North Central Railway Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

North Central Railway - NCR Tender

Works
Electrical and Electronics
Ireps
Opening Date15 Jan 2024
Closing Date6 Feb 2024
Tender Amount₹ 29,26,70,466.77 
Notes
Download

Costs

Summary

Design, Manufacturing, Supply, Installation, Testing Andcommissioning Of New Electronic interlocking At 7 Stations, Alteration In Existing Ei At Dholpur Station Including All Indoor & outdoor Signaling Work In Connection With Dholpur - Sirmuttra With Extension To Gangapur city Work Of Agra Division Of North Central Railway.

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Design, preparation and supply of the following Technical documents: (i) Installation, Testing, Commissioning and Maintenance manuals (ii) Functioning and System overview manuals (b) Design, preparation and supply of the following the following completion documents:(i) Application Logic circuits (ii) VDU/CCIP/LCP diagram (iii) Interface Circuit/Wiring diagrams consisting of Relay contact analysis chart, Relay disposition chart, Relay contact to contact wire list chart, LCP/VDU/CCIP cable termination chart, Power supply diagram, Electronic signalling equipment and Power supply layout diagram, Relay rack and Cable termination rack layout diagram, Relay rack and Cable termination rack particulars, Fuse, Resistors, Condensors etc. particulars, Details of Analog 4 and digital inputs to be supplied to Data logger, Block wiring diagram (if applicable), Wiring diagrams for SSDAC or HASSDAC or MSDAC or BPAC (if applicable) (iv) Cable Route plan with overlaid Location Boxes placement (As per NCR HQ Drg. No. TYP/14/0017 issued vide letter no. S&T/NCR/DRG/TYP dtd 29.12.2014)(v) Cable Core plan with overlaid Location box placement (vi) Location huts/Goomties wiring diagrams (if applicable) (vii) Location boxes wiring diagrams (viii) Track circuit bonding plan (ix) Earthing particulars plan (x) Signal Interlocking plan (SIP) (xi) Station working rule diagram (SWRD) (xii) Station working rule (SWR) (xiii) Selection table/ Route control chart All the above completion documents should be supplied as follows: (i) Two sets initially for approval and commencement of work (ii) One set in soft copy (in editable AUTOCAD format) in Pen drive. (iii) One set of Original tracings (iv) Six sets of final 'As Made' completion plans/diagrams in proper bounded form

8

177255

1418047.68

... More
Supply of embedded fanless PC based Maintenance terminal/Datalogger terminal as per RDSO 5 spec. No. RDSO/SPN/192/2019 Ver. 2.0 or latest & RDSO TAN No. - STS/E/TAN/3007 version 1 dated:02.11.12 . The size of VDU shall be minimum 42 inch, LED 4K resolution. Note: One table of suitable size alongwith revolving chair should be supplied with Maintenance terminal (make Godrej/Methodex or similar of reputed make)

8

388599

3108795.76

... More
Installation, wiring, testing and commissioning of embedded fanless PC based Maintenance terminal/Datalogger terminal as per RDSO spec. No. RDSO/SPN/192/2019 Ver. 2.0 or latest & RDSO TAN No. - STS/E/TAN/3007 version 1 dated:02.11.12 supplied vide item no 5 of Schedule A

7

97149

680049.09

... More
Supply of Laptop based work station for data input & configuration, simulation and functional testing 7 diagnostics and trouble shooting and commissioning of SSI system. Screen- min 13 inch, Ram-16 GB i5 processor, 512 GB SSD , Graphics card-NVIDIA GTX 1 650 4gb or better configuratior Specification to be approved by JAG/SG before supply of this item.

1

110044

110044.47

... More
Provision of Ring Earth for EI system, consisting of 06(six) number of maintenance free earths, which includes supply of all components of earthing & bonding system like earth electrode, earth enhancement materials, earth pit, equi-potential earth bus bar, connecting cables and tape/strips and other associated 8 accessories in accordance with RDSO Spec. No.RDSO/SPN/197 Ver.1.0 or latest and provision of earth pits to be connected in a ring to achieve less than 01(One) ohm earth resistance for connecting EI equipments, relay racks, panel , power equipments as per RDSO TAN no. STS/E/TAN/3006 dated 02.11.2012. Diagram of ring earth should be supplied to Railway for approval before execution. All related materials as recommended by RDSO in Spec . No.RDSO/SPN/197 Ver. 1.0 or latest, will be supplied by the contractor.

7

172246

1205724.87

... More
Q-Series Track Relay (QTA2 Type), AC immunized, 9 Ohms, 2F/1B along with plug board (base plate), connectors, retaining clips etc and conforming to BRS:939A & 966(Appendix F2) or latest and RDSO Specn.No.IRS:S 45"44 S-23 , S-60 or latest, as applicable.The interlocking code for this unit shall be "FGHKX".

210

3804

799045.8

... More
Supply and Installation of Glass fronted Key box for Crank handle etc. it should be done as per site supervisor instructions.

16

2459

39345.76

... More
Supply of 1 x 6 Sq mm (Red/Black/Green) multi strand copper power wire , 85 conductor each dia 4 0.30 +/- 0.01 with insulation thickness of 0.8 mm and nominal conductor resistance of 3.3 ohms/km and test parameters as per RDSO Specn.No.IRS:S-76/89 (Amnd.3) or latest.Colour of the wire will be specified by the Engineer incharge.

5000

47

239850

... More
Supply of 1 x 10 Sqmm (Red/Black/Green) multi strand copper power wire, 101 conductor each dia 5 0.45 +/- 0.01 with insulation thickness of 1.2 mm and nominal conductor resistance of 1.127 ohms/km and test parameters as per RDSO Specn.No.IRS:S-76/89(Amnd.3) or latest.Colour of the wire which is required will be specified by the Engineer incharge.

5000

125

627900

... More
Supply of 1 x 16 Sqmm (Red/Black/Green) multi strand copper power wire as per IS: 2465/1984 6 and IS:694:2010 or latest, 101 conductor each dia 0.45 +/- 0.01 with insulation thickness of 1.2 mm and nominal conductor resistance of 1.127 ohms/km and test parameters as per RDSO Specn.No.IRS:S-76/89(Amnd.3) or latest. Colour of the wire which is required will be specifi ed by the Engineer incharge.

5000

147

738850

... More
Supply and installation of Cable Termination(CT) rack as per drawing of NC Railway, complete along with fitting arrangements, wall supports, scaffolding and suitable grouting arrangements and also with 7 arrangement for fixing four 8-way terminal strips/ Screw less terminals/ ARA terminals. The CT rack shall be covered with hylum sheet of minimum 10 mm thickness for fixing of 8-way terminal strips/ Screw less terminals/ ARA terminals. Supply of 8 way terminal strips/ Screw less terminals / ARA terminals not covered under this item. Cable termination rack shall be corrosive resistant and powder coated.

32

48325

1546416.32

... More
Supply of Fuse auto changeover system for Railway Signaling System as per RDSO/SPN/209/2012 8 Rev.2 or latest for Relay room fuses up to 10 Ampere capacity for 12V/24V/60V/110V DC and 110V AC systems. The units shall be mounted on DIN rail in adequate size enclosure as per instructions of Railway site engineer. Two no. of NO+NC contacts shall be provided for remote monitoring. The changeover time shall be less than 1 msec. The audio visual alarm for main and standby fuses shall be provided. One set means set of each fuse.

1600

2248

3597072

... More
Supply of stretcher bar insulation complete set consisting of the following:- Plate-T-10367-1 No., Bush T- 10368- 3 Nos. and washer-T- 10371 -6 Nos.

108

363

39294.72

... More
Supply of IRS Type point machine 'D'/'P' bracket insulation complete set consisting of the following:- Plate LH - S-3266-1 No, RH - S-3265-1 No., Plate S-8804- 1 No., Bush - S- 3199 - 4 Nos, Bush S-8813- 2 Nos.

108

462

49907.88

... More
Supply of gauge tie plate insulation complete set each set consisting plate T-10372 = 1No., Bush T- 10368=3 Nos. and washer - T-10371 = 6 Nos.

108

364

39341.16

... More
Fabrication and supply of point rodding (Ground Connection) set for electric point machine (RDSO Type) as per RDSO Drg. No.SA-8800-01, 20-21, 9151-52,9000-01,03-04,9065-66,9101, as applicable.

98

14771

1447565.84

... More
Supply of Track Lead Junction Box(TLJB), 4 way, 250 mm x 255 mm x120 mm made from FRP, as per Drg.No. 20101/M(IRS) or latest, including brass bolts and hylam board sheet with terminals etc. The FRP material shall be as per RDSO spec. RDSO/SPN/151/1997 or latest.The technical specifications are as follows: (a) 13 TLJB complete with cover to be in black/red/grey with all the holes required for mounting on FRP stump (vertical two for each FRP angle) HDPE pipe , cable etc. (b) Each TLJB shall have two bakellite terminal block fitted horizontally, each bakellite terminal block shall have two nickel chrome plate with brass terminal. Alongwith each TLJB , nickel chrome plated brass links(two nos.of adequate strength for vertical linking of the terminals to be supplied. (c) HDPE pipe alongwith two nuts for fixing on the TLJB hole . (d) The FRP stump for mounting the TLJB

450

5339

2402919

... More
Supply of Adjustable Track Feed Resistance 30 Ohms (Disc Type), Phenolic moulded base, as per RDSO Drg. No.SA-20161-66/M or latest

210

2280

478972.2

... More
Supply of B Type Choke as per RDSO Specn.No.IRS:S-65/83 (Amnd. 3) or latest.

420

5911

2482964.4

... More
Supply of Hydrometer, Exide make or similar for measuring specifi c gravity of Battery Graded acid with mounting stand in location Boxes.

20

355

7114.8

... More
Supply of uncharged Low Maintenance Lead Acid (LMLA) secondary cell, 2V, 80 AH, in dry condition, shelf mounting type, conforming to RDSO Specn.No.IRS:S-88/2004 or latest, with inter cell connectors, nuts and bolts, washers, microporous vent plug, float etc.

630

3111

1960402.5

... More
Supply, installation, testing and commissioning of Track Feed battery charger alarm system as per 19 RDSO spec. IRS: S-89/2013 Ver.1.0 or latest, to work on 110 V AC system, having terminals for connecting all 3 supplies and indications for mains and charger failure and drive potential free contacts all with contractor's own material (per track).

210

3731

783669.6

... More
"Multi section Digital Axle Counter (MSDAC) supply, design, installation, testing and commissioning of multi section digital axle counter (MSDAC) complete system as per RDSO Specification No.RDSO/SPN/176/2013 version 3 with Latest amendments or latest. Suitable for commissioning of yard/Auto Section / dual detection (DCTC|AFTC with MSDAC) . MSDAC should have facility to reset track sections. Design of axle counter circuit indoor installation testing and commissioning of multi section digital axle counter (per unit), supply of essential 10% spares covering all types types of cards, wheel sensors for MSDAC . Supply of Diagnostic system for Remote diagnostics Tool set for wheel sensor mounting and maintenance of MSDAC consisting of torque wrench, ratchet, testing plate, measuring tape, screw driver, gloves and multimeter fluke 115 (1 Nos. per 14 DP). " NOTE- 1.If any housing is required to keep outdoor equipment, it has to be supplied with the equipment 20 with no extra cost. 2. Maintenance free earthing (supply and installation) for track device/mushroom housing etc to be done by the contractor if required by system design. No extra cost/ payment will be made by this Railway: 3. Automatic resetting facilities through hardware /software for auto resetting to be provided by contractor by his own materials for this no exta cost /payment will be made by Railways. 4. MSDAC system networking to be done with central: control room. Required hardware PCI network equipment to be provided by the contractor, no extra cost /payment will be made for this by Railway. Point El Channel/media will be provided by Railway for this purpose from nearest Railway station. 5. All other Hardware like TPR, Extra card to make dual DP, Modem, ethernet switches ete if required for commissioning and final track section pick up will be supplied by contractor, no extra payment will be made by this Railway. 6 Separate evaluator for UP and Down line to be provided at Station/RH as (decided by Railway site engineer. For the communication between evaluator to evaluator (RH to Station) Quad/ OFC Link (dark fiber) will be provided by Railway. Any other Networking equipment required will be supplied by contractor at no extra cost. 7. Manual resetting through reset box at if station to be provided as per requirement.

60

354930

21295837.8

... More
Supply of Tools Kit for Digital Axle Counter (Multi section/Single section). (MSDAC comply to the RDSO spec.RDSO/SPN/176/2013/Ver.3 or latest and manufacturer's specification and SSDAC comply to the RDSO/SPN/177/2012, Ver.3 or latest respectively). The tool kit shall be minimum equipped with the following 21 equipments: (i) All mechanical tools shall be of reputed make like Taparia/Bosch etc. (ii) Digital multimeter true RMS type of make Fluke 189 or similar reputed make with probe set - 1 no (iii) Adjustable torque wrenches 25-135 N/mtr with 13 mm and 19 mm inserts- 1 set (iv) Set of spanners screw drivers and soldering iron - 1 set (v) Dummy wheel - 1 no. (vi) Marking Jig - 1 no. (vii) Adapter card - 1 no. (viii) Extended wired socket to inetrface with diagnostic plug - 1 no. (viii) Selector switch on panel base - 1 no. (ix) DAC EC card puller etc.

4

122070

488282.72

... More
Supply of Colour Light Signal Post, Tubular Mild steel, 4.5 m length, 140 mm Dia, as per RDSO 22 spec. No. IRS: S-6/81 or latest and Supply of cast iron Main signal surface base (As per RDSO Drg. No. 2011/M or latest), with CLS ladder assembly suitable for colour light signal 4.5 m long, as per RDSO drg. No. SA 23153 and signal front staging complete assembly and complete signal back staging for CLS unit.

114

25285

2882512.8

... More
Supply of Position Light Shunt Signal Unit Complete,Metallic, Independent type, along with base and post, hood, Cover etc as per Drg. No. SA-23840 (Adv.) suitable for LED Signal Lighting Unit.(Supply of LED Unit is not covered in this item)

33

4080

134664.42

... More
Supply of Position Light Shunt Signal Unit Complete, Metallic, Post type, along with Offset bracket, Hood, Cover, mounting socket etc as per Drg. No. SA-23840 (Adv.) or latest, suitable for LED Signal Lighting Unit. (Supply of LED Unit is not covered in this item)

14

8856

123988.06

... More
Supply of Offset brackets for Main Signal, made of Mild Steel, outer diameter 140 mm (5.5 inch), thickness of pipe 4.5 mm with fixing arrangement on Main Signal post as per Drawing No SA-23080/Adv.along with fixing U bolts, nut and clamps.

20

1207

24142.8

... More
Supply, fabrication and fixing of Retro-reflective Signal number plates as per NCR drg. No. TYP/14/0014 dtd 28.11.2014 issued vide NCR letter no. S&T/NCR/DRG/TYP dated 28.11.2014,on signal post with contractor's own material like clamp, U bolts, nuts etc.

116

744

86401.44

... More
Supply, fabrication and fixing of retro-reflective marker/boards/plates as per the following: 27 'P'marker-Non illuminated as per Drg. no.SA-23456 (Adv)/'AG' marker-Non illuminated as per Drg. no.SA-23459- 60 (Adv)/ 'A' marker - Illuminated as per Drg. no.SA-23461(Adv)/ 'G' marker -Non illuminated as per Drg. no.SA- 23477(Adv) or as applicable and provided by Railways.

54

887

47939.58

... More
Supply, fabrication and fixing of the Calling On board/BSLB board as per RDSO Drg. no. SA 2373 (Adv)/Stop/Warning board as per drg. no SA-2380 (Adv), or as applicable, on concrete foundation and painting with Retro reflective paint. All work to be carried out as per Railway site engineer instructions

24

8112

194699.52

... More
Supply of hand cuff lock of Godrej/Navtal or reputed make with key and as approved by site engineer.

150

460

69078

... More
Supply of Non Metallic (FRP) colour light signal housing multi unit type for railway signaling suitable 30 for RE area TWO Aspects, complete without lenses, lamps and signal transformer as per RDSO Drg. No. SA 23003 A/M (Adv.) and as per RDSO spec. No. RDSO/SPN/194/2006 (Rev 2.0) or latest and FRP material as per RDSO SPEC. No. RDSO/SPN/151/1997 or latest.

48

31322

1503472.8

... More
Supply of Non Metallic (FRP) colour light signal housing multi unit type for railway signaling suitable 31 for RE area THREE Aspects, complete without lenses, lamps and signal transformer as per RDSO DRG. No. SA 23002 A/M (Adv.) and as per RDSO spec. No. RDSO/SPN/194/2006 (Rev 2.0) or latest and FRP material as per RDSO SPEC. No. RDSO/SPN/151/1997 or latest.

66

35753

2359740.9

... More
Supply of Non Metallic (FRP) colour light signal housing multi unit type for railway signalling suitable 32 for RE area FOUR Aspects, complete without lenses, lamps and signal transformer as per RDSO Drg. No. SA 23001 A/M (Adv.) and as per RDSO spec. No. RDSO/SPN/194/2006 (Rev 2.0) or latest and FRP material as per RDSO SPEC. No. RDSO/SPN/151/1997 or latest.

2

42250

84500.14

... More
Supply of Junction route indicator unit 2 way, made of FRP, (Without Lenses & Holder) as per Drg. No. SA 23401-06 (Adv.) (as applicable) suitable for LED Signal Lighting Unit and as per RDSO spec. IRS: S-66/84 Amd.-1 or latest and RDSO/SPN/194/2006 Rev.2 or latest.(Supply of LED Unit is not covered in this item)

16

54127

866036

... More
Supply of Junction route indicator unit 4 way, made of FRP, (Without Lenses & Holder) as per Drg. No. SA 23401-06 (Adv.) (as applicable) suitable for LED Signal Lighting Unit and as per RDSO spec. IRS: S-66/84 Amd.-1 or latest and RDSO/SPN/194/2006 Rev.2 or latest.(Supply of LED Unit is not covered in this item)

2

49751

99502.54

... More
Supply of Calling ON Signal Unit, non metallic, with Brackets, clamps and fixing accessories, 35 suitable to LED signal lighting unit and as per RDSO spec. RDSO/SPN/194/2006 (Rev. 2.0) or latest. The FRP material shall conform to RDSO/SPN/151/1997 or latest. Calling On Signal Unit shall conform to RDSO Drg no SA- 24351(Adv) Alt1 or latest without lamp, lamp holder and lens.

18

11667

210012.66

... More
Supply and fixing of protective screen of expanded metal 12 SWG of size 1200 x 1500 mm on signals as per std. practice in RE Area and earthing the screen with MS flat of 2"x 1/4"using GI nut bolts and washer.

2

3513

7027.04

... More
Supply of Apparatus Case/Location Box Full as per RDSO drg. no. RDSO/S-11500 or latest, with 'E' 37 type lock and key ward no. 42, . The key and handle should be supplied at the rate of one no. per four Apparatus cases. The 'E' type key lock is as per RDSO Spec. IRS;S-30/64 or latest, RDSO drg. no.SA 3376/M or latest and Key is as per Drg. No. 3377/M or latest.Note: This item includes the supply of 2 Nos E Type Lock fitted on both doors, along with two Keys

280

27512

7703455.2

... More
Supply of Apparatus Case/Location Box Half as per RDSO drg. no. RDSO/S-11507 or latest, with 'E' type lock and key ward no. 42, . The key and handle should be supplied at the rate of one no. per four Apparatus cases. The 'E' type key lock is as per RDSO drg. no.SA 3376/M or latest and Key is as per Drg. No. 3377/M or latest.Note: This item includes the supply of 2 Nos E Type Lock fitted on both doors, along with two Keys.

80

19913

1593100.8

... More
Supply of phenolic laminated Sheet, resin bonded, grade P3 in standard size of 1220 X 1220 x 10 mm as per spec. No. IS 2036 of 1995 or latest. Test report of manufacture to be supplied.

200

5756

1151228

... More
Fabrication and fixing of phenolic laminated sheet of grade P3, minimum 10 mm thick,as per Apparatus case diagram/plan, in location box by providing all fixtures like ARA/Disconnect terminals, fuse blocks, 40 fuses, relays on square bars etc. including fixing of PVC coated string rods at the back side for cable support with contractor's own material like iron angle, nuts, bolts etc. The iron angle for fixing shall be minimum 3 mm thick. This also includes fixing of teak wood shelf minimum 25 mm thick for holding track circuit equipments. The work shall be done as per instructions of Rly engineer at site. (Apparatus case Full)

280

4478

1253974.4

... More
Fabrication and fixing of phenolic laminated sheet of grade P3, minimum 10 mm thick,as per Apparatus case diagram/plan, in location box by providing all fixtures like ARA/Disconnect terminals, fuse blocks, 41 fuses, relays on square bars etc. including fixing of PVC coated string rods at the back side for cable support with contractor's own material like iron angle, nuts, bolts etc. The iron angle for fixing shall be minimum 3 mm thick. This also includes fixing of teak wood shelf minimum 25 mm thick for holding track circuit equipments. The work shall be done as per instructions of Rly engineer at site. (Apparatus case Half)

80

2429

194343.2

... More
Supply of ARA Terminal Block made of PBT as per Drg No SA 23741 alt 3 & spec. No IRS S 75/91 with latest amendments with disconnecting links as per Drg no. RST/11336.

22000

119

2625040

... More
Supply of Disconnect Terminal block for four conductors with screwing cage/clamp type, sliding 43 switch disconnect, as per RDSO spec. RDSO/SPN/189/2004 Ver. 3.0 or latest, for each conductor size up to 2.5 sq. mm, equivalent of M6 terminals. Each terminal block equipped with two markers, on top and bottom, an end plate, two end clamps and adequate lenght of rails for fitting terminal blocks.

20000

192

3856200

... More
Supply of Medium class GI pipes 100 mm dia (4.5 mm thickness) with thread collars as per IS 1239 44 (Part 1) 2004 or latest with coupling on culverts/bridges, perforated at a distance of 20 cm or less with 10 mm dia hole, or at any other locations as decided by Site Engineer. It includes supply of all material required for fixing arrangement. Contractor will also supply flexible/corrugated HDPE pipe at the end of GI pipe to protect the cables from sharp edges and sudden bends.

1000

991

991760

... More
Supply of Double Walled Corrugated (DWC) Pipe/duct with associated collars etc. as per RDSO Specification No. RDSO/SPN/204/2011 or latest anti-rodent & anti-oxidant and non flame propagating type in 6 45 meters straight length and of size 120 mm outer dia,& 103.5 mm inner dia. (The manufacturers, suppliers must produce valid IS license and should be certified under ISO 9000 and shall submit copy of certificate). One coupler with suitable rubber O-ring should be supplied with every 6m of pipe length. (The total quantity of above items is equal to no. of pipes supplied.) DWC pipe shall be marked at every 1 mtr length in such a way that manufacturer's name, vendor name and year of manufacture can be easily identified.

4000

656

2626360

... More
Supply and installation of earth electrode as per standard practice and as per NCR Drawing no. S&T/CONST/6.4/97. It includes supply of GI pipe of 3m length. It includes connecting the earth electrode to the equipments which are required to be earthed including digging of earth pit 3 mtr deep and fixing earth electrode 46 pipe, casting of cement concrete enclosure with cover (cover as per drawing no. S&T/CONST/6.3/97. It includes installation of 7 strand GI wires as earth lead wires, supported on MS flat size 5mm x 40 mm, soldering and nut bolt both, one end of both earth lead wire and MS flat to earth electrode and other end to Location boxes, block equipments, power equipments, cable sheath, signals etc. as per site requirement and as per instructions given by engineer incharge.

540

3450

1863518.4

... More
Supply, Installation, Testing & Commissioning of Microprocessor based Networkable analog addressable and modular type of fire Alarm Control panel with display with 2 loop expandable up to four loop, 48 power supply and battery back up as per RDSO specification no. RDSO/SPN/217/2021 ver 3.0 or latest, including GSM module-01 No. for sending SMS to configured mobile number and relay module-02 Nos. for connecting to data logger for remote monitoring. The panel should support sufficient devices of both detectors and modules in a single line circuit.

7

100285

702000.11

... More
Supply, Installation, Testing & Commissioning of Addressable heat & smoke Multi sensor (as per RDSO Specification No. RDSO/SPN/217/2021 ver 3.0 or latest.)

84

3133

263213.16

... More
Supply, Installation, Testing & Commissioning of Analogue Addressable & resettable Manual Call Point with inbuilt short circuit fault isolator (as per RDSO Specification No. RDSO/SPN/217/2021 ver 3.0 or latest.)

14

4303

60252.08

... More
Supply,Installation,Testing & Commissioning of Aspiration Systems with single pipe slot along with required module and power supply, interfacing module etc.(as per RDSO Specification No. RDSO/SPN/217/2021 ver 3.0 or latest)

7

290878

2036147.12

... More
CPVC Pipe and all other associated fittings.(as per RDSO Specification No. RDSO/SPN/217/2021 ver 3.0 or latest.)

210

1180

247825.2

... More
Supply,Installation,Testing & Commissioning of Hooter cum Strobe including its control module.(as per RDSO Specification No. RDSO/SPN/217/2021 ver 3.0 or latest.

7

7748

54238.38

... More
Supply,Installation,Testing & Commissioning of Fire survival cable 2C X 1.5 Sqmm(unarmored), (as per RDSO Specification No. RDSO/SPN/217/2021 ver 3.0 or latest.)

700

113

79373

... More
Supply, installation, testing and commissioning analog LHS cable.(as per RDSO Specification No. RDSO/SPN/217/2021 ver 3.0 or latest.)

210

1084

227713.5

... More
Supply, installation, testing and commissioning of LHS interface module for LHS connectivity to control panel. (as per RDSO Specification No. RDSO/SPN/217/2021 ver 3.0 or latest.)

7

82951

580657.07

... More
Supply of CO2 type fire extinguisher capacity 4.5 Kg capacity ISI marked, with all accessories, 57 operating temperature (-30) ° to (50) ° for class 13 B type of fire with 1 mtr. long hose pipe fitted with PVC bend horn, with carying handle and wall mounting brcket, complete in all respect. It should conform to IS 2878:2004. Extinguisher certificate has to be supplied along with the item.

28

5179

145034.68

... More
Supply of Chair, superior quality, size 57D x 58W x 88H and seat height 45 mm, make CH- 7(Godrej) or of similar reputed make.

42

2993

125744.64

... More
Supply of Chair model PCH-7001 of Godrej make or of similar reputed make.

16

11174

178792.8

... More
Supply of Antistatic mats of size 1 mtr x 0.75 mtr and 3 mm thickness.

96

2009

192958.08

... More
Supply of thermo shrink jointing kit as per RDSO Specn.No. IRS: TC 77-2012 (Rev.3.0) with (Amdt.- 1 to 3) or latest, suitable for 6 Quad/jelly filled cables for straight through/derivation joints. It includes supply of all the accessories, without transformer

30

3361

100857.6

... More
Supply of VF Transformers, rack mounting type, 600:470 Ohms as per RDSO Speen.No. IRS: TC- 22/76 or latest.

40

1501

60075.2

... More
Supply of screened 5 pair (10 core) color coded and twisted Data Communication Cable, each core made of Copper Conductor of 0.20 mm diameter(7/0.20mm) ABC (Annealed Bare Copper) & Polyethylene Insulated. Tolerance in dimensions should be within ± 10%.

1000

65

65670

... More
Supply of permanently lubricated HDPE duct, 40 mm outer dia, as per RDSO spec. No. RDSO/SPN/TC/45/2013 Rev.2 Amndt.2 or latest, along with all accessories like end caps, collars, bends, couplers etc.

5

76811

384057.1

... More
Supply, Installation and commissioning of active lightning arrestor of Class 'A' for building protection as per statndard NFC-17-102 :2011 or latest. It shall work on early streamer emission principle. It shall be made of 67 stainless steel with an opearting time of 60 microsecond or less. A non-resettable counter shall be provided to count the number of lightning occurences. The device shall be installed on top of the building on a GI mast and shall be connected to the earth pit through a copper tape of 25mm x 2mm or better. The copper tape shall not touch the building throughout and shall be connected to the earth electrode by exothermic welding.

7

111652

781565.68

... More
Supply and installation of 20 pair CT box with disconnection facility, made of FRP.

32

2212

70797.12

... More
Installation wiring testing and commissioning of Fuse auto change over system. This includes 69 provision of common Buzzer & indication at ASM Room & ESM Duty Room and painting of fuse details. This also includes fabrication of frame for installation of FACS at Station/ LC gate where installation of relay racks not feasible. One set means set of each fuse..

1600

159

255632

... More
Fixing, wiring, testing and commissioning of Electrical Point Machine on the Wooden/PRC sleepers at points as per standard practice and as per section of rails used. Item includes fixing switch extension bracket, providing insulation for switch extension bracket, fixing ground connection, adjusting opening of the switches and adjusting the point machine with crank handle.The item also includes : (i)Complete material for installation like ground-connections, switch extension brackets, point insulation material, I pipes, wiring materials, various fixing nuts & bolts including castle nuts, spring washers (ii) All smithy & fitting works required at site for complete 70 installation. (iii) Installation of gauge tie plate & providing insulation for gauge tie plate (Insulation in William Stretcher Bar will be provided by Railways). (iv) Wiring inside the point machine, insertion and termination of tail cable in point machine and junction boxes / location box /cable hut as per extent practice on NCR and the instruction of Railway Engineer at site. (v) Supply and fixing of bend pipes with welded frame for cable entry to machine (vi) Supply and filling of industrial grade/good quality lubricant/grease/oil for smooth opertion of point machine Note ; The ground connections shall be suitable to the Point Machines as specified by Engineer-in- charge and shall be suitable to the point lay out i.e. 60 Kg. / 52 Kg / 90R as per yard layout. Electrical Point Machine and M-6 / Screw less terminals will be supplied by Railways / covered in Schedule separately

98

14054

1377311.6

... More
Installation of DC track circuits (Point zone) including supply of materials as per directive of site Engineer. NOTE : (i) This includes drilling 9/32" holes on rails, provision of double continuity GI wire bonding, provision of Block Joints 60 Kg/52 Kg/90R with machined fish plates, installation of Track lead junction box (separately for (+) and (-) rails), provision of track lead jumper wires/cables, fixing of track circuit equipment i.e. track charger, resistance, fuses, batteries, chokes, relays, anti-titling arranginment and painting, lettering and 72 numbering of DC track circuit equipments etc., (ii) [a] Un-machined fish plates shall be supplied by the Railway's, but machining of fish plates shall be done by the Tenderer. In case of provision of Glued Joints by Engineering Department in lieu of RDSO Block joint, the cost of machining of fish plates@ 100/- per straight track circuit and @ 500/- per point zone track circuit will be deducted. [b] This includes insulation of gauge tie plates, Crossing plates, rod in siding points if required or any other place as instructed by Railway Site Engineer, by Tenderer's insulation materials. Railway will supply Track Charger, B-type choke, Resistance, Un-charged battery, TLJB and relays through a separate schedule/from the stores of railway consignee. These are to be transported to site of work at contractor's cost. Tenderer/Contractor shall supply any other materials that are required for the work.

104

12472

1297101.52

... More
Charging of Lead Acid Batteries, 2V, 80 AH, with contractors own battery grade sulphuric acid and 73 distilled water with minimum two charge - discharge cycles, installation of charged batteries in groups & their connection & wiring. The work shall be done as per the procedure prescribed by the OEM and extant practice of N.C.Rly and instruction of Engineer-in-charge. Detailed measurements of initial charging shall be recorded jointly by contractor & Rly's site-in-charge

570

247

140943.9

... More
Casting, concreting and curing of foundation for Main Signal Post in the ratio of 1:3:6 as per NCR drg.No. TYP/013/14/SIG FOUND. dtd 12.11.2014 (total 2 sheets of drawing) issued vide NCR Letter no. 74 S&T/NCR/DRG/TYP dated 13.11.2014, using standard size of foundation/galvanized anchor bolts complete, required for erection of colour light signal post. Anchor bolts complete should comply with the RDSO drg. no. SA 116 A/M. Item includes excavation, ramming of CC using vibrator, curing and plastering with 1:4 cement-sand mixture (aggregate will not exceed 3.8 cm). Aggregate, cement, sand and holding down bolts will be supplied by contractor. Any machines & tools, if required for execution of this item, will be arranged/provided by contractor

104

13512

1405292.72

... More
Casting, concreting and curing of foundation for Position Light Shunt Signal as per Drg.No.NR/S&T/Const/2.2/97 using standard size of foundation/galvanized anchor bolts complete, required for 75 erection of shunt signal post. Anchor bolts complete should comply with the RDSO drg. no. SA 116 A/M. Item includes excavation, ramming of CC using vibrator, curing and plastering with 1:4 cement sand mixture. Aggregate cement, sand and holding down bolts, will be supplied by contractor. Any machines and tools, if required for execution of this item, will be arranged/provided by contractor.

30

3670

110109.9

... More
Erection of CLS Post with base and signal unit on top or on Offset Bracket including erection of auxiliary signals like calling on, shunt signal if any. It includes fixing of all LEDs and wiring of complete signal 76 including route and auxilliary signals, if any. It includes fixing of front and back staging, ladder and guards, signal name plates / boards, with contractor's own brackets and fixing materials. The work shall be done as per instructions of Rly engineer at site. It also includes provision & fixing of maintenance platform as per design given by Engineer -In-Charge at site. The Item includes cutting of Signal post if required by Site In charge.

98

5881

576379.16

... More
Erection of Position Light Shunt signal with Base, Post, Signal unit, complete fixing of LEDs and wiring of full signal. It includes fixing of Number Plates. The work shall be done as per instructions of Rly engineer at site.

30

951

28544.4

... More
Fixing of Junction type Route Indicator on top of signal post and complete wiring, 1-Way/2-Way/3- Way/4-Way/5-Way/6-Way/theater type.

16

1112

17800.16

... More
Dismantling and Releasing of existing Signals (both electrical and Mechanical) and other associated S&T fittings like wheel, pulleys, wires, stakes etc. All the released material will be transported to the SSE/Consignee depot.

10

1529

15297

... More
Excavation, casting, curing of foundation and Installation and Erection of Apparatus case Full (App. 80 Case as per RDSO drg. no. RDSO/S-11500 or latest) with contractor's own frame, cement and other material in the ratio 1:3:6. 'E' type lock to be supplied and installed with App. case.This includes filling of location foundations with river bed sand and plastering on top with a mixture of 1:4 of cement and sand. It covers supply & fixing of lamp holder, switch and lamp etc. in Apparatus Case.

280

12277

3437786.8

... More
Excavation, casting, curing of foundation and Installation and Erection of Apparatus case Half (App. 81 Case as per RDSO drg. no. RDSO/S-11507 or latest) with contractor's own frame, cement and other material in the ratio 1:3:6.'E' type lock to be supplied and installed with App. case.This includes filling of location foundations with river bed sand and plastering on top with a mixture of 1:4 of cement and sand. It covers supply & fixing of lamp holder, switch and lamp etc. in Apparatus Case.

80

10332

826577.6

... More
Fixing of ARA(M-6) Terminals /Screw less connectors / modular disconnect terminal blocks and 82 fuse blocks on phenolic laminated sheets and fixing by stainless steel/brass nuts & bolts. This includes provision of two additional holes on the board on either side for cable conductor entry. The work shall be carried out a per instructions of railway Engineer incharge.(Supply of all above terminals has been covered separately). Per

64000

18

1159040

... More
Dismantling and Releasing of existing Location boxes/Apparatus cases/Jn boxes and other associated S&T fittings. All the released material will be transported to the SSE/Consignee depot.

20

972

19441.6

... More
Cutting of all types of platforms/road crossing and trenching and excavation to a width and depth of 300 mm x 300 mm, laying of DWC/HDPE/GI pipe in the trench and refilling and concreting it afterwards as per 85 original condition. In hard rocky ground area , cables will be laid normally on layer of soft earth of 0.05 mtrs thickness previously deposited at bottom of the trench . The cutting to be filled and finished with cement/concrete, as per the RDSO drawing no.SDO/Cable laying/008, issued vide RDSO document no. RDSO/SI/G/2010 Version 1.1 dated 04.02.2014 or latest.

2000

158

317760

... More
Excavation of cable trench as per cable route plan, 1.2 Mtr. deep and of 0.3 Mtr. to 0.6 Mtr. wide at of bottom as per RDSO sketch No. SDO/CABLE LAYING/003, issued vide RDSO document No. RDSO/SIG/2010 ersion .1 dated 04.02.2014 or latest, alongside the track in normal (all type) soil/ strata, conforming to distances as 86 per cable route plan and refling and ramming of loose soil. This work includes clearing of route from bushes ete,covering of cable laid in trench by loose soil for of a layer of 50mm thickness approximately before covering by bricks,. The work shall be done as per the extant practice on North Central Railway and instructions of Railway Engineer at site. In case 1.2m depth of trench is not achievable due to site conditions, specific approval of JAG/SG Officer will be required for each site where trench depth of 1.2m is not possible, only after approval of JAG/SG Officer proportionate payment can be done.

45000

87

3949650

... More
Laying of S&T Cables of various cores/ pairs/ quads in trenches/ GI pipes/ RCC pipes/ DWC pipes 87 etc. as per the site requirement and as per approved cable route plan. This also includes laying of cables in track crossings & road crossings.(Cables will be meggered before and after its laying by contractor under supervision of Railway Representative and he will submit the meggering report of each testing). Length of the cable laid includes the length of the cable coiled for termination purpose

700000

6

4788000

... More
Cross trench for identification of the route of existing signlalling and telecomm cables.

50

290

14521

... More
Laying and fixing of Medium class GI pipes 100 mm dia (4.5 mm thickness) as per IS 1239 ( Part 1) 2004 or latest with coupling on culverts/bridges, perforated at a distance of 20 cm or less with 10 mm dia hole, or 90 at any other locations as decided by Site Engineer.The GI pipe is to be filled with chattered compound. It includes supply of all material required for fixing arrangement. Contractor will also supply flexible/corrugated HDPE pipe at the end of GI pipe to protect the cables from sharp edges and sudden bends. The laying and fixing to be done as per RDSO drawings no. SDO/cable laying/011 and SDO/cable laying/012, issued vide RDSO document no. RDSO/SI/G/2010 Version 1.1 dated 04.02.2014, or latest

1000

354

354300

... More
Cement concrete work for miscellaneous, unscheduled items in ratio 1:3:6 of cement, coarse, sand 91 and aggregate Item includes excavation, ramming of CC by using vibrator, curing and plastering with cement and sand mixture in ratio 1:4 (aggregate will not exceed beyond 3.8 cm). The aggregate cement and sand will be supplied by contractor.

200

5109

1021924

... More
Supplying and placing of one layer of quality bricks of standard size and of 'B' grade of the local 92 make and spreading on cables laid.(minimum size of brick 200mm X 100mm X 70mm)Proportionate payment on the basis of volume of bricks can be paid in case the size of the bricks supplied differs slightly from the standard size.

96000

4

414720

... More
Loading, Transportation/Carriage and Unloading of various S&T material by a 9 MT truck, from/to the consignee depot to/from various locations, as decided by the Railways.

30000

54

1639500

... More
Installation of Antistatic mats of size 1 mtr x 0.75 mtr and 3 mm thickness.

96

148

14217.6

... More
Painting of two coats of Enamel paint over one coat of Red Oxide primer after scrapping and cleaning of the surface. Paint to be of reputed make Asian/Dulux/Berger or similar.App. Cases inside and outside to be done by Silver colour. (Apparatus Case Full)

280

681

190946

... More
Painting of two coats of Enamel paint over one coat of Red Oxide primer after scrapping and cleaning of the surface. Paint to be of reputed make Asian/Dulux/Berger or similar.App. Cases inside and outside to be done by Silver colour. (Apparatus Case Half)

80

620

49614.4

... More
Painting of two coats of Enamel paint over one coat of Red Oxide primer after scrapping and cleaning of the surface. Paint to be of reputed make Asian/Dulux/Berger or similar. (Main Signal post, base, unit and complete fittings)

98

914

89617.08

... More
Painting of two coats of Enamel paint over one coat of Red Oxide primer after scrapping and cleaning of the surface. Paint to be of reputed make Asian/Dulux/Berger or similar. (Shunt Signal post, base, unit and complete fittings)

30

389

11698.5

... More
Painting of two coats of Enamel paint over one coat of Red Oxide primer after scrapping and cleaning of the surface. Paint to be of reputed make Asian/Dulux/Berger or similar. (Point machine and ground connections, Point machine by Black enamel and ground connection by Red oxide)

94

288

27119.94

... More
Lettering and Numbering of all S&T gears like Signals, Loc. Boxes, Pt. Machines, TLJBs, Block joints etc. Each item to be taken as one unit.

1200

85

102696

... More
Installation of Unit Maintenance Free Earth to achieve a resistance less than 1 ohm as supplied under item no. 13002 of Chapter 13 of SOR. It includes (i) Digging the earth to the required depth. (ii) Insertion of electrode. (iii) Filling of earth enhancing compound (Approx.30 Kg) (iv) Provision of exothermic weld connections to copper tape of 25 mm x 6 mm x 150 mm to the earth electrodes. All material tools and features required for 101 weld will be arranged by contractor. (v) This also includes CC cover 1.5 ft x 1.5 ft. 1 ft wall thickness 2 inch with cover 3 inch thickness. Cables 35 Sq mm/ 16 Sq mm/10 sq mm for connecting earth to busbar, busbar to busbar and busbars to various equipments. Earth electrode of 17.20 mm dia and 3.00 meter long high tensile low carbon steel circular rods molecularly bonded with copper and outer surface (minimum copper bonding thickness of 250 micrones to made requirement of under writer's laboratories (UL) 467-2007 or latest. Copper strips of 150 mm x 25 mm x 6 mm to be welded with each earth electrode, copper strips of 300 mm x 25 mm x 6 mm for main equip- potential busbar, copper strips of 150 mm x 25 mm x 6 mm sub equip-potential busbar in relay room, power room and panel room. GI strip 25 mm x 2 mm for ring formation of earth pits Earth enhancement material in bags for each Earth Electrode. Inspection chamber of site 300 mm x 300 mm x 300 mm (Inside dimension) of approximate 50 mm thick with pulling hooks to cover the earth pits. Note: The installation of this item shall be carried out by the contractor as per RDSO Specn.No.RDSO/SPN/ 197 Ver 1.0 or latest. Typical RDSO approved drawings referred in the RDSO specification document are : (i) SDO/RDSO/E&B/001 for typical installation of Earth, (ii) SDO/RDSO/E&B/002 for typical bondong and earthing connections, (iii) SDO/RDSO/E&B/003 for typical arrangement for earth resistance measurements.

46

7276

334741.54

... More
Installation of thermo shrink jointing kit as per RDSO Specn.No. IRS: TC 77-2012 (Rev.3.0) with (Amdt.-1 to 3) or latest, suitable for 6 Quad/jelly filled cables for straight through/derivation joints. It includes supply of all the accessories, without transformer

30

1682

50486.1

... More
Supply, Installation, Testing and Commissioning of High Availability Single Section digital axle counter (HASSDAC) with Dual sensor system as per RDSO/ SPN/177/2012 (Version 3) or latest. Th is includes the supply of High frequency web mounting type Tx coil/Rx coil, VR/PR Box duly wired, Vital relays, PR Relays, Clamp with defl ector plates & hardware, Dual display reset box/monitoring console with auto resetting facility, Surge 103 voltage protection devices and fi lter card to be mounted on DIN rail etc as per OEM for complete installation & testing & commissioning of (HASSDAC) system. Th is include fi xing of track device, relays, wiring, lacing /dressing, cable termination with lug eyelet, drilling holes in rails, Installation of track devices and make it functional along with existing UFSBI/block instrument. Material required other then supply item of HASSDAC shall be arranged by contactor to make it functional. Note: One set of HASSDAC system will include equipment required to monitor One Up line or One Dn line of a full Block Section between two stations.

10

732954

7329544.8

... More
Installation, testing and commissioning of Micro Processor based Data Logger System with 512 digital inputs and 32 analog inputs with protocol converter as per RDSO Spec. No. IRS (S) 99/2006 (Amnd. 3) or latest. It includes supply of all the items required for complete indoor relay room wiring from data logger to relay 104 rack tag blocks, drawing/extension of power supply upto Data Logger. It includes relay room door lock checking arrangement, commercial power supply monitoring arrangement & monitoring of DG sets, ELD , IPS, UFSBI, BI, interlinking and networking of Data logger. It also includes installation of leased line MODEM and other interfacing cards, if required for networking of Data Logger. Note: Total numbers of relays and other signalling functions/gears required to be wired as per list circulated vide RDSO Letter No. STS/E/Data logger dtd.12.09.2011 or latest guidelines.

7

66000

462000

... More
Supply of Electrically Operated Lifting Barrier complete set suitable for 110V AC/DC supply, without hand generator back up, and motorized boom locking arrangements as per RDSO Spec. SPN/208/2012 Ver. 2.0 or latest. The 02 Nos of Barriers of length 09.76 Mtrs. should be supplied along with stop boards and light. The 105 spares & tool kit mentioned in RDSO Spec. no. RDSO/SPN/208/2012 Ver. 2.0 and Amndt. 1 or latest,clause 10.1 & 10.2 reproduced as below should be supplied along with each full set :- i) GI boom - 1 no. complete. ii) Belt - 1 no. iii) Crank handle - 1 no. iv) Motor Contactor - 1 no. v) Motor protection MCB- 1 no. vi) Push button complete- 2 nos. vii) Limit switch - 3 nos. (1 lever type and 2 top roller type) viii) Fuses used - 2 sets Tool kit consisting of standard sizes of wrinch/ spanner and Allen keys should also be supplied with each set (02 nos.) of Electric Lifting barrier.

5

362897

1814488.25

... More
Installation, testing and commissioning of electrically operated lifting barrier, complete with casting of cement concrete foundation for pedestal and boom rest post, cabling, power supply connection, earthing of barriers & wiring with complete outdoor work as per approved drawing, wiring etc.

4

55688

222754.48

... More
Supply, Installation,testing and commissioning of Sliding type mechanical Boom barrier (SBB) assembly, 11 to 12 Meter Long, movement drive mechanism, resetting & supporting stand suitable for 107 Mechanical/Electrical level crossing gate as an emergency arrangements as per GZB Workshop drawing no. SA- SWG/GZB/E/01. The sliding boom assembly should be have the provision of 50mmx50mmx50mm angles for the entire length. Boom rest posts should be 10 no per gate or more as per site requirement. Painting should be completely done of all the assemblies/parts of Sliding LC gate.

4

189475

757903.84

... More
Supply of Desk type Electronic Magneto telephone as per spec. No. IRS TC: 79/2000 (Amndt.4) or latest.

64

3524

225599.36

... More
Supply, Installation, testing and commissioning of Block Panel BPAC(Block Proving with digital axle 109 counter) using UFSBI as per specification IRS:S-105/2012 (Ver.0) with latest amendment for single line operation.NOTE: One set will include all equipments viz. SM panel, block telephone-2 no, pre-wired relay rack-2 no, all types of required relays, surge and lightning protection, technical manuals etc. required for one complete Single line Block Section (except DAC).

8

959857

7678859.84

... More
Supply, wiring, installation and commissioning of Earth Leakage Detector (ELD) having 6 digit 110 counter, 12 Channel bus bar, voltage of 110V/60V/24V/12V in AC/DC measurement as per RDSO Spec. RDSO/SPN/256/2002 or latest. This includes supply of fuse terminal strip for incoming power supply wires. Installation to be done on 19 inch sub rack along with insulation resistance meter, remote indication and buzzer in ASM room.

8

175512

1404102.88

... More
Supply of Non deteriorating type, Round head type, low voltage cartridge fuse as per Spec No IRS: S -78/92 with latest amendments, 2A/4A/6A/8A/10A/16A rating capacity.

4000

123

492800

... More
Supply of Cartridge Fuse block, made of PBT, as per RDSO spec. No. IRS: S-75/2006 (Rev.2) or latest and as per Drawing. No. SA- 23748 (Alt.-4) or latest.

400

243

97464

... More
Supply of Insulation resistance tester, 100 Mega ohms, 500V DC, hand generator type. Make Meco/Motwane/Waco or similar.

3

17830

53492.04

... More
Supply of UTP CAT-6 cable of reputed make Siemen/ Systemax / D-Link/ Tyco/ Krone/ AMP or similar.

1500

22

33540

... More
Supply of Insulation resistance tester, 10 Mega ohms, 100V DC, hand generator type. Make Meco/Motwane/Waco or similar.

3

15692

47076.03

... More
Supply of 1 x 25 Sqmm (Red/Black/Green) multi strand copper power wire, Colour of the wire which is required will be specified by the Engineer incharge.

2000

398

796340

... More
Supply of Electric Point Machine 143 mm stroke, AC Immunity 160V AC, complete with lock detector and slides for lock detector,Non-trailable,to operate on 110V DC, rotary locking with crank handle universal type as per RDSO Spec. No. IRS:S-24/2002 (Amnd. 1) or latest, RDSO DRG. NO S-10800 (ALT.5) WITH JUNCTION BOX TELESCOPIC. THE MOTOR WILL BE AS PER RDSO SPECN. NO. IRS: S-37/82 (AMND. 3) WITH RDSO DRG. NO. S-10910. This includes supply of Set of tools as per para 20.1 & 20.2 of RDSO SPECN. NO. IRS:S-24/2002 117 (AMND 1) The following set of tools in a suitable tool box shall be supplied along with every set of eight point machines or less. i). Hand operated square drive socket wrenches of 12.5 mm driving square (short type) as per IS: 7381 for M8, M10, M12 & M18 threads. (One 250 mm long 12.5 mm square extension bar as per IS: 7991 alongwith compatible Tee handle Square drive as per IS: 7975 suitable for above socket wrenches shall also be provided.) ii). Open jaw wrenches (spanners) for M10, M12, M20, M24 & M33 threads as per IS: 2028. iii). Adjustable wrench. iv). Screw driver 300 mm long. 2 Junction box and two numbers of telescopic pipes of approved type shall be supplied as an integral part of the point machine.

98

100448

9843928.5

... More
Supply of Steel stool, 1 ft by 1 ft size, 1.5 ft height, laminated top.

16

1267

20276.16

... More
Transportation of less/heavymaterial and manpower includingsupply & running of one MUV to thesites of work as per requirement &direction of site incharge along withdriver. The rate includes all taxes,licence fee, road permit, driverwages, fuel, repair & maintenancecost etc. complete in all respect.

90000

31

2793600

... More
Transporation of HDT machine with accessories including handing of stores materials preparation 2 of site and boring for placing and supply of one number 110 mm dia HDPE pipe for crossing of S&T cables together at bridges/culverts track pucca road crossing boring trench shall be 3 Mtr below the river bed and 1 mtr below the track/road/pucca road crossing area. this incudes supply of accessories for HDPE pipes cost of fuel and all other items which will be required for laying of cables through it. The work shall be executed as per instruction of site engineer. The rate includes laying of cable through the pipe laid by HDT machine boring upto the length of 150mtrs.

2000

1521

3043860

... More
Installation of integrated power supply equipments grouting, laddering, wiring & interconnections of 3 power panel, power equipments, programme swiches, busbars fitted on relay racks outgoing supply terminals on CT racks. All the power wires should be terminated with copper lugs (Dowells or similar make) and soldered with contractor's own materials.

8

35937

287498.48

... More
Supply of PWM Based online Inverter with 24 or 110V DC input and 230V AC output 500VA capacity for signaling purpose as per RDSO specification no. IRS:S:82/92 with AMD.2 or latest

16

41000

656000

... More
Supply, installation, testing & commissioning of automatic media change over device for dac/msdac v.21/v.23 to optical fibre, STM (E1) standard 19" rack mountable device consisting of two E1 port supporting 120 ohms interface, dual optical ports with (1+1) hot stand by (dual core path and single core path ) 20 kms driving distance and four v.21/v.23 (e&m) interface (04 ports (04 e&m + 04 quad) ) 2w/4w interfaces with auto change 5 over mechanism to quad ports 2w/4w. Each port configurable as 2w or 4w no restriction in configuration. Unit to support potential free contacts four numbers can be linked with data logger / RTU for e1 status , quad status & power supply status, unit support front panel ressetable audiable buzzer in case of main link fails (optical or e1) unit to support power off fail safe mechanism when the unit is switched off the inputs is by passed to the quad cable automatically unit supports front panel led indicators for quad health status; e1 dual, optical dual path, dual dc power supply 18 vdc to 72 vdc range: make: Team engg/Cygnus/lantana/waves/fabio1cx-4p or similar reputed make.

10

153400

1534000

... More
Supply of U- plain storage almirah with 4-adjustable shelf of Godrej make.

16

20994

335906.08

... More
Supply of Electric point machine rotary locking type, High thrust 220 mm Throw, AC immunity 160 V AC, non trailable to operate on 110V DC completed with lock detector slides, Cable termination Box as per RDSO specification No.IRS: S:24/2002 amendment 1 or latest as per Drg. No. RDSO/S-11000 and RDSO/S-3395. The point machine and Ground connections are as per Drawing No. mentioned in RDSO's letter No. TS/E/PM/ 220 mm Vol-1 dated 23.5.2019. Ground connection shall be as per RDSO Drawing No. RDSO/S-3454 Alt.-A consisting of (i) 1 in 12 turn outs BG 60 kg on prestressed concrete sleepers fitted with IRS point machine ( 220 mm throw) for 7 independent switch locking and clamp point lock (160 mm throw of point) with P-bracket as per Drawing no. RDSO/S-3454 Alt.-A (ii) Facing point BG switch extension bracket/insulation plate left hand and Right hand as per drawing no. RDSO/S 3591-3592-3593 (iii) Facing point BG detector rod far end/near end as per drawing no.RDSO/S-3594-95 (iv) Facing point BG lock rod far end /near end as per drawing no. RDSO/S-3596-97 (v) detector rod lug and lock rod lug as per drawing No. RDSO/S-3598 (vi) Special MS plate for S&T fittings on PSC sleepers as per drawing No. RDSO/T-3901 (vii) clamp type lock 60KG (TWS)-BG-bolt special head as per drawing no. RDSO/S/3599 latest alteration if any are applicable. One set of tools in a suitable tool box shall be supplied along with every 5 nos. of point machines consisting of (i) M6/M8/M18/M22/M20 box spanners (ii) M10/12 spanners (iii) Adjustable wrench (iv) screwdriver 300 mm long. It includes insulation material also.

10

122130

1221300

... More
Supply of Desktop Client Machine (AIO), Minimum Specifications, Core i5 12TH GEN / 8GB DDR4 RAM / 1 TB SSD / WIN 11/MS office with Full HD monitor min 23 Inch, UPS , One chair and One computer table for Data logger display of signals.

8

108088

864705.6

... More
Supply of multifunction all in one A-4 Printer for printing of fault andexception report from data logger.Make and Model shall be got approved from Railway before supply

8

25976

207812.88

... More
Supply of PVC indoor cable 1x40x0.6 mm dia colour coding of insulation of innercore shall be in eight colours viz Blue,Red, Grey, Green, Brown, Block, Yellow &White as per specn IRS S 76/89 (Amd.-3)or with latest .

1

135506

135506.98

... More
Supply of PVC indoor cable 1x60x0.6 mm dia colour coding of insulation of innercore shall be in six colours viz Blue,Red,Green, Grey, Brown, & Black as perspecn IRS S 76/89 (Amd.-3) or withlatest.

2

153264

306529.2

... More
Supply of Handheld Digital InsulationTester with separate ranges of 50 V, 100V, 250 V, 500 V, 1000V with additionalfeature of multi metering of voltagecontinuity and low resistance model No.I12 MOTWANE make or similar

4

16407

65629.32

... More
Development and preparation of SIP (Phase) Layout based on existing SIP/ ESP . The contractor shall initially supply Tentative SIP for approval of railway. After approval of SIP, final tracing with 8 set of Ammonia/white print to be provided.

6

37967

227805.6

... More
Preparation of SWRD (Phase) based on SIP for EI. After approval of SWRD final tracing with 8 set of ammonia/white print of SWRD to be supplied.

6

15187

91122.24

... More
Preparation of Station working Rule (SWR) for phase/final working in English and Hindi of station 16 based on SWRD of the station. The contractor shall initially supply 2 copies of complete SWR for approval of railway. Railway will return one set of SWR duly approved. Final SWR after doing all corrections and complete in all respect along with 8 set of SWR and final CD to submit to Railway. 1 No. = 1 SWR (Hindi OR English).

14

8124

113749.44

... More
Supply of Dual E1 Converter as per specifications. (i) Features: DTE side-Asynchronous (RS232); DCE Side- 4 wire E1 communications (G.703) Line speed 2.048 Mbps; 2 nos. DTE ports and 2 nos. DCE ports; Line impedence-120 ohm balanced; LED indications- Power, E1 sync, Test, error, TD, RD and health; Inbuilt BERT tester; supports Remote loop and local loop back tests for diagnostic purpose. (ii) E1 Interface: Standards 17 compliance- ITU-T G.703; E1 transceiver chipset should comply ITU-T G.736 and G.823; Interface Rate- 2.048 Mbps+-50ppm; Line coding-HDB3; Line isolation - 1500V (RMS); (iii) RS-232 port: Standards compliance-EIA RS 232C; Interface types-RS 232; Signal-TXD,RXD,GND; Baud rate- upto 57600 bps (autobaud); Asynchronous serial. (iv) Electrical and mechanical: Input voltage-5V DC; Power consumptionless than 2W; operating temperature -10deg Cent. to +70 deg. cent; Storage temperature -10 deg cent. to +70 deg. cent; Eurorack insertable.

10

35502

355027.4



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.