If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

North Central Railway - NCR Tender

Works
Electrical Works
Ireps
Opening Date21 Nov 2024
Closing Date20 Dec 2024
Tender Amount₹ 27,26,846.86 
Notes
Download

Costs

Summary

Operation , Maintenance And Repair Of Electrical And Electronic Installations Of Irtmtc/pryj

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Flexible hose in geyser . 2

50

17

899

... More
Dismantling and refitment charges . 3

100

89

8963

... More
Providing and fixing heating elements in 2kW geysers. 4

50

127

6353.5

... More
Providing and fixing heating elements in 3kW geysers .

50

130

6533

... More
Providing and fixing thermostats small and big. 6

50

64

3237

... More
Providing and fixing thermal cut off .

50

24

1211

... More
Repairing of worn out shaft of ceiling fan 2

150

19

2964

... More
Providing , fixing and replacement of defective ball bearing 6202-2Z in ceiling fan . 3

150

22

3300

... More
Rewinding of defective ceiling fan. 4

150

111

16717.5

... More
Recovery for released scrap copper after rewinding of ceiling fan 5

101.25

-

-9731.14

... More
Repairing of worn out shaft of exhaust fan 12" sweep . 6

100

21

2156

... More
Rewinding of defective exhaust fan 12" sweep . 7

100

96

9603

... More
Recovery for released scrap copper after rewinding of 12" exhaust Fan

60

-

-5766

... More
Providing , fixing and replacement of defective ball bearing 6203-2Z in exhaust fan 12" sweep.

100

27

2733

... More
Providing , fixing and replacement of defective ball bearing 6202-2Z in exhaust fan 18" sweep. 10

100

29

2949

... More
Repairing of worn out shaft of exhaust fan 18" sweep 11

100

28

2877

... More
Rewinding of defective exhaust fan 18" sweep 12

100

203

20391

... More
Recovery for released scrap copper after rewinding of 18" exhaust fan .

90

-

-8649.9

... More
Complete servicing of split AC including cleaning by water 2

50

126

6319

... More
Gas charging in compressor of 2 Ton split AC if required 3

40

493

19720.4

... More
Providing and fixing of thermostat for AC 4

20

80

1615.4

... More
Providing and fixing of overload relay for AC 5

20

80

1615.4

... More
Providing and fixing of running capacitor for AC 6

20

87

1753.8

... More
Providing and fixing of Starting capacitor for AC 7

20

100

2014

... More
Gas charging in water cooler compressor if required

10

317

3172.4

... More
Providing and fixing of thermostat for water cooler 9

-

-

8

... More
Providing and fixing of overload relay for water cooler 10

10

136

1363.6

... More
Providing and fixing of capacitor for water cooler 11

10

12

125

... More
Rewinding of water cooler motor 12

10

336

3361.4

... More
Recovery for released scrap copper after rewinding of water cooler motor 13

8.9

-

-748.49

... More
Replacement of defective compressor with new one of Double door Refrigerator. 14

2

1509

3018.08

... More
Replacement of defective compressor with new one of deep freezer

2

4393

8786.82

... More
Recovery for released scrap copper after rewinding of submersible motor

30

-

-2883

... More
Repairing of complete submersible motor of capacity 30 H.P in all respect by rewinding, changing bush bearing top and bottom, changing thrust bearing segment, etc as per Schedule of work -E

4

3334

13339.24

... More
Repairing of complete submersible pump 30 H.P in all respect by changing bush gun metal, changing running bush gun metal , etc as per Schedule of work -F

4

1969

7876

... More
Lifting and lowering of submersible water supply pump- motor assembly in pump house including tool and plant if required

4

751

3006.48

... More
Wiring for light/fan/exhaust fan/call bell points with 1.5 sqmm (22/.3 mm) PVC insulated single core unsheathed stranded Copper conductor ISI marked cable in recessed PVC pipe 1 of ISI mark, MS switch box having wall thickness 16 SWG with 3 mm thick phenolic laminated sheet cover including running of 16 SWG/(1.5 sqmm PVC insulated single core unsheathed stranded Copper conductor) copper earth wire along with the pipe duly clamped as required and as per relevant technical specification No. Sr.DEE/G/ALD/IE/94/104/Rev and additional specification. a) Medium Point.

75

233

17512.5

... More
Wiring for 3/5 pin, 5 Amp. Plug point with 1.5 sqmm (22/.3mm) PVC insulated single 1 core unsheathed stranded Copper conductor ISI marked cable including providing and fixing 3/5 pin 5 Amps. Socket out let with switch on same board and earthing the 3rd pin with 16 SWG/(1.5sqmm PVC insulated single core unsheathed stranded Copper conductor) copper earth wire etc. as required and as per relevant technical specification.

100

62

6286

... More
Wiring for 3/5 pin 15 amps plug point with 2.5 sqmm (36/0.3mm) PVC insulated single core unsheathed stranded Copper conductor ISI marked in recessed PVC pipe of ISI marked and MS 1 switch box having wall thickness 16 SWG with 3 mm thick phenolic laminated sheet cover including providing and fixing 3/5 pin 5/15 amps socket outlets and 5/15 amps piano type switch and earthing the 3rd pin with 16 SWG/(1.5 sqmm PVC insulated single core unsheathed stranded Copper conductor) copper earth wire along with the pipe duly clamped as required and as per relevant technical specification No. (5pin 15 Amp).

50

387

19357

... More
Wiring for circuit with 2.5 sqmm (36/0.3mm) PVC insulated single core unsheathed 1 stranded Copper conductor ISI marked cable in recessed PVC pipe of ISI marked and running of 16 SWG/(1.5sqmm PVC insulated single core unsheathed stranded copper conductor) copper earth wire duly clamped with pipe and providing multiway connector on MS switch box for neutral looping etc. as required and as per relevant technical specification. (a) 2 x 2.5 sq mm.

450

72

32472

... More
Wiring for circuit with 2.5 sqmm (36/0.3mm) PVC insulated single core unsheathed 1 stranded Copper conductor ISI marked cable in recessed PVC pipe of ISI marked and running of 16 SWG/(1.5sqmm PVC insulated single core unsheathed stranded copper conductor) copper earth wire duly clamped with pipe and providing multiway connector on MS switch box for neutral looping etc. as required and as per relevant technical specification. (b) 4 x 2.5 sq mm.

270

88

23892.3

... More
Wiring for submain with 4 sqmm (56/0.3mm) PVC insulated single core unsheathed 1 stranded Copper conductor ISI marked cable in recessed PVC pipe of ISI marked and running of 16 SWG/(1.5sqmm PVC insulated single core unsheathed stranded copper conductor) copper earth wire duly clamped with pipe and providing multiway connector on MS switch box for neutral looping etc. as required and as per relevant technical specification. (a) 2 x 4 sq mm.

360

69

24904.8

... More
Wiring for submain with 4 sqmm (56/0.3mm) PVC insulated single core unsheathed 1 stranded Copper conductor ISI marked cable in recessed PVC pipe of ISI marked and running of 16 SWG/(1.5sqmm PVC insulated single core unsheathed stranded copper conductor) copper earth wire duly clamped with pipe and providing multiway connector on MS switch box for neutral looping etc. as required and as per relevant technical specification. (b) 4 x 4 sq mm.

90

110

9946.8

... More
Wiring for luminaries and fancs with 2x1 sqmm (14/0.3mm) PVC insulated single core 1 unsheathed stranded Copper conductor along with 16 SWG/(1.5sqmm PVC insulated single core unsheathed stranded copper conductor) copper earth wire through PVC pipe 20mm including connecting, testing & commissioning as required and as per relevant technical specification... 2 x 1 sq mm

180

44

8038.8

... More
Providing and burying of earth electrode of 40 mm dia 'B' class GI pipe of 3.0 Mtrs long having 12 mm dia holes spaced 75 mm apart drilled upto 2 mtrs length from the bottom 1 including 340 mm wide pit is to be dug upto the depth of not less than 3750mm. The earth electrode lowered in the pit thereafter refilling of pit is to be done with 30mm alternate layer of salt and charcoal upto 2.5 Mtrs. Pit is to be made of not less than 40 x40x30 cms from inside & precast RCC cover of 40mm thick with lifting arrangement shall confirm to CEE/NR specification No. NR/Elect/Wiring/1-84 and Drg. No. Sr.DEE/G/ALD 10/94.

20

923

18470.6

... More
Providing and fixing of 6 Mtr. Galvanized (as per BS EN ISO 1461) octagonal pole with base plate 220x220x12mm, top 70mm and 130mm of 3mm thick sheet suitable for maximum wind speed upto 160 km/Hr. including foundation bolts and foundation with M 20 grade RCC and FE 415 1 grade reinforcement (450x450x800 mm deep) (foundation should be as per design approved by pole manufacturer) GI base plate G.I. anchor plate etc. as required including supplying and fixing of double arm hot dipped galvanized bracket suitable for street light fittings and supplying and drawing of 3x2.5 sqmm FRLS copper conductor single core cable from junction box with two nos. 6/10 AMP MCB to luminaire complete including termination with copper lugs as required.

1

9518

9518.07

... More
Providing, fixing,replacement, testing, connecting and commissioning of 120 Watt or above LED flood lights fitting as per IS: 10322, LED Luminaries:- (1) A complete LED lighting unit consisting of a light source and driver together with parts of distribute light, to position and protect 1 the light source, and to connect the light source to a branch circuit. The light source itself may be an LED array and LED module, or an LED lamp. (2):- Supplied LED luminaries shall confirm to IS : 16101 (2012) IS:16106(2012), Light Source (LED) in the Luminaries should be of make:- (1):- NICHIA/CREE/OSRAM/SEOUL/PHILIPS/LUMILEDS/LEDNIUM. (2) :- LEDs to IS: 16105(2012). IS: 16108(2012), IEC:62471. Type LED:- High power LED, SMD (Surface Mounting device)/COB (Clip on board). 1.Input operating voltage :- 105-295 V AC. 2:- Normal Voltage-220V AC. 3. Driver Type: constant current driver with short circuit protection 4. LED life:- > 50000 burning hours. 5. Depreciation:- 30% max, after 50000 burning hours. 6. Control of distribution:- Full cut off. 7. Surge protection: 4 KV. 8. Drive component : Industrial grade only. 9. Efficiency of driver electronic: > 85% . 10. Beam angle :> = 140 degree along with road and >=80 degree across the road. 11. Colour temperature:5000-6500K. 8. Colour rendering index (CRI) :> 75.13. Ingress protection : IP-66.14. Lumen output: > 120 lumens/watt. 15. Power factor :> 0.95. 16. Total harmonics distortion (THD):- <15% 17. Lamp cover: Toughened glass or UV stabilized poly carbonate. 18. Finishing: Power coated/Anodized. 19. Secondry optics: poly carbonate reflector/poly carbonate lens. 20. Construction of housing: extruded aluminum/CRCA/Pressure die cast aluminum. 21. Mounting: Suitable for existing pole/Truss/Lantern mounted. 22. Certificate: Firm to submit LM80 (In respect of LED used) & LM 79 (In respect of luminaire used) test certificate from National/International accredited Laboratory and OEM certificate for compliance of BIS/IEC. 23. Warranty: Firm to submit warranty certificate for five year along with the supply. All fitting shall be fitted with new suitable bend/elbow with clamp and proper nut and bolt and connection with twisted twin flexible cord of minimum size 16/1 mm copper conductor as per relevant technical specification. Material parameters must remain unchanged during entire warranty period.

40

9771

390864



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.