North Eastern Railway Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

North Eastern Railway - NER Tender

Works
Telecommunication Services
Electrical and Electronics
Electrical Works
Ireps
Opening Date11 Oct 2024
Closing Date16 Dec 2024
Tender Amount₹ 76,72,60,619.53 
Notes
Download

Costs

Summary

Work For "survey, Design, Supply, Installation, Testing And Commissioning Of Kavach Equipments In Sitapur City[ex] -burhwal, Burhwal Jn.-gorakhpur Cantt., Manaknagar [ex]-lucknow Jn-malhaur [ex] & Barabanki [ex]- Burhwal Of Lucknow Division And Gorakhpur Cantt.[ex] - Goldenganj [ex) Of Varansi Division On North Eastern Railway"

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply (Including 20% Spares), Installation, Programming, Verification and 4 Commisioning of RFID tags with enclosures and fixtures at stations and block sections consisting of LCs, IBS & Auto Signalling Sections. Station & adjoining double line block section will be considered as one set. This should comply with RDSO/SPN/196/2012 version 4.0 or latest as per technical Specification and Scope of work given in Tender Document. (Inspection of Supply portion by RDSO)

73

1025892

74890116

... More
Supply, Installation and commissioning of kit for configuring, programming & downloading execution and application data for Stationary Station TCAS equipment. (Inspection of Supply portion by RDSO) Route Kilo

8

240144

1921153.76

... More
Supply, installation and commissioning of FAT setup at divisional office/Zonal Training Center as per RDSO/SPN/196/2020 version 4.0 or latest. (Inspection of Supply portion by RDSO)

1

16500000

16500000

... More
Supply of kit for configuring, programming and downloading RFID Tag data as per RDSO issued guidelines. (Inspection of Supply portion by RDSO)

8

882050

7056400

... More
Supply, Installation, Programming, Verification and Commissioning of RFID tags with 9 enclosures and fixtures at block sections (Absolute/ Automatic Block Section) for the 3rd line or other alteration work. This should comply with RDSO/SPN/196/2012 version 4.0 or latest. (Inspection of Supply portion by RDSO) 10

600

16000

9600000

... More
Re-programming, Re-fixing and verification of existing RFID Tags. 11

900

4700

4230000

... More
Design of cable route plan as per technical specification and supply of 6 sets of documents in proper binding from approved drawings shall be taken and submitted to Railways. This 12 includes (but not limited to) circuit diagram, Contact Analysis (As made document), RFID Tag data, Stationary TCAS connectivity diagram, RFID Tag- TIN layouts, Table o f Control for entire section, Stationary and Loco TCAS interface diagrams, power supply diagram, frequency plan, TDMA based time slot allotment chart etc. and other manuals. (Inspection Agency- Consignee)

73

113031

8251286.36

... More
Supply, Installation and commissioning of Lab Models of station equipment, loco equipment, trackside components and simulator as per RDSO/SPN/196/2012 Version 4 or latest. (Inspection of Supply portion by RDSO)

2

6403845

12807691.68

... More
Preparation and Supply of Training e-learning Module for On-Board and Trackside System. This need to meet requirements of Railways. (3 Printed copies + 5 sets) (Inspection Agency- Consignee)

1

200754

200754.58

... More
"Training to Railway staff for each training package of 200 man-days. (1 LS = 200 Man Days)"

6

339250

2035500

... More
Supply, installation and commissioning of Test Bench for Station TCAS equipment as per RDSO/SPN/196/2012 version 4.0 or latest. (Inspection of Supply portion by RDSO)

3

1723390

5170170

... More
Modification/Alteration in existing EI (Electronic Interlocking) at Auto Hut for making it Kavach ready as per latest RDSO guidelines/TAN. It includes design and modification in existing Interface and Interlocking circuits and logic of EI system including modification in the VDU (Video Display Unit)/ CCIP (Control Cum Indication Panel), Maintenance Terminal (MPC), Data Logger, Relay rack wiring. The complete work should comply with the latest RDSO specifications and guidelines and 20 as per approved SIP and circuit diagrams. All the material required as detailed in technical specification of Tender document shall be provided by the contractor. The work also includes the supply of modified Selection table, Interface Circuits, VDU/ CCIP diagram etc. to suit the modified SIP. It also includes the carrying out of FAT, SAT (as applicable) jointly with Railways and satisfactory commissioning. All plans/ drawings/ circuits etc. should be prepared on AUTOCAD, approved softcopy to be supplied in Pen Drive and 06 sets of approved hard copies are also to be supplied. (Inspection by RDSO. However, items not covered under RDSO inspection will be inspected by consignee with manufacturer certificate)

21

1744372

36631830.06

... More
Supply (Including 10% Spares), Installation & Commissioning of Locomotive (on board) TCAS Equipment consisting of Vital computer & pheripherals such as Driver Machine interface, 2 RFID 21 Readers, 2 full duplex Radio modems, 4 UHF antenna, 2 GPS and GSM Antenna, two number of pulse generator/ wheel sensor with direction sensing and associated cabling and power supply arrangement, excluding Brake interface unit. This should comply to RDSO/SPN/196/2012 version 4.0 or latest. (Inspection of Supply portion by RDSO)

5

3935300

19676500

... More
Supply, installation and commissioning of Brake Interface unit suitable for different locomotives as per RDSO/SPN/196/2012 version 4.0 or latest. (Inspection of Supply portion by RDSO)

5

1302720

6513600

... More
Supply, installation a n d commissioning of Network Monitoring System (NMS) for Centralized monitoring of TCAS stations and Loco equipments as per RDSO/SPN/196/2012 version 4.0 or latest. (Inspection of Supply portion by RDSO)

2

7192100

14384200

... More
Supply of A3 Printer for printing NMS fault and exception reports similar toHP laserjet managed MFP M72625dn model or better (Inspection Agency- Consignee) 25

3

97472

292416

... More
Supply of Non-deteriorating type low voltage cylindrical head cartridge electric fuse 6/10 amp as per RDSO specification No. IRS/S/78/2006 with latest amendments/ revision from RDSO approved sources. (Inspection by RITES.)

780

103

80659.8

... More
Supply of Medium class GI pipes of 100 mm diameter (4.5 mm thickness) with thread collars as per IS 1239 (Part 1) 2004 or latest along with couplers at one side in 6 meter length & along with test report of manufacturer. (Inspection by RITES.)

804

1016

817531.32

... More
Supply of Phenolic laminated Sheet, resin bonded, grade P3 in standard size of 1220 X 1220 x 10 mm as per specification No IS 2036 of 1995 or latest. Test report of manufacture to be supplied. (Inspection by RITES.)

99

5901

584265.33

... More
Supply of basic material for Maintenance Free Earth as per RDSO/SPN.197/ 2008 or latest consisting of :1) Copper bond steel electrode 3 Mtr long 17mm dia with copper bonding 4 thickness of min. 250 micron & UL listed & marked-01 No.2) Earth enhancement compound RDSO Approved in sealed bag of 10 Kgs - 03 No.3) Copper strip 150 x 25 x 6mm - 02 No.4) Copper strip 300 x 25 x 6mm - 01 No.5) 35 Sqmm Copper Cable to connect earth electrode to MEEB - 15 Mtr Approx. (Inspection by RDSO)

131

14386

1884645.91

... More
" Supply of Q-Series Line Relay, AC immunized (QNA1 type), 8F/8B, 24V DC complete 5 with plug board (base plate), connectors, retaining clip etc. and conforming to BRS:931 and Specification No. IRS:S 34 68 & Amendment 6, S-23-88 & Amendment 1, S 60 78 & Amendment 1 or latest as applicable from RDSO approved sources. (Inspection of by RDSO.)

1066

4569

4871118.98

... More
Supply of QNN1 Twin neutral line relay, 4F-4B/ 5F-3B/6F-2B, 24 V DC along with plug board, retaining clips and connectors BRS:960 (Inspection by RDSO.)

2242

3911

8770502.22

... More
Supply of Apparatus Cases (full location box) as per RDSO Drawing No. RDSO/S-11500 or latest with miniature E type locks & keys. The key & handle shall be supplied at the rate of one set 7 per four Apparatus Case. The miniature 'E' type lock shall be as per RDSO Specification No. IRS: S- 30/64 or latest and of ward no 41or as required by consignee & RDSO Drg No SA 3473 /M & SA3474 A or latest and key as per RDSO Drawing No. 3377/M or latest. E type locks are to be fitted on both front & back doors of location box. (Inspection by RITES.)

55

28207

1551436.7

... More
Supply of 10 Sq.mm PVC insulated, multi-strand, single core, copper conductor 140/0.3 (140 wires, diameter of conductor 0.3mm) cable as per IS: 694 or latest, IRS: S 76-89 Amd. 3 or latest. Cable to be supplied in 100 meter coil. (Inspection Agency- Consignee)

1300

122

158691

... More
Supply of ARA Terminal Block made of PBT - 6 Way as per RDSO Spec. No. IRS: S75/2006 (Rev. 2) or latest & Drg. No.SA-23756 (Alt-4) or latest from RDSO approved sources.

5328

271

1448256.96

... More
Supply of 200 way tag block as per specification IRS: S 77/2006 Rev. 1.0 or latest and DRG. No. SA 24751 or latest. 11

75

1439

107925

... More
Supply of Digital Data Logger mother board to upgrade from 512 to 1024 digital inputs(Inspection by RDSO)

-

58958

294790

... More
Supply of STP CAT-6 cable complaint with latest EIA/TIA-568-C.2 Standard for CAT-6 cable 305 mtrs Roll/Bundle. (Inspection Agency- Consignee) 14

15000

20

301350

... More
Supply of Optical Power Meter having resolution of 0.1 db & measuring range +3 dbm to -60 dbm as per TEC specification No. GR/OPM-01/03 Feb 05 or latest. (Inspection by Consignee)

6

18191

109147.2

... More
Supply of Automatic Fusion Splicing Machine for single mode Optical fibre cable, along 17 with accessories as per TEC spec.TEC/GR/TX/OSM - 001/04/SEP-12 OT latest of make Superior/Fujikura or similar. Consignee shall approve the supply only after successful demonstration at site. Inspection: Consignee

3

374955

1124865.99

... More
Supply of Double Walled Corrugated (DWC) pipe with associated collars etc. as per RDSO Specification No. RDSO/SPN/204/2011 Ver. 1.1 & Amendment 1 or latest, anti-rodent & anti- 18 oxidant and non-flame propagating type of size 103.5 mm inner dia and 120 mm outer dia in 6 metre length suitable for taking underground communication/ signalling cables. One coupler with suitable rubber O-ring for jointing shall be supplied with each 6 mtrs. length. (Note: DWC pipe shall be marked at every ONE meter length in such a way that manufacturer's name & year of manufacturing can be easily identified. (Inspection of by RITES.)

2970

298

887139

... More
Supply of HDPE duct 40/33 mm Drum 500/1000 meter length as per RDSO Specifiction RDSO/SPN/TC/45/2013 revision 2.0 (Amdt.1.0 & 2.0) or latest. (Inspection by RITES.)

109

78753

8584128.23

... More
Supply of Portable Maintenance Terminal as Detailed Spec. in Tender Document. (Inspection by Consignee)

6

63999

383999.04

... More
Supply of Laserjet Printer for taking print out of various field data for analysis as per Technical Specifications mentioned in Tender Documents of make- HP/Canon/Epson or superior. (Inspection by Consignee.)

6

29369

176215.98

... More
Fabrication, Supply and Fixing of Cable Route Marker made with reinforced concrete in 1 the ratio 1:3:6, engraved with "NER-S&T" on the top portion on both the side duly painted as per RDSO Drg. No SDO/cable laying/020. Cable Route Markers are to be grouted at distance of approximately 100 meter on the cable route. (Inspection By Consignee)

990

449

445193.1

... More
Supply and installation of Earth Electrode as per standard practices and as per SEM Drawing No.19-D6 . It includes supply of GI pipe of 3m length. It includes connecting the earth electrode to the equipments which are required to be earthed including digging of earth pit 3 meter 2 deep and fixing earth electrode pipe, casting of cement concrete enclosure with cover. It includes supply, installation & fixing of 7 strand GI wires as earth lead wires, supported on MS flat size 5mm x 40 mm, soldering and nut bolt both, one end of both earth lead wire and MS flat to earth electrode and other end to Location boxes, block equipments, power equipments, cable sheath, signals etc. as per site requirement and as per instructions given by engineer incharge.(Earth Electrode Inspected by RITES)

131

3616

473811.28

... More
Supply and Installation of OFC joint enclosure and splicing of Optic fiber cable (48 3 fibers) and testing as per technical Specification No. GROJC- 2/02 sept 2003.Supply of splice enclosure (48 fiber) shall be as per Boards specification of TEC. All materials including fusion splicing machine used for fiber splicing and OTDR for testing and other testing materials if any shall be arranged by the contractor.

131

17782

2329520.6

... More
Construction of OFC jointing pit of size 1mx1mx0.6m, using bricks, sand and cement in 4 the ratio 1:3 including excavation of pit for joint enclosure . The thickness of the wall shall be 120mm .The top cover shall be of concrete of thickness 75 mm with two iron handles on top of it. The pit shall be covered with sand after putting the joint enclosure All construction material to be supplied by contractor.

131

8311

1088822.22

... More
Supply of Fibre Distribution Management system as per RDSO Specification No. RDSO/SPN/TC/37/ 2000 (Rev-20)with latest amendment and splicing of 2 No 24 fibre /1 nos of 48 fiber splicing of fiber with pig tel cable as per sepeification (Inspection by Consignee)

479

29527

14143902.42

... More
Supply, installation, fixing, wiring, testing & commissioning of Fuse Auto Changeover System(FACS) for Railway Signaling System as per RDSO Specification No. RDSO/SPN/209/2012 Ver.2 or latest for Relay room suitable for fuses from 0.63 Amp to 4 Ampere capacity for 12V/24V/60V/110V DC and 110V AC systems. One FACS Unit shall compromise 32 nos. of non-deteriorating or 'G' type 7 fuses of various capacity.The units shall be mounted on DIN rail in adequate size enclosure as per instructions of Railway site engineer. Two no.of NO+NC contacts shall be provided for remote monitoring. The changeover time shall be less than 1 msec. Theaudio-visual alarm for main and standby fuses shall be provided. Installation, wiring, testing & commissioning ofFACS consists of fixing of modules of fuse alarm system on existing rack, wiring from existing fuses to modules,soldering, lacing etc. Work is to be executed without affecting the functioning of existing circuits/ gears. (Inspection of Supply portion by RDSO)

86

42111

3621570.94

... More
Excavation of cable trench as per cable route plan, 1.2 Mtr. deep and of 0.3 Mtr. to 0.6 Mtr. wide at bottom as per RDSO Sketch No. SDO/CABLE LAYING/003, issued vide RDSO document no. RDSO/SI/G/2010 Version 1.1 dated 04.02.2014 or latest, alongside the track in normal soil/strata (including soft rock), conforming to distances as per cable route plan and refilling and ramming of 2 loose soil. This work includes clearing of route from bushes etc, covering of cable laid in trench by loose soil for a layer of 50mm thickness approximately before covering by bricks. The work shall be done as per the extant practice on North Eastern Railway and instructions of Railway Engineer at site. In case the full depth is not available, there shall be no proportionate payment and after the approval of minimum JAG officer, the concreting shall be done as per the RDSO drawing no. SDO/Cable laying/008, issued vide RDSO document no. RDSO/SI/G/2010 Version 1.1 dated 04.02.2014 or latest.

111

62241

6908858.67

... More
Cutting of all types of platforms/ road crossing and trenching and excavation to a width and depth of 300 mm x 300 mm, laying of DWC/HDPE/GI pipe in the trench and refilling and 3 concreting it afterwards as per original condition. In hard rocky ground area, cables will be laid normally on layer of soft earth of atleast 5cm thickness previously deposited at bottom of the trench. The cutting to be filled and finished with cement/concrete, as per the RDSO drawing no. SDO/Cable laying/008, issued vide RDSO document no. RDSO/SI/G/2010 Version 1.1 dated 04.02.2014 or latest.

600

211

126618

... More
"Excavation of Trenchless Track under Railway Track/Busy Road etc. at a depth of 1.20 meter below Ground Level and Culvert/River,(in HDD Portion) laying of 100 mm dia GI Pipe/DWC Pipe (of size 90/76 mm OD/ID) in it. Note:- GI Pipe/DWC Pipe will be supplied by Railway."

2970

595

1768456.8

... More
Horizontal direction drilling (HDD)/ Trenchless digging/ machine drilling without damage to surface road/ track for laying/ insertion of HDPE/GI/DWC pipe. The bore shall be done at the depth of 5 minimum 1400 mm from the ground level. The ground level shall be considered ignoring the bankheight of the bank of the road/ track. Contactor shall provide all material required for work and adequate nos. of labours for proper laying of cables into the bore. Cable shall be laid cautiously so that it should not get damage due to rough handling & pressure on cable. Payment of boring shall be made only after cable is laid in the bore.(Note: - DWC/HDPE/GI Pipe Supply is not covered under this item.)

43800

818

35857308

... More
"Breaking of metal/ tar road and refilling after laying the cables as per drawing no.SDO/CABLE LAYING/010. The surface of the road shall be concreted to match with the old surface."

4800

191

920160

... More
Laying of S&T Cables of various cores/ pairs/ quads in trenches/ GI pipes/ RCC pipes/ DWC pipes etc. as per the site requirement and as per approved cable route plan. This also includes 7 laying of cables in track crossings & road crossings. (Cables will be meggered before and after its laying by contractor under supervision of Railway Representative and contractor shall submit the meggering report of each testing). Length of the cable laid includes the length of the cable coiled for termination purposes.

164160

9

1492214.4

... More
Laying and fixing of Medium class GI pipes 100 mm dia (4.5 mm thickness) as per IS 1239 (Part 1) 2004 or latest with coupling on culverts/bridges, perforated at a distance of 20 cm or less with 10 mm dia hole, or at any other locations as decided by Site Engineer. The GI pipe is to be 8 filled with chattered compound. It includes supply of all material required for fixing arrangement. Contractor will also supply flexible/corrugated HDPE pipe at the end of GI pipe to protect the cables from sharp edges and sudden bends. The laying and fixing to be done as per RDSO drawings no. SDO/cable laying/011 and SDO/cable laying/012, issued vide RDSO document no. RDSO/SI/G/2010 Version 1.1 dated 04.02.2014, or latest.

804

470

378354.36

... More
CABLE Termination of Outdoor Cables (Main Cables /tail cables) at ARA/Disconnect type 9 terminals provided in Apparatus Cases, Cable termination rack in relay room, station building etc. The item includes dressing of cables and wires with dressing threads as per standard practice. All material required for this item will be supplied by contractor. The outdoor cable shall be terminated in Relay Room, ASM Room etc. under supervision and instructions issued by Engr. incharge of the work.

5150

19

101043

... More
" Breaking of RCC concrete in Relay Room / Panel Room for drawing cables and restoring walls /floor surface to normalcy. (One unit covers panel, relay, equipment rooms and OFC hut etc. of one station / IB / LC Gate)

96

6668

640217.28

... More
Alteration of database, faults, simulations in a Data loggers and all connected places (like HQ, FEP, STATION, etc) (Inspection By Consignee)

111

18370

2039070

... More
Blowing/drawing of OFC cable in the HDPE pipe duct and protective work already 12 provided in the trench. The cable shall be laid only after the successful completion of the DIT (Duct Integrity test). The DIT should be certified by the Railway engineer at site. All the equipments/machinery required shall be arranged by the contractor.

137

12297

1684791.75

... More
Laying of HDPE duct as per the approved cable route plan in the excavated trenches/ other protected works/RCC channel etc. including all accessories like end caps, collars, bends, couplers 13 etc. The ends of the duct to be sealed with end plugs till OFC blowing is done. Note: The laying of OFC cable independently or along with Quad cable/PIJF cable in the same trench shall be governed by the RDSO drawings no. RDSO/TCDO/COP-6(a) and RDSO/TCDO/COP-8(a) respectively, issued vide Chapter- XIII of the Telecomm Manual.

137

8656

1185963.79

... More
Excavation, casting, curing of foundation and installation & erection of Apparatus case Full (App. Case as per RDSO Drg. No. RDSO/S-11500 or latest) with contractor's own frame, anchor 14 bolts & nuts, cement and other material in the ratio 1:3:6 s foundation drawing of Railway. 'E' type lock to be supplied and installed with App. case. This includes filling of location foundations with river bed sand and plastering on top with a mixture of 1:4 of cement and sand, ramming of loose soil around foundation and disposal of loose dugged soil from site. It covers fixing of lamp holder, switch and lamp etc. in Apparatus Case

55

16307

896929



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.