting arrangements in IPS Room. The Power Supply Distribution rack shall be covered with Phenolic Laminated Sheet of minimum 10 mm thickness for fixing of Fuse terminal blocks/ ARA terminals. This includes supply & fixing of standard size ladder suitable for indoor cable made of MS angle of size 25mm x 25mm x 5mm from Battery Room to IPS Room and from IPS Room to Relay room for taking power cables. Power Supply Distribution Rack & ladder rack shall be corrosive resistant and power coated. This also includes fixing of required nos. Fuse Terminal Blocks & ARA Terminals on laminated sheet as per power supply distribution diagram and laying of required nos. of power cables from Power Supply Distribution Rack to Relay Room & Battery Room of various supply in ring protection & terminating with help of crimped copper lugs of suitable sizes duly supported on ladder with proper lacing & dressing. Various sizes of lugs for terminating power cables are to be supplied by contractor. Note: Power cables, fuse terminal blocks & ARA terminals not covered under this item. (Inspection by Consignee)

12

24711

296543.76

... More
Supply, installation, wiring, testing commissioning of Earth Leakage Detector (ELD) of 8 4 channel, voltage of 110 Volt/60 V/24V/12V in AC/DC as per RDSO Spec. No. RDSO/SPN/256/2002 or latest. This includes supply of fuse terminal strip for incoming supply wires. Installation to be done on 19-inch sub-rack along with insulation resistance meter, indication & buzzer.(ELD to be inspected by RDSO.)

12

165283

1983399.48

... More
Supply, installation, wiring, testing & commissioning of Microcontroller based Quad 5 cable conductor Earth Resistance sensing unit for 24 nos. of conductors having NO & NC contact for remote monitoring as per Technical Specification mentioned in Tender Document. (Inspection by Consignee)

12

87189

1046277.36

... More
Supply, Installation, Wiring, Testing & Commissioning of Networkable type Microprocessor based Addressable, Automatic Fire Detection & Alarm System (AFDAS) consisting of Control Panel & other accessories as per RDSO spec. No. RDSO/SPN/217/2021 Ver 3 or latest from RDSO approved sources. The number of detector and devices per loop should be up to 159. The AFDAS shall include a backlit min 360-character liquid crystal display, individual, color coded system status LEDs, 2 Nos sounder circuit for audiovisual devices and alphanumeric keypad for the field 6 programming and control of the fire alarm system. The AFDAS shall have provision for GSM based dialer to send automated SMS to at least 5 pre-selected mobile numbers. The AFDAS shall also have provision to network on LAN & communicate to the graphical application on TCP/IP. The AFDAS shall have built in power supply, battery charger and battery backup for 24 hours normal operation. The panel shall be UL/LPCB/VDS approved and comply to NFPA-72/EN54 requirement. This also consists of supply execution of following items to make complete system functional as per RDSO specification. All required accessories to make the AFDAS fully functional are to be supplied by contractor. (Inspection of supply portion by RDSO)

12

105107

1261289.64

... More
Supply, Installation, Wiring, Testing & Commissioning Analogue Addressable Multi sensor Detector with inbuilt isolator/ isolator base having photo, fixed heat and ROR heat detection 7 feature and 360-degree view LED and minimum 5 level of sensitivity setting, complying to RDSO/SPN/217/2021 Ver 3 or latest. Operating temperature -10 to 60 degree Celsius, humidity up to 85%, as per latest UL/LPHB/VDS approved/listed.suitable for Automatic Fire Detection & Alarm System (AFDAS). (Inspection of supply portion by RDSO.) (8 nos. per Auto Relay Hut)

96

3284

315278.4

... More
Supply, Installation, Wiring, Testing & Commissioning of Analogue Addressable type & 8 Resettable Manual Call Point (Red colour) with back box & with inbuilt fault isolator or alternate arrangement which shall isolate the MCP in case of short circuit. The MCP should have visual indication for its operation. Approval/listed - UL/ LPCB/ VDS and shall comply to RDSO/SPN/217/2021 Ver 3. (Inspection of supply portion by RDSO.)

12

4510

54127.68

... More
Supply, Installation, Wiring, Testing & Commissioning Isolator Modules as per RDSO Specification No. RDSO/SPN/217/2021 Ver 3 or latest, suitable for Automtic fire detection & Alarm system(AFDAS).(Inspection of supply portion by RDSO)

24

7004

168103.68

... More
Supply, Installation, Wiring, Testing & Commissioning of Control Module with backbox & 10 inbuilt fault isolator to address sounder cum strobe as per RDSO Specification No. RDSO/SPN/217/2021 Ver 3 or latest.suitable for Automtic fire detection & Alarm system(AFDAS).(Inspection of supply portion by RDSO)

12

7085

85022.28

... More
Supply, fixing, laying of Fire survival integrity cable 2x1.5 sq.mm un-armoured as per RDSO specification No. RDSO/SPN/217/2021, Ver.3 or latest. This work involves supply, fixing & laying of cables inside PVC pipe/capping casing duly connecting all the detectors/ sensors, sensing cable, manual call points, control panel. This also include supply & fixing of PVC pipe/ casing capping of 25mm size of IS standards on wall/roof including supply of all accessories like bents, screw, nails etc. as directed by the Railway Site Engineer. (Inspection of supply portion by RDSO)

1000

204

204380

... More
Supply, Installation, Wiring, Testing & Commissioning of Audio-Visual Alarm (Electronic 12 Hooter & Strobe) with back box controlled through addressable control panel. It shall be preferably flashing type of Red/White colour. The sound level shall be preferably adjustable type up to 90dB at a distance of 1 meter and shall be complying to RDSO/SPN/217/2021 Ver 3. (Inspection of supply portion by RDSO.)

12

7667

92014.8

... More
Supply, installation & commissioning of CO2 Fire Extinguisher 4.5 Kg capacity confirming to IS 15685 with ISI mark provided with all fittings & accessories. Make: Safex, Bharat or similar.)(Inspection of supply portion by Consignee.)

19

5055

96057.73

... More
Supply, installation & fixing of FDMS as per GR No.G/FDM-01/02 April-2007 of TEC or 14 latest. it includes the supply of Splicing of 19 inch 42U rack with mounting arrangement . it will also include all installation material,splicing,termination ,testing of all 2x48 fibers. (Inspection of supply portion by RITES)

38

86991

3305672.06

... More
Installation and commissioning of Fibre Distribution Management system (FDMS) for 48 Fiber complete with all accessories with patch cord & pigtail as per TEC Spec. with latest amendment. This include supply of installation accessories as per technical specification.

72

6868

494496

... More
Supply & installation Ring Earth for EI system, consisting of 06 (six) number of maintenance free earths, which includes supply of all components of earthing & bonding system like earth electrode, earth enhancement materials, earth pit, equipotential earth bus bar, connecting cables and tape/strips and other associated accessories in accordance with RDSO Spec. No. 16 RDSO/SPN/197 Ver.1.0 or latest and provision of earth pits to be connected in a ring to achieve less than 01(One) ohm earth resistance for connecting EI equipments, relay racks, panel , power equipments, IPS as per RDSO TAN no. STS/E/TAN/3006 dated 02.11.2012 or latest. Diagram of ring earth should be supplied to Railway for approval before execution. All related materials as recommended by RDSO in Spec. No. RDSO/SPN/197 Ver. 1.0 or latest, will be supplied by the contractor. (Inspection of supply portion by RDSO)

12

337920

4055044.44

... More
Fabrication, Supply and fixing of Retro reflective Signal Number Plates fabricated as per Drawing No. NER/TYP/MAIN SIGNAL NUMBER Plate/2022 of NER. All fixing accessories including clamps, nut, bolts etc. are to be supplied by contractor.(Inspection by Consignee)

137

780

106949.05

... More
Supply and installation of Earth Electrode as per standard practices and as per SEM Drawing No.19-D6 . It includes supply of GI pipe of 3m length. It includes connecting the earth electrode to the equipments which are required to be earthed including digging of earth pit 3 meter 18 deep and fixing earth electrode pipe, casting of cement concrete enclosure with cover. It includes supply, installation & fixing of 7 strand GI wires as earth lead wires, supported on MS flat size 5mm x 40 mm, soldering and nut bolt both, one end of both earth lead wire and MS flat to earth electrode and other end to Location boxes, block equipments, power equipments, cable sheath, signals etc. as per site requirement and as per instructions given by engineer incharge.(Earth Electrode Inspected by RITES)

600

3616

2170128

... More
Fabrication, supply and fixing of MS-C channel of minimum size 10mmx50mmx1200mm 19 with suitable clamps as per drawing No. S&T/RE/78/2/76 and fitting to GI pipes with suitable clamps on girder bridges for sturdy fixing with girders. MS-C channels are to be fabricated as per site requirement.(Inspection by Consignee)

50

700

35019

... More
Supply, installation & commissioning of active lightening arrester of class-A for building protection-as per standard NFC-17-102 or latest. It shall work on early streamer emission principle and shall be made of stainless steel with an operating time of 60 microsecond or less. A non-resettable 20 type counter shall also be supplied to count the number of lightening occurrences. The device shall be installed on top of the building on a GI mast and shall be connected to the earth pit through a copper tape of 25mm x 2mm or better. The copper tape shall not touch the building throughout and shall be connected to the earth electrode by exothermic welding. Class-A arrestor should be fixed at least 3 meter above all the metallic structure including VHF antenna. Material shall be procured from RDSO recommended sources & to be supplied along with manufacturer test report.(Inspection RITES.)

12

117020

1404245.76

... More
Supply & installation Maintenance Free Earth as per RDSO Spec. No. RDSO/SPN/197 Ver. 1.0 or latest to achieve a resistance less than 1 ohm consisting of supply of following basic materials: (a) Copper bonded steel electrode of minimum 3.0 m long, minimum 17.0 mm dia with copper bonding thickness of minimum 250 microns and UL listed and marked = 1 no. (b) Earth enhancement material supplied in sealed bags of minimum 10 kg = 3 nos. (c) Copper strip of 150x25x6 mm, to terminate earth rod = 1 no. (d) Copper strip of 300x25x6 mm (MEEB) = 1 no. (e) Copper strip of 150x25x6mm (SEEB) =1 no. (ii) Supply of 35 sq. mm multi strand single core PVC 21 insulated copper cable as per IS: 694 for connecting main earth electrode to MEEB in the equipment room in duplicate. (minimum 10 meter) (iii) Supply of 16 sq. mm multi strand single core PVC insulated copper cable as per IS: 694 for c onnecting MEEB to SEEB and SPD to MEEB (minimum 10 meter) (iv) Supply of 10 sq. mm multi strand single core PVC insulated copper cable as per IS: 694 for connecting various equipments to SEEB. (v) Supply of copper lug sleeve for 3/16 cable. Installation of Maintenance Free Earth should include following: (i) Digging the earth to the required depth. (ii) Insertion of electrode. (iii) Filling of earth enhancing compound (Approx.30 Kg) (iv) Provision of exothermic weld connections to copper tape of 25 mm x 6 mm x 150 mm to the earth electrodes. All material tools and features required for weld will be arranged by contractor. (v) This also includes CC cover 1.5 ft x 1.5 ft. 1 ft wall thickness 2 inch with cover of 3 inch thickness. (Inspection of supply portion by RDSO.)

12

39651

475821.12

... More
Fabrication, Supply and Fixing of Cable Route Marker made with reinforced concrete in 22 the ratio 1:3:6, engraved with "NER-S&T" on the top portion on both the side duly painted as per RDSO Drg. No SDO/cable laying/020. Cable Route Markers are to be grouted at distance of approximately 100 meter on the cable route.(Inspection By Consignee)

1200

449

539628

... More
Supply, Installation, Wiring, Testing & Commissioning of Modular Power Supply Arrangement for VDU (42" - 85") and Industrial PC (Embedded PC) with Input and Output Redundancy Arrangement and Hot Pluggable Modules according to RDSO letter No. RDSO-SIG0EI(GEN)/1/2020 23 dated 11/07/2022 of Gallant make or similar and consisting of followings: 1. Input O-Ring Diode Module with Potential Free-1 No. contacts (PFC) for two 110VDC Sources from IPS and Single 110VDC bus. 2. Isolated Inverters (Master/Slave) -2 Nos. Input: 110VDC, Output: 120VAC/220VAC 500VA 3. Isolated DC- DC Converters-2 Nos. Input:110VDC, Output:24VDC/10A. 4. 3U SS Rack with back Panel Mother Board/ Front Panel Power Connectors Inverter Auto Change Over Switch and all required over Switch and all required protection circuits as per RDSO specification. (Inspection by RITES.)

24

237390

5697362.88

... More
Supply installation,wireing,testing & commissioning of Two wire Talk-Back 24 System(Signal Post Telephone) consisting of one master and one slave of standad make to work in 25KV RE area(Operating on 24v/110V) up to distance of 10Kms. On Quad cable without any interference/noise.(Inspection by Consignee)

12

7680

92163.96

... More
Supply, fabrication and fixing of retro-reflective marker/boards/plates of 'AG' marker- 25 Non illuminated as per RDSO Drg. No. SA-23459@45<40@Adv) and "A' marker-Non-Illuminated as per RDSO Drg. No. SA-23461(Adv) and as per NER Drawing No. NER/TYP/MAIN SIGNAL NUMBER Plate/2022. All fixing accessories including clamps, nut, bolts etc. are to be supplied by contractor. (Inspection by Consignee.)

60

930

55827

... More
Supply of Cable/Pipe Route Locator as per technical specification (Make & Modal no.-3M Dynatel Integrated Cable Route Tracer and Marker Locator 2273 M or Similar/Superier) (Inspection by Consignee)

1

459436

459436.46

... More
Casting, concreting and curing of foundation for Main Signal Post in the ratio of 1:3:6 as per NER Drg. No. CSTE/CON/2000(SK)1, using standard size of foundation/galvanized anchor bolts 1 complete, required for erection of colour light signal post. Anchor bolts complete should comply with the RDSO drg. no. SA 116 A/M. Item includes excavation, ramming of CC using vibrator, curing and plastering with 1:4 cement-sand mixture (aggregate will not exceed 3.8 cm). Aggregate, cement, sand and holding down bolts will be supplied by contractor. Any machines & tools, if required for execution of this item, will be arranged/provided by contractor.

100

17947

1794766

... More
Erection of CLS Post with base and signal unit on top or on Offset Bracket including erection of auxiliary signals like 'A' marker, Calling On, shunt signal if any. It includes fixing of all LEDs and wiring of complete signal including route and auxilliary signals, if any. It includes fixing of front and back staging, ladder and guards, signal name plates / boards, with contractor's own brackets and fixing materials. The work shall be done as per instructions of Rly engineer at site. It also includes provision & fixing of maintenance platform as per design given by Engineer -In-Charge at site. The Item includes cutting of Signal post if required by Site In charge.

-

-

2

... More
Fixing of Junction type Route Indicator on top of signal post and complete wiring, 1- Way/ 2-Way/ 3-Way/ 4-Way/ 5-Way/ 6- way/ Theater type.

20

1477

29553.4

... More
Excavation, casting, curing of foundation and installation & erection of Apparatus case Full (App. Case as per RDSO Drg. No. RDSO/S-11500 or latest) with contractor's own frame, anchor 4 bolts & nuts, cement and other material in the ratio 1:3:6 s foundation drawing of Railway. 'E' type lock to be supplied and installed with App. case. This includes filling of location foundations with river bed sand and plastering on top with a mixture of 1:4 of cement and sand, ramming of loose soil around foundation and disposal of loose dugged soil from site. It covers fixing of lamp holder, switch and lamp etc. in Apparatus Case.

284

16307

4631415.2

... More
Fabrication and fixing of phenolic laminated sheet of grade P3, minimum 10 mm thickness, as per Apparatus case diagram/plan, in full size location box (full size apparatus case) by 5 providing all fixtures like ARA/Disconnect terminals, fuse blocks, fuses, relays on square bars etc. including fixing of PVC coated string rods at the back side for cable support with contractor's own material like iron angle, nuts, bolts etc. The iron angle for fixing shall be minimum 3 mm thick. This also includes fixing of teak wood shelf minimum 25 mm thick for holding track circuit equipments. The work shall be done as per instructions of Rly engineer at site.

284

5948

1689365.48

... More
Fixing of ARA(M-6) Terminals /Screw less connectors / modular disconnect terminal 6 blocks and fuse blocks on phenolic laminated sheets and fixing by stainless steel/brass nuts & bolts. This includes provision of two additional holes on the board on either side for cable conductor entry. The work shall be carried out a per instructions of railway Engineer incharge. (Supply of all above terminals has been covered separately)

10000

24

240500

... More
Termination of Outdoor Cables (Main Cables /tail cables) at ARA/Disconnect type 7 terminals provided in Apparatus Cases, Cable termination rack in relay room, station building etc. The item includes dressing of cables and wires with dressing threads as per standard practice. All material required for this item will be supplied by contractor. The outdoor cable shall be terminated in Relay Room, ASM Room etc. under supervision and instructions issued by Engr. incharge of the work.

56000

19

1098720

... More
Painting of two coats of Enamel paint over one coat of Red Oxide primer after scrapping 8 and cleaning of the surface of Full size Apparatus Case. Paint to be of reputed make Asian/Delux/Berger or similar. Painting of Apparatus Cases from inside and outside to be done by Silver colour.

284

905

257244.36

... More
Painting of two coats of Enamel paint over one coat of Red Oxide primer after scrapping and cleaning of the surface of Main Signal post, base, unit and complete fittings of Signal. Paint to be of reputed make Asian/Dulux/Berger or similar.

200

1214

242924

... More
Lettering and Numbering of Signals, TLJB, Mushroom housing, Apparatus Cases, Point Machine, Glued/Block Joints etc. (Each item to be taken as one unit). Work is to be carried out as per standard practice.

2500

113

284175

... More
Lettering and numbering of detail and description writing of particulars of terminations 11 and equipments on relay rack, relays, cable termination rack, battery and power equipments, IPS, operating panel, axle counter, inside location boxes as per location chart etc. constituting entire system with contractor's own paint and writing material (Asian make paint to be used). This includes supply and fixing of Teflon strip 3 mm thick and 25 mm wide for each row of relays and cable termination. This work shall be done as per existing practice of the Railway.

12

12526

150317.88

... More
Installation, testing and commissioning of Micro Processor based Data Logger Systemwith 512 digital inputs and 32 analog inputs with protocol converter as per RDSO Spec. No. IRS (S) 99/2006 (Amnd. 3) or latest. It includes supply of all the items required for complete indoor relay room wiring from data logger to relay rack tag blocks, drawing/extension of power supply upto Data Logger. It includes relay room door lock checking arrangement, commercial power supply monitoring arrangement & monitoring of DG sets, ELD, IPS, UFSBI, BI, MSDAC, interfacing with EI and interlinking & networking of Data logger. It also includes installation of MODEM and other interfacing cards, if required for networking of Data Logger. Note: Total numbers of relays and other signalling functions/gears required to be wired as per list circulated vide RDSO Letter No.STS/E/Data logger dtd.12.09.2011 or latest guidelines.

12

87663

1051960.8

... More
Horizontal Boring/Manual moling without damage to surface road /track for laying/ insertion of DWC/GI/HDPE pipe. The bore shall be done at the depth of minimum 1400 mm from the 13 ground level. The ground level shall be considered ignoring the bank height of the bank of the road/ track. Contactor shall provide all materials required for work and adequate nos. of labours for proper laying of cables into the bore. Cables shall be laid cautiously so that these should not get damage due to rough handling & pressure on cable. Payment of boring shall be made only after laying of DWC/HDPE/GI pipe in the bore. (Note:- DWC/HDPE/GI Pipe supply is not covered under this item.)

3000

1438

4316580

... More
Horizontal direction drilling (HDD)/ Trenchless digging/ machine drilling without damage to surface road/ track for laying/ insertion of HDPE/GI/DWC pipe. The bore shall be done at the depth of 14 minimum 1400 mm from the ground level. The ground level shall be considered ignoring the bank height of the bank of the road/ track. Contactor shall provide all material required for work and adequate nos. of labours for proper laying of cables into the bore. Cable shall be laid cautiously so that it should not get damage due to rough handling & pressure on cable. Payment of boring shall be made only after cable is laid in the bore.(Note: - DWC/HDPE/GI Pipe Supply is not covered under this item.)

20000

797

15954400

... More
Laying and fixing of Medium class GI pipes 100 mm dia (4.5 mm thickness) as per IS 1239 (Part 1) 2004 or latest with coupling on culverts/bridges, perforated at a distance of 20 cm or less with 10 mm dia hole, or at any other locations as decided by Site Engineer. The GI pipe is to be filled 15 with chattered compound. It includes supply of all material required for fixing arrangement. Contractor will also supply flexible/corrugated HDPE pipe at the end of GI pipe to protect the cables from sharp edges and sudden bends. The laying and fixing to be done as per RDSO drawings no. SDO/cable laying/011 and SDO/cable laying/012, issued vide RDSO document no. RDSO/SI/G/2010 Version 1.1 dated 04.02.2014, or latest.

200

470

94118

... More
Excavation of cable trench as per cable route plan, 1.2 Mtr. deep and of 0.3 Mtr. to 0.6 Mtr. wide at bottom as per RDSO Sketch No. SDO/CABLE LAYING/003, issued vide RDSO document no. RDSO/SI/G/2010 Version 1.1 dated 04.02.2014 or latest, alongside the track in normal soil/strata (including soft rock), conforming to distances as per cable route plan and refilling and ramming of 16 loose soil. This work includes clearing of route from bushes etc, covering of cable laid in trench by loose soil for a layer of 50mm thickness approximately before covering by bricks. The work shall be done as per the extant practice on North Eastern Railway and instructions of Railway Engineer at site. In case the full depth is not available, there shall be no proportionate payment and after the approval of minimum JAG officer, the concreting shall be done as per the RDSO drawing no. SDO/Cable laying/008, issued vide RDSO document no. RDSO/SI/G/2010 Version 1.1 dated 04.02.2014 or latest.

140

62241

8713875.8

... More
Excavation of cable trench as per cable route plan, 1.2 Mtr. deep and of 0.3 Mtr. to 0.6 Mtr. wide at bottom as per RDSO sketch No. SDO/CABLE LAYING/003, issued vide RDSO document no. RDSO/SI/G/2010 Version 1.1 dated 04.02.2014 or latest, alongside the track in Rocky soil, conforming to distances as per cable route plan and refilling and ramming of loose soil. This work includes clearing 17 of route from bushes etc, covering of cable laid in trench by loose soil for a layer of 50mm thickness approximately before covering by bricks. The work shall be done as per the extant practice on NER and instructions of Railway Engineer at site. In case the full depth is not available, there shall be no proportionate payment and after the approval of minimum JAG officer, the concreting shall be done as per the RDSO drawing no.SDO/Cable laying/008, issued vide RDSO document no. RDSO/SI/G/2010 Version 1.1 dated 04.02.2014 or latest.

1

95417

95417.72

... More
Cutting of all types of platforms/ road crossing and trenching and excavation to a width and depth of 300 mm x 300 mm, laying of DWC/HDPE/GI pipe in the trench and refilling and concreting 18 it afterwards as per original condition. In hard rocky ground area, cables will be laid normally on layer of soft earth of atleast 5cm thickness previously deposited at bottom of the trench. The cutting to be filled and finished with cement/concrete, as per the RDSO drawing no. SDO/Cable laying/008, issued vide RDSO document no. RDSO/SI/G/2010 Version 1.1 dated 04.02.2014 or latest.

500

211

105515

... More
Installation of Thermo shrink jointing kit as per RDSO specn No. IRS: TC 77-2012 (Rev 3.0) with (Amdt-1 to 3) or latest suitable for 6 quad /jelly filled cables for straight through/derivation joints from OEM trained staff as per procedure specified by RDSO and standard practices of Railway including excavation of pit for joint.

-

-

19

... More
Breaking o f RCC concrete in Relay Room/ Panel Room at station for drawing various sizes of cables.

9

6668

60020.37

... More
Laying of HDPE duct as per the approved cable route plan in the excavated trenches/ other protected works/RCC channel etc. including all accessories like end caps, collars, bends, couplers 21 etc. The ends of the duct to be sealed with end plugs till OFC blowing is done. Note: The laying of OFC cable independently or along with Quad cable/PIJF cable in the same trench shall be governed by the RDSO drawings no. RDSO/TCDO/COP-6(a) and RDSO/TCDO/COP-8(a) respectively, issued vide Chapter- XIII of the Telecomm Manual.

240

8656

2077600.8

... More
Blowing/drawing of OFC cable in the HDPE pipe duct and protective work already 22 provided in the trench. The cable shall be laid only after the successful completion of the DIT (Duct Integrity test). The DIT should be certified by the Railway engineer at site. All the equipments/machinery required shall be arranged by the contractor.

240

12297

2951460

... More
Construction of OFC jointing pit of size 1mx1mx0.6m, using bricks, sand and cement in 23 the ratio 1:3 including excavation of pit for joint enclosure. The thickness of the wall shall be 120 mm. The top cover shall be of concrete of thickness 75 mm with two iron handles on top of it. The pit shall be covered with sand after putting the joint enclosure. All construction material to be supplied by contractor.

122

8311

1014017.64

... More
Splicing of Optical Fiber Core and routing in joint closure/FDMS as per instruction of site Engineer.

7200

117

843336

... More
Laying of S&T Cables of various cores/ pairs/ quads in trenches/ GI pipes/ RCC pipes/ DWC pipes etc. as per the site requirement and as per approved cable route plan. This also includes 25 laying of cables in track crossings & road crossings. (Cables will be meggered before and after its laying by contractor under supervision of Railway Representative and contractor shall submit the meggering report of each testing). Length of the cable laid includes the length of the cable coiled for termination purposes. Per

1000

9085

9085120

... More
Training of Sr. Engineers/ Engineers/ Technicians/Jr. Engineers regarding installation, 27 testing, commissioning maintenance, repairing and troubleshooting of EI, MSDAC and other equipments. (Hard and Soft Copies of Training Material/Course Modules on each subject shall given to Each Participant).

50

4366

218308

... More
Loading, Transportation/Carriage and Unloading of various S&T material by a 9 MT 28 truck, from/to the consignee depot to/from various locations, as decided by the site incharge of work of Railway. The rate includes all tax, license fee, road permit, driver wages, fuel, repair and maintenance cost etc.

50000

72

3629500

... More
Transportation of less heavy material and man power, supply and running of 1 MUV to the sites of work as per requirement and direction of engineer incharge of work along with driver. The rate includes all tax, license fee, road permit, driver wages, fuel, repair and maintenance cost etc.

50000

46

2322500

... More
Conversion of 2/3 aspect signals into 4 aspects semi-automatic signa ls of stations. It includes fixing of 'A' marker, all LEDs & wiring of complete signals including 'A' marker. It also includes releasing of existing colour light signal unit and installation of new signal unit. Work to be executed as per instruction of site engineer.

-

-

30

... More
Conversion of 2/3 aspect signals into 4 aspects semi-automatic signa ls of stations. It 31 includes fixing of 'A' marker, all LEDs & wiring of complete signals including 'A' marker. It also includes releasing of existing colour light signal unit and installation of new signal unit. Work to be executed as per instruction of site engineer.

1800

518

933300

... More
Circuit wiring/ jumpering as per circuit diagrams in the relay racks/ tag blocks at PI stations in connection with alteration work. This includes preparation of Jumper sheets by wire man 32 duly checked by firm's site supervisor & wire to wire testing as per circuit diagram. Any wrong jumper done by wireman will not be paid & correction shall be done free of cost. Jumper wires will be supplied & issued by Railways. Good quality solder resin core to be supplied by contractor for soldering of Jumper wires. Soldering of jumper wires to be done after completion of testing by Railways. (Jumper=Number)

10000

16

166300

... More
Modification in Domino type Control cum Indication Panel of station in connection with 33 conversion of UP & DN main line signals into semi-automatic signals including supply of required nos. of Domino Units with Top cover plate, Top Plate with Buttons, Panel Indication LEDs of required colours as per approved Panel Diagram including panel wirings.

7

19923

139464.5

... More
Cement concrete work for miscellaneous, unscheduled items in ratio 1:3:6 of cement, 34 coarse, sand and aggregate Item includes excavation, ramming of CC by using vibrator, curing and plastering with cement and sand mixture in ratio 1:4 (aggregate will not exceed beyond 3.8 cm). The aggregate, cement and sand will be supplied by contractor. 35

120

6786

814412.4

... More
Supply of Resin core 60/40, 18 SWG (Philco/Khosla or similar reputed make)

18

1853

33366.06

... More
Dismantling and releasing of existing Electrically operated LC gate/Mechanically operated LC gate and all other associated fittings. All the released material will be transported to the SSE/Consignee depot.

14

11665

163316.58

... More
Dismantling and releasing of existing Location boxes/Apparatus cases/Jn boxes and all other associated fittings. All the released material will be transported to the SSE/Consignee depot.

100

1291

129115

... More
Dismantling and releasing of existing Signals and all other associated fittings. All the released material will be transported to the SSE/Consignee depot.

85

2031

172703

... More
Final location survey of cable route and final preparation of route plan as per code of practice for installation & commissioning of optic fiber & Quad cable system (STT/FO/1 issued by RDSO, 39 Lucknow) including supply of final cable route plan giving all necessary details as per following. (i). Two sets initially for approval and commencement of work on A3 size paper. (ii). One set in soft copy (in editable AUTOCAD format) in Pen drive. (iii). One set of original tracings. (iv). Five sets of final 'As Made' completion plans/diagrams on white bond paper of A3 size in proper bounded form.

57

1204

68638.83

... More
(a). Design, preparation and supply of the following Technical documents: (i). Installation, Testing, Commissioning and Maintenance manuals. (ii). Functioning and System overview manuals (b). Design, preparation and supply of the following the following completion documents: (i). Application Logic circuits (ii). VDU/CCIP diagram (iii). Interface Circuit/Wiring diagrams consisting of Relay contact analysis chart, Relay disposition chart, Relay contact to contact wire list chart, VDU/CCIP cable termination chart, Power supply diagram, Electronic signalling equipment and Power supply layout diagram, Relay rack and Cable termination rack layout diagram, Relay rack and Cable 40 termination rack particulars, Fuse, Resistors, Condensors etc. particulars, Details of Analog and digital inputs to be supplied to Data logger, Wiring diagrams for SSDAC/ HASSDAC/MSDAC etc. (iv). Cable Route plan with overlaid Location Boxes placement as per standard practices of NER. (v). Cable Core plan with overlaid Location box placement (vi). Location huts/Gate Lodge wiring diagrams. (vii). Location boxes wiring diagrams (viii). Track circuit bonding plan (ix). Earthing particulars plan (x). Station working rule diagram (SWRD) (xi). Station working rule (SWR) (xii). Selection table/ Route control chart Note: All the above completion documents should be supplied as follows: (i). Two sets initially for approval and commencement of work. (ii). One set in soft copy (in editable AUTOCAD format) in Pen drive. (iii). One set of original tracings. (iv). Six sets of final 'As Made' completion plans/diagrams in proper bounded form.

12

235437

2825247.24

... More
Supply of Skilled worker (supervisor) for over all supervision for ongoing works at site atvarious locations and maintaining records etc. for progress of day to day assisting in preparing detail paper works etc (For 'B' class area) as specified by ministry of labour and employment , goverment of india ,office of chief labour commissioner;s case No 1/26(1)/2021-LS-II dt.28.10.2021 .

180

764

137592

... More
LAYING OF DWC PIPE (upto 120 MM) WITH SOCKET COUPLER IN TRENCHES AS PER DIRECTION OF SITE ENGINEER.

500

7

3615

... More
LAYING OF DWC PIPE (200 MM) WITH SOCKET COUPLER IN TRENCHES AS PER DIRECTION OF SITE ENGINEER.

1000

20

20940

... More
Installation, wiring, testing and commissioning of Micro Processor based Remote Terminal Unit (RTU) with 128 digital input and 16 analog input as per RDSO Spec. No. IRS (S) 99/2006 (Amdt. 3) or latest. It includes supply of all the items required for complete indoor relay room wiring 44 from RTU to relay rack tag blocks, drawing/extension of power supply up to RTU. It includes supply of relay room door lock checking arrangement, commercial power supply monitoring arrangement & monitoring of DG sets, ELDs, IPS, interlinking and networking of RTU. It also includes installation of MODEM and other interfacing cards, if required for networking of RTU. Note: Total numbers of relays and other signalling functions/gears required to be wired as per list circulated vide RDSO Letter No. STS/E/Data logger dtd.12.09.2011 or latest guidelines.

3

51181

153543.75



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.