North Central Railway Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
North Central Railway - NCR Tender
Civil And Construction
Civil Works Others
Ireps
Opening Date17 Dec 2024
Closing Soon8 Jan 2025
Tender Amount₹ 4,92,25,720.87
Costs
EMD
₹ 3,96,100Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
JHS-TD-TENDER-2024-11R-JHANSI DIVISION-ELECTRICAL/NORTH CENTRAL RLYTender No
JHS-TD-TENDER-2024-11RTender Authority
North Central Railway ViewPurchaser Address
-Website
http://ireps.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Monthly Maintenance of 25kv Feeder Circuit Breaker bay at TSS/SP/SSP. (EACH BAY) 2
506
3544
1793592.9
... More
Yearly Maintenance of 25kv Feeder Circuit Breaker bay at TSS/SP/SSP. (EACH BAY)
46
6396
294221.06
... More
Half Yearly Maintenance of 25kV Single Pole Isolator at TSS 2
198
1721
340767.9
... More
Yearly Maintenance of 25kV Single Pole Isolator at TSS 3
198
2039
403821
... More
Half Yearly Maintenance of 132kV or 66kV Double Pole/Triple Pole Isolator at TSS 4
100
2383
238371
... More
Yearly Maintenance of 132kV or 66kV Double Pole/Triple Pole Isolator at TSS
100
3020
302018
... More
Fortnightly Maintenance of Battery & Battery chargers at TSS 2
240
1500
360160.8
... More
Monthly Maintenance of Battery & Battery chargers at TSS 3
160
1505
240948.8
... More
Quarterly Maintenance of Battery & Battery chargers at TSS 4
60
2067
124058.4
... More
Yearly Maintenance of Battery & Battery chargers at TSS
20
2327
46547.4
... More
Half yearly Maintenance of AC & DC Distribution panel and Control & Relay panel at TSS. (EACH TSS)
110
3059
336557.1
... More
Quarterly Maintenance of Capacitor bank bay at TSS 2
52
5064
263335.8
... More
Half Yearly Maintenance of Capacitor bank bay at TSS 3
26
6133
159464.5
... More
Yearly Maintenance of Capacitor bank bay at TSS
26
7066
183729
... More
Monthly Maintenance of 25kv Interrupters at TSS/SP/SSP 2
6420
1962
12601882.2
... More
Half Yearly Maintenance of 25kv Interrupters at TSS/SP/SSP 3
642
2067
1327424.88
... More
Yearly Maintenance of 25kv Interrupters at TSS/SP/SSP
642
2523
1619965.02
... More
Yearly Maintenance of Earthing station at TSS/SP/SSP
2312
143
331887.6
... More
Fortnightly Maintenance of Battery & Battery chargers at SP/SSP 2
744
1132
842542.8
... More
Monthly Maintenance of Battery & Battery chargers at SP/SSP 3
496
1132
561695.2
... More
Quarterly Maintenance of Battery & Battery chargers at SP/SSP 4
186
1586
295180.14
... More
Yearly Maintenance of Battery & Battery chargers at SP/SSP
62
1647
102170.42
... More
Monthly Maintenance of Auxiliary Transformer 2
5600
716
4014080
... More
Half Yearly Maintenance of Auxiliary Transformer 3
560
1533
858575.2
... More
Yearly Maintenance of Auxiliary Transformer
560
3562
1995151.2
... More
Yearly Maintenance of gantry at TSS/SP/SSP (EACH POST)
82
15456
1267392
... More
Checking of buried rail by excavation and refilling and painting of buried rail in normal soil
768.24
80
61927.83
... More
TSS (8hrs) 2
60
3376
202612.2
... More
SP/SSP (8Hrs) 3
186
2295
427022.52
... More
AT (8Hrs) 4
3360
2294
7711099.2
... More
Manning of switching stations in case of failure of SCADA, VIP movement & OFC Block 5
744
1366
1017025.68
... More
Removal and re erection of PSI Equipments 6
8
5047
40383.52
... More
Reclamation of Fire Extinguisher 7
920
75
69892.4
... More
Spares required for attending the breakdowns
1
1000000
1000000
... More
Hiring of 5 Nos. Multi Utility Vehicles for regular maintenance, inspection and 1 restoration of failures in case of breakdown including cost of fuel, lubricants, major/minor repairs, salary of driver, toll tax, all other tax, complete operation and maintenance including monthly running upto 2000 KM (24 hrs per day without any rest/holidays) for a period of 24 months (Mahindra Bolero Camper, Tata Xenon, Isuzu Dmax, Isuzu S-Cab, Isuzu V-Cross).
120
42720
5126400
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%