North Central Railway Tender

... More
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of etender.up.nic.in - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.

North Central Railway - NCR Tender

Works
Electrical Goods and Equipments
Electrical and Electronics
Ireps
Opening Date4 Mar 2025
Closing Date27 Mar 2025
Tender Amount₹ 6,14,456.75 
Notes
Download

Costs

Summary

Electrical General Work Related To Ips And Battery Room At Rundhi, Sholaka, Hodal And Chhata Station In Connection With Augmentation Of Power Supply & Reliability Improvement Work. By Shifting S&t Cables In Chhata- Palwal Section Of Agra Division.

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply, erection, Testing & Commissioning of sub main consisting of 2x4 Sq. mm (P & 1 N) PVC insulated and sheathed copper wire multristanded single core 1.1 KV grade alongwith 1.5 Sq. mm PVC insulated copper wire 1.1 KV grade for earthing. (Quantity 1 Mtr. Equal to 02 Nos., wire of 4 Sq.mm of 01 Mtr.each. and 01 No. earth wire 1.5 Sq. mm. of 01 M) (No cable joint is permitted inside the MS/PVC conduit pipe cable should be jointed with cable connectors inside the switch board

160

67

10776

... More
Supply, Erection, Testing and commissioning of MS/PVC conduit pipe 25mm dia and 1 1.6mm thick, recessed in the wall and through the wall by making hole and replastering the same in original condition complete with Tee, elbow, junction box, sadle & Other accessories for sub main wiring

100

43

4371

... More
Supply, Erection, Testing and commissioning of Single earth electrode of 50mm dia 3000mm long GI Pipe class B conforming to IS: 1239 latest complete with earth box including connection from earth electrode to MDB/SDB/poles/With 8 SWG GI Wire

4

2939

11758.36

... More
Supply, Erection, Testing & Commissioning of luminaire complete with all accessories 1 , 18/20 watt, 04 feet LED tube light fitting & Tube with suitable current control driver circuit, suitable for surface mounting and connection with PVC copper flexible wire of 23/76 as per Rly. specification attached

80

485

38837.6

... More
Supply, Erection, Testing and Commissioning of wall mounted Sub Distribution borad 1 SP&N vertical single phase wall mounting type dust and vermin proof indoor type factory fabricated from sheet steel enclosure (1.6mm thick ivory colour) fitted with double door copper bus bar, neutral link, earth terminal detachable glands fitted with following item(SDB make as per attached approved list) 01 No. MCB-DP-40Amp on incomming side 06 Nos. MCBSP-32Amp on outgoing side

4

6374

25499.2

... More
Excavation of cable trench:- This itemshall be operated in conformity with IS:1255 (latestversion) i.e. code of practice for installation andmaintenance of HT/LT cables. The price shall cover costof excavation of cable trench in all type of soil for layingLT cables and back filling the same with sieved earthand finishing the surface in its original condition afterproviding sand, & bricks 1 in cross position. For LT/HTcables the trench shall be 600mm wide x 1000mm deep.In trench the cable shall be covered with river sand at adepth of 100mm below the cable and 100mm above thecable than placing well-burned bricks continuously incrossposition through out the cable route in the ground.The bottom of the trench should level free from stonesand sharp edge of rocks etc. At the termination a loop of5 meter (approx) cable shall be kept as allowance andloops rings be formed as per the site condition, in theground, The cost shall include the cost of all materialsi.e. sand, bricks, cable route markers (grouted in the earth firmly with cement concrete so that it can not be uprooted by miscreants) etc at 25m. interval and eachturn of the cable

600

68

40872

... More
Laying/Cleating erection, Testing &Commissioning of HT/LT Cable 03/04 Core on wall withall accessories & refilling of cable trench (as per IE rule)after laying of cable (Cable will be supplied by Rly free of cost at Consignee Depot)

600

33

19926

... More
Supply and Laying of Double WalledCorrugated (DWC)DWCPipe/duct withassociated collars etc. as perRDSOSpecification No.RDSO/SPN/204/2011or latest anti-rodent & anti-oxidant and nonflamepropagating type in 6 metersstraightlength and of size 120 mmouter dia,& 103.5mm inner 3 dia. (Themanufacturers, suppliersmust producevalid IS license and should becertifiedunder ISO 9000 and shall submitcopyof certificate). One coupler withsuitable rubberO-ring should besupplied with every 6m ofpipe length.(The total quantity of above itemsisequal to no. of pipes supplied.) DWC pipe DWC shall be marked at every 1mtr length in such away that manufacturer's name, vendor name and year of manufacture can be easilyidentified.

200

586

117340

... More
Supply, Erection,Testing & Commissioningof 5 star rated super energy saving efficient BLDCCeiling Fan, sweep size 1200mm., down rod length asper site requirement, power factor 1 greater than 0.98with Electronic Regulator & double ball bearing and MSFlat size 50 X 5mm clamp of suitable size with hanging hook, nut bolt washer etc & Connection shall be takenwith twin cord flexible PVC insulated copper wire size48/0.2 mm., 03 blades of Aluminium with power consumption not more than 28 Watt, Warranty 03 years, required make - RR, Havells, Crompton, Bajaj bee 5 star rated BLDC super energy efficient ceiling fan

24

2850

68400

... More
Supply, Erection, Testing &Commissioning of Exhaust Fan 380 mm sweep 1400 RPMfour blades with louvers suitable to work on 230 volt ACsupply connection shall be taken with twin cord flexible PVC insulated copper wire size 48/0.2mm. exhaust fan

20

2579

51588.4

... More
Supply, erection, Testing &Commissioning of constructed, Installation Testing andCommissioning of Maintenance Free Earth as per RDSOSpec.No.RDSO/SPN/197/2008 or latest consisting thefollowing , A) Copper bonded steel electrodes of 3.0meter long & 17.2mm.dia with Cu- bonding thickness ofmin.250 microns and UL listed and marked=1No. B)Earth enhancement material supplied in sealed bags ofin.10Kgs.=3Nos. C) Copper strip 150x25x6 mm. toterminate earth rod=1No. D) Copper strip 300x25x6mm. Main LT panel board to terminate earth rod =1No E)Copper strip 150x25x6 mm. Sub distribution board toterminate earth rod =1No F) Digging the earth to therequired depth G) Insertion of electrode H) Filling ofearth enhancing compound (30Kg.) -provision ofexothermic weld connection on copper tape of25mmx6mm.x150mm.to the earth electrodes all thematerials, tools and features required for the weld to bearranged by the contractor-1No. Note:- Earth pit shouldbe prepared as per RDSO. DRG. No.SDO/RDSO/L&B/001I) Provision of Exothermic weld connection in coppertape 25mm.x6mm.x150mm. to the earth electrodes . Allmaterial, tools and features requires for the weld to bearranged by the contractor J) Provision of Exothermicweld connecting ,One to connect 35 Sq.mmmultistranded single core PVC insulated copper cable tothe copper tape welded to the earth electrode andanother to the copper tape (Main LT panel board) to befixed inside the equipment / Escalator apparatusroom,weld materials, tools and features and all othermaterials requires for the weld to be arranged by thecontractor K) Electrode termination in a concrete sinkand routing the cadmium cable to bus bar in equipmentroom ( all other materials required for the work shall bebrone by the contractor Note:- Earth resistance shouldbe less than One Ohm. L) MDB & SDB are to be installedin equipments/Panel room and earth connections to equipments cables extended from LT panel board andSub distribution board as the case may be .

4

9550

38202.04



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.