If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
North Eastern Railway - NER Tender
Plastic and Rubber
Ireps
Opening Date10 Aug 2023
Closing Date31 Aug 2023
Tender Amount₹ 92,92,404.65
Costs
EMD
₹ 1,85,900Document Cost
Refer DocumentsTender Fee
Refer Documents
Summary
Electrical Miscellaneous Works Related To Maha Kumbh Mela-25 At Prrb & Jhusi.
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
E-Tender-L-09-23-24-VARANASI DIVISION-ELECTRICAL/NORTH EASTERN RLYTender No
E-Tender-L-09-23-24Tender Authority
North Eastern Railway ViewPurchaser Address
-Website
http://ireps.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Carriage and transportation of above panel at site including loading & unloading charges.
2
1347
2695.84
Supply installation, testing and commissioning of end termination of existing cables in new panel with lugs, glands and hardware & connection to different switches MCCBs busbar etc as per connection diagram.
28
279
7833.84
Making pucca trench of 1 Mtr depth, 0.8 Mtr width with brick, cement & sand including finishing and polishing by cement solution as per drg no-L/BSB/02/12-13 dt-25.02.13.
8
699
5595.52
Supply, installation, testing and commissioning of Triple Pole Air- break Gang Operating air break off load disconnecting switch (GOS) 11 KV 400 Amp. complete with drop out fuses, 3 insulator triple pole each pole consists of galvanize steel base HT insulator as per BIS non ferrous knife and spring loaded contact arcing 08 horn of adequate section to break magnatisening current of the transformer horizontal GI shaft/ pipe of adequate length for phase separator, adequate length for operation from ground level and operation handle complete with locking arrangement in both OFF & ON position. All ferrous part heavily tinned with stand weather. Fuse shall be conforming to IS:9385 part-I/1979, GOS shall be conforming to IS: 9921 Part-I/1981&9921 Part-III/1982.yype complete with operating rod, drop out fuse and locking arrangement etc. conforming to IS: 1818-1992 or latest including provision of mounting arrangement for GOS as req.
2
11040
22080
Supply, erection, testing and commissioning of Mobile charging board made by hard board 10mm 09 thick size 205mm x 215mm x 60mm, 4 nos sockets 2/3 pin 6 amp on each board. One no indication lamp on each board, fuse Kit Kat on each board, fixing of 205mmx160mmx10mm thick hard board sheet for supporting of mobile phone.
2
410
820
Supply & fixing of 32 mm dia GI pipe (med) pipe conforming to IS: 1239 Part-I-2004 bracket complete with two NOs clamp nuts, bolts etc. suitable for mounting of LED street light fitting on tubular poles including bending the pipe to the required shape.
40
325
13000
Supply , testing and commissioning of sheet steel clad dust and vermin proof floor mounted type Junction box of dimension at least (Length-0.75Mtr, Height-0.60 Mtr, Width-0.50 Mtr) with 14 SWG CR sheet for 11 main supporting frame and 16 SWG CR sheet for doors & covers including Al. bus bars 4 strips of size 40x5 sqmm suitable for rating 400 Amp and din rails for mounting MCBs and other hardware as required with RYB led indicator, Danger board, end termination of existing cables in junction box with lugs, glands and hardware, cleaning and painting of synthetic enamel spray paint (Double coating) including Making Plinth (Brick work) of size 0.8x0.6x0.6 Mtr for Junction box as per direction of Engineer In-charge at site.
8
13061
104490.56
Supply, fabrication, and erection of fabricated structure angle iron 35x35x5mm /40x40x6mm /50x50x6mm /65x65x6mm conforming to IS:808/1989(latest version) for supporting arrangement of different equipment complete with clamp, nut bolt etc complete in all respect as per site requirement.
120
65
7800
Provision of Earth pit with supply and fixing of GI earth pipe medium class 4.5 mts long ,40 mm dia 13 with masonry enclosure on the top, alternate layers of salt and charcoal for pipe earth electrode. And Supply & laying of 6 SWG GI wire as conductor electrode in 15mm dia GI pipe including soldering etc connection should be done as per drawing attached and as per attached Specification.
4
1549
6199.8
Supply, installation, testing and commissioning of 16 Mt. High Mast systems following works for:- Supply, installation, testing and commissioning of 16 Mt. High Mast systems totally hot dip galvanized suitable for wind velocity of 50 M/Sec as per IS:875 Part 3 1987 or latest version. The mast shafts shall be in two/three sections which can be joined by slip stress fit method. The system along with head frame, steel wire rope 4 mm 14 dia single drum winch, galvanized lantern carriage arrangement suitable for 8 luminaries along with motorized and mechanical lever for manual raising and lowering of lantern carriage, in built in base compartment of High Mast with arrangement to couple with the winch. Twin dome aviation obstruction light with 2 Nos lamp , feeder panel comprising main incoming switch MCB's, time switch, contactor, reversing starter and protective system etc as required for operation of high mast system etc as per high mast OEM make recommendation (RITES inspected material to be provided/used)..
3
299095
897285
Supply, installation, casting and commissioning of RCC foundation for 16 Mt. High Mast systems 15 along with erection of foundation suitable bolt manufactured from special steel along with nuts, washers, anchor plates and templates considering the safe soil bearing capacity at site as 10T/Sq. Mtr at 2 Mtr. Depth as per approved. Foundation structural design should be as per high mast OEM.
3
62610
187830
Fixing, testing & commissioning of LED flood light 200 watt including connection with twin core PVC insulated flexible copper conductor cable size 1.5 sqmm as per direction of site in charge.
24
750
18000
Supply, installation, testing and commissioning of three layered digital PLC lights based on LEDs 175 watt conforming to as per attached specification as following - (a)Controlled PLC should be able to delete or add colour as per client requirements which will signal lights to function accordingly. (b)Product: PLC digital light with inbuilt memory card reader, LED based, fixtures IP65. (c)Total power consumption 175 watt. (d) Life time in 18 hours: 50000 Hrs. (e)Body material: Pressure die aluminium casted, powder coated and toughened glass. (f)Throwing angle: First layer 25 degree, Second layer 60 degree and third layer 120 degree. (g)Control Panel: Programed Logic Control through DMX/cad-5 cables. (h)Wire junction box per light IP66 box. (i)Light source: LED (j)Input working voltage: 90V-290V (k)Surge External Protection: 10kV (l)Function: PLC based controller with sender and receiving ports. (m)Double heavy duty stand with 180 degree movement powder coated. (n)Lumen per watt: 100 Lumens (R+G+B) This item should be conforming to attached specifications. (RITES inspected material to be provided/used)
200
23530
4706100
Laying of LT cable of required size in open/ air /along wall with clamping arrangement. Cable laying work shall be governed by IS :1255/1983.(cable supplied by Railway).
10800
24
267948
Laying of one number XLPE cable of 1100V grade of size exceeding 25 sqmm but not exceeding 400 sqmm direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as req. Cable laying work shall be governed by IS :1255/1983.(cable supplied by Railway). (I) This method 20 involves digging a trench in the ground and laying cable(s) on a bedding of minimum 75 mm riddled soil or sand at the bottom of the trench, and covering it with additional riddled soil or sand of minimum 75 mm and protecting it by means of tiles, bricks or slabs. (II) Depth - The desired minimum depth of laying from ground surface to the top of cable is as follows: Low voltage and control cables -0•75 m, Cables at road crossings 1•00 m, Cables at railway level crossings (measured from bottom of sleepers to the top of pipe)- 1.00 m
7550
138
1049072.5
Laying of one number additional XLPE cable of 1100V grade of size exceeding 25 sqmm but not 21 exceeding 400sqmm direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as req. Cable laying work shall be governed by IS :1255/1983.(cable supplied by Railway).
7550
42
322234
Supplying and laying of 160 mm dia (OD-160 mm & ID-135 mm nominal) DWC HDPE pipe ISI 22 marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc direct in ground(75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc, complete as required.
1000
285
285510
Supply, installation, testing and commissioning of ON LOAD Change over switch 200Amp (TPN) conforming to IS:13947 part III /1983 or latest including hardware and insulators as required.
1
12500
12500
Supply , installation, testing and commissioning of MCCB 200Amp ,4 pole, 415V, Breaking capacity 25kA with adjustable thermal setting 70-100%, magnetic setting fixed type, including hardware and insulators as required Conforming to IS :13947(Part-II)/1993or (Latest version)
5
9709
48545.55