North Central Railway Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

North Central Railway - NCR Tender

Works
Software and IT Solutions
Ireps
Opening Date3 Jan 2025
Closing Date28 Jan 2025
Tender Amount₹ 2,19,18,427.92 
Notes
Download

Costs

Summary

Provision Of Railnet Connectivity In Remaining Section Of Jhansi Division.

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply and Installation of 4 Port GPON OLT with 4*10 G Uplink and 16* Giga 4 Ethernet/SFP Ports. Make :- Zyxel/Alcatel/Siemens/Nokia/Cisco or Similar as per technical specification attached. Note:- Component should be compatible with existing GPON Technology. (Inspection Agency :- Consignee).

1

312627

312627.43

... More
Supply & Installation of (ONT) GPON Class B+,4xGbE LAN,2FXS Port,1USB 2.0,1 UPS 5 port Wi-Fi 11 n 2.4 Ghz 300 mbps,5GHz 11 ac 866 mbps along with connecting accessories and as per Technical Specification attached. Note:- Component should be compatible with existing GPON Technology. (Inspection Agency :- RITES).

100

9643

964392

... More
Supply and installation of NMS for the GPON system with licence along with supply of high end Desktop for installation of NMS as per Technical specification attached.Note:- Component should be compatible with existing GPON Technology. (Inspection Agency :- Consignee).

1

228496

228496.89

... More
Supply of 10 G GPON OLT SFP+Fiber module preferably same make of GPON OLT as per Technical Specification attached.Make :- Zyxel/Alcatel/ Siemens/Nokia/Cisco or Similar branded reputed make. (Inspection Agency :- Consignee).

10

14260

142608

... More
Supply and installation of 8 port Gigabit Lite Managed PoE Layer 2 Switch supports 8 nos 10/100/ 1000 BASE-T ports,along with 2 Gigabit SFP ports, green-saving technologies, make DIGISOL / CISCO/ JUNIPER or superior. (Inspection Agency :- Consignee).

8

18363

146907.44

... More
Supply of indoor managed wireless access point as per Technical Specification attached. Make:-TP-link/Ligowave/Hanutech or compatible with existing system. (Inspection Agency :- Consignee).

5

9361

46809.65

... More
Supply & Installation of fiber patch panel - loaded with 1:4 and 1:8 PLC Spliter Pre terminated with SC/APC connectors and adapters ,Splice tray & adapter plates as per Technical Specification attached. (Inspection Agency :- RITES).

30

18712

561389.7

... More
Supply, Installation and Testing of Single Mode Single Fibre 10 G SFP module of reputed make compatible with switch taken in estimate . (Inspection Agency :- Consignee).

10

6287

62875.2

... More
Supply of Armoured Optical Fiber Cable , 6 Core , Single Mode, single fiber. Make:- D- LINK/Sterlite/Zyxel/Finolex or branded reputed make. (Inspection Agency :- Consignee).

4000

23

95200

... More
Supply of 6 Fiber LIU rack mountable with simplex 6 SC SM adapter and 6 SC-SM Pigtail and splice tray for 12 fiber splice and as per Technical Specification attached.Make:- Legrand/Digisol or branded reputed make. (Inspection Agency :- Consignee).

15

2998

44972.85

... More
Supply and installation of wall mountable 19 ''6 U rack complete with all accessories. (transparent door) make:- Schneider Electric/D-Link/Star Tech or branded reputed make. (Inspection Agency :- Consignee).

5

4080

20401.4

... More
Supply and installation of FMS (12 F-in & out) rack mountable single mode with 15 Suitable type connector with splicing and termination of OFC cables with all accessories (Pig tail and other materials required for work to be supplied by contractor) Make D- Link/Legrand/Digisol/Raycom/Tyco or similar. (Inspection Agency :- Consignee).

10

6139

61394.1

... More
Supply of 24 fiber optical fiber cable straight joint enclosure (SJC) complete with all 16 accessories along with enclosures with heat shrinkable splice protection sleeve as per RDSO spec. RDSO/SPN/TC68/2014 Revision 1.0, Amndt. 1.0 or latest. Splice losses in no case should be more than 0.1 dB. (Inspection Agency :- Consignee).

10

5366

53662.8

... More
Supply and installation of FMS (24 F-in & out ) rack mountable single mode with 17 Suitable type with splicing and termination of OFC cables with all accessories (Pig tail and other materials required for work to be supplied by contractor ) Make D-link ,Raycom, Tyco or similar. (Inspection Agency :- Consignee).

10

8096

80967.4

... More
Supply of permanently lubricated HDPE duct, 40 mm outer dia, as per RDSO spec. No. RDSO/SPN/TC/45/2013 Rev.2 Amndt.2 or latest, along with all accessories like end caps, collars, bends, couplers etc. (Inspection Agency :- RITES).

10

76912

769126.1

... More
Supply and configuration of software for Yard digitization with route setting indications and depicting the train No as per train movement to suit the video wall display. (Inspection Agency :- RITES).

18

245000

4410000

... More
Supply & installation of Train Tracking Supervisory PC. (Inspection Agency :- Consignee).

1

350000

350000

... More
Supply of Centralized monitoring data logger networking system as per RDSO Specification No.IRS: S-99/2006 (Amndt. 3) or latest for centralized acquisition of data from individual 21 remote stations. This includes supply of Multi Front End Processor (FEP) required for data loggers networking as per RDSO specification. The item also covers the supply of PC based Central Monitoring Unit (CMU) with 1 KVA Online UPS along with 3 nos. of battery having 12 V/42 Ah capacity. (Inspection Agency :- Consignee).

1

350000

350000

... More
Supply of 2 core Optical Fiber Cable (Unarmored) for end user connectivity from splitter as per technical specification. Make:- D-LINK Sterlite, Zyxel, Finolex or branded reputed make. (Inspection Agency :- Consignee).

2000

7

15580

... More
Supply of 2 Port Fiber Termination Unit with pigtails.(Inspection Agency :- Consignee).

-

-

23

... More
Supply and fixing of cable route marker of concrete make.The material to be supplied as per NCR approved drawing. (Inspection Agency :- Consignee).

35

392

13720

... More
Supply and installation of online 1 KVA UPS with minimum 3 Nos. 9AH/12V battery or equivalent capacity or higher. Make -Uniline/ Microtek/libert/luminuous or branded reputed make. (Inspection Agency :- Consignee).

8

21684

173473.76

... More
Supply and fixing of PVC FLEXIBLE PIPE of 1" Dia. Make:- AR/Racknsell or branded reputed make. (Inspection Agency :- Consignee).

100

16

1618

... More
Supply and fixing of PVC conduit pipe 25 mm with accessories such as bend ,tee, coupling, elbow, saddle, clamp, screw, PVC/ wooden plugs etc. on walls, angle or on rail of platform 27 shelter etc. MS clamp made of 3 mm MS flat to be manufactured and supplied and fixed to clamp the PVC pipe or angle/ rail run of platform shelter. The clamp should be painted with red oxide primer over which two coats of aluminum paint to be given. Where ever necessary jumper holes to be made in wall and above PVC pipe threaded and wall to be repaired to its original condition. Make:- Polycab/AKG or Finolex. (Inspection Agency :- Consignee).

300

33

9912

... More
Supply and fixing of PVC casing caping of size 1". Make:- AKG or branded reputed make.(Inspection Agency :- Consignee).

200

20

4086

... More
Supply of Double Walled Corrugated pipe size of outer dia 90mm /inner dia 76mm ,having non flame propagation and anti rodent properties, electtrex / telerex / optirex or similar per TEC specification GR / DWC - 34 / 01, IS 14930 with all accessories. (Inspection Agency :- Consignee).

378

218

82532.52

... More
Supply of Patch cord-LC/PC-LC/PC ,5mtr (Connector make:3M/ Huber-Shuner/ R&M/TE Connectivity/Raychem) or branded reputed make. (Inspection Agency :- Consignee).

30

350

10523.1

... More
Supply of OFC patch cord SC to SC of minimum two meter length of reputed branded make. (Inspection Agency :- Consignee).

50

103

5172

... More
Supply of Patch cord LC-SC 3 meters of reputed branded make. (Inspection Agency :- Consignee).

40

157

6300

... More
Supply of OFC Joint box for termination of 2 Core/6 Core/12 Core OFC. (Tiffin box type or similar). (Inspection Agency :- Consignee).

40

165

6624.4

... More
Supply of UTP CAT-6 cable of reputed make Siemen/ Systemax / D-Link/ Tyco/ Krone/ AMP or similar. (Inspection Agency :- Consignee).

2440

23

56949.6

... More
Supply & fixing of I/O box-CAT-6.D-Link make or similar reputed make. (Inspection Agency :- Consignee).

50

260

13013.5

... More
Supply of Fast Ethernet to SFP Media Converter 10/100/1000Mbps with 1.25G DDM 1310/1550nm SFP Module Transceivers SMSF Upto 20KM of Hanutech or similar branded make. (Inspection Agency :- Consignee).

10

6501

65014.7

... More
Supply, installation, testing and commissioning of RJ-45 connector. D Link Make or better. (Inspection Agency :- Consignee).

400

6

2428

... More
Laying of Armoured Optical Fiber OFC through PVC Pipe/Casing capping and termination in LIUs & FDMS with proper clamping etc. wherever required.

500

22

11320

... More
Installation of LIU including splicing of 6 fiber cables as per Technical Specificationattached. 3

10

714

7142.4

... More
Splicing of OFC as per Technical specification attached.

130

103

13483.6

... More
Splicing of 24 core optic fibre cable and making the splicing joint with contractor's own 4 machine and tools. Joint should be prepared in such a way that the top of the enclosure should be at a depth of minimum 1.2 meter and the enclosure should be covered with soft soil and bricks. Splice loss of each fibre should be less than 0.05 dB.

10

8952

89525.3

... More
Construction of OFC jointing pit of size 1mx1mx0.6m, using bricks, sand and cement in 5 the ratio 1:3. The thickness of the wall shall be 120 mm. The top cover shall be of concrete of thickness 75 mm with two iron handles on top of it. The pit shall be covered with sand after putting the joint enclosure. All construction material to be supplied by contractor.

10

6351

63515.1

... More
Laying of HDPE duct as per the approved cable route plan in the exavated trenches/other protected works/RCC channel etc. including all accessories like end caps, collars, 6 bends, couplers etc. The ends of the duct to be sealed with end plugs till OFC blowing is done. Important: The laying of OFC cable independently or along with Quad cable/PIJF cable in the same trench shall be governed by the RDSO drawings no. RDSO/TCDO/COP-6(a) and RDSO/TCDO/COP-8(a) respectively, issued vide Chapter-XIII of the Telecomm Manual.

10

6916

69165.3

... More
Blowing/drawing of OFC cable in the HDPE pipe duct and protective work already 7 provided in the trench. The cable shall be laid only after the successful completion of the DIT (Duct Integrity test). The DIT should be certified by the Railway engineer at site. All the equipments/machinery required shall be arranged by the contractor.

10

14645

146456.8

... More
Identification & Preparation of route wise interlocking logics for Train tracking based on Station Interlocking which includes validation of necessary Signalling relays in datalogger system.

18

265000

4770000

... More
Develop and Customize Auto Train Tracking software specific to control board. This includes development of route algorithms to track the train movement using route, point, signal, track and interlocking data along with real time Datalogger data. 10

18

250000

4500000

... More
Implementation, Testing & commissioning of Train Monitoring software.

1

450000

450000

... More
Installation, testing and commissioning of Centralized monitoring data logger networking system. 12

1

50000

50000

... More
Laying of 2 core OFC drop cable.

2000

4

9800

... More
Concealed wiring for cable. This includes cutting of wall, fixing of conduit cable and plastering of wall to its original condition by Contractor as per direction of site supervisor.

300

189

56895

... More
Laying of DWC pipes along with collars in trenches at places of track and road crossing,platform cutting etc and as per instruction of site engineer depending on the local condition.

378

38

14681.52

... More
Horizontal Boring/Manual moling without damage to surface road /track for laying/isertion of DWC/GI/HDPE pipe. The bore shall be done at the depth of minimum 1400 mm from 15 the ground level. The ground level shall be considered ignoring the bank height of the bank of the road. Note:- DWC/HDPE/GI Pipe Supply is not covered under this item. Contactor shall provide all material required for work and adequate nos. of labours for proper laying of cables into the bore. Cable shall be laid cautiously so that it should not get damage due to rough handling & pressure on cable. Payment of boring shall be made only after DWC/HDPE/GI pipe is laid in the bore.

280

1071

300134.8

... More
Horizontal direction drilling (HDD)/Trenchless digging/machine drilling without damage to surface road /track for laying/insertion of HDPE/GI/DWC pipe. The bore shall be done at the depth of minimum 1400 mm from the ground level. The ground level shall be considered ignoring the bank 16 height of the bank of the road. Note:- DWC/HDPE/GI Pipe Supply is not covered under this item. Contactor shall provide all material required for work and adequate nos. of labours for proper laying of cables into the bore. Cable shall be laid cautiously so that it should not get damage due to rough handling & pressure on cable. Payment of boring shall be made only aft er DWC/HDPE/GI pipe is laid in the bore.

500

616

308175

... More
Excavation of cable trench as per cable route plan, 1.2 Mtr. deep and of 0.3 Mtr. to 0.6 Mtr. wide at bottom as per RDSO sketch No. SDO/CABLE LAYING/003, issued vide RDSO document no. RDSO/SI/G/2010 Version 1.1 dated 04.02.2014 or latest, alongside the track in normal (all type) 17 soil/strata,conforming to distances as per cable route plan and refilling and ramming of loose soil. This work includes clearing of route from bushes etc, covering of cable laid in trench by loose soil for a layer of 50mm thickness approximately before covering by bricks. The work shall be done as per the extant practice on North Central Railway and instructions of Railway Engineer at site. In case 1.2 m depth of trench is not achievable due to site condition, specific approval of JAG/SG officer will be required for each site where trench depth of 1.2 m is not possible,only after approval of JAG/SG officer propotionate payment can be done.

8000

89

717280

... More
Protection of under ground cable by provision of concrete layer in the ratio 1:2:4 havingminimum thickness 100 mmand mimumum width of200mm.

130

184

23925.2

... More
Cutting of all types of platforms/road crossing and trenching and excavation to a width and depth of 300 mm x 300 mm, laying of DWC/HDPE/GI pipe in the trench and refilling and 19 concreting it afterwards as per original condition. In hard rocky ground area , cables will be laid normally on layer of soft earth of 0.05 mtrs thickness previously deposited at bottom of the trench . The cutting to be filled and finished with cement/concrete, as per the RDSO drawing no.SDO/Cable laying/008, issued vide RDSO document no. RDSO/SI/G/2010 Version 1.1 dated 04.02.2014 or latest.

400

159

63632

... More
Preparation of as built final cable route and other plans (for OFC as well as other telecom cable, laying whose is covered in this schedule)tatting into the points mentioned in chapter of technical requirement on Auto CAD for entire sections station. The cable route a other plans shall 20 be prepared by contractor after joint survey, got approved from engineer in charge, changes during course of execution incorporated in the same. After completion of the work all completion documents of tracing papers along with route plan, joints & splicing schedule, cable hut wiring diagramed. in six sets for each station and section in folders shall be supplied by the contractor. Contractor shall also supply the Auto CAD documents on pendrive. All the required materials, accessories including tracings, papers etc, shall be contractor's own.

15

1760

26412.3

... More
Laying of UTP/STP CAT-6 cable/power cable in PVC casing capping of appropriate size. The work also includes supply and fixing of casing and capping, fixing and connection of patch panel, fixing of CAT-6 cable with RJ 45 connectors. Work to be done as per instructions of site incharge.

2440

44

107457.6



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.