North Central Railway Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

North Central Railway - NCR Tender

Civil And Construction
Railway
Water Storage And Supply
Ireps
Opening Date31 Dec 2021
Closing Date21 Jan 2022
Tender Amount₹ 1,63,86,874 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
RAIN WATER HARVESTING & TUBEWELLS // Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level. // Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. // 200 mm nominal size dia

65

1066

69293.25

... More
RAIN WATER HARVESTING & TUBEWELLS // Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, 5 preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level. // Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. // 200 mm clamp

1

1691

1691.15

... More
RAIN WATER HARVESTING & TUBEWELLS // Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, 6 preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level. // Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: // 200 mm dia

1

280

280.95

... More
RAIN WATER HARVESTING & TUBEWELLS // Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, 7 preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level. // Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge.

25

1497

37442.5

... More
RAIN WATER HARVESTING & TUBEWELLS // Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 8 150 metre depth below ground level. // Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge.

150

857

128640

... More
EARTH WORK // Earth work in excavation by mechanical means (Hydraulic excavator) / manual 9 means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. // All kinds of soil.

190

252

47937

... More
EARTH WORK // Excavating trenches of required width for pipes, cables, etc including excavation 10 for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : // All kinds of soil // Pipes, cables etc, not exceeding 80 mm dia.

875

223

195125

... More
CONCRETE WORK // CEMENT CONCRETE (CAST IN SITU) // Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : // 1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size)

110

6259

688501

... More
MASONRY WORK // Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : // Cement mortar 1:4 (1 cement : 4 coarse sand)

28

7809

218659

... More
FLOORING // 62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) 14 and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture's specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.

60

854

51258

... More
REINFORCED CEMENT CONCRETE // CAST IN SITU // Providing and laying in position specified 15 grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : // 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size)

4

7718

30873

... More
CONCRETE WORK // CEMENT CONCRETE (CAST IN SITU) // Centering and shuttering including strutting, propping etc. and removal of form work for : // Foundations, footings, bases for columns

5

284

1424.25

... More
REINFORCED CEMENT CONCRETE // FORM WORK // Centering and shuttering including strutting, propping etc. and removal of form for // Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

8

609

4874.4

... More
REINFORCED CEMENT CONCRETE // CAST IN SITU // Reinforced cement concrete work in walls 18 (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : // 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size)

9

9306

83754

... More
REINFORCED CEMENT CONCRETE // FORM WORK // Centering and shuttering including strutting, propping etc. and removal of form for // Suspended floors, roofs, landings, balconies and access platform

20

693

13861

... More
REINFORCED CEMENT CONCRETE // FORM WORK // Centering and shuttering including strutting, propping etc. and removal of form for // Lintels, beams, plinth beams, girders, bressumers and cantilevers

13

552

7176.65

... More
REINFORCED CEMENT CONCRETE // STEEL REINFORCEMENT // Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. // Hot rolled deformed bars

2000

83

167000

... More
FINISHING // CEMENT PLASTER (IN FINE SAND) // 12 mm cement plaster of mix : // 1:4 (1 cement: 4 fine sand)

325

266

86726.25

... More
STEEL WORK // Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.

200

86

17210

... More
WOOD AND P.V.C. WORK // Providing and fixing panelled or panelled and glazed shutters for 24 doors, windows and clerestory windows, fixing with butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately) // Second class teak wood // 30 mm thick shutters

5

3269

16349.25

... More
WOOD AND P.V.C. WORK // ANODISED ALUMINIUM FITTINGS (ALL FITTINGS SHALL BE ISI 26 MARKED) // Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : // 150x10 mm

3

75

225

... More
WOOD AND P.V.C. WORK // Providing and fixing panelled or panelled and glazed shutters for 27 doors, windows and clerestory windows, fixing with butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately) // Float glass panes // 4 mm thick glass pane (weight not less than 10kg/sqm).

1

1792

1792.55

... More
WOOD AND P.V.C. WORK // ANODISED ALUMINIUM FITTINGS (ALL FITTINGS SHALL BE ISI 28 MARKED) // Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : // 125 mm

18

59

1073.7

... More
FINISHING // INTERIOR FINISHING // White washing with lime to give an even shade : // New work (three or more coats)

100

28

2855

... More
FINISHING // Colour washing such as green, blue or buff to give an even shade : // New work (two or more coats) with a base coat of white washing with lime

75

38

2921.25

... More
FINISHING // EXTERIOR FINISHING // Applying priming coat: // With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood)

6

57

342.3

... More
FINISHING // Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : // Two or more coats on new work

15

121

1823.25

... More
DISMANTLING AND DEMOLISHING // Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. // In cement mortar

8

1469

11759.2

... More
WATER SUPPLY // C.I. SLUICE VALVES/ FIRE HYDRANTS & FIXTURES // Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately) : // 100 mm diameter // Class I

8

3977

31820.8

... More
WATER SUPPLY // C.I. SLUICE VALVES/ FIRE HYDRANTS & FIXTURES // Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately) : // 150 mm diameter // Class I

8

5836

46692.8

... More
WATER SUPPLY // C.I. SLUICE VALVES/ FIRE HYDRANTS & FIXTURES // Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately) : // 200 mm diameter // Class I

6

11357

68146.5

... More
WATER SUPPLY // C.P.V.C. PIPES // Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, i/c making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall : // 15 mm dia nominal bore

200

447

89520

... More
WATER SUPPLY // C.P.V.C. PIPES // Providing and fixing G.I. Pipes complete with G.I. fittings and 38 clamps, i/c making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall : // 20 mm dia nominal bore

400

494

197640

... More
WATER SUPPLY // C.P.V.C. PIPES // Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc.-Internal work - Exposed on wall // 20 mm dia nominal bore

400

344

137640

... More
WATER SUPPLY // C.I. SLUICE VALVES/ FIRE HYDRANTS & FIXTURES // Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : // 20 mm nominal bore

20

261

5223

... More
WATER SUPPLY // C.P.V.C. PIPES // Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc.-Internal work - Exposed on wall // 25 mm dia nominal bore

300

438

131400

... More
WATER SUPPLY // BRASS FITTINGS // Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : // 15 mm nominal bore

20

338

6774

... More
WATER SUPPLY // C.P.V.C. PIPES // Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.-External work // 50 mm dia nominal bore

1500

565

847875

... More
WATER SUPPLY // C.P.V.C. PIPES // Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.-External work // 80 mm dia nominal bore

1400

866

1212960

... More
WATER SUPPLY // AIR VALVE & WATER METER (BULK TYPE) // Providing and laying Double Flanged (screwed / welded) Centrifugally (Spun) Cast Iron, Class B (IS : 1536) : // 100 mm dia C.I. Double Flanged Pipe

1500

1827

2740650

... More
DISMANTLING AND DEMOLISHING // Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge : // 15 mm to 40 mm nominal bore

400

108

43260

... More
EARTH WORK // Excavating trenches of required width for pipes, cables, etc including excavation 47 for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : // All kinds of soil // Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia

60

364

21852

... More
DISMANTLING AND DEMOLISHING // Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. // Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix)

6

1072

6436.8

... More
CONCRETE WORK // CEMENT CONCRETE (CAST IN SITU) // Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : // 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)

6

6788

40731.6

... More
WATER SUPPLY // AIR VALVE & WATER METER (BULK TYPE) // Providing and laying Double Flanged (screwed / welded) Centrifugally (Spun) Cast Iron, Class B (IS : 1536) : // 150 mm dia C.I. Double Flanged Pipe

500

2861

1430975

... More
WATER SUPPLY // AIR VALVE & WATER METER (BULK TYPE) // Providing push-on-joints to Centrifugally (Spun) Cast Iron Pipes or Ductile Iron Pipes including testing of joints and the cost of rubber gasket : // 150 mm dia pipes

300

149

44955

... More
WATER SUPPLY // AIR VALVE & WATER METER (BULK TYPE) // Providing push-on-joints to Centrifugally (Spun) Cast Iron Pipes or Ductile Iron Pipes including testing of joints and the cost of rubber gasket : // 100 mm dia pipes

100

91

9165

... More
ROAD WORK // ROADS // Supplying and stacking at site. // 53 mm to 22.4 mm size stone aggregate

10

1749

17497.5

... More
DRAINAGE // STONE WARE PIPES AND FITTINGS // Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : // 100 mm diameter

200

317

63410

... More
DRAINAGE // STONE WARE PIPES AND FITTINGS // Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : // 150 mm diameter

2

500

1000.4

... More
DRAINAGE // Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. 57 grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: // Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : // 150 mm dia. R.C.C. pipe

150

462

69390

... More
DRAINAGE // Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. 58 grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: // Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : // 300 mm dia. R.C.C. pipe

12

863

10363.8

... More
DISMANTLING AND DEMOLISHING // Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. // Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)

25

1737

43436.25

... More
ROAD WORK // MISCELLANEOUS // Providing and laying Dense Graded Bituminous Macadam using crushed stone aggregates of specified grading, premixed with bituminous binder and filler, transporting the hot mix to work site by tippers, laying with paver finisher equiped with electronic sensor to the required grade, 1 level and alignment and rolling with smooth wheeled, vibratory and tandem rollers as per specifications to achieve the desired compaction and density, complete as per specificatons and directions of Engineer-in-Charge. // 50 to 100 mm average compacted thickness with bitumen of grade VG-30 @ 5% (percentage by weight of total mix) and lime filler @ 2% (percentage by weight of Aggregate) prepared in Batch Type Hot Mix Plant of 100-120 TPH capacity.

150

10064

1509637.5

... More
ROAD WORK // Providing and applying tack coat using bitumen emulsion conforming to IS:8887, using emulsion pressure distributer including preparing the surface & cleaning with mechanical broom. // Providing and laying Bitumen Penetration Macadam with hard stone aggregate of quality, size and grading as specified, with bitumen of suitable penetration grade, including required key aggregate as specified, spreading 2 coarse aggregate with the help of self propelled/ tipper tail mounted aggregate spreader and applying bitumen by a pressure distributor and then spreading key aggregate with the help of aggregate spreader complete, including consolidation with road roller of minimum 8 to 10 tonne capacity to achieve specified values of compaction and surface accuracy : // For 75 mm compacted thickness in two layers using stone aggregate of size 63-41 mm graded @ 0.90 cum per 10 sqm key aggregate of size 20.0 mm graded @ 0.18 cum per 10 sqm. With paving asphalt grade VG - 10 @ 68 kg/10 sqm.

200

572

114470

... More
ROAD WORK // ROADS // Supplying and stacking at site. // 53 mm to 22.4 mm size stone aggregate

30

1749

52492.5

... More
ROAD WORK // ROADS // Supplying and stacking at site. // Stone screening 11.2 mm nominal size (Type B)

20

1978

39570

... More
ROAD WORK // PREMIX CARPET // Providing and applying tack coat using hot straight run 6 bitumen of grade VG - 10, including heating the bitumen, spraying the bitumen with mechanically operated spray unit fitted on bitumen boiler, cleaning and preparing the existing road surface as per specifications : // On W.B.M. @ 0.75 Kg / sqm

500

42

21025

... More
ROAD WORK // PREMIX CARPET // Providing and applying tack coat using hot straight run 7 bitumen of grade VG - 10, including heating the bitumen, spraying the bitumen with mechanically operated spray unit fitted on bitumen boiler, cleaning and preparing the existing road surface as per specifications : // On bituminous surface @ 0.50 Kg / sqm

2500

33

84125

... More
ROAD WORK // MISCELLANEOUS // Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with 8 cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge).

30

8376

251284.5

... More
ROAD WORK // MISCELLANEOUS // Providing and laying 60mm thick factory made cement 9 concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in- charge.

200

859

171870

... More
CONCRETE WORK // CEMENT CONCRETE (CAST IN SITU) // Providing and laying cement 10 concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: // 1:2:4 (1 Cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)

32

8554

273744

... More
ROAD WORK // ROADS // Preparation and consolidation of sub grade with power road roller of 8 11 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres.

800

156

125400

... More
ROAD WORK // ROADS // Extra for compaction of earth work in embankment under optimum moisture conditions to give at least 95% of the maximum dry density (proctor density).

800

18

14560

... More
ROAD WORK // ROADS // Supplying and stacking at site. // Good earth

100

483

48390

... More
ROAD WORK // MISCELLANEOUS // Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, 14 thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. // 80 mm thick C.C. paver block of M-30 grade with approved color design and pattern.

30

953

28590

... More
ROAD WORK // MISCELLANEOUS // Providing and applying 2.5 mm thick road marking strips (retro- reflective) of specified shade/ colour using hot thermoplastic material by fully/ semi automatic thermoplastic 15 paint applicator machine fitted with profile shoe, glass beads dispenser, propane tank heater and profile shoe heater, driven by experienced operator on road surface including cost of material, labour, T&P, cleaning the road surface of all dirt, seals, oil, grease and foreign material etc. complete as per direction of Engineer-in-charge and accordance with applicable specifications.

100

607

60730

... More
MASONRY WORK // Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: // Cement mortar 1:4 (1 cement : 4 coarse sand)

45

6376

286931.25

... More
FINISHING // CEMENT PLASTER (IN FINE SAND) // 12 mm cement plaster of mix : // 1:4 (1 cement: 4 fine sand)

400

266

106740

... More
MASONRY WORK // Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : // Cement mortar 1:4 (1 cement : 4 coarse sand)

27

7809

210849.75

... More
EARTH WORK // Earth work in excavation by mechanical means (Hydraulic excavator) / manual 19 means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. // All kinds of soil.

30

252

7569

... More
EARTH WORK // Excavating trenches of required width for pipes, cables, etc including excavation 20 for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : // All kinds of soil // Pipes, cables etc, not exceeding 80 mm dia.

30

223

6690

... More
CONCRETE WORK // CEMENT CONCRETE (CAST IN SITU) // Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : // 1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size)

10

6259

62591

... More
ROAD WORK // CONCRETE PAVEMENTS // Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size) in pavements, laid to required slope and camber in panels as required including consolidation finishing and tamping complete.

15

6840

102612.75

... More
DISMANTLING AND DEMOLISHING // Disposal of building rubbish / malba / similar unserviceable, 23 dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.

330

138

45820.5

... More
DISMANTLING AND DEMOLISHING // Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. // In cement mortar

14

1469

20578.6

... More
REINFORCED CEMENT CONCRETE // CAST IN SITU // Providing and laying up to floor five level 25 reinforced cement concrete in kerbs, steps and the like excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).

1

8962

8962.7

... More
REINFORCED CEMENT CONCRETE // STEEL REINFORCEMENT // Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. // Hot rolled deformed bars

1100

83

91850

... More
STEEL WORK // Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.

2440

101

248270

... More
DRAINAGE // Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. 28 grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: // Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : // 300 mm dia. R.C.C. pipe

30

863

25909.5

... More
ROAD WORK // MISCELLANEOUS // Manufacturing, supplying and fixing retro reflective overhead signage boards made up of 2 mm thick aluminium sheet, face to be fully covered with high intensity and 29 encapsulated lens type heat activated retro reflective sheeting conforming to type - III of ASTM-D-4956-01 as approved by Engineer-in-charge, letters, borders etc. as per IRC : 67-2001 in silver white with blue colour back ground and with high intensity grade, pasted on substrate by pressure sensitive adhesive backing which shall be activated by applying pressure conforming to class II of ASTM-D-4956-01 and fixing the same to the plate of structural frame work by means of suitable sized aluminium alloys, rivets or bolts & nuts @ 300 mm centre to centre all along the periphery as well as in two vertical rows along with theft resistant measures, including the cost of painting with two or more coats of epoxy paint in grey colour on the back side of aluminium sheet including appropriate priming coat. The rate includes the cost of rounding off the corners, lowering down the structural frame work from the gantry, fixing and erecting the same in position all complete as per drawings, specification and direction of the engineer-in-charge.(Structural frame work including M.S. plate to be provided separately. Rectangular area of the sheet only shall be measured for payment). // Overhead informatory road signage

40

5284

211378

... More
DISMANTLING AND DEMOLISHING // Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : // Of area 3 sq. metres and below

8

274

2196

... More
DISMANTLING AND DEMOLISHING // Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.

120

39

4680

... More
DISMANTLING AND DEMOLISHING // Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. // For thickness of tiles above 25 mm and up to 40 mm

130

85

11141

... More
DISMANTLING AND DEMOLISHING // Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. // For thickness of tiles 10 mm to 25 mm

20

54

1097

... More
ALUMINIUM WORK // Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary 34 filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : // For fixed portion // Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)

30

423

12718.5

... More
ALUMINIUM WORK // Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. 35 Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : // For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) // Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)

20

513

10268

... More
ALUMINIUM WORK // Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required 36 including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : // Providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge. (Only weight of grill to be measured for payment).

3

519

1559.55

... More
WOOD AND P.V.C. WORK // Providing and fixing panelled or panelled and glazed shutters for 37 doors, windows and clerestory windows, fixing with butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately) // Float glass panes // 5.0 mm thick glass panes (weight not less than 12.50 kg/sqm).

4

2116

8467.6

... More
WOOD AND P.V.C. WORK // ANODISED ALUMINIUM FITTINGS (ALL FITTINGS SHALL BE ISI 38 MARKED) // Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : // 150x10 mm

30

75

2250

... More
DISMANTLING AND DEMOLISHING // Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. // Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)

2

1737

3474.9

... More
DISMANTLING AND DEMOLISHING // Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.

1

2534

2534.7

... More
DISMANTLING AND DEMOLISHING // Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of: // Asbestos Cement sheet

30

56

1707

... More
DISMANTLING AND DEMOLISHING // Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead.

800

4

3320

... More
MASONRY WORK // HALF BRICK MASONRY // Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. // Cement mortar 1:3 (1 cement :3 coarse sand)

20

956

19132

... More
MASONRY WORK // HALF BRICK MASONRY // Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry.

20

80

1602

... More
WOOD AND P.V.C. WORK // GYPSUM BOARD PARTITIONS // Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. // 75 mm

30

47

1416

... More
WOOD AND P.V.C. WORK // Providing and fixing 25 mm thick shutters for cup board etc. : // 46 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: // 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws

20

1819

36396

... More
WOOD AND P.V.C. WORK // Providing and fixing 25 mm thick shutters for cup board etc. : // Extra for Providing and fixing flush doors with decorative veneering instead of non decorative ISI marked flush door shutters conforming to IS: 2202 (Part I) // On one side only

40

441

17660

... More
WOOD AND P.V.C. WORK // MISCELLANEOUS-WOOD WORK // Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete. // With 2nd class teak wood beading 62X19 mm

15

1133

17000.25

... More
WOOD AND P.V.C. WORK // BRASS FITTINGS // Providing and fixing 50 mm bright finished brass cup board or wardrobe knob of approved quality with necessary screws.

15

62

940.5

... More
WOOD AND P.V.C. WORK // BRASS FITTINGS // Providing and fixing special quality bright finished brass cupboard or ward robe locks with four levers of approved quality including necessary screws etc. complete. // 40 mm

15

251

3768

... More
WOOD AND P.V.C. WORK // BRASS FITTINGS // Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete.

15

106

1600.5

... More
WOOD AND P.V.C. WORK // MISCELLANEOUS-WOOD WORK // Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete : // Kiln seasoned and chemically treated hollock wood // 50x20 mm

300

173

51945

... More
CLADDING WORK // STONE WORK DRY CLADDING // Providing 50x50x50 mm 2nd class teak wood plugs including cutting brick work and fixing in cement mortar 1:3 (1 cement : 3 fine sand) and making good the walls etc.

20

33

678

... More
WOOD AND P.V.C. WORK // ANODISED ALUMINIUM FITTINGS (ALL FITTINGS SHALL BE ISI 54 MARKED) // Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : // 250x16 mm

14

231

3243.8

... More
FINISHING // Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : // Two or more coats on new work

800

121

97240

... More
FINISHING // Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification. // Two or more coats on new work

300

87

26145

... More
FINISHING // EXTERIOR FINISHING // Finishing walls with Acrylic Smooth exterior paint of required shade : // New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)

200

164

32940

... More
STEEL WORK // Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. // Hot finished welded type tubes

150

143

21517.5

... More
FINISHING // Providing and applying 12 mm thick (average) premixed formulated one coat gypsum 59 lightweight plaster having additives and light weight aggregates as vermiculite/ perlite respectively conforming to IS: 2547 (Part - 1 & II) 1976, applied on hacked / uneven background such as bare brick/ block/ RCC work on walls & ceiling at all floors and locations, finished in smooth line and level etc. complete.

100

342

34285

... More
REPAIRS TO BUILDING // ROUTINE MAINTENANCE WORK // Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25 degrees celsius, 0.87-0.89 kg/ litre and viscocity 60 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc, and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23 degrees celsius as 650/ 450N/ 5cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 150 degrees celsius. Cold flexibility shall be upto -2 degrees celsius when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane : // 3 mm thick

250

535

133750

... More
STEEL WORK // Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.

100

86

8605

... More
REINFORCED CEMENT CONCRETE // CAST IN SITU // Reinforced cement concrete work in walls 62 (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : // 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size)

5

9306

46530

... More
CONCRETE WORK // CEMENT CONCRETE (CAST IN SITU) // Centering and shuttering including strutting, propping etc. and removal of form work for : // Retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc.

50

609

30465

... More
FLOORING // VITRIFIED FLOOR TILES // Providing and laying Vitrified tiles in different sizes 65 (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. // Size of Tile 500x500 mm

250

1313

328275

... More
ROOFING // Providing, fixing and embedding sand cast iron accessories for rain water pipes in the 66 masonry surrounded with 12 mm thick cement mortar of the same mix, as that of masonry (lead caulking will be paid for separately): // Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. // 110 mm diameter

60

305

18303

... More
ROOFING // Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. // Bend 87.5 degrees // 110 mm bend

4

129

519.4

... More
ROOFING // Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. // Coupler // 110 mm

3

117

353.4

... More
FLOORING // VITRIFIED FLOOR TILES // Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 69 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). // Size of Tile 500x500 mm

10

1501

15012.5

... More
FLOORING // CERAMIC GLAZED TILES // Providing and laying rectified Glazed Ceramic floor tiles 70 of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.

80

1088

87072

... More
REPAIRS TO BUILDING // Making the opening in brick masonry including dismantling in floor or 71 walls by cutting masonry and making good the damages to walls, flooring and jambs complete, to match existing surface i/c disposal of mulba/ rubbish to the nearest municipal dumping ground, all complete as per direction of Engineer-in-Charge. // For door/ window/ clerestory window

2

932

1864.9

... More
CLADDING WORK // Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of 72 required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. // Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. // Granite work

30

376

11287.5

... More
FLOORING // VITRIFIED FLOOR TILES // Providing and laying Vitrified tiles in different sizes 73 (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. // Size of Tile 800x800 mm

14

1806

25295.2

... More
SANITARY INSTALLATIONS // Providing and fixing water closet squatting pan (Indian type W.C. 75 pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: // White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests

1

5421

5421.5

... More
SANITARY INSTALLATIONS // Providing and fixing white vitreous china pedestal type water closet 76 (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : // W.C. pan with ISI marked white solid plastic seat and lid

2

5260

10521.9

... More
SANITARY INSTALLATIONS // Providing and fixing wash basin with C.I. brackets, 15 mm C.P. 77 brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: // White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps

2

2846

5693.8

... More
ROOFING // Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. // Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) 78 total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.

60

627

37653

... More
SANITARY INSTALLATIONS // Cutting chases in brick masonry walls for following diameter sand 79 cast iron/centrifugally cast (spun) iron pipes and making good the same with cement concrete 1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 12.5 mm nominal size), including necessary plaster and pointing in cement mortar 1:4 (1 cement : 4 coarse sand) : // 100 mm dia

30

555

16659

... More
NEW TECHNOLOGIES AND MATERIALS // REPAIR AND REHABILITATION ITEMS // Providing, 80 mixing and applying SBR polymer (of approved make) modified Cement mortar in proportion of 1:4 (1 cement: 4 graded coarse sand with polymer minimum 2% by wt. of cement used) as per specifications and directions of Engineer-in-charge. // 25 mm average thickness in 2 layers.

150

471

70650

... More
NEW TECHNOLOGIES AND MATERIALS // REPAIR AND REHABILITATION ITEMS // Providing, 81 mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer-In-charge complete in all respect. // SBR Polymer (@10% of cement weight) modified cementitious bond coat @ 2.2 kg cement per sqm of surface area mixed with specified proportion of approved polymer

150

117

17595

... More
NEW TECHNOLOGIES AND MATERIALS // REPAIR AND REHABILITATION ITEMS // Chipping of 82 unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge // 25 mm average thickness

150

96

14475

... More
EARTH WORK // Earth work in excavation by mechanical means (Hydraulic excavator) / manual 1 means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. // All kinds of soil.

40

252

10092

... More
EARTH WORK // Excavating trenches of required width for pipes, cables, etc including excavation 2 for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : // All kinds of soil // Pipes, cables etc, not exceeding 80 mm dia.

50

223

11150

... More
CONCRETE WORK // CEMENT CONCRETE (CAST IN SITU) // Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : // 1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size)

9

6259

56331.9

... More
MASONRY WORK // Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: // Cement mortar 1:4 (1 cement : 4 coarse sand)

18

6376

114772.5

... More
MASONRY WORK // Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : // Cement mortar 1:4 (1 cement : 4 coarse sand)

28

7809

218659

... More
CONCRETE WORK // DAMP-PROOF COURSE // Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand(zone-III) : 4 graded stone aggregate 20mm nominal size).

9

418

3770.1

... More
ROAD WORK // ROADS // Supplying and stacking at site. // 53 mm to 22.4 mm size stone aggregate

9

1749

15747.75

... More
FLOORING // 62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) 8 and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture's specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.

120

854

102516

... More
REINFORCED CEMENT CONCRETE // CAST IN SITU // Providing and laying in position specified 9 grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : // 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size)

1

7718

7718.25

... More
CONCRETE WORK // CEMENT CONCRETE (CAST IN SITU) // Centering and shuttering including strutting, propping etc. and removal of form work for : // Foundations, footings, bases for columns

12

284

3418.2

... More
REINFORCED CEMENT CONCRETE // FORM WORK // Centering and shuttering including strutting, propping etc. and removal of form for // Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

12

609

7311.6

... More
CONCRETE WORK // CEMENT CONCRETE (CAST IN SITU) // Centering and shuttering including strutting, propping etc. and removal of form work for : // Columns, piers, abutments, pillars, posts and struts

3

733

2201.1

... More
REINFORCED CEMENT CONCRETE // CAST IN SITU // Reinforced cement concrete work in walls 13 (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : // 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size)

6

9306

55836

... More
REINFORCED CEMENT CONCRETE // FORM WORK // Centering and shuttering including strutting, propping etc. and removal of form for // Lintels, beams, plinth beams, girders, bressumers and cantilevers

9

552

4968.45

... More
REINFORCED CEMENT CONCRETE // STEEL REINFORCEMENT // Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. // Hot rolled deformed bars

800

83

66800

... More
FINISHING // CEMENT PLASTER (IN FINE SAND) // 12 mm cement plaster of mix : // 1:4 (1 cement: 4 fine sand)

250

266

66712.5

... More
STEEL WORK // Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.

800

86

68840

... More
WOOD AND P.V.C. WORK // Providing and fixing panelled or panelled and glazed shutters for 19 doors, windows and clerestory windows, fixing with butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately) // Second class teak wood // 30 mm thick shutters

10.8

3269

35314.38

... More
WOOD AND P.V.C. WORK // Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes, including ISI marked M.S. pressed butt hinges bright 20 finished of required size with necessary screws. // Providing and fixing factory made laminated veneer lumber glazed shutter conforming to IS: 14616 and TADS 15:2001 (Part B), using 4 mm thick float glass panes for doors, windows and clerestory windows, fixing with butt hinges bright finished of required size with necessary screws, all as per directions of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately) // 30 mm thick shutters

6

2572

15435

... More
WOOD AND P.V.C. WORK // ANODISED ALUMINIUM FITTINGS (ALL FITTINGS SHALL BE ISI 21 MARKED) // Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : // 150x10 mm

8

75

600

... More
WOOD AND P.V.C. WORK // Providing and fixing panelled or panelled and glazed shutters for 22 doors, windows and clerestory windows, fixing with butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately) // Float glass panes // 4 mm thick glass pane (weight not less than 10kg/sqm).

7.56

1792

13551.68

... More
WOOD AND P.V.C. WORK // ANODISED ALUMINIUM FITTINGS (ALL FITTINGS SHALL BE ISI 23 MARKED) // Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : // 125 mm

10

59

596.5

... More
FINISHING // Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification. // Two or more coats on new work

150

87

13072.5

... More
FINISHING // EXTERIOR FINISHING // Finishing walls with Acrylic Smooth exterior paint of required shade : // New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)

90

164

14823

... More
FINISHING // EXTERIOR FINISHING // Applying priming coat: // With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood)

42

57

2396.1

... More
STEEL WORK // Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.

300

101

30525

... More
FLOORING // VITRIFIED FLOOR TILES // Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 29 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). // Size of Tile 500x500 mm

20

1501

30025

... More
FLOORING // CERAMIC GLAZED TILES // Providing and laying rectified Glazed Ceramic floor tiles 30 of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.

12

1088

13060.8

... More
CONCRETE WORK // CEMENT CONCRETE (CAST IN SITU) // Providing and laying cement 31 concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: // 1:2:4 (1 Cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)

3

8554

25663.5

... More
FINISHING // Extra for plastering: // Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.

120

196

23604

... More
ROOFING // Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring 33 conforming to IS : 5382, leaving 10 mm gap for thermal expansion. // Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. // 110 mm

1

288

288.8

... More
ROOFING // Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. // Bend 87.5 degrees // 110 mm bend

1

129

129.85

... More
ROOFING // Providing, fixing and embedding sand cast iron accessories for rain water pipes in the 35 masonry surrounded with 12 mm thick cement mortar of the same mix, as that of masonry (lead caulking will be paid for separately): // Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. // 110 mm diameter

16

305

4880.8

... More
DRAINAGE // STONE WARE PIPES AND FITTINGS // Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : // 150 mm diameter

12

500

6002.4

... More
ROOFING // SHEET ROOFING // Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. 37 limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. // 1.00 mm thick with zinc coating not less than 275 gm/sqm

70

1234

86397.5

... More
DISMANTLING AND DEMOLISHING // Demolishing R.C.C. work by mechanical means and stockpiling at designated locations and disposal of dismantled materials up to a lead of 1 kilometre, stacking serviceable and unserviceable material separately including cutting reinforcement bars.

18

2130

38340

... More
FINISHING // Providing and applying 12 mm thick (average) premixed formulated one coat gypsum lightweight plaster having additives and light weight aggregates as vermiculite/ perlite respectively conforming to IS: 2547 (Part - 1 & II) 1976, applied on hacked / uneven background such as bare brick/ block/ RCC work on walls & ceiling at all floors and locations, finished in smooth line and level etc. complete.

45

342

15428.25

... More
DISMANTLING AND DEMOLISHING // Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. // In cement mortar

17

1469

24988.3

... More
DISMANTLING AND DEMOLISHING // Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. // Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)

3

1737

5212.35



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.