North Central Railway Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
North Central Railway - NCR Tender
Civil And Construction
Civil Works Others
Ireps
Opening Date4 Dec 2024
Closing Soon27 Dec 2024
Tender Amount₹ 1,86,57,610.48
Costs
EMD
₹ 2,43,300Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
JHS-TD-TENDER-2024-03R1-JHANSI DIVISION-ELECTRICAL/NORTH CENTRAL RLYTender No
JHS-TD-TENDER-2024-03R1Tender Authority
North Central Railway ViewPurchaser Address
-Website
http://ireps.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Monthly Maintenance of 25kv Feeder Circuit Breaker bay at TSS/SP/SSP. (EACH BAY) 2
220
3544
779823
... More
Yearly Maintenance of 25kv Feeder Circuit Breaker bay at TSS/SP/SSP. (EACH BAY)
20
6396
127922.2
... More
Half Yearly Maintenance of 25kV Single Pole Isolator at TSS 2
66
1721
113589.3
... More
Yearly Maintenance of 25kV Single Pole Isolator at TSS 3
66
2039
134607
... More
Half Yearly Maintenance of 132kV or 66kV Double Pole/Triple Pole Isolator at TSS 4
40
2383
95348.4
... More
Yearly Maintenance of 132kV or 66kV Double Pole/Triple Pole Isolator at TSS
40
3020
120807.2
... More
Fortnightly Maintenance of Battery & Battery chargers at TSS 2
96
1500
144064.32
... More
Monthly Maintenance of Battery & Battery chargers at TSS 3
64
1505
96379.52
... More
Quarterly Maintenance of Battery & Battery chargers at TSS 4
24
2067
49623.36
... More
Yearly Maintenance of Battery & Battery chargers at TSS
8
2327
18618.96
... More
Half yearly Maintenance of AC & DC Distribution panel and Control & Relay panel at TSS. (EACH TSS)
42
3059
128503.62
... More
Quarterly Maintenance of Capacitor bank bay at TSS 2
16
5064
81026.4
... More
Half Yearly Maintenance of Capacitor bank bay at TSS 3
8
6133
49066
... More
Yearly Maintenance of Capacitor bank bay at TSS
8
7066
56532
... More
Monthly Maintenance of 25kv Interrupters at TSS/SP/SSP 2
1480
1962
2905106.8
... More
Half Yearly Maintenance of 25kv Interrupters at TSS/SP/SSP 3
148
2067
306010.72
... More
Yearly Maintenance of 25kv Interrupters at TSS/SP/SSP
148
2523
373449.88
... More
Yearly Maintenance of Earthing station at TSS/SP/SSP
1292
143
185466.6
... More
Fortnightly Maintenance of Battery & Battery chargers at SP/SSP 2
360
1132
407682
... More
Monthly Maintenance of Battery & Battery chargers at SP/SSP 3
240
1132
271788
... More
Quarterly Maintenance of Battery & Battery chargers at SP/SSP 4
90
1586
142829.1
... More
Yearly Maintenance of Battery & Battery chargers at SP/SSP
30
1647
49437.3
... More
Monthly Maintenance of Auxiliary Transformer 2
2720
716
1949668.8
... More
Half Yearly Maintenance of Auxiliary Transformer 3
272
1533
417022.24
... More
Yearly Maintenance of Auxiliary Transformer
272
3562
969073.44
... More
Yearly Maintenance of gantry at TSS/SP/SSP (EACH POST)
38
12364
469862.4
... More
Checking of buried rail by excavation and refilling and painting of buried rail in normal soil
269.28
80
21706.66
... More
TSS (8hrs) 2
24
3376
81044.88
... More
SP/SSP (8Hrs) 3
90
2295
206623.8
... More
AT (8Hrs) 4
1632
2294
3745391.04
... More
Manning of switching stations in case of failure of SCADA, VIP movement & OFC Block 5
360
1366
492109.2
... More
Removal and re erection of PSI Equipments 6
4
5047
20191.76
... More
Reclamation of Fire Extinguisher 7
410
75
31147.7
... More
Spares required for attending the breakdowns
1
500000
500000
... More
Hiring of 2 Nos. Multi Utility Vehicles for regular maintenance, inspection and 1 restoration of failures in case of breakdown including cost of fuel, lubricants, major/minor repairs, salary of driver, toll tax, all other tax, complete operation and maintenance including monthly running upto 2000 KM (24 hrs per day without any rest/holidays) for a period of 24 months (Mahindra Bolero Camper, Tata Xenon, Isuzu Dmax, Isuzu S-Cab, Isuzu V-Cross).
48
42720
2050560
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%