North Central Railway Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

North Central Railway - NCR Tender

Works
Telecommunication Services
Ireps
Opening Date17 Dec 2024
Closing Date10 Jan 2025
Tender Amount₹ 7,11,24,375.89 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Installation, wiring, testing and commissioning of embedded fanless PC based Maintenance terminal/Datalogger terminal as per RDSO spec. No. RDSO/SPN/192/2019 Ver. 2.0 or 4 latest & RDSO TAN No. - STS/E/TAN/3007 version 1 dated:02.11.12 supplied vide SOR item 01004.Including the necessary furniture for Video terminal i.e. Video table model Companion C3D or similar and revolving chair PCH-5002T of GODREJ make or similar shall be supplied by the contractor at his own cost. It should be supplied after the approval of the Railway Site supervisor incharge.

1

97149

97149.87

... More
Design, Supply, installation, wiring and commissioning of housing as per systematic arrangement given by work incharge for both the operating consoles with PC ,VDU display, mouse and 5 keyboard with suitable work space and sitting arrangement for operator as per Drg No. TYP/16/0007. Final layout of the VDU table shall be as per the size of the VDU and should be customised as per ASM room's space. Wooden block counter made of teak wood frame and 3 mm thick waterproof plywood with for mica finish on top on all four sides, having two compartments inside and two doors on opposite sides.

1

12271

12271.93

... More
Installation, Wiring, Testing & Commissioning of complete Electronic Interlocking system as per RDSO specification No. RDSO/SPN/ 192/2019 ver. 2.0 or latest with Hot Standby arrangement for functioning of EI system, supplied vide Item No. 01001 of SOR, including 6 transportation of required materials from consignee's depot to site, erection and grouting of EI Relay Racks, fixing and wiring of all the interfacing relays (Vital & Non-Vital), installation and wiring of Microprocessor equipments, interface equipments, power supply equip ments and all other associated accessories to make complete EI sys to be functional, FAT and SAT, Technical Advisory Notes (TAN) issued by RDSO time to time on installation practices of EI are to be complied.

1

629289

629289.28

... More
Supply of essential spares (For CPA station) as per RDSO recommendations for EI 7 system at above mentioned station. Item - wise details of spare to be supplied with unit rates shall be given by the tenderers. For tender evaluation total cost of all spares will be considered and individual rates will not be considered for evaluation. Inspection by RDSO.

1

1964090

1964090.3

... More
Provision of Ring Earth for EI system, consisting of 06(six) number of maintenance free earths, which includes supply of all components of earthing & bonding system like earth electrode, earth enhancement materials, earth pit, equi-potential earth bus bar, connecting cables and tape/strips and other associated accessories in accordance with RDSO Spec. No. RDSO/SPN/197 Ver.1.0 or latest and provision of earth pits to be connected in a ring to achieve less than 01(One) ohm earth resistance for connecting EI equipments, relay racks, panel, power equipments as per RDSO TAN No. STS/E/TAN/3006 dated 02.11.2012. Diagram of ring earth should be supplied to Railway for approval before execution. All related materials as recommended by RDSO in Spec. No. RDSO/SPN/197 Ver. 1.0 or latest, will be supplied by the contractor. Note: If due to site condition (high soil resistivity, larger size of EI room etc.) more than six maintenance free earths are required then the rate of payment for each such extra individual earth shall be done as per the rates of SOR items 13002 and 13003 (Earthing Items SOR). No other payment for any other material/accessory/ fixture etc. shall be admissible for such extra maintenence free earths. contractor shall visit the site to see the position of Relay room, IPS room and SM room for earthing connectivity.

-

-

8

... More
Supply of Double Walled Corrugated (DWC) Pipe/duct with associated collars etc. as per RDSO Specification No. RDSO/SPN/204/2011 or latest anti-rodent & anti-oxidant and non flame propagating type in 6 meters straight length and of size 120 mm outer dia,& 103.5 mm inner dia. (The 9 manufacturers, suppliers must produce valid IS license and should be certified under ISO 9000 and shall submit copy of certificate). One coupler with suitable rubber O-ring should be supplied with every 6m of pipe length. (The total quantity of above items is equal to no. of pipes supplied.)DWC pipe shall be marked at every 1 mtr length in such a way that manufacturer's name, vendor name and year of manufacture can be easily identified.

1000

656

656590

... More
Supply and fixing of RCC cable route marker, made with concrete in the ratio 1:3:6, engraved "NCR" "S & T" on top portion and painted on both sides, along the route at every 50 meter 10 and at route diversion. The cable marker is to be fabricated as per RDSO drawing no. SDO/cable laying/020, issued vide RDSO document no. RDSO/SI/G/2010 Version 1.1 dated 04.02.2014, or latest. The fixing work is to be done as per extant practice of NC Railway and as per Railway site supervisor incharge.

50

429

21453

... More
Excavation of cable trench as per cable route plan, 1.2 Mtr. deep and of 0.3 Mtr. to 0.6 Mtr. wide at bottom as per RDSO sketch No. SDO/CABLE LAYING/003, issued vide RDSO document No. RDSO/SI/G/2010 Version 1.1 dated 04.02.2014 or latest, alongside the track in normal (all type) soil/strata, conforming to distances as per cable route plan and refilling and ramming of loose soil. 11 This work includes clearing of route from bushes etc,covering of cable laid in trench by loose soil for a layer of 50mm thickness approximately before covering by bricks as per actual site requirement. Supply of bricks to be covered under different schedule item. The work shall be done as per the extant practice on North Central Railway and instructions of Railway Engineer at site. In case 1.2m depth of trench is not achievable due to site conditions, specific approval of JAG/SG Officer will be required for each site where trench depth of 1.2m is not possible, only after approval of JAG/SG Officer proportionate payment can be done.

8000

87

702160

... More
Laying of S&T Cables of various cores/ pairs/ quads in trenches/ GI pipes/ RCC pipes/ DWC pipes etc. as per the site requirement and as per approved cable route plan. This also includes 12 laying of cables in track crossings & road crossings.(Cables will be meggered before and after its laying by contractor under supervision of Railway Representative and he will submit the meggering report of each testing). Length of the cable laid includes the length of the cable coiled for termination purposes.

205000

6

1402200

... More
Horizontal Boring/Manual moling without damage to surface road /track for laying/isertion of DWC/GI/HDPE pipe. The bore shall be done at the depth of minimum 1400 mm from 13 the ground level. The ground level shall be considered ignoring the bank height of the bank of the road. Note:- DWC/HDPE/GI Pipe Supply is not covered under this item. Contactor shall provide all material required for work and adequate nos. of labours for proper laying of cables into the bore. Cable shall be laid cautiously so that it should not get damage due to rough handling & pressure on cable. Payment of boring shall be made only after DWC/HDPE/GI pipe is laid in the bore.

1000

1083

1083290

... More
Cutting of all types of platforms/road crossing and trenching and excavation to a width and depth of 300 mm x 300 mm, laying of DWC/HDPE/GI pipe in the trench and refilling and 14 concreting it afterwards as per original condition. In hard rocky ground area , cables will be laid normally on layer of soft earth of 0.05 mtrs thickness previously deposited at bottom of the trench . The cutting to be filled and finished with cement/concrete, as per the RDSO drawing no. SDO/Cable laying/008, issued vide RDSO document no. RDSO/SI/G/2010 Version 1.1 dated 04.02.2014 or latest.

500

158

79440

... More
Supply of Colour Light Signal Post, Tubular Mild steel, 4.5 meter length, 140 mm Dia, as per RDSO spec. No. IRS: S-6/81 or latest and Supply of cast iron Main signal surface base (As per RDSO Drg. No. 2011/M or latest), with CLS ladder assembly suitable for colour light signal 4.5 meter long, as per RDSO drg. No. SA 23153 and signal front staging complete assembly and complete signal back staging for CLS unit.

-

-

15

... More
Supply, fabrication and fixing of retro-reflective marker/boards/plates as per the 16 following: 'P'marker-Non illuminated as per Drg. No.SA-23456 (Adv), 'AG' marker-Non illuminated as per Drg. No. SA-23459-60 (Adv), 'A' marker - Illuminated as per Drg. No.SA-23461(Adv), 'G' marker - Non illuminated as per Drg. No.SA-23477(Adv) or as applicable and provided by Railways.

5

887

4438.85

... More
Supply, fabrication and fixing of Retro-reflective Signal number plates as per NCR drg. No. TYP/14/0014 dtd 28.11.2014 issued vide NCR letter No. S&T/ NCR/DRG/TYP dated 28.11.2014, on signal post with contractor's own material like clamp, U bolts, nuts etc

40

744

29793.6

... More
Supply of Non Metallic (FRP) colour light signal housing multi unit type for railway 18 signaling suitable for RE area TWO Aspects, complete without lenses, lamps and signal transformer as per RDSO Drg. No. SA 23003 A/M (Adv.) and as per RDSO spec. No. RDSO/SPN/194/2006 (Rev 2.0) or latest and FRP material as per RDSO SPEC. No. RDSO/SPN/151/1997 or latest

11

31322

344545.85

... More
Supply of Non Metallic (FRP) colour light signal housing multi unit type for railway 19 signaling suitable for RE area THREE Aspects, complete without lenses, lamps and signal transformer as per RDSO DRG. No. SA 23002 A/M (Adv.) and as per RDSO spec. No. RDSO/SPN/194/2006 (Rev 2.0) or latest and FRP material as per RDSO SPEC. No. RDSO/SPN/151/1997 or latest.

3

35753

107260.95

... More
Supply of Non Metallic (FRP) colour light signal housing multi unit type for railway 20 signalling suitable for RE area FOUR Aspects, complete without lenses, lamps and signal transformer as per RDSO Drg. No. SA 23001 A/M (Adv.) and as per RDSO spec. No. RDSO/SPN/194/2006 (Rev 2.0) or latest and FRP material as per RDSO SPEC. No. RDSO/SPN/151/1997 or latest.

2

42250

84500.14

... More
Supply of Off set brackets for Main Signal, made of Mild Steel, outer diameter 140 mm (5.5 inch), thickness of pipe 4.5 mm with fi xing arrangement on Main Signal post as per Drawing No. SA-23080/Adv. along with fi xing U bolts, nut and clamps.

15

1207

18107.1

... More
Supply of Junction route indicator unit 3 way, made of FRP, (Without Lenses & Holder) 22 as per Drg. No. SA 23401-06 (Adv.) (as applicable)suitable for LED Signal Lighting Unit and as per RDSO spec.No. IRS: S-66/84 Amd.-1 or latest and RDSO/SPN/194/2006 Rev.2 or latest.(Supply of LED Unit is not covered in this item)

1

46778

46778.93

... More
Supply of Junction route indicator unit 4 way, made of FRP, (Without Lenses & Holder) 23 as per Drg. No. SA 23401-06 (Adv.) (as applicable) suitable for LED Signal Lighting Unit and as per RDSO spec.No. IRS: S-66/84 Amd.-1 or latest and RDSO/SPN/194/2006 Rev.2 or latest.(Supply of LED Unit is not covered in this item)

1

49751

49751.27

... More
Supply of Position Light Shunt Signal Unit Complete, Metallic, Independent type, along with base and post, hood, Cover etc as per Drg. No. SA-23840 (Adv.) suitable for LED Signal Lighting Unit.(Supply of LED Unit is

5

4080

20403.7

... More
Supply of Position Light Shunt Signal Unit Complete, Metallic, Post type, along with Off set bracket, Hood, Cover, mounting socket etc as per Drg. No. SA-23840 (Adv.) or latest, suitable for LED Signal Lighting Unit.(Supply of LED Unit is not covered in this item)

12

8856

106275.48

... More
Supply of Off set brackets for Shunt Signal, made of Mild steel, outer diameter 89 mm (3.5 inch), thickness of pipe 4.5 mm with fixing arrangement on Shunt Signal post as per Drawing No. SA-23080/Adv. along with fi xing U bolts, nuts and clamps.

2

1898

3797.48

... More
Supply of hand cuff lock of Godrej/Navtal or reputed make with key and as approved by site engineer.

100

460

46052

... More
Supply of Calling ON Signal Unit, Non metallic, with Brackets, clamps and fixing 28 accessories, suitable to LED signal lighting unit and as per RDSO spec. No. RDSO/SPN/194/2006 (Rev. 2.0) or latest. The FRP material shall conform to RDSO/SPN/151/1997 or latest. Calling On Signal Unit shall conform to RDSO Drg No. SA-24351(Adv) Alt1 or latest without lamp, lamp-holder and lens.

5

11667

58336.85

... More
Casting, concreting and curing of foundation for Main Signal Post in the ratio of 1:3:6 as per NCR drg.No. TYP/013/14/SIG FOUND. dtd 12.11.2014 (total 2 sheets of drawing) issued vide NCR Letter No. S&T/NCR/DRG/TYP dated 13.11.2014, using standard size of foundation/galvanized anchor 29 bolts complete, required for erection of colour light signal post. Anchor bolts complete should comply with the RDSO drg. No. SA 116 A/M. Item includes excavation, ramming of CC using vibrator, curing and plastering with 1:4 cement-sand mixture (aggregate will not exceed 3.8 cm). Aggregate, cement, sand and holding down bolts will be supplied by contractor. Any machines & tools, if required for execution of this item, will be arranged/provided by contractor

14

13512

189174.02

... More
Casting, concreting and curing of foundation for Position Light Shunt Signal as per Drg. No. NR/S&T/Const/2.2/97 using standard size of foundation/galvanized anchor bolts complete, required 30 for erection of shunt signal post. Anchor bolts complete should comply with the RDSO drg. No. SA 116 A/M. Item includes excavation, ramming of CC using vibrator, curing and plastering with 1:4 cement sand mixture. Aggregate cement, sand and holding down bolts, will be supplied by contractor. Any machines and tools, if required for execution of this item, will be arranged/provided by contractor

5

3670

18351.65

... More
Erection of CLS Post with base and signal unit on top or on Off set Bracket including erection of auxiliary signals like calling on, shunt signal if any. It includes fixing of all LEDs and wiring 31 of complete signal including route and auxiliary signals, if any. It includes fixing of front and back staging, ladder and guards, signal name plates / boards, with contractor's own brackets and fixing materials. Th e work shall be done as per instructions of Railway engineer at site. It also includes provision & fixing of maintenance platform as per design given by Engineer -In-Charge at site. Th e Item includes cutting of Signal post if required by Site In charge.

14

5881

82339.88

... More
Erection of Position Light Shunt signal with Base, Post, Signal unit, complete fixing of LEDs and wiring of full signal. It includes fixing of Number Plates. Th e work shall be done as per instructions of Rly engineer at site.

5

951

4757.4

... More
Fixing of Junction type Route Indicator on top of signal post and complete wiring, 1- Way/2-Way/3-Way/4-Way/5-Way/6-Way/theater type

2

1112

2225.02

... More
Supply, fabrication and fixing of the Calling On board/BSLB board as per RDSO Drg. No. 34 SA 2373 (Adv)/Stop/Warning board as per drg. No. SA-2380 (Adv), or as applicable, on concrete foundation and painting with Retro reflective paint. All work to be carried out as per Railway site engineer instructions.

5

8112

40562.4

... More
Supply of Apparatus Case/Location Box Full as per RDSO drg. No. RDSO/S-11500 or 35 latest, with 'E' type lock and key ward No. 42,. Th e key and handle should be supplied at the rate of one no. per four Apparatus cases. The 'E' type key lock is as per RDSO Spec.No. IRS;S-30/64 or latest, RDSO drg. No. SA 3376/M or latest and Key is as per Drg. No. 3377/M or latest. Note: Th is item includes the supply of 2 Nos E Type Lock fitted on both doors, along with two Keys.

10

27512

275123.4

... More
Supply of non deteriorating type, Round head type, low voltage cartridge fuse as per Spec No. IRS: S -78/92 with latest amendments, 2A/4A/6A/8A/10A rating capacity

200

123

24640

... More
Supply of Cartridge Fuse block, made of PBT, as per RDSO spec. No. IRS: S-75/2006 (Rev.2) or latest and as per Drawing. No. SA- 23748 (Alt.-4) or latest.

200

243

48732

... More
Supply of Indicative type of fuse inserts with holder, 0.6 Amp, as per IRS S: 78/92 or latest, make Rapid, Malnad, L&T or similar of reputed make . ( Inspection By Consignee).

200

69

13874

... More
Supply of Indicative type of fuse inserts with holder, 1.6 Amp, as per IRS S: 78/92 or latest, make Rapid, Malnad, L&T or similar of reputed make. ( Inspection By Consignee).

200

72

14480

... More
Supply of Indicative type of fuse inserts with holder, 6/10 Amp, as per IRS S: 78/92 or latest, make Rapid, Malnad, L&T or similar of reputed make. (Inspection By Consignee)

200

270

54118

... More
Supply of Indicative type of fuse inserts without holder, 0.6 Amp, as per IRS S: 78/92 or latest, make Rapid, Malnad, L&T or similar of reputed make. ( Inspection By Consignee).

200

21

4340

... More
Supply of Indicative type of fuse inserts without holder, 1.6 Amp, as per IRS S: 78/92 or latest, make Rapid, Malnad, L&T or similar of reputed make . ( Inspection By Consignee).

200

20

4138

... More
Supply of Indicative type of fuse inserts without holder, 6/10 Amp, as per IRS S: 78/92 or latest, make Rapid, Malnad, L&T or similar of reputed make. ( Inspection By Consignee).

-

-

43

... More
Supply of ARA terminal block, made of PBT, as per RDSO spec. No. IRS: S-75/2006 (Rev.2) or latest and as per Drawing. No. SA- 23741A (Alt.-4) or latest.

500

119

59660

... More
Supply of Electrically Operated Lifting Barrier complete set suitable for 110v AC/110 VDC / 24V DC supply, without hand generator back up, and motorized boom locking arrangements as per RDSO Spec.No. SPN/208/2012 Ver. 2.0 or latest.The 02 Nos of Barriers of length 09.76 meter should be supplied along with stop boards and light. The spares & tool kit mentioned in RDSO Spec. 45 No. RDSO/SPN/208/2012 Ver. 2.0 and Amndt. 1 or latest, clause 10.1 & 10.2 reproduced as below should be supplied along with each full set :- i) GI boom - 1 No. complete. ii) Belt - 1 No. iii) Crank handle - 1 No. iv) Motor Contactor - 1 No. v) Motor protection MCB- 1 No. vi) Push button complete- 2 Nos. vii) Limit switch - 3 Nos. (1 lever type and 2 top roller type) viii) Fuses used - 2 sets Tool kit consisting of standard sizes of wrinch / spanner and Allen keys should also be supplied with each set (02 Nos.) of Electric Lift ing barrier."

2

362897

725795.3

... More
Installation, testing and commissioning of electrically operated lifting barrier, complete 46 with casting of cement concrete foundation for pedestal and boom rest post, cabling, power supply connection, earthing of barriers & wiring with complete outdoor work as per approved drawing, wiring etc.

2

55688

111377.24

... More
Supply of Electrical lifting barrier booms of 9.76 meter (32 feet) long, in four section of 8 feet each, as per RDSO spec.No. RDSO/SPN/208/2012 Ver.2.0 or latest and as per RDSO drawing No. RDSO/S/11600 or latest.

4

17202

68810.44

... More
Supply, Installation, testing and commissioning of Sliding type mechanical Boom barrier (SBB) assembly, 11 to 12 meter Long, movement drive mechanism, resetting & supporting 48 stand suitable for Mechanical/Electrical level crossing gate as an emergency arrangements as per GZB Workshop drawing No. SA-SWG/GZB/E/01. The sliding boom assembly should be have the provision of 50mm x 50mm x 50mm angles for the entire length. Boom rest posts should be 10 No. per gate or more as per site requirement. Painting should be completely done of all the assemblies/parts of sliding LC gate.

2

189475

378951.92

... More
Supply, installation and commissioning of complete Electronic LC Gate telephone 49 system, (both master and slave), in 1+6 configuration, with surge protection and power supply system and battery, as per RDSO spec.No. RDSO/SPN/TC/51/2021, Rev. 1.0 or latest. (with Voice logging facility).

1

79108

79108.97

... More
Supply of Dual Tone Bell /Buzzer with Flasher arrangement and 20 Watt horn working on 24 V DC/ 110 V AC for warning road users at LC gates.

1

5861

5861.84

... More
Termination of Outdoor Cables (Main Cables /tail cables) at ARA/Disconnect type 51 terminals provided in Apparatus Cases, Cable termination rack in relay room, station building, generator room etc. Th e item includes dressing of cables and wires with dressing threads as per standard practice. All material required for this item will be supplied by contractor. Th e outdoor cable shall be terminated in Relay Room, DG Room, ASM Room etc under supervision and instructions issued by Engineer incharge of the work.

20000

295400

295400

... More
Excavation, casting, curing of foundation and Installation and Erection of Apparatus case Full (Apparatus Case as per RDSO drg. No. RDSO/S-11500 or latest) with contractor's own frame, 52 cement and other material in the ratio 1:3:6. 'E' type lock to be supplied and installed with Apparatus case. Th is includes fi lling of location foundations with river bed sand and plastering on top with a mixture of 1:4 of cement and sand. It covers fi xing of lamp holder, switch and lamp etc. in Apparatus Case.

30

12277

368334.3

... More
Supply of phenolic laminated Sheet, resin bonded, grade P3 in standard size of 1220 X 1220 x 10 mm as per spec. No. IS 2036 of 1995 or latest. Test report of manufacture to be supplied.

10

5756

57561.4

... More
Fabrication and fixing of phenolic laminated sheet of grade P3, minimum 10 mm thick, as per Apparatus case diagram/plan, in location box by providing all fixtures like ARA/Disconnect terminals, fuse blocks, fuses, relays on square bars etc. including fixing of PVC coated string rods at the back side for cable support with contractor's own material like iron angle, nuts, bolts etc. Th e iron angle for fixing shall be minimum 3 mm thick. Th is also includes fixing of teak wood shelf minimum 25 mm thick for holding track circuit equipments. Th e work shall be done as per instructions of Rly engineer at site. (Apparatus case Full

-

-

54

... More
Fixing of ARA(M-6) Terminals /Screw less connectors / modular disconnect terminal 55 blocks and fuse blocks on phenolic laminated sheets and fixing by stainless steel/brass nuts & bolts. This includes provision of two additional holes on the board on either side for cable conductor entry. The work shall be carried out a per instructions of railway Engineer incharge. (Supply of all above terminals has been covered separately)

10000

18

181100

... More
Supply and installation of earth electrode as per standard practice and as per NCR Drawing No. S&T/CONST/6.4/97. It includes supply of GI pipe of 3 meter length. It includes connecting the earth electrode to the equipments which are required to be earthed including digging of earth pit 3 56 meter deep and fi xing earth electrode pipe, casting of cement concrete enclosure with cover (cover as per drawing No. S&T/CONST/6.3/97. It includes installation of 7 strand GI wires as earth lead wires, supported on MS fl at size 5mm x 40 mm, soldering and nut bolt both, one end of both earth lead wire and MS flat to earth electrode and other end to Location boxes, block equipments, power equipments, cable sheath, signals etc. as per site requirement and as per instructions given by engineer incharge

50

3450

172548

... More
Supply of CO2 type fire extinguisher capacity 4.5 Kg capacity ISI marked, with all 57 accessories, operating temperature (-30)° to (50)° for class 13 B type of fi re with 1 meter long hose pipe fitted with PVC bend horn, with carrying handle and wall mounting bracket, complete in all respect. It should conform to IS 2878:2004. Extinguisher certificate has to be supplied along with the item.

10

5179

51798.1

... More
Supply of 1 x 6 Sq mm (Red/Black/Green) multi strand copper power wire , 85 58 conductor each dia 0.30 +/- 0.01 with insulation thickness of 0.8 mm and nominal conductor resistance of 3.3 ohms/km and test para Mtr.s as per RDSO Specn. No.IRS:S-76/89 (Amnd.3) or latest. Colour of the wire will be specifi ed by the Engineer incharge

1000

47

47970

... More
Supply of 1 x 10 Sqmm (Red/Black/Green) multi strand copper power wire, 101 59 conductor each dia 0.45 +/- 0.01 with insulation thickness of 1.2 mm and nominal conductor resistance of 1.127 ohms/km and test 49 parameters as per RDSO Specn.No.IRS:S-76/89 (Amnd.3) or latest. Colour of the wire which is required will be specified by the Engineer incharge. Inspection

2000

125

251160

... More
Supply of 1 x 16 Sqmm (Red/Black/Green) multi strand copper power wire as per IS: 60 2465/1984 and IS:694:2010 or latest, 101 conductor each dia 0.45 +/- 0.01 with insulation thickness of 1.2 mm and nominal conductor resistance of 1.127 ohms/km and test parameters as per RDSO Specn.No.IRS:S-76/89(Amnd.3) or latest. Colour of the wire which is required will be specifi ed by the Engineer incharge.

1000

147

147770

... More
Supply of 1 x 25 Sqmm (Red/Black/Green) multi strand copper power wire, Colour of the wire which is required will be specified by the Engineer incharg

500

398

199085

... More
Supply of 16/0.2 mm (0.5 sq mm) PVC insulated multi strand, single core, tinned copper conductor, as per RDSO Specn.No.IRS:S-76/89 (Amnd-3) or latest. Each coil should be of 100/200/500 Meters length. Colour of the wire will be specifi ed by the Engineer incharge.

10000

10

108800

... More
Supply, Installation, Testing & Commissioning of Microprocessor based Networkable analog addressable and modular type of fire Alarm Control Panel with display with 2 loop expandable 63 upto four loop ,power supply and battery back up as per RDSO specification no. RDSO/SPN/217/2021 Ver 3.0 or latest. Including GSM module -01 No. for sending SMS to configured mobile number and relay module -02 Nos. for connecting to datalogger for remote monitoring . The panel should support sufficient devices of both detectors and modules in a single line circuit .

1

100285

100285.73

... More
Supply, Installation, Testing & Commissioning of Addressable heat and smoke Multi sensor. As per RDSO specification No. RDSO/SPN/217/2021 Ver 3.0 or latest.

15

3133

47002.35

... More
Supply, installation, testing and commissioning of analog Linear Heat Sensing (LHS) cable as per RDSO Specification No. RDSO/ SPN/ 217/2021 ver3.0 or latest.

500

1084

542175

... More
Supply, Installation, Testing & Commissioning of LHS Interface Module for LHS cable connectivity to control panel As per RDSO/SPN/217/2021 Ver.3 or later.

-

-

66

... More
Supply, Installation, Testing & Commissioning of Aspiration systems with single pipe slot along with required module and power supply, interfacing module etc.As per RDSO specification No. RDSO/SPN/217/2021 Ver 3.0 or latest.

1

290878

290878.16

... More
Supply, Installation, Testing & Commissioning of Analogue Addressable & resettable Manual Call Point with inbuilt short circuit fault isolator (as per RDSO /SPN/217/2021 Ver 3.0 or latest..

1

4303

4303.72

... More
Supply, Installation, Testing & Commissioning of Hooter cum Strobe including its control module As per RDSO specification No. RDSO/SPN/217/2021 Ver 3.0 or latest.

1

7748

7748.34

... More
Supply, Installation, Testing & Commissioning of Fire survival cable 2cX1.5 sqmm (unarmored), (As per RDSO/SPN/217/2021 Ver 3.0. or latest.

100

113

11339

... More
CPVC pipe and all other associated fittings. As per RDSO specification No. RDSO/SPN/217/2021 Ver 3.0 or latest.

100

1180

118012

... More
Supply of Micro Processor based Data Logger System with 1024 digital inputs and 32 analog inputs with protocol converter as per RDSO Spec. No. IRS (S) 99/2006 (Amnd. 3) or latest. It includes supply of all the items required for complete indoor relay room wiring from data logger to 72 relay rack tag blocks, drawing/extension of power supply upto Data Logger. It includes relay room door lock checking arrangement, commercial power supply monitoring arrangement & monitoring of DG sets, ELD, IPS, UFSBI, BI, interlinking and networking of Data logger. Note: Total numbers of relays and other signalling functions/gears required to be wired as per list circulated vide RDSO Letter No. STS/E/Data logger dtd.12.09.2011 or latest guidelines.

1

521440

521440

... More
Installation, testing and commissioning of Micro Processor based Data Logger System with 1024 digital inputs and 32 analog inputs with protocol converter as per RDSO Spec. No. IRS (S) 99/2006 (Amnd. 3) or latest. It includes supply of all the items required for complete indoor relay room wiring from data logger to relay rack tag blocks, drawing/extension of power supply upto Data Logger. 73 It includes relay room door lock checking arrangement, commercial power supply monitoring arrangement & monitoring of DG sets, ELD, IPS, UFSBI, BI, interlinking and networking of Data logger. It also includes installation of leased line MODEM and other interfacing cards, if required for networking of Data Logger. Note: Total numbers of relays and other signalling functions/gears required to be wired as per list circulated vide RDSO Letter No. STS/E/Data logger dtd.12.09.2011 or latest guidelines.

1

98866

98866.67

... More
Supply, Installation and commissioning of active lightning arrestor of Class 'A' for building protection as per standard NFC-17-102 :2011 or latest. It shall work on early streamer 74 emission principle. It shall be made of stainless steel with an operating time of 60 microsecond or less. A Non-resettable counter shall be provided to count the number of lightning occurrence. Th e device shall be installed on top of the building on a GI mast and shall be connected to the earth pit through a copper tape of 25mm x 2mm or better. Th e copper tape shall Not touch the building throughout and shall be connected to the earth electrode by exothermic welding.

2

111652

223304.48

... More
Embedded soft ware modification in (1) FEP in test room and (2) CMU in test room, to accept and transfer the relevant station data to a client PC.

1

119646

119646.47

... More
Testing and Commissioning of the entire system of Datalogger, COA, Data-concentrator etc.

1

56286

56286.79

... More
Supply of USB to Serial converter, of reputed make as Efftronics, MOXA, ATEN or similar.

2

3812

7625.78

... More
Fixing, wiring, testing and commissioning of Electrical Point Machine on the Wooden/PRC sleepers at points as per standard practice and as per section of rails used. Item includes 78 fi xing switch extension bracket, providing insulation for switch extension bracket, fi xing ground connection, adjusting opening of the switches and adjusting the point machine with crank handle. Th e item also includes : (i) Complete material for installation like ground-connections, switch extension brackets, point insulation material, I pipes, wiring materials, various fi xing nuts & bolts including castle nuts, spring washers. (ii) All smithy & fi tting works required at site for complete installation. (iii) Installation of gauge tie plate & providing insulation for gauge tie plate (Insulation in William Stretcher Bar will be provided by Railways). (iv) Wiring inside the point machine, insertion and termination of tail cable in point machine and junction boxes / location box /cable hut as per extent practice on NCR and the instruction of Railway Engineer at site. (v) Supply and fi xing of bend pipes with welded frame for cable entry to machine (vi) Supply and fi lling of industrial grade/good quality lubricant/grease/oil for smooth operation of point machine. Note : Th e ground connections shall be suitable to the Point Machines as pecified by Engineer-in-charge and shall be suitable to the point lay out i.e. 60 Kg. / 52 Kg / 90R as per yard layout. Electrical Point Machine and M-6 / Screw less terminals will be supplied by Railways / covered in Schedule separately.

19

14054

267029.8

... More
Fabrication and supply of point rodding (Ground Connection) set for electric point machine (RDSO Type) as per RDSO Drg. NosA-8800-01, 20-21, 9151- 52,9000-01, 03-04, 9065-66, 9101, as applicable.

19

14771

280650.52

... More
Supply and fixing of GI bend pipe 50 mm dia. 'B'class, for cable entry into Point 80 machine with all accessories. Note: Th is item to be operated independently for those points where Point machines are functional but GI bend pipe is not provided. For all other new installation of Point machines, item 06002 of the SOR includes the provision of GI bend pipe

19

3115

59198.87

... More
Supply of gauge tie plate insulation complete set each set consisting plate T-10372 = 1No., Bush T-10368=3 Nos. and washer - T-10371 = 6 Nos.

200

364

72854

... More
Supply of stretcher bar insulation complete set consisting of the following:- Plate-T- 10367-1 No., Bush T- 10368- 3 Nos. and washer-T- 10371 -6 Nos.

200

363

72768

... More
Q-Series Track Relay (QTA2 Type), AC immunized, 9 Ohms, 2F/1B along with plug 83 board (base plate), connectors, retaining clips etc and conforming to BRS:939A & 966(Appendix F2) or latest and RDSO Specn.No.IRS:S34 S-23 , S-60 or latest, as applicable. The interlocking code for this unit shall be "FGHKX". 84

40

3804

152199.2

... More
Supply of B Type Choke as per RDSO Specn.No.IRS:S-65/83 (Amnd. 3) or latest.

40

5911

236472.8

... More
Supply of Adjustable Track Feed Resistance 30 Ohms (Disc Type), Phenolic moulded base, as per RDSO Drg. No. SA-20161-66/M or latest

40

2280

91232.8

... More
Supply of Track feed Battery Charger as per RDSO Specn. No. IRS: S-89/2013 Ver.1.0 or latest. Charging capacity rating should be suitable for charging 80 AH Battery.

40

5903

236130

... More
Supply of Track Lead Junction Box (TLJB), 4 way, 250 mm x 255 mm x120 mm made from FRP, as per Drg.No. 20101/M(IRS) or latest, including brass bolts and hylam board sheet with terminals etc. Th e FRP material shall be as per RDSO spec.No. RDSO/SPN/151/1997 or latest. Th e 87 technical specifi cations are as follows: (a) TLJB complete with cover to be in black/red/grey with all the holes required for mounting on FRP stump (vertical two for each FRP angle) HDPE pipe, cable etc. (b) Each TLJB shall have two bakellite terminal block fi tted horizontally, each bakellite terminal block shall have two nickel chrome plate with brass terminal. Alongwith each TLJB, nickel chrome plated brass links(two nos. of adequate strength for vertical linking of the terminals to be supplied. (c) HDPE pipe along with two nuts for fi xing on the TLJB hole. (d) Th e FRP stump for mounting the TLJB.

80

5339

427185.6

... More
Supply of Secondary cells 2 V, 80 AH Low Maintenance with topping frequency up to 6 months, as per specification no. IRS: S-88/2004 uncharged complete with inter cell connectors, nuts and bolts etc.

120

3111

373410

... More
"Horizontal direction drilling [HDD]/Trenchless digging/machine drilling with-out damage to surface road /track for laying/insertion of HDPE/GI/DWC pipe. The bore shall be done at the depth of minimum 1400 mm from the ground level. The ground level shall be considered ignoring the bank height of the bank of the road. Note:- DWC/HDPE/GI Pipe Supply is not covered under this item. Contactor shall provide all material required for work and adequate nos. of labours for proper laying of cables into the bore. Cable shall be laid cautiously so that it should not get damage due to rough handling & pressure on cable. Payment of boring shall be made only after DWC/HDPE/GI pipe is laid in the bore.(Inspection by Consignee)"

-

-

89

... More
Supply of Hydrometer, Exide make or similar for measuring specific gravity of Battery Graded acid with mounting stand in location Boxes.

2

355

711.48

... More
Supply of Channel pins, single groove, 7 mm, galvanised, suitable for 4 mm dia bonding wire for Track Circuit rail bonding, as per RDSO spec.No. IRS: S 17-75

500

3

1935

... More
Supply of PVC insulated, jacketed wire rope for Track lead connections. The wire rope should be of galvanised steel, 6 mm dia, (6x19 stranded wire with steel core of 6 mm) sheathed with PVC.

2000

44

88160

... More
"Installation of DC track circuits (Straight Portion) including supply of materials as per directive of site Engineer. Note : (i) Th is includes drilling 9/32"" holes on rails, provision of double continuity GI wire bonding, provision of Block Joints 60 Kg/52 Kg/90R with machined fi sh plates, installation of Track lead junction box (separately for (+) and (-) rails), provision of track lead jumper wires/cables, fixing of track circuit equipment i.e. track charger, resistance, fuses, batteries, chokes, relays, anti-titling arrangement and painting, lettering and numbering of DC track circuit equipments 93 etc., (ii) [a] Un-machined fi sh plates shall be supplied by the Railway's, but machining of fi sh plates shall be done by the Tenderer. In case of provision of Glued Joints by Engineering Department in lieu of RDSO Block joint, the cost of machining of fi sh plates@ 100/- per straight track circuit and @ 500/- per point zone track circuit will be deducted. [b] Th is includes insulation of gauge tie plates, Crossing plates, rod in siding points if required or any other place as instructed by Railway Site Engineer, by Tenderer's insulation materials. Railway will supply Track Charger, B-type choke, Resistance, Un- charged battery, TLJB and relays through a separate schedule/from the stores of railway consignee. These are to be transported to site of work at contractor's cost. Tenderer/ Contractor shall supply any other materials that are required for the work."

19

7718

146651.12

... More
"Installation of DC track circuits (Point zone) including supply of materials as per directive of site Engineer. Note : (i) Th is includes drilling 9/32"" holes on rails, provision of double continuity GI wire bonding, provision of Block Joints 60 Kg/52 Kg/90R with machined fi sh plates, installation of Track lead junction box (separately for (+) and (-) rails), provision of track lead jumper wires/cables, fixing of track circuit equipment i.e. track charger, resistance, fuses, batteries, chokes, relays, anti-titling arrangement and painting, lettering and numbering of DC track circuit equipments 94 etc., (ii) [a] Un-machined fi sh plates shall be supplied by the Railway's, but machining of fi sh plates shall be done by the Tenderer. In case of provision of Glued Joints by Engineering Department in lieu of RDSO Block joint, the cost of machining of fi sh plates@ 100/- per straight track circuit and @ 500/- per point zone track circuit will be deducted. [b] This includes insulation of gauge tie plates, Crossing plates, rod in siding points if required or any other place as instructed by Railway Site Engineer, by Tenderer's insulation materials. Railway will supply Track Charger, B-type choke, Resistance, Un- charged battery, TLJB and relays through a separate schedule/from the stores of railway consignee. Th ese are to be transported to site of work at contractor's cost. Tenderer/Contractor shall supply any other materials that are required for the work."

13

12472

162137.69

... More
Charging of Lead Acid Batteries, 2V, 80 AH, with contractors own battery grade 95 sulphuric acid and distilled water with minimum two charge - discharge cycles, installation of charged batteries in groups & their connection & wiring. Th e work shall be done as per the procedure prescribed by the OEM and extant practice of N.C.Rly and instruction of Engineer-in-charge. Detailed measurements of initial charging shall be recorded jointly by contractor & Rly's site-in-charge

120

247

29672.4

... More
"Supply of basic material to construct unit maintenance free earth as per RDSO specs. No RDSO/SPN/197 Ver 1.0 or latest to achieve a resistance less than 1 ohm. It consist of following. (a)copper bonded steel electrode of minimum 3.0 m lon, minimum 17.0 mm dia with copper bonding thickness of minimum 250 microns and UL listed and marked= 1 no. (b)Earth enhancement material supplied in sealed bags of minimum 10 kg=3 nos. (c)Copper strip of 150x25x6 mmto terminateearth rod=1 no. (d)Copper strip of 300x25x6 mm (MEEB)=1 no. (e)Copper strip of 150x25x6 mm (SEEB)=1 no. (ii) Supply of 35 sq mm multi strandsingle core PVC insulated copper cable as per IS: 694 for connecting main earth electrode to MEEB in the equipment room in duplicate.(minimum 10 meter) (iii)Supply of 16 sq mm multi strand single core PVC insulated copper cable as per IS:694 for connecting MEEB to SEEB and SPD to MEEB (minimum 10 Mtr) (iv)Supply of 10 sq mm multi strand single core PVC insulated copper cable as per IS:694 for connecting various equipment to SEEB (v)Supply of copper lug sleeve for 3/16 cable.(Inspection by Consignee)"

-

-

96

... More
"Installation of unit Maintenance Free Earth to achieve a resistance less than 1 ohm as supplied under item no 145. it includes (i)Digging the earth to the required depth. (ii) Insertion of electrode. (iii)Filling of earth enhancing compound (Aprox 30 kg) (iv) Provision of Exothermic weldconnection to coppertape of 25mmx6mmx150mm to the earth electrodes.All material tools and features required for weld will be arranged by contractor (v)This also includes CC cover 1.5 ftx1.5 ft 1 ft wall thickness 2 inch with cover 3 inchthickness. Cable 35 sqmm/16 sqmm/10sq mmfor connectin earth to busbar,busbar to busbar and busbar to various equipment. Earth electrode of17.20 mm dia and 3.00 meter long high tensile low carbon steel circular roads molecularly bonded with copper and outer surface(Minimum copper bonding thickness of 250 micrones to made requirement of under 97 writer's llaboratories(UL) 467-2007 or latest. Copper strips of 150 mmx25 mmx6 mm to be welded with each earth electrode, Copper strips of 300x 25x 6 mm formain equip-potential busbar, copper strips of 150 mm x 25 mm x 6 mm sub equip- potentialbusbar in Relay room, Power room and panel room. GI strip 25 mm x 2 mm for ring formation of earth pits Earth enhancement material in bags for each Earth Electrode. Inspection chamber of sitwe 300 mmx 300 mmx 300 mm (Inside dimension) of approximate 50 mm thick with pulling hooks to cover the Earth pits. Note:The installation of this item shall be carried out by the contractor as per RDSO spec no RDSO/SPN/197 ver 1.0 or latest.Typical RDSO approved drawing reffered in the RDSO specification document are :(i) SDO/RDSO/E&B/001 for typical installation of Earth,(ii) SDO/RDSO/E&B/002 for typical bonding and earthing connection , (iii)SDO/RDSO/E&B/003 for typical arrangement for earth resistance measurement. Inspection by consignee" 98

10

7276

72769.9

... More
Supply of Steel stool, 1 ft by 1 ft size, 1.5 ft height, laminated top.

20

1267

25345.2

... More
Supply of Digital AC/DC Leakage Clamp on meter, make/model ST-CL360, DCM 39A/Motwane or similar.(Inspection .By Consignee)

2

58267

116535.6

... More
Supply of Digital Clamp Earth tester/meter, with memory storage facility, make Motwane/Meco/Fluke or better.(Inspection .By Consignee).

2

114941

229882.46

... More
Supply, wiring, installation and commissioning of Earth Leakage Detector (ELD) having 101 6 digit counter, 12 Channel bus bar, voltage of 110V/60V/ 24V/12V in AC/DC measurement as per RDSO Spec.No. RDSO/SPN/256/ 2002 or latest. Th is includes supply of fuse terminal strip for incoming power supply wires. Installation to be done on 19 inch sub rack along with insulation resistance meter, remote indication and buzzer in ASM room.

4

175512

702051.44

... More
"Supply of Fuse auto changeover system for Railway Signaling System as per RDSO/SPN/209/2012 Rev.2 or latest for Relay room fuses up to 10 Ampere capacity for 102 12V/24V/60V/110V DC and 110V AC systems. The units shall be mounted on DIN rail in adequate size enclosure as per instructions of Railway site engineer. Two No. of NO+NC contacts shall be provided for remote monitoring. The changeover time shall be less than 1 msec. The audio visual alarm for main and standby fuses shall be provided. One set means set of each fuse."

150

2248

337225.5

... More
Installation wiring testing and commissioning of Fuse auto change over system. This 103 includes provision of common Buzzer & indication at ASM Room & ESM Duty Room and painting of fuse details. Th is also includes fabrication of frame for installation of FACS at Station/ LC gate where installation of relay racks not feasible. One set means set of each fuse.

150

159

23965.5

... More
Supply and installation of Cable Termination(CT) rack as per drawing of NC Railway, complete along with fitting arrangements, wall supports, scaff olding and suitable grouting 104 arrangements and also with arrangement for fi xing four 8-way terminal strips/ Screw less terminals/ARA terminals. The CT rack shall be covered with hylum sheet of minimum 10 mm thickness for fi xing of 8-way terminal strips/ Screw less terminals/ ARA terminals. Supply of 8 way terminal strips/ Screw less terminals / ARA terminals Not covered under this item. Cable termination rack shall be corrosive resistant and powder coated

5

48325

241627.55

... More
Q-Series Line Relay (QNA1 Type),AC immunized, 8F/8B, 24 V DC along with plug board 105 (base plate), connectors, retaining clips etc and conforming to BRS931A and RDSO Specn.No.IRS:S@45"44@ S-23 , S-60 or latest, as applicable. The interlocking code for this unit shall be "ABDGH".

50

4456

222842.5

... More
Supply of Relay-Q series, QN1 neutral Line (Metal to Carbon), DC miniature plugin 24V 106 DC 12F-4B front and back contactscomplete with base, plugboard, retaining clip & connectors PINcode AEDGH conforming to BRS :930, IRS:S 23 & 34 as applicable with latest amendment. (Inspection By RDSO).

50

3950

197528.5

... More
Supply of Relay-Q series, QNA1 neutral Line (Metal to Carbon) AC immunized, DC 107 miniature plug-in 24V DC 12F-4B front and back contacts QNA1 complete with base, plugboard, retaining clip &connectors PIN code AEDGH conforming to BRS : 931A, IRS:S 23 & 34 as applicable with latest amendment.(Inspection By RDSO).

50

3926

196339

... More
Supply of Relay, AC immune, plug-in type, style QBCA1, DC biased point contactor, 2HF-4B Contact, 24 V DC, Code BCEJK, contacts metals to carbon, complete with plug-board, retaining clip and connectors confirming to BRS-943, IRS-S-34 IRS-S-23 [as applicable]. (Inspection By RDSO).

50

6825

341273.5

... More
Supply of Relay- Q-Series Neutral Line Relay (QSPA1 Type), AC immunised, 24VDC, 109 8F/4B along with plug board (base plate), connectors, retaining clips etc and conforming to BRS-933A and RDSO Specn.No. IRS:S-34 S-23, S 60 or latest , asapplicable. The interlocking codefor this unit shall be "ABDEJ". (Inspection By RDSO).

50

6059

302958

... More
Supply of Relay-Q-Series LED ECR (Universal Type i.e. QECX-61), 4F/4B complete with 110 plug board (base plate), connectors, retaining clips etc and conforming to BRS:941ASTS/E /RELAYS/AC LIT LEDSIGNAL/09-2002 , Amdt.-1 or latest and RDSO Spec.No. IRS:S-34 S-23 or latest, as applicable. The interlocking code for this unit shall be"ABDHK".(Inspection By RDSO).

50

6816

340824.5

... More
Q-Series Neutral Line Relay, Non-AC immunised, (QN1 Type), 8F/8B, 24V DC complete 111 with plug board(base plate), connectors and retaining clips etc and conforming to BRS- 930 and RDSO Specn.No.IRS:S-34 ,S-23, S-60 or latest, as applicable. Th e interlocking code for this unit shall be "ABCDF".

50

4066

203333.5

... More
Supply of Key Lock Checking Relay (KLCR) working on 24V DC, AC Immunized, metal to metal, with diff erent ward combinations and contact confi guration 4F/4B with 2 extra ward plates, RDSO spec No. RDSO/SPN/219/2016 Ver 1.0 with Amendment-1 or latest.

6

8026

48161.04

... More
Supply and installation of pre-wired KLCR Box, wooden crank handle lock inside box, 113 with 8 way terminal strips, LEDs of approved type, for fi xing of EKT on wooden board inside box form installating KLCRs/EKTs up to 06 No., including supply of all material like board, handle, hinges, glass sheet etc.

6

13636

81819.12

... More
Supply and Installation of Glass fronted Key box for Crank handle etc. it should be done as per site supervisor instructions.

6

2459

14754.66

... More
Maintenance of Signalling gears required for execution of BCM/TTM/FRM or any other signalling work which includes: (1) Proper dressing of track lead jumpers as required by the Railways before and aft er BCM/TTM/FRM machine working. (2) All cables attended during work to be meggared 115 and all damaged cables due to work to be replaced as per requirement of Railways (3) Preparatory work required for the work of Point renewal, removing, fi xing, installation and testing of rodding set for point machine including all associated gears of mechanical/electrical points as per direction of Railway representative at site. (4) Any other decided by Railways. Th e team to be provided for this work should comprise of: Fitter-1 No., Blacksmith- 1 No., Carpenter/Mason- 1 No. and Helpers- 5 No. (Day = per day per team)

100

3248

324833

... More
Supply of Rechargeable remote area lighting system, USA make Pelican model 9430 RALS or similar

1

100309

100309.74

... More
Dismantling and Releasing of existing Location boxes/Apparatus cases/Jn boxes and other associated S&T fittings. All the released material will be transported to the SSE/Consignee depot.

70

972

68045.6

... More
Dismantling and Releasing of existing Signals (both electrical and Mechanical) and other associated S&T fi ttings like wheel, pulleys, wires, stakes etc. All the released material will be transported to the SSE/Consignee depot.

14

1529

21415.8

... More
Painting of two coats of Enamel paint over one coat of Red Oxide primer aft er scrapping and cleaning of the surface. Paint to be of reputed make Asian/Dulux/ Berger or similar. App. Cases inside and outside to be done by Silver colour. (Apparatus Case Full)

40

681

27278

... More
Painting of two coats of Enamel paint over one coat of Red Oxide primer aft er 121 scrapping and cleaning of the surface. Paint to be of reputed make Asian/Dulux/ Berger or similar. (Point machine and ground connections, Point machine by Black enamel and ground connection by Red oxide)

19

288

5481.69

... More
Painting of two coats of Enamel paint over one coat of Red Oxide primer aft er scrapping and cleaning of the surface. Paint to be of reputed make Asian/Dulux/ Berger or similar. (Main Signal post, base, unit and complete fi ttings)

14

914

12802.44

... More
Painting of two coats of Enamel paint over one coat of Red Oxide primer aft er scrapping and cleaning of the surface. Paint to be of reputed make Asian/Dulux/ Berger or similar. (Shunt Signal post, base, unit and complete fittings)

16

389

6239.2

... More
Lettering and Numbering of all S&T gears like Signals, Loc. Boxes, Pt. Machines, TLJBs, Block joints etc. Each item to be taken as one unit.

300

85

25674

... More
Supply of Insulation resistance tester, 100 Mega ohms, 500V DC, hand generator type. Make Meco/Motwane/Waco or similar

2

17830

35661.36

... More
Supply of Insulation resistance tester, 10 Mega ohms, 100V DC, hand generator type. Make Meco/Motwane/Waco or similar.

2

15692

31384.02

... More
"Supply of Auto changeover Power Panel suitable to change over between three incoming single phase 230V supplies with signaling supply distribution arrangement, voltage sensing 127 relays, MCB's, fuses & contactor Unit as per drawing supplied by Engineer -in- charge i). Item include supply of 10 spare fuses of each type, 1 contactor relay of each type & 1 MCB of each type used in panel. ii). Program switches & wire to be supplied based on current requirement .iii).Th e cabinet of Auto changeover shall be powder coated & compact in size as possible."

1

86137

86137.29

... More
Installation of LT Power Panel/ Power distribution panel/ Auto Changeover Panel,power supply equipments such as Rectifi ers Transformers, Battery chargers etc including mounting on 128 wooden planks/Hylam Sheet and complete wiring for automatic change over arrangement, mounting of Program switches on Bakelite sheet of size 300 mm x 300 mm x 8 mm fi tted to MS angle (size 25mm x 25mm x 5mm) brackets, wiring as per requirements. Necessary wires, lugs & glands to be supplied by Contractor.

1

23578

23578.33

... More
Supply, Installation, Testing and Commissioning of High Availability Single Section digital axle counter (HASSDAC) with Dual sensor system as per RDSO/SPN/177/2012 (Version 3) or latest. Th is includes the supply of High frequency web mounting type Tx coil/Rx coil, VR/PR Box duly wired, Vital relays, PR Relays, Clamp with defl ector plates & hardware, Dual display reset 129 box/monitoring console with auto resetting facility, Surge voltage protection devices and fi lter card to be mounted on DIN rail etc as per OEM for complete installation & testing & commissioning of (HASSDAC) system. Th is include fi xing of track device, relays, wiring, lacing /dressing, cable termination with lug eyelet, drilling holes in rails, Installation of track devices and make it functional along with existing UFSBI/block instrument. Material required other then supply item of HASSDAC shall be arranged by contactor to make it functional. Note: One set of HASSDAC system will include equipment required to monitor One Up line or One Dn line of a full Block Section between two stations.

1

849030

849030.99

... More
Supply, Installation, testing and commissioning of Block Panel BPAC (Block Proving with digital axle counter) using UFSBI as per specifi cation IRS:S-105/2012 (Ver.0) with latest amendment 130 for single line operation. Note: One set will include all equipments viz. SM panel, block telephone-2 No., pre-wired relay rack-2 No., all types of required relays, surge and lightning protection, technical manuals etc. required for one complete Single line Block Section (except DAC).

1

959857

959857.49

... More
Supply of Data Entry terminal for entry of train details by ASM/SM and communicating the same to the CMU via Data logger at station, with latest confi guration as follows: Minimum 21.5 131 inch monitor, Processor i7 (Minimum 12 MB cache, up to 4.7 GHz), Windows 11, 64 bit Operating system, Minimum 1 TB SSD , Minimum 8GB DDR4 RAM, Serial, Ethernet, USB, HDMI ports and SD card reader port. It includes the installation the complete system and communication arrangement and Embedded software modification in Data Logger to communicate with the Data entry terminal of the ASM and pass the information through the Data Logger network

1

198014

198014.56

... More
Installation, wiring, testing and commissioning of all UTS related equipments as per 132 Railway site incharge. It also includes confi guration, programming and interfacing with the existing UTS network at way side station as well as at Router end. All connecting material connectors etc. to be supplied by contractor. Soft -ware programming to be done by OEM/OEM certified engineer.

1

59240

59240.21

... More
Preparation of Station specific Train Arrival and Departure Logics for a six road station or less

1

191940

191940.87

... More
Supply of OFC patch cord/jumper cable,10 m long, with [1]FC/PC/SC/LC connectors on both sides or [2] one end FC/PC/SC/Lc connector and other end compatible to work with STM-1 or as per site requirement. (Inspection by Consignee)

50

1784

89209

... More
Supply of 2.048 Mbps, Managed SHDSL modems, as per RDSO spec. No. RDSO/SPN/TC/80/2020, Rev.2.0 or latest with suitable connector. A pair consists of V.35 and G.703 interfaces. Inspection by Consignee.

5

32937

164687.75

... More
Supply and fixing of 50 pair Krone termination DP duly fitted with disconnection type(Inspection by Consignee)

2

6225

12451.72

... More
Supply and installation of 20 pair CT box with disconnection facility, made of FRP. Or similar(Inspection by Consignee)

10

2212

22124.1

... More
Supply of Universal 2 wire/4 wire way station DTMF control Telephone, as per RDSO spec. No. IRS: TC:82-2005, (with Amd. 3 or latest.

10

5199

51996.4

... More
Supply of Power supply unit for 2W/4W way side control phone equipment along with 12V/7AH sealed maintenance free battery as per RDSO spec.No. TC 72-97 Amendment- 1 or latest.

5

3972

19861.3

... More
Supply of 2 Mbps Router, 2 LAN/4 WAN port, 230V AC operated, as per RDSO spec.No. RDSO/SPN/TC/84/2008 Rev. 0 or latest, along with connecting cables, connectors etc. for connecting to the ethernet devices, of reputed make like Cisco/ Dlink or better.

2

83565

167131.36

... More
Installation, wiring, testing and commissioning of all UTS related equipments as per 141 Railway site incharge. It also includes confi guration, programming and interfacing with the existing UTS network at way side station as well as at Router end. All connecting material connectors etc. to be supplied by contractor. Soft -ware programming to be done by OEM/OEM certified engineer.

1

59240

59240.21

... More
Supply of 20 watts Column speaker with 10 watt tapping, matching transformer and driver unit, make reputed as LBD 8373 of Philips make, SCM-30T of Ahuja make or similar.

20

2851

57021

... More
Supply of 25 watts Industrial Horn speaker with 5, 10, 15, 20 watt tappings, matching transformer and driver unit, make reputed as LBD 8347, 8308 of Philips make, UHC-30XT of Ahuja make or similar.

15

1769

26541.15

... More
Supply, installation, testing an commissioning of 2 core screened/shielded multistrand PVC insulated wire (24/0.2 mm dia) for speaker load line.

1000

48

48650

... More
Installation, Testing and commissioning of 25 watt VHF synthesised transreceiver set, 145 at Raileway station, including all blacksmith and masonry work as per Railway Engineer at site. Required GI pipe shall be supplied by the contractor in size 6 Mtr/1500 mm length, 50 mm/40 mm dia as per requirement at site. Inspection by Consignee.

1

4939

4939.54

... More
Installation of thermo shrink jointing kit as per RDSO Specn.No. IRS: TC 77- 2012 (Rev.3.0) with (Amdt.-1 to 3) or latest, suitable for 6 Quad/jelly filled cables for straight through/derivation joints. It includes supply of all the accessories, without transformer

5

1682

8414.35

... More
Supply of permanently lubricated HDPE duct, 40 mm outer dia, as per RDSO spec. No. RDSO/SPN/TC/45/2013 Rev.2 Amndt.2 or latest, along with all accessories like end caps, collars, bends, couplers etc. (Inspection by Consignee)

1

76811

76811.42

... More
Laying of HDPE duct as per approved cable rtoute plan in the exavated trench/other protected works/RCC channel etc.including all accessories like end caps, co;;ars,bends,couplers 149 etc.The ends of the duct to be sealed with end plugs tillOFC blowing is done.Important: The laying of OFC cable independently or along with Quad cable/PIJFcable in the same trench shall be governed by the RDSO drawings no RDSO/TCDO/COP-6(a) and RDSO/TCDO/COP-8(a) respectively, issued vide chapter-XIII of the telecom manual. (Inspection by Consignee)

1

8092

8092.25

... More
Supply, Installation, testing and Commissioning of on line UPS 5 KVA, with battery of 48AH (8 Nos) of reputed brand, with battery trolley, of reputed make as APC/Uniline etc. or similar.

2

131519

263038.28

... More
Supply of Optical Power Meter, type-B, as per TEC spec. GR/OPM-01/03 Feb. 2005 or latest. (Inspection .By Consignee).

2

17742

35485.22

... More
"Multi section Digital Axle Counter (MSDAC) supply, design, installation, testing and commissioning of Multi section digital axle counter (MSDAC) complete system as per RDSO Specification NO. RDSO/SPN/178/2013 version 3 with latest amendments or latest. Suitable for commissioning of yard/Auto Section/dual detection (DCTC/AFTC with MSDAC), MSDAC should have facility to reset track sectiom. Design of Axle Counter circuit indoor installation testing and commissioning of Multi section digital Axle counter (per unit), supply of essential 10% spares covering all types of cards, wheel sensor for MSDAC. Supply of Diagnostic system for Remote diagnostics Tool set for wheel sensor mounting and maintenance of MSDAC consisting of torque wrench, ratchet, testing plate. measuring tape, screw driver, gloves and multimeter fluke 115 (1 Nos. per 14 DP). ""NOTE:-1. Any housing is required to keep outdoor equipment, it has to be supplied with the equipment with no extra cost. 2. Maintenance free earthing (supply and installation) for track 1 device/mushroom housing etc to be done by the contractor if required by system design. No extra cost/ payment will be made by this Railway: 3. Automatic resetting facilities through hardware software for auto resetting to be provided by contractor by his own materials for this no extra cost /payment will be made by Railways. 4. MSDAC system nerworking to be done with central control room. Required hardware PC/network equipment to be provided by the contractor, no extra cost/payment will be made for this by Railway. El Channel/media will be provided by Railway for this purpose from nearest Railway station. 5. All other Hardware like TPR, Extra card to make dual DP, Modem, ethernet switches etc if required for commissioning and final track section pick up will be supplied by contractor, no extra payment will be made by this Railway. 6 Separate evaluator for UP and Down line to be provided at Station/RII as decided by Railway site engineer. For the communication between evaluator to evaluator (RH to Station) Quad/OFC Link (dark fiber) will be provided by Railway. Any other Networking equipment if required will be supplied by contractor at no extra cost. 7. Manual resetting through reset box at station to be provided as per requirement.

35

318941

11162946.55

... More
"Supply and placing of trunking and capping (RCC Duct) of 500mm Width as per Drg.No.SDO/Cable laying/007 (Annexure-10),as detailed in document No.RDSO/SI/G/2010 Ver.1.1 or latest on 'Guidelines on signalling cable laying, with the following modification Note: ""The bottom thickness increased from 30mm to 40mm duly retaining overall height of 235 mm from ground level by keeping middle partition wall height at 195 mm from top surface of bottom wall of trunking and also to provide 3 nos long steel rods to make reinforcement design of capping to have improvement 1 strength of capping.

500

1546

773190

... More
"Excavation of Cable trench in all kind of soil except hard rocky areas including dearing 2 of roots of trees, rocks, ouches etc., to a depth of 0,5 mtr 0.6 mtr to accommodate the duct under NS item and to a width of 0.5 mtr. This shall include refilling of earth as per Instructions of Engineer Incharge. Laying of cables is not included in this schedule. In case of less depth, payment will be done proportionate to depth subjected to minimum depth of 500 mm.

500

181

90750

... More
Supply, installation and commissioning of Air conditioner (min 2 Ton) Split AC for relay 3 room. It includes supply of Stabilizer, Digital timer change over switch, 30A AC switch with MCB and wiring of all equipment, BEE Star rating of the product, carry 5 star Rating . Godrej or Similar make. Work will be executed as per instruction of site incharge. All material inspected by Consignee. Timer, switch and MCB shall be provided outside the relay room. 4

6

48900

293400

... More
Supply of Data concentrator along with one dual card modem (Inspection by RITES)

1

112088

112088.79

... More
Supply of hand track drill machine (Cycle type) suitable for making holes in rails. Contractor should get the approval of sample from railway engineer.

2

6709

13419.04

... More
Supply of drill twist of size 9/32" (7.2mm) morse taper shank suitable for making holes in the Rails. Contractor should get the approval of sample from Railway Engineer before supply.

50

159

7957.5

... More
Supply of 8 port Gigabit Lite Managed PoE Layer 2 Switch supports 8 nos 10/ 100/ 1000 BASE-T ports, along with 2 Gigabit SFP ports, green-saving technologies, make model DG-GS1510 HPL DIGISOL / CISCO/ JUNIPER or superior (Inspection by consignee)

3

20669

62008.17

... More
Supply,Installation,Testing & commissioning of Aggregate switch(24 x GE SFP ports and 4 x10G SFP+) as per RDSO specification no. RDSO/SPN/TC/65/2021 version 6.0 or latest.(Inspection by Consignee)

1

75000

75000

... More
Supply of 6U outdoor cabinet enclosure IP66 complied pole mount, similar to Rackom 6UIP66 or similar(Inspection by Consignee)

2

8500

17000

... More
Supply and Installation of 6 U height 19" size covered rack with(1) front side transparent door with lock arrangement (2) cable organisers (3)provision of 1 no power supply (each consists of 6 Nos x 15A/5A).(Inspection by Consignee) 11

4

9251

37006.2

... More
Supply of High speed HDMI cable-20 Mtr Length.(Inspection by Consignee)

2

2500

5000

... More
Supply of power cable 3 core,2.5 sq mm , multi strand(36/0.3 mm dia) cable as per IS 694:1990 reaffirmed 1995 or latest suitable for Railway electification area, shall be reputed make like Havells, Delton, LAPP, Finolex or superior. (Inspection by Consignee)

1500

84

126825

... More
Supply of Armoured Outdoor CAT-6 cable [305 Mtrs. Roll] of Make- D-Link, Polycab, Digisol, Finolex or similar. ( Inspection by Consignee). Per unit BOX

4

24170

96682.64

... More
Supply of UTP CAT-6 cable of reputed make Siemen /Systemax / D-link/ Tyco / Krone / AMP or similar.(Inspection by consignee.)

2000

24

49140

... More
Supply of 06 Core Optical Fiber Cable Armoured Single Mode. Make : D-Link or similar of reputed make. (Inspection by Consignee)

1000

30

30530

... More
Supply and installation [splicing of fiber] of Rack Mount LIU 12 Core Loaded with SC Adaptors. Make : D-Link or similar of reputed make. (Inspection by Consignee).

7

7483

52387.37

... More
Laying of Data cable/ Communication cable/ Power cable etc. in PVC conduit pipe with all fiitings and accessories [As per site requirement]. (Inspection by Consignee).

-

-

17

... More
Supply of single mode single fiber 1G SFP+ module compatible with switchd taken in the schedule.(Inspection by Consignee)

40

1000

40000

... More
Supply of single mode single fibre 10G SFP + module compatible with the switch taken in the schedule.(Inspection by Consignee)

4

3125

12500

... More
Supply of PVC Conduit Pipe 25mm ISI marked heavy as per IS 9537 part-III 1983 standard (Inspection by Consignee)

1500

17

25800

... More
Laying & fixing PVC conduit pipe (Conduit pipe must be fixed with clamp at interval of 300 mm) [Inspection by Consignee]

1500

22

33705

... More
Supply,Installation,Testing & commissioning of 3 KVA On Line UPS with isolation 22 transformer suitable for single phase AC input & single phase AC output,floor mounted type of mae APC/Luminious/microtec /liebert/Numeric (with Battery of 48AH (04 Nos) of reputed brand.) (Inspection by Consignee)

2

77299

154598.4

... More
Supply , testing and commissioning of 1 KVA UPS with battery inbuilt. (Reputed Make) (Inspection by Consignee)

2

23220

46441.54

... More
supply , termination, testing & commissioning of RJ-45 connector D-Link make or Similar of reputed make.(Inspection by Consignee.)

200

8

1622

... More
Supply of LAN Extender as per RDSO Specification no. RDSO/SPN/TC/82/2020, Rev.2.0 or Latest. Inspection by Consignee

5

13310

66550.55

... More
Supply,erection,foundation,fixing & commissioning of Hot Dip Galvanised octagonal Pole 5 Mtrs Long cofiring to IS: 2629/BSEN ISO :1416 latest Version. Manufacture should be ISO certified firm(Inspection by Consignee)

3

7868

23604

... More
Supply, installation, testing wiring &commissioning of single mode Media Converter fiber to ethernet as per clause No.16 of RDSO/SPN/TC/2021 Version 6.0 or Latest Inspection by Consignee

5

6178

30891

... More
Description : Supply and installation of 42 U height x 1000m depth x 600mm width covered server Rack at Railway station with (1) front side transparent door with lock arrangement (2) fitted with one number FAN tray with 4 No

2

48505

97011.6

... More
Supply of 50 pair PIJF cable 0.63mm dia Underground armoured polythene insulated polythene sheathed jelly filled telephone cable with poly-Al moisture barrier as per RDSO Specification No. IRS-TC : 41/97 with latest amendments. Accepted brand : Self or similar (Inspection by Consignee)

1

272500

272500

... More
Supply and Installation of PVC channel, with cover of size 50mm x 34 mm of 1 mm thickness. The installation to be done as per instruction of site incharge.(Inspection by Consignee)

400

145

58192

... More
"Supply of Underground 20 Pair PIJF cable 0.5mm dia. as per specification no. IRS:TC- 41/97 with amndt no.-03 or latest.(Inspection by Consignee)

1.5

153320

229980.87

... More
Push button telephone with caller ID , Mute, Redial, Hand free speaker phone, Alpha numeric keyboard,fast dialing keys,Make-Panasonic KX-Ts880MX or similar,Beetel M-90.Inspection by Consignee

15

1834

27523.5

... More
"Removal,shifting, fixing and installation of 5 line LED train Timing Display Board at CPA (a)Construction of 6x3x2 FEEt base with concrete material consisting of good quality cement, iron 33 rods and other required suitable materials(inspection by consignee) (b)05 Line LED Display board will be removed from One Place and fixed on the concrete based structure on a metallic frame 15 feet long xn 2 feet wide All the cost of material,transportation required material, deployment of men power etc shall be bared by the contractor him (Inspection by Consignee) (c) To cover back side and top of the LED board by suitable material for rain safety (Inspection by Consignee)"

1

295000

295000

... More
"Supply of Relay rack, frame, scaffolding and ladder/angle for relay room, power equipment room, batteries room and other places as required, all oven baked and powder coated with Biscuit Mat colour corrosive resistant and final finish with Grey (Sigma) enamelled paint, complete 34 with fuse strip, anodized bars/strip for relay bases, Insulators, grouting bolts, tripods, rack fittings, ladder arrangement, all necessary fitting, supports, insulators, PVC slotted trunking having removable covers.Capacitors, resistors, diodes and other accessories etc. as per drawing and technical specifications & Erection of relay racks with scaffolding arrangement, suitable grounding arrangements, fixing of tag blocks on relay racks and complete all the accessories as per technical specifications.

4

35091

140366.84

... More
Supply of Copper Tape 25x2 mm for interconnection of earth electrodes as per RDSO Drawing SDO/RDSO/E&B/001 OR LATEST

200

417

83496

... More
Supply of Desktop Client Machine: Minimum Specifications: Core i510TH GEN / 8GB DDR3 RAM / 1000 GB HDD /WIN 10/MS office with Full HD monitor 27 Inch,UPS (1KVA with inbuild battery) , One chair and One computer table forData logger, MLK and display of signals.

2

108088

216176.4

... More
Automated BR930 Relay Testor & Conditioner, or better. It shall have feature of contact 37 conditioning (cleaning). Test result to be stored on board for retrieval and are also synchronised to a cloud database providing analysis and reporting tools. Remote data access facility shall be there. It should automatically detects the relay type based on code pins. It shall have the facility to generate and compare the test reports.

2

737500

1475000

... More
Taking the all type of cables inside station relay rooms, location boxes and junction boxes etc. and sealing of cable entry pit etc. as per technical specifications, complete with contractor's material.

100

3664

366456

... More
Loading, Transportation/Carriage and Unloading of various S&T material by a 9 MT truck, from/to the consignee depot to/from various locations, as decided by the Railways

8500

54

464525

... More
"Miscellaneous arrangements for NI period comprising of (a) Temporary goomty/Tent of dimension atleast 12'x12' at both side of the station yard and at central panel building, furnished with one table, six chairs, emergency light and mosquito repellent. (b) Sufficient temporary lighting arrangement throughout the yard from Sunset to sunrise one day prior, during and post NI work. This includes provision of two DG set of minimum 7.5 KVA capacity and halogen flood lights. The DG sets 40 and Diesel etc. has to be arranged by the contractor at his own cost. (c) Provision of PA System at both the end of the yard. (d) Resting arrangement for atleast 16 staff at night. (e) Vehicle for transportation for to and fro movement of S&T staff during NI period. (f) Manning of adjacent station to be done by contractor. (g) Provision of printing/Xerox copies of drawings, wiring diagram, CTR/ Location box terminal chart, point wiring, MSDAC/track circuit wiring, NI program, Signal wiring, track bonding plan, etc. in a plastic folder. No. of copies depends upon the number of team formed for NI and as per instruction of officer incharge of NI. (h) This also includes Free home & Free Starter wiring for NI as per the instruction of site engineer."

1

200000

200000

... More
Provision of vehicles for Supervisors and officers for inspection of work. 2500 KM/month, SUV (Scorpio/Bolero Neo/Innova/ or similar) 42

12

40200

482400

... More
Remote diagnostic and predictive maintenance system.

-

-

6766568.29

... More
Installation of integrated power supply equipments grouting, laddering, wiring & 43 interconnections of power panel, power equipments, programme swiches, busbars fitted on relay racks outgoing supply terminals on CT racks. All the power wires should be terminated with copper lugs (Dowells or similar make) and soldered with contractor's own materials.

1

39595

39595.69



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.