North Central Railway Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

North Central Railway - NCR Tender

Goods
Electrical Cables And Wires
Electrical and Electronics
Ireps
Opening Date1 Aug 2024
Closing Date23 Aug 2024
Tender Amount₹ 78,03,057.98 
Notes
Download

Costs

Summary

Electrical General Work In Connection With Development Of Mahoba Railway Station In Jhansi Division Under Amrit Bharat Yojna.

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
"Supply, erection, testing and commissioning of 300 mm sweep exhaust fan suitable on 230 volt AC, supply it should be fixed on wall with reg. bolt nut washer etc., complete with all other accessories required as per site. "

12

2270

27250.08

... More
Supply, erection, testing and commissioning of sub main of 2x6 Sq.mm PVC insulated sheathed copper wire, multi strands, 1100 volts grade, continues PVC insulated sheathed copper earth wire of 1.5 sq mm, through in concealed PVC heavy duty concealed pipe with all other accessories required as per site and removal of existing wiring of sub main if required.

500

96

48370

... More
Supply, erection, Testing & Commissioning ofsub main of 2x4 Sq. mm PVC insulated andsheathed 6 copper wire FRLS/FRLSH, multi strands,110- volts grade,continues PVC insulated sheathed copper earth wire of 1.5 sq. mm, through in concealed PVC heavy duty concealed pipe with all other accessories with J-box ,ceiling rose complete required as per site and removal of existing wiring of sub main if required.

800

70

56424

... More
Supply, erection, testing and commissioning of Wall mounted Sub Distribution board TP&N vertical 7 8 way (8+24) wall mounting type dust and vermin proof indoor type factory fabricated from sheet steel enclosure (1.6mm thick ovory colour) fitted with double door copper busbar, neutral link, earthing terminal detachable glands fitted with following item SDB make as per attached standard list) 01 no. 125 Amp MCCB-FP -For main 08 Nos. 40/25 Amp MCB - DP on outgoing side

1

43417

43417.15

... More
Supply, erection, testing and commissioning of double door type metal clad 12 way SDB with 1x63 Amps. MCB Isolator 2 pole, 4x20/25 Amps. MCB SP, 4x10/16 Amps. MCB SP with all other accessories required as per site.

10

7650

76507.2

... More
Supply, erection, testing and commissioning of Metal clad08 way SDB complete with 40Amps. MCB Dp on I/C side &O/G side 4x20/25 Amps MCBSP, 2x10/16 Amps. MCB SP with all other accessories required as per site.

2

1349

2699.52

... More
Supply erection, testing & commissioning of wall mounted fan 400 mm sweep single phase, 50Hz, 230 Volt AC complete with all other fixing accessories required as per site.

10

2727

27274.8

... More
Supply, Erection, testing and commissioning of Air circulating fan 600mm sweep single phase 50HZ 11 AC 230 V, heavy duty oscillation type propeller fan available with impeller consisting of 03blades column mounting connecting from ceiling rose/ bus bar by 2.5sqmm multi-strands copper wire [FRLS/FRLSH] through PVC flexible pipe (as per IS2997/1964 or latest)

10

6689

66891.4

... More
Supply , testing , erection & commissioning of double door outdoor type LT distribution panels of 16 SWG MS sheet steel ,free floor standing with MS Channel , vermin and dust proof with Siemens gray powder coated paint with cable alleys, locking arrangements, suitable copper busbars & all accessories as per specification comprising of 400A FP On load Change over switch -1 No. Incommer:400A FP adjustable Mangetic 12 and adjustable thermal setting MCCB 35 KA- 2 Nos. , Outgoings:200A FP adjustable mangeticsetting and adjustable thermal setting MCCB 25 KA - 2 Nos ,100A FP fixed mangeticsetting and adjustable thermal setting MCCB 25KA -3 Nos. 63A fixed thermal and fixed magnetic setting FP MCCB 25KA - 5 Nos,Multi data meter - 2 Nos , CT's 400/5, CL-0.5, 15VA 3Nos., RYB indication lamp (LED type) -2Set including all heat shrinkeable sleeves, flexible Cu wires, lugs, sleeves, terminals & PVC troughs as per site condition. * In all outgoing feeder,provision to be made for fixing of digital KWh meter & related CT's"

171605

2

343210

... More
Supply, Erection, Testing and commissioning of colour changing RGB/RGBW LED projector light/ floodlight weather proof with inbuilt DMX chip control, System lumen should be 1100 lm or more, Wattage of luminaire - 22W to 33W complete with all other accessories.(As per specification)

40

6810

272434.4

... More
Supply, Erection, Testing and commissioning of colour changing RGB/RGBW LED projector light/ floodlight weather proof with inbuilt DMX chip control, System lumen should be 1900 lm or more, Wattage of luminaire- 45W to 58W complete with all other accessories.

40

9236

369446

... More
Supply, Erection, Testing and commissioning of colour changing RGB/RGBW LED projector light/ floodlight weather proof with inbuilt DMX chip control, System lumen should be 3200 lm or more, Wattage of luminaire - 85W to 95W complete with all other accessories.

40

12131

485256

... More
Supply, Erection, Testing and commissioning of colour changing RGB/RGBW LED Multiline LINEAR light weather proof with inbuilt DMX chip control, System lumen should be 1700 lm or more, Wattage of luminaire - 50W to 60W complete with all other accessories.

40

8211

328468.8

... More
Supply, Erection, Testing and commissioning of 24 VDC, upto 350 W LED driver as per specification.

25

2371

59289.5

... More
Supply, Erection, Testing and commissioning of 24 VDC, 100 W LED driver as per specification .

80

984

78727.2

... More
Supply, Erection, Testing and commissioning of DMX cable as per requirement.

800

59

47448

... More
Supply, Erection, Testing and commissioning of 2.5 Sqmm copper cable.

2000

21

43580

... More
Supply, Erection, Testing and commissioning of Heavy duty conduit 20 mm dia with all accessories: ISI mark

2000

16

32460

... More
Supply, Erection, Testing and commissioning of Lightning Controllers:- DMX splitter lightning Controllers with all other acessories firm has to submit warranty certificate for 5 years warranty.

120

11864

1423729.2

... More
Supply, Erection, Testing and commissioning of MS protective cage size for spikes as required with lighting fixture including civil Works for protect facade light/projector light.

120

940

112897.2

... More
Supply, erection, testing and commissioning of 50 mm dia GI pipe 3000mm class B confirming to 25 IS: 1239 latest complete with earth box including connection for earth electrode to MDB/SDB single earth electrode pole with 8 SWG GI wire depth earthing arrangement as per IE rules & Rly. Drawing for suitable earth resistance value and all other accessories required as per site. ( technical specification attached in tender document.)

30

2675

80266.5

... More
Supply, erection testing and commissioning of 400Amps on load with SS enclosure type- 4 pole changeover complete with all fixing accessories as per site requirement.

4

34244

136978.52

... More
Supply errection testing and commissioning of 2*18 watt 4 feet LED tube light and fitting with fixture connecting wire and all other fixing accessories required as per site.

250

1360

340172.5

... More
Supply, erection, testing and commissioning ofEnergy efficient BLDC fan, 1200 mm Sweep,25-32 wattage capacity, Single Phase 230 V, 50Hz AC with electronic regulator & all accessories.

50

2701

135058

... More
Supply, erection, testing &commissioning of(36-42) watt, 2'x2' LED panel light & fittings complete with required connecting wire and all other fixing accessories required as per site.

60

3082

184937.4

... More
Supply, Erection, testing & commissioning of energy efficient LED Pole light/Flood light luminary 60- 70 Watt capacity with luminous efficacy 100 made from pressure die cast aluminum housing, toughened front glass co ver, fitted with secondary optics, heat sink and integrated electronic driver for long life with IP 65 30 Protection suitable for working on 240 Volt, 50 Hz AC supply. The price shall also co ver for fixing, testing and commissioning of the abo v e fitting on pole/truss/roof/wall by fabrication by suitable clamp/bracket made from G.I. flat of 40 x 6 mm approx duly painted with nut, bolts and washers of 12 mm diameter as per site requirement. The connection shall be carried out through ISI marked, PVC insulated, flexible three-core copper wire from the existing ceiling rose /catenaries/junction box as per site conditions. The connection cord shall be protected by suitable size of heavy duty flexible PVC conduit

52

3766

195852.8

... More
Excavation of cable trench in soft morrum plain ground concrete/pucca surface etc and back filling of cable for laying of HT/LT cables including placing of bricks incross position etc.

1500

73

109905

... More
Laying/Cleating of LT cable 03/04 core on wall with all accessories ( Cable will be supplied by Rly. Free of cost at consignee depot).

2000

36

72660

... More
Connections with 40 x 6mm Copper strip as per IS: 3043/1987 (Latest version) in 50mm dia G.I. pipe class-B, 300mm deep in ground/recessing in floor as per drawing approve by Railway including supply of material as per relevant technical specification (latest version).

8

782

6263.52

... More
Supply and laying of HDPE pipeof 110mm outer dia PE-80, PN-6(wall thickness :6.3 mm to7.2mm) with proper jointing ,bends, clamps etc., as per site condition with all necessary accessories.

500

306

153490

... More
Drilling of bituminous road/track and laying cherges of cable in road crossing for laying 110mm dia HDPE pipe through it.

300

331

99453

... More
Supply and erection of Octagonal galvanised steel pole double arm 6 meters with base plate 37 220x220x12 mm , top 70mm and bottom 130mm of 3 mm thick sheet suitable for maximum wind speed upto 160km/hr including foundation bolt and foundation with M 20 grade RCC and FE 415 grade reinforcement (450x450x800 cm deep) (foundation should be as per design approved by pole manufacture). Sqm per

26

11149

289877.38

... More
Dismantling and removal of LT existing Rail/Tubular poles and refilling the same excavated earth and finishing the surface in the original condition after removal the existing rail/tubular poles And handed over to concerning depot STORE.

16

287

4604.64

... More
Supply and erection of stay sets complete with end termination by providing stay rod .anchor plate ,stay insulator ,double screwed tighter ,or stay wire ,clamps, nut -bolt etc.

16

1734

27753.28

... More
SUPPLY, INSTALLATION, TESTING &COMMISSIONING OF LED BASE STATION NAME BOARDS :- (Technical specification / salient features for LED name board ) :- 1.Power supply System:- It should be as under. Input: 230 Volt single phase A.C ± 5% Output : 12 Volt D.C. 2. a) name boards shall be made in English, Hindi & Urdu languages. b) Substrate material used for the front portion of channel letter shall be 3mm thick Acrylic sheet frosted or milk white (0/40). c) letter size 24-28" and width of letter should be in proportionate tothe height d) Depth of each letter should be less than 2.5 e)Back of letter should be of sun pack sheet or 28 SWG powder coated sheet. f) Front & Back of letters should be assembled in such a fashion that it remains water tight, 41 Dust proof .g) Front& Back of letters should be jointed / tighten with steel screwand washers, so that it may be opened in case of failure or for maintenance. h) All letters of each location should be fitted suitably on 3mm thick ALUMINUM PANEL Sheet and background shall be dark blue, if Required and this sheet to be fixed suitably on above M.S. Structure. i) Complete name board should be fixed on a M.S. Iron frame structure suitable size to withstand the wind pressure etc.). M.S. Structure should be grouted well with appropriated cement, concrete mixture at given Location. (Note 1:- LED Signage boards station name in03 languages Hindi, English & Urdu. and N.C. Railway will be also add in each board at top side in the half size of station name letters .Note 2:- signage board should be covered with suitable MS Jaali encloser or any suitable transparent flat cover for the protection from animals, birds etc). Design will be approved by the Dy CEE/GSU/JHS

1

83993

83993.48

... More
Supply, erection, testing &commissioning of weather proof100 Watt LED Flood light/Area light 42 fittings with bracket, clamps (complete) IP ratings65/66 and standard PVC flexible pipe, 2.5 sqmm wire for connection & 1.5 sqmm wire for earthing connection of the fittings. Complete with all other accessories required as per site.

16

5614

89837.6

... More
Supply of materials & making wiring points for mobile charging with 2.5 sqmm (FRLS)PVC insulated multi stranded copper conductor cable single core conforming to IS : 694(latest version) in concealed PVC conduit 43 pipe heavy duty 2 mm thickness ISI mark with 5A Modular switch ,modular sheet cover on front of in recessed MS box /On surface modular box with brass screws ,cup washers etc including earth continuity copper wire of 1.5sq.mm PVC insulated copper wire. ( Note:- 01 Board contain 04 Nos mobile charging points with ON/OFF switch. The mobile charging points should be apart at a suitable distance on the single board complete with suitable stand for holding of mobile set etc.)

18

358

6449.4

... More
"Supply, erection, testing & commissioning of 16meters High Mast of 8 arms in two sections suitable for 39m/second 180 kmph wind speed, with raising and lowering system comprising, headframe, luminaries in symmetrical arrangement, double drum winch, 6 mm diameter SS wire rope, trailing cable 5 core, connector, integral power tool motor ,manual handle, junction box, lighting, supply of 400 W LED flood light fitting - 44 8Nos. per Mast, aviation light single dome, supply of outdoor type feeder pillar box with 16 SWG GI sheet powder coated, comprising of 36 A or higher TPN MCB C Series as incomer, single dial time switch,25A or higher TP Contactor for automatic switching of luminaries, power tool control with 2 Nos. of 9A Contactor and raise lower push button, construction of suitable foundation with M20 grade concrete for erection of High mast at site along with supply of foundation bolts, Fixing and wiring of luminaries using 3core 1.5 sqmm copper wire, 5 core 2.5 sq mm trailing cable, earthing with 3 meters GI Pipe 50mm C Class-2Nos. per Mast and connecting of earthing with 25*3 mm GI Flat, installation of feeder pillar by grouting the stand in concrete."

1

342083

342083.5

... More
Shifting work of DG set/Transformers/ LT /HT Panels Re installation, commissioning and testing of all (foundation not included) with provision of tripping arrangement through control circuit.

1

25256

25256.3

... More
Shifting of the High mast from one place to other place and installation and commissioning of this High mast including foundation other necessary items which required for commissioning of the high mast.

1

148449

148449

... More
Handling,Loading,transportation & unloading of material (MTx KM) as per site requirement.

1000

7

7810

... More
Supply, erection,testing and commissioning of sub main of 2x10Sq.mm PVC insulated sheathed 48 copper wire, multistrands, 1100volts grade,continues PVC insulated sheathed copper earth wire of 1.5 sq mm,through PVC heavy duty conduit pipe/PVC Channel complete with all other accessories required as per site and removal of existing wiring of sub main if required. ( Also inclusive Removal of existing submain if required )

100

130

13000

... More
Shifting of Flag mast from one place to other place and installation and commisioning of this Flag 49 mast including foundation other necessary items which required for commissioning of the Flag mast including suitable shallow foundation with 1:2:4 concrete ratio for the flag mast considering the safe soil bearing capacity at site as 10/ton per sqmtr at 2 mtr depth with all materials and labour(Foundation as per Drawing attached).

1

148449

148449

... More
Supply, erection,testing and commissioning of 1.1kv grade LT XLPE insulated aerial bunched cable (ABC) of size (3x120 + 1x95 + 1x16) sqmm with bare messenger wire as per IS:14255-1955 or latest.

600

281

168726

... More
Supply, erection,testing and commissioning of I-Hook with other accessories required as per site.

30

99

2982.3

... More
Supply, erection,testing and commissioning of Dead ended clamp and other accessories required as per site.

10

393

3932.5

... More
Supply, erection,testing and commissioning of suspension clamp with GI bracket (rail pole/tubular pole) and other accessories required as per site.

30

370

11119.2

... More
Supply, erection,testing and commissioning of Piercing connector 90/120 sqmm and other accessories reqiured as per site.

10

273

2732.6



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.