North Central Railway Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

North Central Railway - NCR Tender

Works
Electrical Goods and Equipments
Electrical and Electronics
Ireps
Opening Date26 Dec 2024
Closing Date21 Jan 2025
Tender Amount₹ 1,84,61,211 
Notes
Download

Costs

Summary

Ei Alteration Work In Connection With Provision Of Additional Line At Sank Goods Shed And Bhind Goods Shed In Jhansi Division Of Ncr.

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
"Q-Series Line Relay (QNA1 Type),AC immunized, 8F/8B, 24 V DC along with plug board 4 (base plate), connectors, retaining clips etc and conforming to BRS-931A and RDSO Specn.No.IRS:S@ 45"44@ S-23 , S@ 45<10@or latest, a s applicable. The interlocking code for this unit shall be ""ABDGH""." (Inspection Agency By RDSO)

10

4456

44568.5

... More
Q-Series Track Relay (QTA2 Type), AC immunized, 9 Ohms, 2F/1B along with plug 5 board (base plate), connectors, retaining clips etc and conforming to BRS:939A & 966(Appendix F2) or latest and RDSO Specn.No.IRS:S@ 45"44@ S-23 , S-60 or latest, as applicable.The interlocking code for this unit shall be "FGHKX". (Inspection Agency By RDSO)

10

3804

38049.8

... More
Q-Series Neutral Line Relay(QSPA1 Type), AC immunised, 24V DC,8F/4B along with plug 6 board (base plate), connectors, retaining c l ips e t c and conforming t o BRS-933A a n d RDSO Specn.No.IRS:S- 34, S-23, S 60 o r latest , as applicable.The interlocking code for this unit shall be "ABDEJ". (Inspection Agency By RDSO)

10

6059

60591.6

... More
Contactor Unit (QBCA1 Type), 24 V DC, 2HF/4B complete with plug board(base plate), connectors, retaining clips etc and conforming to BRS- 943 and RDSO Specn.No.IRS:S@ 45"44@ S-23 , S-60 or latest, as applicable.The interlocking code for this unit shall be "BCEJK". (Inspection Agency By RDSO)

14

6825

95556.58

... More
Q-Series Magnetically Latched Neutral Line Relay (QL1 Type), 11F/4B,24V DC complete 8 with plug board(base plate), connectors and retaining clips and conforming to BRS-935A and RDSO Specn.No.IRS:S@ 45"44@ S-23 o r latest, as applicable.The interlocking code for this unit shall be "ABDEG". (Inspection Agency By RDSO)

12

5985

71825.52

... More
Q-Series Magnetically Latched Neutral Line Relay (QL1 Type), 8F/6B, 24V DC complete 9 with plug board(base plate), connectors and retaining clips and conforming to BRS-935A and RDSO letter no. SGW/R.102/Q Relay dated 08.12.2016 of S&T Wksp/PTJ and RDSO Specn.No.IRS:S@ 45"44@ S-23 or latest, as applicable. The interlocking code for this unit shall be "ABCEG". (Inspection Agency By RDSO)

6

5806

34840.98

... More
Q-Series Twin Neutral Line Relay(QNN1 Type), 6F/2B, 24V D C complete with plug 10 board(base plate), connectors a n d retaining cl ips e t c and conforming t o BRS-960 a n d RDSO Specn.No.IRS:S- 34, S-23 or latest, as applicable. The interlocking code for this unit shall be "ACDEK". (Inspection Agency By RDSO)

20

5556

111124.6

... More
Supply of Key Lock Checking Relay (KLCR) working on 24V DC, AC Immunized, metal to 11 metal, with different ward combinations and contact configuration 4F/4B with 2 extra ward plates, RDSO spec no . RDSO/SPN/219/2016 Ver 1 .0 with Amendment-1 or latest. (Inspection Agency By consignee)

6

8026

48161.04

... More
Supply and installation o f prewired KLCR Box, wooden crank handle lock inside box, 12 with 8 way terminal strips, LEDs of approved type, for fixing of EKT on wooden board inside box form installating KLCRs/EKTs up to 06 no., including supply of all material like board, handle, hinges, glass sheet etc. (Inspection Agency By consignee)

4

13636

54546.08

... More
"Supply and Installation of Glass fronted Key box for Crank handle etc.It should be done as per site supervisor instructions." (Inspection Agency By consignee)

2

2459

4918.22

... More
Supply o f 16/0.2 m m (0.5 s q mm) PVC insulated multi strand, single core, tinned 14 copper conductor, as per RDSO Specn.No.IRS:S-76/89 (Amnd-3) or latest. Each coil should be of 100/200/500 meters length.Colour of the wire will be specified by the Engineer incharge. (Inspection Agency By consignee)

1000

10

10880

... More
"Supply of PVC Insulated, Indoor cable, single core, 1.0 mm, flexible, as per IRS-S-76/89 (Amndt.-3) or latest. Coil should be of different colours, each in 100 m length." (Inspection Agency By consignee)

200

7

1412

... More
"Supply o f 1 x 6 S q m m (Red/Black/Green) multi strand copper power wire , 85 16 conductor each dia 0.30 +/- 0.01 with insulation thickness of 0.8 mm and nominal conductor resistance of 3.3 ohms/km and test parameters as per RDSO Specn.No.IRS:S- 76/89 (Amnd.3) or latest.Colour of the wire will be specified by the Engineer incharge." (Inspection Agency By consignee)

1400

47

67158

... More
"Supply o f 1 x 1 0 Sqmm (Red/Black/Green) multi strand copper power wire, 101 17 conductor each dia 0.45 +/- 0.01 with insulation thickness of 1.2 mm and nominal conductor resistance of 1.127 ohms/km and test parameters as per RDSO Specn.No.IRS:S-76/89(Amnd.3) or latest.Colour of t h e wire which i s required will be specified by the Engineer incharge." (Inspection Agency By consignee)

800

125

100464

... More
"Supply of 1 x 16 Sqmm (Red/Black/Green) multi strand copper power wire as per IS: 18 2465/1984 and IS:694:2010 or latest, 101 conductor each dia 0.45 +/- 0.01 with insulation thickness of 1.2 m m and nominal conductor resistance o f 1.127 ohms/km and test parameters a s per RDSO Specn.No.IRS:S- 76/89(Amnd.3) or latest.Colour of the wire which is required will be specified by the Engineer incharge." (Inspection Agency By consignee)

800

147

118216

... More
Supply of 1 x 25 Sqmm (Red/Black/Green) multi strand copper power wire, Colour of the wire which is required will be specified by the Engineer incharge. (Inspection Agency By consignee)

400

398

159268

... More
"Supply, installation, testing and commissioning of Multi Section Digital Axle Counter 20 (MSDAC), complete system including central evaluators, processors, final track clearance relay for each track section, Reset boxes, Monitoring consoles, Diagnostic PC/Laptop of suitable configuration, LV boxes, detection points, mushroom housing for track side electronic, deflector plates and all other accessories, a s p e r RDSO'S specification N o . RDSO /SPN/176/2013 ( Ve r. 3 ) o r la test and OEM/Manufacturer's specification.(Per Detection point/DP)" (Inspection Agency By RDSO)

17

414180

7041060

... More
Supply and installation o f Cable Termination(CT) rack as per drawing of NC Railway, complete along with fitting arrangements, wall supports, scaffolding and suitable grouting 21 arrangements and also with arrangement for fixing four 8-way terminal strips/ Screw less terminals/ ARA terminals. The CT rack shall be covered with hylum sheet of minimum 10 mm thickness for fixing of 8-way terminal strips/ Screw less terminals/ ARA terminals. Supply of 8 way terminal strips/ Screw less terminals / ARA terminals not covered under this item. Cable termination rack shall be corrosive resistant and powder coated. (Inspection Agency By consignee)

10

48325

483255.1

... More
Supply of Fuse auto changeover system for Railway Signaling System as per RDSO/SPN/209/2012 Rev.2 or latest f o r Re lay r o o m f u s e s u p t o 1 0 Ampere capacity for 22 12V/24V/60V/110V DC and 110V AC systems. The units shall be mounted on DIN rail in adequate size enclosure as per instructions of Railway site engineer. Two no. of NO+NC contacts shall be provided for remote monitoring. The changeover time shall be less than 1 msec. The audio visual alarm for main and standby fuses shall be provided. One set means set of each fuse. (Inspection Agency By consignee)

2

2248

4496.34

... More
Supply o f PPTC fuse G P 60-185, UL-94 certification (1.6 Amps) for internal/external current. Make Fuzetec, Tyco, Raychem, Littlefuse or similar. (Inspection Agency By consignee)

20

10

202.8

... More
Supply of PPTC fuse GP 60-400, UL-94 certification (12 V/4 Amp) for TF,TR circuit. Make Fuzetec, Tyco, Raychem, Littlefuse or similar. (Inspection Agency By consignee)

20

8

171.2

... More
Supply o f PPTC fuse GP 30-100, UL-94 certification (24 V/ 1.4 Amp) for TPR circuit. Make Fuzetec, Tyco, Raychem, Littlefuse or similar. (Inspection Agency By consignee)

20

8

171.2

... More
Supply of PPTC fuse GP 250-185, UL-94 certification (24 V/ 4 Amp) 110V AC for Track Chargers. Make Fuzetec, Tyco, Raychem, Littlefuse or similar. (Inspection Agency By consignee)

20

8

171.2

... More
"Supply of Electric Point Machine 143 mm stroke, AC Immunity 160V AC, complete with lock detector and slides for lock detector,Non-trailable,to operate on 110V DC, rotary locking with crank handle universal type as per RDSO Spec. No. IRS:S-24/2002 (Amnd. 1) or latest, RDSO DRG. NO S-10800 (ALT.5) WITH JUNCTION BOX TELESCOPIC. THE MOTOR WILL BE AS PER RDSO SPECN. NO. IRS: 27 S-37/82 (AMND. 3) WITH RDSO DRG. NO. S-10910. This includes supply of Set of tools as per para 20.1 & 20.2 of RDSO SPECN. NO. IRS:S-24/2002 (AMND 1) The following set of tools in a suitable tool box shall be supplied along with every set of eight point machines or less. i). Hand operated square drive socket wrenches of 12.5 mm driving square (short type) as per IS: 7381 for M8, M10, M12 & M18 threads. (One 250 mm long 12.5 mm square extension bar as per IS: 7991 alongwith compatible Tee handle Square drive as per IS: 7975 suitable for above socket wrenches shall also be provided.) ii). Open jaw wrenches (spanners) for M10, M12," (Inspection Agency By RDSO)

8

100448

803586

... More
Supply o f stretcher bar insulation complete set consisting o f the following:- Plate-T- 10367-1 No., Bush T- 10368- 3 Nos. and washer-T- 10371 -6 Nos. (Inspection Agency By consignee)

40

363

14553.6

... More
Supply of gauge tie plate insulation complete set each set consisting plate T-10372 = 1No., Bush T- 10368=3 Nos. and washer - T-10371 = 6 Nos. (Inspection Agency By consignee)

40

364

14570.8

... More
"Supply of IRS Type point machine 'D'/'P' bracket insulation complete set consisting of the following:- Plate LH - S-3266-1 No, RH - S-3265-1 No., Plate S- 8804- 1 No., Bush - S- 3199 - 4 Nos, Bush S-8813- 2 Nos." (Inspection Agency By consignee)

40

462

18484.4

... More
"Supply and fixing o f G I bend pipe 5 0 m m dia., 'B'class, for cable entry into Point 31 machine with all accessories. Note: This item to be operated independently for those points where Point machines are functional but GI bend pipe is not provided. For all other new installation of Point machines, item 06002 o f the SOR includes the provision of GI bend pipe." (Inspection Agency By consignee)

4

3115

12462.92

... More
Supply of Track feed Battery Charger as per RDSO Specn. No.IRS: S-89/2013 Ver.1.0 or latest. Charging capacity rating should be suitable for charging 80 AH Battery. (Inspection Agency By RDSO)

-

-

32

... More
"Supply of Adjustable Track Feed Resistance 30 Ohms (Disc Type), Phenolic moulded base, as per RDSO Drg. No.SA-20161-66/M or latest." (Inspection Agency By RDSO)

2

2280

4561.64

... More
Supply of B Type Choke as per RDSO Specn.No.IRS:S- 65/83 (Amnd. 3) or latest. (Inspection Agency By RDSO)

28

5911

165530.96

... More
"Supply of Hydrometer, Exide make or similar for measuring specific gravity of Battery Graded acid with mounting stand in location Boxes." (Inspection Agency By consignee)

4

355

1422.96

... More
"Supply o f Channel pins, single groove, 7 mm, galvanised, suitable for 4 mm dia bonding wire for Track Circuit rail bonding, as per RDSO spec. IRS: S 17-75" (Inspection Agency By consignee)

78

3

301.86

... More
"Supply of 8 SWG GI wire (4 mm dia) suitable for Track circuit rail bonding as per RDSO spec. IRS: S 13-@ 10>46@" (Inspection Agency By consignee) (Inspection Agency By consignee)

4

76

306.64

... More
"Supply of Track Lead Junction Box(TLJB), 4 way, 250 mm x 255 mm x120 mm made from FRP, as per Drg.No. 20101/M(IRS) o r latest, including brass bolts and hylam board sheet with terminals etc. The FRP material shall be as per RDSO spec. RDSO/SPN/151/1997 or latest.The technical specifications are as follows: (a) TLJB complete with cover to be in black/red/grey with all the holes 38 required for mounting on FRP stump (vertical two for each FRP angle) HDPE pipe , cable etc. (b) Each TLJB shall have two bakellite terminal block fitted horizontally, each bakellite terminal block shall have two nickel chrome plate with brass terminal. Alongwith each TLJB , nickel chrome plated brass links(two nos.of adequate strength for vertical linking of the terminals to be supplied. (c) HDPE pipe alongwith two nuts for fixing on the TLJB hole . (d) The FRP stump for mounting the TLJB" (Inspection Agency By consignee)

38

5339

202913.16

... More
Supply of Offset brackets for Shunt Signal, made of Mild steel, outer diameter 89 mm (3.5 inch), thickness of pipe 4.5 mm with fixing arrangement on Shunt Signal post as per Drawing No SA- 23080/Adv. along with fixing U bolts, nuts and clamps. (Inspection Agency By consignee)

5

1898

9493.7

... More
"Supply o f Non Metallic (FRP) colour light signal housing multi unit type for railway 40 signaling suitable for RE area TWO Aspects, complete without lenses, lamps and signal transformer as per RDSO Drg. No. SA 23003 A/M (Adv.) and as per RDSO spec. No. RDSO/SPN/194/2006 (Rev 2.0) or latest and FRP material as per RDSO SPEC. No. RDSO/SPN/151/1997 or latest." (Inspection Agency By consignee)

4

31322

125289.4

... More
Supply of Position Light Shunt Signal Unit Complete, Non-Metallic, made of FRP as per Drg. No. SA-23840 (Adv.) suitable for LED Signal Lighting Unit.(Supply of LED Unit is not covered in this item) (Inspection Agency By consignee)

4

14796

59187.68

... More
"Supply and fixing of protective screen of expanded metal 12 SWG of size 1200 x 1500 mm on signals as per std. practice in RE Area and earthing the screen with MS flat of 2""x 1/4""using GI nut bolts and washer." (Inspection Agency By consignee)

2

3513

7027.04

... More
Supply o f ARA terminal block, made of PBT, as per RDSO spec. No. IRS: S-75/2006 (Rev.2) or latest and as per Drawing. No. SA- 23741A (Alt.-4) or latest. (Inspection Agency By RDSO)

1100

119

131252

... More
"Supply o f Apparatus Case/Location Box Full as per RDSO drg. no. RDSO/S-11500 or latest, with 'E' type lock and key ward no. 42, . The key and handle should be supplied at the rate of 44 one no. per four Apparatus cases. The 'E' type key lock i s as per RDSO Spec. IRS;S-30/64 o r latest, RDSO drg. no.SA 3376/M or latest and Key is as per Drg. No. 3377/M or latest. Note: This item includes the supply of 2 Nos E Type Lock fitted on both doors, along with two Keys." (Inspection Agency By Rites)

22

27512

605271.48

... More
"Supply of Apparatus Case/Location Box Half as per RDSO drg. no. RDSO/S-11507 or 45 latest, with 'E' type lock and key ward no. 42, . The key and handle should be supplied at the rate ofone no. per four Apparatus cases. The 'E' type key lock is as per RDSO drg. no.SA 3376/M or latest and Key is as per Drg. No. 3377/M or latest. Note: This item includes the supply of 2 Nos E Type Lock fitted on both doors, along with two Keys." (Inspection Agency By consignee)

11

19913

219051.36

... More
"Supply o f Disconnect Terminal block for four conductors with screwing cage/clamp type, sliding switch disconnect, as per RDSO spec. RDSO/SPN/189/2004 Ver. 3.0 or latest." (Inspection Agency By CONSGINEE)

1150

192

221731.5

... More
Supply of Phenolic laminated Sheet, resin bonded, grade P3 in standard size of 1220 X 1220 x 10 mm as per spec. No IS 2036 of 1995 or latest. Test report of manufacture to be supplied. (Inspection Agency By CONSGINEE)

29

5756

166928.06

... More
"Supply of Double Walled Corrugated (DWC) Pipe/duct with associated collars etc. as per RDSO Specification No. RDSO/SPN/204/2011 or latest anti- rodent & anti-oxidant and non flame propagating type in 6 meters straight length and of size 120 mm outer dia,& 103.5 mm inner dia. (The 48 manufacturers, suppliers must produce valid IS license and should be certified under ISO 9000 and shall submit copy of certificate). One coupler with suitable rubber O-ring should be supplied with every 6m of pipe length. (The total quantity of above items is equal to no. of pipes supplied.) DWC pipe shall be marked at every 1 mtr length in such a way that manufacturer's name, vendor name and year of manufacture can be easily identified." (Inspection Agency By RITES)

1000

656

656590

... More
Supply of Medium class GI pipes 100 mm dia (4.5 mm thickness) with thread collars as per IS 1239 (Part 1) 2004 or latest with coupling on culverts/bridges, perforated at a distance of 20 cm 49 or less with 10 mm dia hole, or at any other locations as decided by Site Engineer. It includes supply of all material required for fixing arrangement. Contractor will also supply flexible/corrugated HDPE pipe at the end of GI pipe to protect the cables from sharp edges and sudden. (Inspection Agency By CONSGINEE)

40

991

39670.4

... More
"Supply and fixing of RCC cable route marker, made with concrete in the ratio 1:3:6, engraved ""NCR"" ""S&T"" on top portion and painted on both sides, along the route at every 50 meter 50 and a t route diversion. The cable marker i s t o b e fabricated as per RDSO drawing no. SDO/cable laying/020, issued vide RDSO document no. RDSO/SI/G/2010 Version 1.1 dated 04.02.2014, or latest. The fixing work is to be done as per extant practice of NC Railway and as per Railway site supervisor incharge." (Inspection Agency By conshinee)

40

429

17162.4

... More
Supply of uncharged Low Maintenance Lead Acid (LMLA) secondary cell, 2V, 80 AH, in 51 dry condition, shelf mounting type, conforming to RDSO Specn.No.IRS:S-88/2004 or latest, with inter cell connectors, nuts and bolts, washers, microporous vent plug, float etc. (Inspection Agency By consignee )

24

3111

74682

... More
Supply of hand cuff lock of Godrej/Navtal or reputed make with key and as approved by site engineer. (Inspection Agency By consignee)

4

460

1842.08

... More
Supply of Offset brackets for Main Signal, made of Mild Steel, outer diameter 140 mm (5.5 inch), thickness of pipe 4.5 mm with fixing arrangement on Main Signal post as per Drawing No SA-23080/Adv.along with fixing U bolts, nut and clamps. (Inspection Agency By consignee)

2

1207

2414.28

... More
Supply of Non deteriorating type, Round head type, low voltage cartridge fuse as per Spec No IRS: S -78/92 with latest amendments, 2A/4A/10A rating capacity. (Inspection Agency By RDSO)

50

123

6160

... More
Supply and installation of earth electrode as per standard practice and as per NCR Drawing no. S&T/CONST/6.4/97. It includes supply of GI pipe of 3m length. It includes connecting the earth electrode to the equipments which are required to be earthed including digging of earth pit 3 55 mtr deep and fixing earth electrode pipe, casting of cement concrete enclosure with cover (cover as per drawing no. S&T/CONST/6.3/97. It includes installation of 7 strand GI wires as earth lead wires, supported on MS flat size 5mm x 40 mm, soldering and nut bolt both, one end of both earth lead wire and MS flat to earth electrode and other end to Location boxes, block equipments, power equipments, cable sheath, signals etc. as per site requirement and as per instructions given by engineer incharge. (Inspection by consignee)

35

3450

120783.6

... More
Supply of thermo shrink jointing kit as per RDSO Specn.No. IRS: TC 77-2012 (Rev.3.0) with (Amdt.-1 to 3) or latest, suitable for 6 Quad/jelly filled cables for straight through/derivation joints. It includes supply of all the accessories, without transformer. (Inspection by Consignee)

10

3361

33619.2

... More
"Supply of permanently lubricated HDPE duct, 40 mm outer dia, as per RDSO spec. No.RDSO/SPN/TC/45/2013 Rev.2 Amndt.2 or latest, along with all accessories like end caps, collars, bends, couplers etc." (Inspection by consignee)

2

76811

153622.84

... More
Supply of Colour Light Signal Post, Tubular Mild steel, 4.5 m length, 140 mm Dia, as 58 per RDSO spec. No. IRS: S-6/81 or latest and Supply of cast iron Main signal surface base (As per RDSO Drg. No. 2011/M or latest), with CLS ladder assembly suitable for colour light signal 4.5 m long, as per RDSO drg. No. SA 23153 and signal front staging complete assembly and complete signal back staging for CLS unit. (Inspection Agency By CONSGINEE)

4

25285

101140.8

... More
Fabrication and supply of point rodding (Ground Connection) set for electric point machine (RDSO Type) as per RDSO Drg. No.SA-8800-01, 20-21, 9151- 52,9000-01,03-04,9065- 66,9101, as applicable. (Inspection Agency By CONSGINEE)

4

14771

59084.32

... More
Modification/Alteration i n existing E I (Electronic Interlocking) a s p e r latest RDSO guidelines/TAN. It includes: Design and modification in existing Interface and Interlocking circuits and logic of EI system including modification in the VDU(Video Display Unit)/ LCP(Local Control panel)/ CCIP (Control cum Indication Panel), Maintenance terminal (MPC), Data Logger, Relay rack wiring. The complete work should comply with the latest RDSO specifications and guidelines and as per approved 1 SIP and circuit diagrams. All the material (Interface cards/relays/wiring material/connectors/fuses/communication devices etc.) shall be provided by the contractor.The work also includes the supply of modified Selection table, Interface Circuits, VDU/LCP/CCIP diagram etc. to suit the modified SIP. It also includes the carrying out of FAT, SAT (as applicable) jointly with Railways and satisfactory commissioning. All plans/drawings/circuits etc. should be prepared on AUTOCAD, softcopy to be supplied on Pen Drive and 06 sets of hard copies also to be supplied. Alteration involving modification in up to 10 routes.

2

1716057

3432115.82

... More
Installation wiring testing and commissioning of Fuse auto change over system. This 2 includes provision of common Buzzer & indication at ASM Room & ESM Duty Room and painting of fuse details. This also includes fabrication o f frame for installation o f FACS a t Station/ L C gate where installation of relay racks not feasible. One set means set of each fuse.

2

159

319.54

... More
Charging o f Lead Acid Batteries, 2V , 8 0 A H , with contractors o w n battery grade 3 sulphuric acid and distilled water with minimum two charge - discharge cycles, installation of charged batteries in groups & their connection & wiring. The work shall be done a s p e r t h e procedure prescribed by the OEM and extant practice of N.C.Rly and instruction of Engineer-in-charge. Detailed measurements of initial charging shall be recorded jointly by contractor & Rly's site-in-charge.

6

247

1483.62

... More
"Fixing, wiring, testing a n d commissioning of Electrical Po int Machine o n the Wooden/PRC sleepers at points as per standard practice and as per section of rails used. Item includes fixing switch extension bracket, providing insulation f o r switch extension bracket, fixing ground connection, adjusting opening of the switches and adjusting the point machine with crank handle.The 4 item also includes : (i)Complete material for installation like ground- connections, switch extension brackets, point insulation material, I pipes, wiring materials, various fixing nuts & bolts including castle nuts, spring washers (ii) All smithy & fitting works required at site for complete installation. (iii) Installation of gauge tie plate & providing insulation for gauge tie plate (Insulation in William Stretcher Bar will be provided by Railways). (iv) Wiring inside the point machine, insertion and termination of tail cable in point machine and junction boxes / location box /cable hut as per extent practice on NCR and the instruction of Railway Engineer at site. (v) Supply and fixing of bend pipes with welded"

4

14054

56216.8

... More
Removal of existing mechanical point fittings and FPL assembly from points, fixing of electrical point machine, ground connection, adjustment and testing with Crank handle for operation. Removal of ground connection, point machine after testing, and refixing the mechanical point fittings. 5 This will include fabrication and fixing o f bent pipes with welded frame fro cable entry to the point machine and termination of tail cable in the point machin, servicing and supply of SAE 30 lubricating oil. This will also include supply o f a l l necessary fixing material a n d adjustments t o make the mechanical point functional again. The work shall be done as per extant practice o n NCR and the instruction of Railway Engineer at site.

4

5512

22050.52

... More
"Installation of DC track circuits (Straight Portion) including supply of materials as per 6 directive of site Engineer. NOTE : (i) This includes drilling 9/32"" holes on rails, provision o f doublecontinuity G I wire bonding, provision of Block Joints 60 Kg/52 Kg/90R with machined fish plates, installation of Track lead junction box (separately for (+) and (-) rails), provision of track lead jumper wires/cables, fixing of track circuit equipment i.e. track charger, resistance, fuses, batteries, chokes, relays, anti- titling arranginment and painting, lettering and numbering of DC track circuit equipments etc., (ii) [a] Un-machined fish plates shall be supplied by the Railway's, but machining of fish plates shall be done by the Tenderer. In case of provision of Glued Joints by Engineering Department in lieu of RDSO Block joint, the cost of machining of fish plates@ 100/- per straight track circuit and @ 500/- per point zone track circuit will be deducted. [b] This includes insulation of gauge tie plates, Crossing plates, rod in siding points if required or any other place as instructed by Railway Site Engineer, by Tenderer's insulation materials. Railway will supply Track Charger, B-type choke, Resistance, Un- charged battery, TLJB and relays through a separate"

4

7718

30873.92

... More
"Installation o f D C track circuits (Point zone) including supply of materials as per directive of site Engineer. NOTE : (i) This includes drilling 9/32"" holes on rails, provision o f double continuity G I wire bonding, provision of Block Joints 60 Kg/52 Kg/90R with machined fish plates, installation of Track lead junction box (separately for (+) and (-) rails), provision of track lead jumper wires/cables, fixing of track circuit equipment i.e. track charger, resistance, fuses, batteries, chokes, 7 relays, anti- titling arranginment and painting, lettering and numbering of DC track circuit equipments etc., (ii) [a] Un-machined fish plates shall be supplied by the Railway's, but machining of fish plates shall be done by the Tenderer. In case of provision of Glued Joints by Engineering Department in lieu of RDSO Block joint, the cost of machining of fish plates@ 100/- per straight track circuit and @ 500/- per point zone track circuit will be deducted. [b] This includes insulation of gauge tie plates, Crossing plates, rod in siding points if required or any other place as instructed by Railway Site Engineer, by Tenderer's insulation materials. Railway will supply Track Charger, B-type choke, Resistance, Un- charged battery, TLJB and relays through a separate"

6

12472

74832.78

... More
Casting, concreting and curing o f foundation for Position Light Shunt Signal a s per Drg.No.NR/S&T/Const/2.2/97 using standard size of foundation/galvanized anchor bolts complete, 8 required for erection of shunt signal post. Anchor bolts complete should comply with the RDSO drg. no. SA 116 A/M. Item includes excavation, ramming of CC using vibrator, curing and plastering with 1:4 cement sand mixture. Aggregate cement, sand and holding down bolts, will be supplied by contractor. Any machines and tools, if required for execution of this item, will be arranged/provided by contractor.

4

3670

14681.32

... More
"Erection of Position Light Shunt signal with Base, Post, Signal unit, complete fixing of LEDs and wiring of full signal. It includes fixing of Number Plates. The work shall b e done a s per instructions of Rly engineer at site."

5

951

4757.4

... More
Excavation, casting, curing o f foundation and Installation and Erection o f Apparatus case Full (App. Case a s per RDSO drg. no. RDSO/S-11500 or latest) with contractor's own frame, 10 cement and other material in the ratio 1:3:6. 'E' type lock to be supplied and installed with App. case.This includes filling o f location foundations with river bed sand and plastering o n top with a mixture of 1:4 of cement and sand. It covers fixing of lamp holder , switch and lamp etc. in Apparatus Case.

22

12277

270111.82

... More
Excavation, casting, curing o f foundation and Installation and Erection o f Apparatus case Half (App. Case a s per RDSO drg. no. RDSO/S-11507 or latest) with contractor's own frame, 11 cement and other material i n the ratio 1:3:6.'E' type lock t o be supplied and installed with App. case.This includes filling o f location foundations with river bed sand and plastering o n top with a mixture of 1:4 of cement and sand. It covers fixing of lamp holder , switch and lamp etc. in Apparatus Case.

11

10332

113654.42

... More
Fixing o f ARA(M-6) Terminals /Screw less connectors / modular disconnect terminal 12 blocks and fuse blocks on phenolic laminated sheets and fixing by stainless steel/brass nuts & bolts. This includes provision of two additional holes on the board on either side for cable conductor entry. The work shall be carried out a per instructions of railway Engineer incharge.(Supply o f al l above terminals has been covered separately).

1100

18

19921

... More
Termination o f Outdoor Cables (Main Cables /tail cables) a t ARA/Disconnect type terminals provided in Apparatus Cases, Cable termination rack in relay room, station building, 13 generator room etc. The item includes dressing o f cables and wires with dressing threads a s per standard practice. All material required for this item will be supplied by contractor. The outdoor cable shall be terminated in Relay Room, DG Room, ASM Room etc under supervision and instructions issued by Engr. incharge of the work.

1900

28063

28063

... More
Fabrication and fixing o f phenolic laminated sheet of grade P3 , minimum 1 0 mm thick,as per Apparatus case diagram/plan, in location box by providing all fixtures like ARA/Disconnect 14 terminals, fuse blocks, fuses, relays on square bars etc. including fixing of PVC coated string rods at the back side for cable support with contractor's own material like iron angle, nuts, bolts etc. The iron angle for fixing shall be minimum 3 mm thick. This also includes fixing of teak wood shelf minimum 25 m m thick for holding track circuit equipments. The work shall b e done a s per instructions o f Rly engineer at site. (Apparatus case Full)

29

4478

129875.92

... More
Fabrication and fixing o f phenolic laminated sheet of grade P3 , minimum 1 0 mm thick,as per Apparatus case diagram/plan, in location box by providing all fixtures like ARA/Disconnect 15 terminals, fuse blocks, fuses, relays on square bars etc. including fixing of PVC coated string rods at the back side for cable support with contractor's own material like iron angle, nuts, bolts etc. The iron angle for fixing shall be minimum 3 mm thick. This also includes fixing of teak wood shelf minimum 25 m m thick for holding track circuit equipments. The work shall b e done a s per instructions o f Rly engineer at site. (Apparatus case Half)

4

2429

9717.16

... More
"Horizontal Boring/Manual mol ing without damage to surface r o a d / t rack for laying/isertion of DWC/GI/HDPE pipe. The bore shall be done at the depth of minimum 1400 mm from 16 the ground level. The ground level shall be considered ignoring the bank height of the bank of the road. Note:- DWC/HDPE/GI Pipe Supply i s not covered under this item. Contactor shall provide all material required for work and adequate nos. of labours for proper laying of cables into the bore. Cable shall be laid cautiously so that it should not get damage due to rough handling & pressure on cable. Payment of boring shall be made only after DWC/HDPE/GI pipe"

300

1083

324987

... More
Laying of S&T Cables of various cores/ pairs/ quads in trenches/ GI pipes/ RCC pipes/ 17 DWC pipes etc. as per the site requirement and as per approved cable route plan. This also includes laying of cables in track crossings & road crossings.(Cables will be meggered before and after its laying by contractor under supervision of Railway Representative and he will submit the meggering report of each testing). Length of the cable laid includes the length of the cable coiled for termination purposes.

18000

6

123120

... More
Laying and fixing of Medium class GI pipes 100 mm dia (4.5 mm thickness) as per IS 1239 ( Part 1) 2004 or latest with coupling on culverts/bridges, perforated at a distance of 20 cm or less with 10 mm dia hole, or at any other locations as decided by Site Engineer.The GI pipe i s to be 18 filled with chattered compound. I t includes supply o f all material required for fixing arrangement. Contractor will also supply flexible/corrugated HDPE pipe at the end of G I pipe to protect the cables from sharp edges and sudden bends. The laying and fixing to be done as per RDSO drawings no. SDO/cable laying/011 and SDO/cable laying/012, issued vide RDSO document no. RDSO/SI/G/2010 Version 1.1 dated 04.02.2014, or latest

40

354

14172

... More
"Excavation of cable trench as per cable route plan, 1.2 Mtr. deep and of 0.3 Mtr. to 0.6 Mtr. wide at bottom as per RDSO sketch No. SDO/CABLE LAYING/003, issued vide RDSO document no. RDSO/SI/G/2010 Version 1.1 dated 04.02.2014 or latest, alongside the track i n normal soil/strata (including soft rock), conforming to distances as per cable route plan and refilling and ramming of 19 loose soil. This work includes clearing o f route from bushes etc, covering of cable laid in trench by loose soil for a layer of 50mm thickness approximately before covering by bricks. The work shall be done as per the extant practice on North Central Railway and instructions of Railway Engineer at site. In case the full depth is not available, there shall be no proportionate payment and after the approval of minimum JAG officer, t h e concreting shall be done as per the RDSO drawing no.SDO/Cable laying/008, issued vide RDSO document no. RDSO/SI/G/2010 Version 1.1 dated 04.02.2014 or latest."

4000

64

258400

... More
"Excavation of cable trench as per cable route plan, 1.2 Mtr. deep and of 0.3 Mtr. to 0.6 Mtr. wide at bottom as per RDSO sketch No. SDO/CABLE LAYING/003, issued vide RDSO document no. RDSO/SI/G/2010 Version 1.1 dated 04.02.2014 or latest, alongside the track in Rocky soil, conforming to distances as per cable route plan and refilling and ramming of loose soil. This work includes 20 clearing of route from bushes etc, covering of cable laid in trench by loose soil for a layer o f 50mm thickness approximately before covering by bricks. The work shall be done as per the extant practice on North Central Railway and instructions o f Railway Engineer a t site. I n case the full depth i s not available, there shall be no proportionate payment and after the approval of minimum JAG officer, the concreting shall b e done a s per the RDSO drawing no.SDO/Cable laying/008, issued v ide RDSO document no. RDSO/SI/G/2010 Version 1.1 dated 04.02.2014 or latest."

100

87

8777

... More
"Cutting of all types of platforms/road crossing and trenching and excavation to a width and depth of 300 mm x 300 mm, laying of DWC/HDPE/GI pipe in the trench and refilling and concreting it afterwards as per original condition. In hard rocky ground area , cables will be laid normally on layer of soft earth of 0.05 mtrs thickness previously deposited at bottom of the trench . The cutting to be filled and finished with cement/concrete, as per the RDSO drawing no.SDO/Cable laying/008, issued vide RDSO document no. RDSO/SI/G/2010 Version 1.1 dated 04.02.2014 or latest."

-

-

21

... More
"Cross trench fo r identification o f t h e route of existing signlalling and telecomm cables."

50

290

14521

... More
Cement concrete work for miscellaneous, unscheduled items in ratio 1:3:6 of cement, 23 coarse, sand and aggregate Item includes excavation, ramming o f CC by using vibrator, curing and plastering with cement and sand mixture in ratio 1:4 (aggregate will not exceed beyond 3.8 cm). The aggregate cement and sand will be supplied by contractor.

40

5109

204384.8

... More
"Lettering and Numbering of all S&T gears like Signals, Loc. Boxes, Pt. Machines, TLJBs, Block joints etc. Each item to be taken as one unit."

70

85

5990.6

... More
"Painting of two coats of Enamel paint over one coat of Red Oxide primer after scrapping and cleaning of the surface. Paint to be of reputed make Asian/Dulux/Berger or similar.App. Cases inside and outside to be done by Silver colour. (Apparatus Case Full)"

4

681

2727.8

... More
"Painting of two coats of Enamel paint over one coat of Red Oxide primer after scrapping and cleaning of the surface. Paint to be of reputed make Asian/Dulux/Berger or similar.App. Cases inside and outside to be done by Silver colour. (Apparatus Case Half)"

6

620

3721.08

... More
"Painting of two coats of Enamel paint over one coat of Red Oxide primer after scrapping and cleaning of the surface. Paint to b e o f reputed make Asian/Dulux/Berger o r similar. (Main Signal post, base, unit and complete fittings)"

4

914

3657.84

... More
"Painting of two coats of Enamel paint over one coat of Red Oxide primer after scrapping and cleaning of the surface. Paint to b e o f reputed make Asian/Dulux/Berger o r similar. (Shunt Signal post, base, unit and complete fittings)"

5

389

1949.75

... More
Painting of two coats of Enamel paint over one coat of Red Oxide primer after 29 scrapping and cleaning of the surface. Paint to b e o f reputed make Asian/Dulux/Berger o r similar. (Point machine and ground connections, Point machine by Black enamel and ground connection by Red oxide)

4

288

1154.04

... More
Dismantling and Releasing o f existing Location boxes/Apparatus cases/Jn boxes and other associated S&T fittings. All the released material will be transported to the SSE/Consignee depot.

30

972

29162.4

... More
"Dismantling and Releasing of existing Signals (both electrical and Mechanical) and other associated S&T fittings like wheel, pulleys, wires, stakes etc. All the released material will be transported to the SSE/Consignee depot."

3

1529

4589.1

... More
Laying of Double Wall Corrugated (DWC) pipe of all sizes with socket, coupler and T 32 Joint etc. by digging of trench 0.3 Meter width, 1.2 Meter depth from rail flange under track for track crossing and refilling after laying of pipes, as per technical specifications and the restoration of disturbed ballast by screening a n d dressing a s p e r instruction of Engineer-in-charge or his representatives at site.

320

80

25740.8

... More
Development and preparation of SIP, SWRD/GWRD,SWR etc based on existing GAD/SIP/ESP .(For station/LC upto 4 lines)

2

24235

48471.5

... More
"Wiring in relay room/ location box fixing of Q series relay base plate/ metal to metal relay mini group and major group base plates, laying lacing dressing & packeting of 60/40 core PVC indoor cable/ flexible wire and termination of 60/40 core cable/ flexible wire on tag block/ base plate & soldiering. wiring of circuits to be done as per rly.site engineer on relay interlocking system using metal to metal / metal to carbon type relay and soldering after testing. This also includes fuse wiring, function wiring. (Interconnection between relay rack & 0.6mm, 1.0mm RDSO spec. no IS 694/1990, :76/89 or latest and should be procured form RDSO approval sources and 16/0.02 multi strand flexible etc. Resin core, solder wire, lacing thread adhesive tapes, resistance, condensers, diodes, lugs.etc of various ratings and capacity as per site. requirement will be supplied by the contractor. free of cost and will be sued after approval of Rly engineer at site. The jumper wire"

-

-

34

... More
Loading, Transportation/Carriage and Unloading of various S&T material by a 9 MT truck, from/to the consignee depot to/from various locations, as decided by the Railways.

900

53

47952

... More
Casting, concreting and curing of foundation for Main Signal Post in the ratio of 1:3:6 as per NCR drg.No. TYP/013/14/SIG FOUND. dtd 12.11.2014 (total 2 sheets of drawing) issued vide NCR Letter no. S&T/NCR/DRG/TYP dated 13.11.2014, using standard size of foundation/galvanized anchor 36 bolts complete, required for erection of colour light signal post. Anchor bolts complete should comply with the RDSO drg. no. SA 116 A/M. Item includes excavation, ramming of CC using vibrator, curing and plastering with 1:4 cement-sand mixture (aggregate will not exceed 3.8 cm). Aggregate, cement, sand and holding down bolts will be supplied by contractor. Any machines & tools, if required for execution of this item, will be arranged/provided by contractor.

2

13512

27024.86

... More
"Horizontal direction dril l ing (HDD)/Trenchless digging/machine dril l ing without damage to surface road /track for laying/insertion of HDPE/GI/DWC pipe. The bore shall be done at the depth of minimum 1400 mm from the ground level. The ground level shall be considered ignoring the 37 bank height of the bank of the road. Note:- DWC/HDPE/GI Pipe Supply is not covered under this item. Contactor shall provide all material required for work and adequate nos. of labours for proper laying of cables into the bore. Cable shall be laid cautiously so that it should not get damage due t o rough handling & pressure on cable. Payment of boring shall be madeonly after DWC/HDPE/GI pipe is laid in the bore."

100

616

61635

... More
"Splicing of 24 core optic fibre cable and making the splicing joint with contractor's 38 own machine and tools. Joint should be prepared in such a way that the top of the enclosure shopuld be at a depth of minimum 1.2 mtr and the enclosure should be covered with soft soil and bricks. Splice loss of each fibre should be less than 0.05 dB."

8

12011

96094

... More
Blowing/drawing of OFC cable in the HDPE pipe duct and protective work already 39 provided in the trench. The cable shall be laid only after the successful completion of the DIT (Duct Integrity test). The DIT should be certified by the Railway engineer at site. All the equipments/machinery required shall be arranged by the contractor.

2

17093

34186.1

... More
Installation o f thermo shrink jointing k i t a s per RDSO Specn.No. IRS: T C 77-2012 (Rev.3.0) w i t h (Amdt.-1 t o 3 ) o r latest, suitable f o r 6 Quad/jelly fi l led cables for straight through/derivation joints. It includes supply of all the accessories, without transformer

10

1682

16828.7

... More
Laying o f HDPE duc t a s p e r t h e approved cable route p l a n i n t h e exavated trenches/other protected works/RCC channel etc. including all accessories like end caps, collars, 41 bends, couplers etc. The ends of the duct to be sealed with end plugs till OFC blowing is done. Important: The laying of OFC cable independently or along with Quad cable/PIJF cable in the same trench shall be governed by the RDSO drawings no. RDSO/TCDO/COP-6(a) and RDSO/TCDO/COP-8(a) respectively, issued vide Chapter-XIII of the Telecomm Manual.

2

8092

16184.5

... More
Refixing o f electrical point machine, ground connection during phase working (Non 42 interlocked working) after removing t h e existing fitting i f any, adjustment if necessary, cable termination, wiring , testing and commissioning of electrically operated point, fixing and connecting point indicator on derail switch if necessary. The work shall be done as per extant practice on NCR and the instruction of Railway Engineer at site.

4

3568

14274.24



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.