North Central Railway Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

North Central Railway - NCR Tender

Works
Telecommunication Services
Electrical and Electronics
Electrical Works
Ireps
+2Sagar, Madhya PradeshAshoknagar, Madhya Pradesh
Opening Date12 Dec 2024
Closing Date6 Jan 2025
Tender Amount₹ 32,16,49,762.9 
Notes
Download

Costs

Summary

"balance Work Of Provision Of Electronics Interlocking At Jln, Dua & Agd Stations along With Indoor And Outdoor Work In Connection With Jro-jln-dua-mxs & Koa- agd-bina 3rd Line Work Along With Ibh In Jhs-bina Section Of Jhansi Division Of n.c.railway".

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

  • Tender Id

    JHS-SNT-C-TENDER-2024-01-DYCSTE-C-JHS-S AND T/NORTH CENTRAL RLY
  • Tender No

    JHS-SNT-C-TENDER-2024-01
  • Tender Authority

    North Central Railway View
  • Purchaser Address

    -
Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply of essential spares (For AGD station) as per RDSO recommendations for EI 4 system at above mentioned station. Item - wise details of spare to be supplied with unit rates shall be given by the tenderers. For tender evaluation total cost of all spares will be considered and individual rates will not be considered for evaluation. Inspection by RDSO.

1

4449249

4449249.86

... More
(a) Design, preparation and supply of the following Technical documents: (i) Installation, Testing, Commissioning and Maintenance manuals (ii) Functioning and System overview manuals (b) Design, preparation and supply of the following the following completion documents: (i) Application Logic circuits (ii) VDU/CCIP/LCP diagram (iii) Interface Circuit/Wiring diagrams consisting of Relay contact analysis chart, Relay disposition chart, Relay contact to contact wire list chart, LCP/VDU/CCIP cable termination chart, Power supply diagram, Electronic signalling equipment and Power supply layout diagram, Relay rack and Cable termination rack layout diagram, Relay rack and Cable termination rack particulars, Fuse, Resistors, Condensors etc. particulars, Details of Analog and digital inputs to be supplied to Data logger, Block wiring diagram (if applicable), Wiring diagrams for SSDAC 5 or HASSDAC or MSDAC or BPAC (if applicable) (iv) Cable Route plan with overlaid Location Boxes placement (As per NCR HQ Drg. No. TYP/14/0017 issued vide letter no. S&T/NCR/DRG/TYP dtd 29.12.2014) (v) Cable Core plan with overlaid Location box placement (vi) Location huts/Goomties wiring diagrams (if applicable) (vii) Location boxes wiring diagrams (viii) Track circuit bonding plan (ix) Earthing particulars plan (x) Signal Interlocking plan (SIP) (xi) Station working rule diagram (SWRD) (xii) Station working rule (SWR both hindi/english) (xiii) Selection table/ Route control chart. (xiv) Miniature diagram in red/green. All the above completion documents should be supplied as follows: (i) Two sets initially for approval and commencement of work (ii) One set in soft copy (in editable AUTOCAD format) in Pen drive. (iii) One set of Original tracings (iv) Six sets of final 'As Made' completion plans/diagrams in proper bounded form. (Unit of this item is per station) (Inspection by SSE/Drg/C/JHS.)

6

177255

1063535.76

... More
Supply of embedded fanless PC based Maintenance terminal/Datalogger terminal as 6 per RDSO spec. No. RDSO/SPN/192/2019 Ver. 2.0 or latest & RDSO TAN No. - STS/E/TAN/3007 version 1 dated:02.11.12 or latest. The size of VDU shall be 55 inch, LED 4K resolution. Note: One table of suitable size along with revolving chair should be supplied with Maintenance terminal (make Godrej/Methodex or similar of reputed make) (Inspection by Representative of Dy.CSTE/C/JHS.)

3

388599

1165798.41

... More
Design of circuits and plans to suit layout as per Signalling Interlocking Plan of IBS/ABS/LC GATE. This will include supply of Control cum Indication panel diagram, wiring diagrams, Relay rack/Relay arrangements, Bus bar details, Fuse analysis, contact analysis, Relay room tag block analysis, panel tag block analysis, Power panel diagram, IPS wiring diagram, Auto change over diagram, Power equipment arrangement with program switch, Block circuit wiring diagram, Digital Axle counter wiring diagram and all other relevant drawings. Submission of Two sets of prints with all correction for Railway's approval. Approved copy (06 Sets) of all drawings in plastic folders along with the original tracings in spiral bound with editable AutoCAD copy latest version. (Inspection by SSE(drg)/C/JHS.)

-

-

7

... More
Training of Railway Personnel on EI as per detailed training schedule issued by Engineer in charge. (Training to be ensured by Representative of Dy.CSTE/C/JHS.)

3

37946

113839.38

... More
Supply of Micro Processor based Data Logger System with 1024 digital inputs and 64 analog inputs with protocol converter as per RDSO Spec. No. IRS (S) 99/2006 (Amnd. 3) or latest. It includes supply of all the items required for complete indoor relay room wiring from data logger to 9 relay rack tag blocks, drawing/extension of power supply upto Data Logger. It includes relay room door lock checking arrangement, commercial power supply monitoring arrangement & monitoring of DG sets, ELD , IPS, UFSBI, BI, interlinking and networking of Data logger. Note: Total numbers of relays and other signalling functions/gears required to be wired as per list circulated vide RDSO Letter No.STS/E/Data logger dtd.12.09.2011 or latest guidelines. (Inspection by RDSO.)

6

603937

3623625.48

... More
Installation, Wiring, Testing & Commissioning of complete Electronic Interlocking system as per RDSOspecification No. RDSO/SPN/ 192/2019 ver. 2.0 or latest with Hot Standby arrangement for functioning of EI system, supplied vide Item No. 01001 of SOR, including 1 transportationof required materials from consignee's depot to site, erection and grouting of EI Relay Racks, fixing and wiring of all the interfacing relays (Vital & Non-Vital), installation and wiring of Microprocessor equipments, interface equipments, power supply equipments and all other associated accessories to make complete EI system to be functional, FAT and SAT, Technical Advisory Notes (TAN) issued by RDSO time to time on installation practices of EI are to be complied. (For a 6/10 line/road station)

3

629289

1887867.84

... More
Provision of Ring Earth for EI system, consisting of 06(six) number of maintenance free earths, which includes supply of all components of earthing & bonding system like earth electrode, earth enhancement materials, earth pit, equi-potential earth bus bar, connecting cables and tape/strips and other associated accessories in accordance with RDSO Spec. No.RDSO/SPN/197 Ver.1.0 or latest and provision of earth pits to be connected in a ring to achieve less than 01(One) ohm earth 2 resistance for connecting EI equipments, relay racks, panel , power equipments as per RDSO TAN no. STS/E/TAN/3006 dated 02.11.2012. Diagram of ring earth should be supplied to Railway for approval before execution. All related materials as recommended by RDSO in Spec . No.RDSO/SPN/197 Ver. 1.0 or latest, will be supplied by the contractor. Note: If due to site condition (high soil resistivity, larger size of EI room etc.) more than six maintenance free earths are required then the rate of payment for each such extra individual earth shall be done as per the rates of SOR items 13002 and 13003 (Earthing Items SOR). No other payment for any other material/accessory/fixture etc. shall be admissible for such extra maintenance free earths. (Inspection by RITES)

6

172246

1033478.46

... More
Installation, wiring, testing and commissioning of embedded fanless PC based Maintenance terminal/Datalogger terminal as per RDSO spec. No. RDSO/SPN/192/2019 Ver. 2.0 or latest & RDSO TAN No. - STS/E/TAN/3007 version 1 dated:02.11.12 supplied vide SOR item 01004.

3

97149

291449.61

... More
Installation, testing and commissioning of Micro Processor based Data Logger System with 1024 digital inputs and 64 analog inputs with protocol converter as per RDSO Spec. No. IRS (S) 99/2006 (Amnd. 3) or latest. It includes supply of all the items required for complete indoor relay room 5 wiring from data logger to relay rack tag blocks, drawing/extension of power supply upto Data Logger. It includes relay room door lock checking arrangement, commercial power supply monitoring arrangement & monitoring of DG sets, ELD , IPS, UFSBI, BI, interlinking and networking of Data logger. It also includes installaion of leased line MODEM and other interfacing cards, if required for networking of Data Logger. Note: Total numbers of relays and other signalling functions/gears required to be wired as per list circulated vide RDSO Letter No.STS/E/Data logger dtd.12.09.2011 or latest guidelines.

6

109866

659200.02

... More
Supply and installation of Cable Termination (CT) rack as per drawing of NC Railway, complete along with fitting arrangements, wall supports, scaffolding and suitable grouting 1 arrangements and also with arrangement for fixing four 8-way terminal strips/ Screw less terminals/ ARA terminals. The CT rack shall be covered with hylum sheet of minimum 10 mm thickness for fixing of 8-way terminal strips/ Screw less terminals/ ARA terminals. Supply of 8 way terminal strips/ Screw less terminals / ARA terminals not covered under this item. Cable termination rack shall be corrosive resistant, and powder coated. (Inspection by RITES)

13

48325

628231.63

... More
Supply of Disconnect Terminal block for four conductors with screwing cage/clamp 2 type, sliding switch disconnect, as per RDSO spec. RDSO/SPN/189/2004 Ver. 3.0 or latest, for each conductor size up to 2.5 sq. mm, equivalent of M6 terminals. Each terminal block equipped with two markers, on top and bottom, an end plate, two end clamps and adequate lenght of rails for fitting terminal blocks. (Inspection by RITES/RDSO)

22000

192

4241820

... More
Q-Series Line Relay (QNA1 Type),AC immunized, 8F/8B, 24 V DC along with plug board 3 (base plate), connectors, retaining clips etc and conforming to BRS-931A and RDSO Specn.No.IRS: S - 34, S - 23, S - 60 or latest, as applicable. The interlocking code for this unit shall be "ABDGH". (Inspection by RDSO)

335

4456

1493044.75

... More
Q-Series Line Relay (QNA1 Type), AC immunized, 12F/4B, 24 V DC along with plug 4 board (base plate), connectors, retaining clips etc and conforming to BRS-931A and RDSO Specn.No.IRS:S - 34, S - 23, S - 60 or latest, as applicable. The interlocking code for this unit shall be "ABDFH". (Inspection by RDSO)

40

3926

157071.2

... More
Q-Series LED ECR (Universal Type i.e.QECX-61), 4F/4B complete with plug board(base 5 plate), connectors, retaining clips etc and conforming to BRS:941A STS/E/RELAYS/AC LIT LED SIGNAL/09-2002, Amdt.-1 or latest and RDSO Spec.No.IRS:S - 34, S-23 or latest, as applicable. The interlocking code for this unit shall be "ABDHK". (Inspection by RDSO)

30

6816

204494.7

... More
Q-Series Neutral Line Relay (QSPA1 Type), AC immunised, 24V DC,8F/4B along with 6 plug board (base plate), connectors, retaining clips etc and conforming to BRS-933A and RDSO Specn.No.IRS: S - 34, S - 23, S 60 or latest, as applicable. The interlocking code for this unit shall be "ABDEJ". (Inspection by RDSO)

30

6059

181774.8

... More
Supply of Key Lock Checking Relay (KLCR) working on 24V DC, AC Immunized, metal to 7 metal, with different ward combinations and contact configuration 4F/4B with 2 extra ward plates, RDSO spec no. RDSO/SPN/219/2016 Ver 1.0 with Amendment-1 or latest. (Inspection by Representative of Dy.CSTE/C/JHS)

65

8026

521744.6

... More
Q-Series Track Relay (QTA2 Type), AC immunized, 9 Ohms, 2F/1B along with plug board 8 (base plate), connectors, retaining clips etc and conforming to BRS:939A & 966(Appendix F2) or latest and RDSO Specn.No.IRS:S - 34, S - 23, S-60 or latest, as applicable. The interlocking code for this unit shall be "FGHKX". (Inspection by RDSO)

250

3804

951245

... More
Supply of Relay A.C. Immune plug in type style (QBAT D.C. baised track relay, 9 Ohms, 9 D.C. 2F/2B Contacts front and back contact metal to carbon, complete with plug board , retaining clips and connectors, confirming to RDSO/SON/84 ver 2.0 or latest and RDSO Spec.No. IRS: S - 34, S-23 or latest, as applicable . The interlocking code for this unit shall be "ABEJX". (Inspection by RDSO)

25

6136

153400

... More
Contactor Unit (QBCA1 Type), 24 V DC, 2HF/4B complete with plug board(base plate), connectors, retaining clips etc and conforming to BRS- 943 and RDSO Specn.No.IRS: S - 34, S-23 , S-60 or latest, as applicable. The interlocking code for this unit shall be "BCEJK". (Inspection by RDSO)

40

6825

273018.8

... More
Q-Series Magnetically Latched Neutral Line Relay (QL1 Type), 11F/4B,24V DC complete 11 with plug board(base plate), connectors and retaining clips and conforming to BRS-935A and RDSO Specn.No.IRS: S - 34, S-23 or latest, as applicable. The interlocking code for this unit shall be "ABDEG". (Inspection by RDSO)

55

5985

329200.3

... More
Q-Series Twin Neutral Line Relay(QNNA1 Type), AC immunised, 4F/4B, 24V DC 12 complete with plug board(base plate), connectors and retaining clips etc and conforming to BRS-960 and RDSO Specn.No.IRS: S - 34, S-23, S-60 or latest, as applicable. The interlocking code for this unit shall be "ACDHJ". (Inspection by RDSO)

40

5582

223298.8

... More
Supply of Relay Time Element Clock type / Fail safe Electronic Timer conforming to IRS: S61 / 2000 with Amend. 2 or latest / or equivalent with base, for time delay of 30 / 60 / 120 / 180 / 240 seconds (as specified) and to work on 110V AC or 60 V DC.or 24V DC (INSPECTION AGENCY:-RDSO)

28

7609

213052.27

... More
Q-Series Neutral Line Relay, non-AC immunised, (QN1 Type), 8F/8B, 24V DC complete 14 with plug board(base plate), connectors and retaining clips etc and conforming to BRS- 930 and RDSO Specn.No.IRS: S - 34 ,S-23, S-60 or latest, as applicable. The interlocking code for this unit shall be "ABCDF". (Inspection by RDSO)

80

4066

325333.6

... More
Supply of 1 x 6 Sq mm (Red/Black/Green) multi strand copper power wire , 85 15 conductor each dia 0.30 +/- 0.01 with insulation thickness of 0.8 mm and nominal conductor resistance of 3.3 ohms/km and test parameters as per RDSO Specn.No.IRS:S-76/89 (Amnd.3) or latest. Colour of the wire will be specified by the Engineer incharge. (Inspection by RITES/RDSO)

1000

47

47970

... More
Supply of 1 x 10 Sqmm (Red/Black/Green) multi strand copper power wire, 101 16 conductor each dia 0.45 +/- 0.01 with insulation thickness of 1.2 mm and nominal conductor resistance of 1.127 ohms/km and test parameters as per RDSO Specn.No.IRS:S-76/89(Amnd.3) or latest. Colour of the wire which is required will be specified by the Engineer incharge. (Inspection by RITES/RDSO)

2000

125

251160

... More
Supply of 1 x 16 Sqmm (Red/Black/Green) multi strand copper power wire as per IS: 17 2465/1984 and IS:694:2010 or latest, 101 conductor each dia 0.45 +/- 0.01 with insulation thickness of 1.2 mm and nominal conductor resistance of 1.127 ohms/km and test parameters as per RDSO Specn.No.IRS:S-76/89(Amnd.3) or latest. Colour of the wire which is required will be specified by the Engineer incharge. (Inspection by RITES/RDSO)

800

147

118216

... More
Supply of 1 x 25 Sqmm (Red/Black/Green) multi strand copper power wire, Colour of the wire which is required will be specified by the Engineer incharge. (Inspection by RITES/RDSO)

600

398

238902

... More
Supply of Fuse auto changeover system for Railway Signaling System as per RDSO/SPN/209/2012 Rev.2 or latest for Relay room fuses up to 10 Ampere capacity for 19 12V/24V/60V/110V DC and 110V AC systems. The units shall be mounted on DIN rail in adequate size enclosure as per instructions of Railway site engineer. Two no. of NO+NC contacts shall be provided for remote monitoring. The changeover time shall be less than 1 msec. The audio visual alarm for main and standby fuses shall be provided. One set means set of each fuse. (Inspection by RDSO)

1692

2248

3803903.64

... More
Supply of earth leakage detector as per RDSO Specification No. RDSO/SPN/256/2002 with latest amendment, 8 channel for monitoring 4 AC channels (110V- 4no. supplies) & 4 DC channels (110V DC-1no supply, 24V DC-3no. supplies) (Inspection by RDSO)

13

116124

1509623.88

... More
Supply & installation of PPTC Fuses Fuzetec make PTC Resettable Fuse various types as per requirement & instruction of site incharge. (Inspection by Representative of Dy.CSTE/C/JHS)

3

15656

46970.37

... More
Fabrication and supply of point rodding (Ground Connection) set for electric point machine (RDSO Type) 220 mm stroke clamp type for thick web switches to suit RDSO Drg. No.RDSO/S/11000 & RDSO/S-3395 complete with insulation. (Inspection by RITES/RDSO)

50

28453

1422656.67

... More
Fabrication, supply, instalaltion and fixing of SWRD/cabin diagram on good quality waterproof board of size 1500 mm(min) x 700 mm(min), thickness of board shall be 12 mm (min). The work shall be done as per instructions of Railway site incharge. (Inspection by Representative of Dy.CSTE/C/JHS)

-

-

23

... More
Supply, installation of glass fronted key box for crank handle etc as per instructions of site incharge. (Inspection by Representative of Dy.CSTE/C/JHS)

17

2510

42685.96

... More
Supply & erection of SM TABLE (wood shall be of good quality) for DUAL VDU of suitable size as per approved drawings communicated by site engineer as per Station requirements. (Inspection by Representative of Dy.CSTE/C/JHS)

3

131072

393216

... More
Supply and installation of earth electrode as per standard practice and as per NCR Drawing no. S&T/CONST/6.4/97. It includes supply of GI pipe of 3m length. It includes connecting the earth electrode to the equipments which are required to be earthed including digging of earth pit 3 mtr 26 deep and fixing earth electrode pipe, casting of cement concrete enclosure with cover (cover as per drawing no. S&T/CONST/6.3/97. It includes installation of 7 strand GI wires as earth lead wires, supported on MS flat size 5mm x 40 mm, soldering and nut bolt both, one end of both earth lead wire and MS flat to earth electrode and other end to Location boxes, block equipments, power equipments, cable sheath, signals etc. as per site requirement and as per instructions given by engineer incharge. (Inspection by RITES)

240

3450

828230.4

... More
Supply of basic material to construct unit maintenance free earth as per RDSO Specs. No RDSO/SPN/197 Ver. 1.0 or latest to achieve a resistance less than 1 ohm. It consist of following: (a) Copper bonded steel electrode of minimum 3.0 m long, minimum 17.0 mm dia with copper bonding thickness of minimum 250 microns and UL listed and marked = 1 no. (b) Earth enhancement material supplied in sealed bags of minimum 10 kg = 3 nos. (c) Copper strip of 150x25x6 mm, to terminate 27 earth rod = 1 no. (d) Copper strip of 300x25x6 mm (MEEB) = 1 no. (e) Copper strip of 150x25x6mm (SEEB) = 1 no. (ii) Supply of 35 sq. mm multi strand single core PVC insulated copper cable as per IS: 694 for connecting main earth electrode to MEEB in the equipment room in duplicate.(minimum 10 meter) (iii) Supply of 16 sq. mm multi strand single core PVC insulated copper cable as per IS: 694 for connecting MEEB to SEEB and SPD to MEEB (minimum 10 meter ) (iv) Supply of 10 sq. mm multi strand single core PVC insulated copper cable as per IS: 694 for connecting various equipments to SEEB (v) Supply of copper lug sleeve for 3/16 cable (Inspection by RITES)

136

17575

2390293.84

... More
Supply of Colour Light Signal Post, Tubular Mild steel, 4.5 m length, 140 mm Dia, as per 28 RDSO spec. No. IRS: S-6/81 or latest and Supply of cast iron Main signal surface base (As per RDSO Drg. No. 2011/M or latest), with CLS ladder assembly suitable for colour light signal 4.5 m long, as per RDSO drg. No. SA 23153 and signal front staging complete assembly and complete signal back staging for CLS unit. (Inspection by RITES)

40

25285

1011408

... More
Shunt signal position light post as per IRS 56/81, complete with bracket, Post as per IRS-S-6 of 1981 having 4.5mm thickness & minimum 1m length, surface base, etc. (Inspection by RITES)

21

2564

53848.81

... More
Supply of Offset brackets for Main Signal, made of Mild Steel, outer diameter 140 mm (5.5 inch), thickness of pipe 4.5 mm with fixing arrangement on Main Signal post as per Drawing No SA-23080/Adv.along with fixing U bolts, nut and clamps. (Inspection by RITES)

58

1207

70014.12

... More
Supply of Offset brackets for Shunt Signal, made of Mild steel, outer diameter 89 mm (3.5 inch), thickness of pipe 4.5 mm with fixing arrangement on Shunt Signal post as per Drawing No SA-23080/Adv. along with fixing U bolts, nuts and clamps. (Inspection by RITES)

16

1898

30379.84

... More
Supply, fabrication and fixing of retro-reflective marker/boards/plates as per the 32 following: 'P'marker-Non illuminated as per Drg. no.SA-23456 (Adv), 'AG' marker-Non illuminated as per Drg. no.SA-23459-60 (Adv), 'A' marker - Illuminated as per Drg. no.SA-23461(Adv), 'G' marker -Non illuminated as per Drg. no.SA-23477(Adv) or as applicable and provided by Railways. (Inspection by Representative of Dy.CSTE/C/JHS)

30

887

26633.1

... More
Supply of Non Metallic (FRP) colour light signal housing multi unit type for railway 33 signaling suitable for RE area TWO Aspects, complete without lenses, lamps and signal transformer as per RDSO Drg. No. SA 23003 A/M (Adv.) and as per RDSO spec. No. RDSO/SPN/194/2006 (Rev 2.0) or latest and FRP material as per RDSO SPEC. No. RDSO/SPN/151/1997 or latest. (Inspection by RITES)

40

31322

1252894

... More
Supply of Non Metallic (FRP) colour light signal housing multi unit type for railway signaling suitable for RE area THREE Aspects, complete without lenses, lamps and signal transformer as per RDSO DRG. No. SA 23002 A/M (Adv.) and as per RDSO spec. No. RDSO/SPN/194/2006 (Rev 2.0) or latest and FRP material as per RDSO SPEC. No. RDSO/SPN/151/1997 or latest. (Inspection by RITES)

25

35753

893841.25

... More
Supply of Non Metallic (FRP) colour light signal housing multi unit type for railway 35 signalling suitable for RE area FOUR Aspects, complete without lenses, lamps and signal transformer as per RDSO Drg. No. SA 23001 A/M (Adv.) and as per RDSO spec. No. RDSO/SPN/194/2006 (Rev 2.0) or latest and FRP material as per RDSO SPEC. No. RDSO/SPN/151/1997 or latest. (Inspection by RITES)

8

42250

338000.56

... More
Supply of Position Light Shunt Signal Unit Complete, Non-Metallic, made of FRP as per Drg. No. SA-23840 (Adv.) suitable for LED Signal Lighting Unit.(Supply of LED Unit is not covered in this item) (Inspection by RITES)

30

14796

443907.6

... More
Supply of Calling ON Signal Unit, non metallic, with Brackets, clamps and fixing 37 accessories, suitable to LED signal lighting unit and as per RDSO spec. RDSO/SPN/194/2006 (Rev. 2.0) or latest. The FRP material shall conform to RDSO/SPN/151/1997 or latest. Calling On Signal Unit shall conform to RDSO Drg no SA-24351(Adv) Alt1 or latest without lamp, lamp holder and lens. (Inspection by RITES)

14

11667

163343.18

... More
Supply of Junction route indicator unit 1 way, made of FRP, (Without Lenses & Holder) 38 as per Drg. No. SA 23401 -06 (Adv.) (as applicable) suitable for LED Signal Lighting Unit and as per RDSO spec. IRS: S-66/84 Amd.-1 or latest and RDSO/SPN/194/2006 Rev.2 or latest, (Supply of LED Unit is not covered in this item) (Inspection by RITES)

32

44476

1423240.32

... More
Supply of Junction route indicator unit 2 way, made of FRP, (Without Lenses & Holder) 39 as per Drg. No. SA 23401-06 (Adv.) (as applicable) suitable for LED Signal Lighting Unit and as per RDSO spec. IRS: S-66/84 Amd.-1 or latest and RDSO/SPN/194/2006 Rev.2 or latest.(Supply of LED Unit is not covered in this item) (Inspection by RITES)

18

54127

974290.5

... More
Supply of Multi Lamp Route Indicator (LED double digit) for 1 to 19 (double digit) with 40 white LED along with housing as per specification IRS: S 66/84 Amd. 1 or latest and drawing no. SA 23761 (Adv.) or latest. Lamp proving compatible with normal bulb type multi lamp route indicators. Retrofits the existing conventional multi lamp type route indicators housing . Input operating voltage 110V AC +25%. Uniform intensity over entire operating range. (Inspection by RITES)

8

56163

449307.52

... More
Supply, fabrication and fixing of the Calling On board/BSLB board as per RDSO Drg. no. 41 SA 2373 (Adv)/Stop/Warning board as per drg. no SA-2380 (Adv), or as applicable, on concrete foundation and painting with Retro reflective paint. All work to be carried out as per Railway site engineer instructions. (Inspection by Representative of Dy.CSTE/C/JHS)

24

8112

194699.52

... More
Supply, fabrication and fixing of Retro-reflective Signal number plates as per NCR drg. 42 No. TYP/14/0014 dtd 28.11.2014 issued vide NCR letter no. S&T/NCR/DRG/TYP dated 28.11.2014,on signal post with contractor's own material like clamp, U bolts, nuts etc. (Inspection by Representative of Dy.CSTE/C/JHS)

146

744

108746.64

... More
Supply and fixing of protective screen of expanded metal 12 SWG of size 1200 x 1500 mm on signals as per std. practice in RE Area and earthing the screen with MS flat of 2"x 1/4"using GI nut bolts and washer. (Inspection by Representative of Dy.CSTE/C/JHS)

15

3513

52702.8

... More
Supply of Apparatus Case with miniature "E" type locks as per Spec No IRS: S: 30/64 & RDSO Drg. No. SA 3376 (For E Type lock With 1 key and 1 handle per 5 apparatus case). Single case as per Drg No WS-8842/A with latest amendment. Inspection by RITES.

220

22968

5053136.03

... More
Supply of Apparatus Case with miniature "E" type locks as per Spec No IRS: S: 30/64 & RDSO Drg. No. SA 3376 (For E Type lock With 1 key and 1 handle per 5 apparatus case). Half case as per Drg No WS-8842/A with latest ammendment. Inspection by RITES.

168

17690

2971956.61

... More
Supply of Cartridge Fuse block, made of PBT, as per RDSO spec. No. IRS: S-75/2006 (Rev.2) or latest and as per Drawing. No. SA- 23748 (Alt.-4) or latest. (Inspection by RDSO)

980

243

238786.8

... More
Supply of Non deteriorating type, Round head type, low voltage cartridge fuse as per Spec No IRS: S -78/92 with latest amendments, 2A/4A/6A/8A/10A rating capacity. (Inspection by RDSO)

980

123

120736

... More
Supply of Phenolic laminated Sheet, resin bonded, grade P3 in standard size of 1220 X 1220 x 10 mm as per spec. No IS 2036 of 1995 or latest. Test report of manufacture to be supplied. (Inspection by RITES)

266

5756

1531133.24

... More
Track Lead Junction Box (TLJB) 2 way in box size 120x220x90 mm, 6 mm thick made from FRP (SMC) Glass Fiber Reinforced Polyester as per RDSO specification No. RDSO/SPN/151/1997, Hot compression moulded IP 66 protection class, with tongue & groove sealing system having 49 chloroprene seal, cover and base system fastened by captive lid stainless steel screws, flammability characteristics compliant to UL94 VO, grey colour, minimum 25 % glass content, fitted with PBT/Wago terminals of required size for cable/track lead connections, including cable entry and exit systems at the bottom for required cable /track lead connection size with polyamide gland and 2 nos. FRP angles white colour with nuts and bolts, size 40x40x6 mm having fire retardant characteristics as per UL94 V1, for fixing TLJB and all required accessories. (Inspection by RITES)

100

5393

539329.67

... More
Supply of Track Lead Junction Box(TLJB), 4 way, 250 mm x 255 mm x120 mm made from FRP, as per Drg.No. 20101/M(IRS) or latest, including brass bolts and hylam board sheet with terminals etc. The FRP material shall be as per RDSO spec. RDSO/SPN/151/1997 or latest. The technical specifications are as follows: (a) TLJB complete with cover to be in black/red/grey with all the 50 holes required for mounting on FRP stump (vertical two for each FRP angle) HDPE pipe , cable etc. (b) Each TLJB shall have two bakellite terminal block fitted horizontally, each bakellite terminal block shall have two nickel chrome plate with brass terminal. Along with each TLJB , nickel chrome plated brass links(two nos.of adequate strength for vertical linking of the terminals to be supplied. (c) HDPE pipe along with two nuts for fixing on the TLJB hole . (d) The FRP stump for mounting the TLJB (Inspection by RITES)

429

5339

2290782.78

... More
Supply of uncharged Low Maintenance Lead Acid (LMLA) secondary cell, 2V, 80 AH, in dry condition, shelf mounting type, conforming to RDSO Specn.No.IRS:S-88/2004 or latest, with inter cell connectors, nuts and bolts, washers, microporous vent plug, float etc. (Inspection by RDSO)

498

3111

1549651.5

... More
Supply of B Type Choke as per RDSO Specn.No.IRS:S-65/83 (Amnd. 3) or latest. (Inspection by RDSO)

332

5911

1962724.24

... More
Supply of Adjustable Track Feed Resistance 30 Ohms (Disc Type), Phenolic moulded base, as per RDSO Drg. No.SA-20161-66/M or latest. (Inspection by RDSO)

166

2280

378616.12

... More
Supply of Track feed Battery Charger as per RDSO Specn. No.IRS: S-89/2013 Ver.1.0 or latest. Charging capacity rating should be suitable for charging 80 AH Battery. (Inspection by RDSO)

166

5903

979939.5

... More
Supply of Hydrometer, Exide make or similar for measuring specific gravity of Battery Graded acid with mounting stand in location Boxes. (Inspection by Representative of Dy.CSTE/C/JHS)

44

355

15652.56

... More
Supply of PVC insulated, jacketed wire rope for Track lead connections. The wire rope should be of galvanised steel, 6 mm dia, (6x19 stranded wire with steel core of 6 mm) sheathed with PVC. (Inspection by Representative of Dy.CSTE/C/JHS)

1100

44

48488

... More
Supply of led indication system with indication, buzzer & acknowledgment button up to 57 6 line station with interface facility to existing data logger and modification of data logger embedded software when a station master fails to set the point against the occupied line within stipulated time after arrival of the train. (Inspection by Representative of Dy.CSTE/C/JHS)

1

55000

55000

... More
Supply of led indication system with indication, buzzer & acknowledgment button up to 58 10 line station with interface facility to existing data logger and modification of data logger embedded software when a station master fails to set the point against the occupied line within stipulated time after arrival of the train. (Inspection by Representative of Dy.CSTE/C/JHS)

1

85000

85000

... More
Supply of Electric Point Machine 143 mm stroke, AC Immunity 160V AC, complete with lock detector and slides for lock detector,Non-trailable,to operate on 110V DC, rotary locking with crank handle universal type as per RDSO Spec. No. IRS:S-24/2002 (Amnd. 1) or latest, RDSO DRG. NO S-10800 (ALT.5) WITH JUNCTION BOX TELESCOPIC. THE MOTOR WILL BE AS PER RDSO SPECN. NO. IRS: S-37/82 (AMND. 3) WITH RDSO DRG. NO. S-10910. This includes supply of Set of tools as per para 20.1 & 20.2 of RDSO SPECN. NO. IRS:S-24/2002 (AMND 1) The following set of tools in a suitable tool box shall be supplied along with every set of eight point machines or less. i). Hand operated square drive socket wrenches of 12.5 mm driving square (short type) as per IS: 7381 for M8, M10, M12 & M18 threads. (One 250 mm long 12.5 mm square extension bar as per IS: 7991 alongwith compatible Tee handle Square drive as per IS: 7975 suitable for above socket wrenches shall also be provided.) ii). Open jaw wrenches (spanners) for M10, M12, M20, M24 & M33 threads as per IS: 2028. iii). Adjustable wrench. iv). Screw driver 300 mm long. 20.2 Junction box and two numbers of telescopic pipes of approved type shall be supplied as an integral part of the point machine. (Inspection by RDSO)

59

100448

5926446.75

... More
Fabrication and supply of point rodding (Ground Connection) set for electric point machine (RDSO Type) as per RDSO Drg. No.SA-8800-01, 20-21, 9151-52,9000-01,03-04,9065-66,9101, as applicable. (Inspection by RITES/RDSO)

59

14771

871493.72

... More
Supply of Electric point machine, Non trailable, internal locking, 220 mm throw, with 61 IP67 motor ,Minimum AC immunity 440 VAC, with tools & complete accessories including complete ground connection and all insulation, crank handle and along with clamp point lock 60 kg, TWS as per Drg No. RDSO/S- 11000 as per RDSO SPN. IRS:S 24/2002 with Amd. 01 or latest. (Inspection by RDSO)

30

144314

4329420

... More
110V DC Motor for Electric Point Machine (IRS Type) with Gear Box with 400V AC Immunity with IP 67 Protection (IP 67 Compliant) as per Specification No: IRS:S 37-2022 Ver.2.0 or Latest, (Inspection by RDSO)

14

32450

454300

... More
Supply of Insulation materials for points i.e. gauge tie plate, William Stretcher Bar & P,D,L bracket as required at site (Inspection by Representative of Dy.CSTE/C/JHS)

210

1211

254361.3

... More
Supply of Double Walled Corrugated pipe made up of Polyethylene for underground 64 communication / signal cable protection 120 mm Outer Dia, 103.5 mm Inner Dia in 6 Meter straight length as per specn. Specn No IS-14390 (Part-2:2001) along with one coupler per every 6 meters. NOTE: One coupler for jointing shall be supplied with each 6 mtrs. length. (Inspection by RITES)

5000

656

3282950

... More
Supply of Medium class GI pipes 100 mm dia (4.5 mm thickness) with thread collars as 65 per IS 1239 (Part 1) 2004 or latest with coupling on culverts/bridges, perforated at a distance of 20 cm or less with 10 mm dia hole, or at any other locations as decided by Site Engineer. It includes supply of all material required for fixing arrangement. Contractor will also supply flexible/corrugated HDPE pipe at the end of GI pipe to protect the cables from sharp edges and sudden bends. (Inspection by RITES)

1000

991

991760

... More
Supply and fixing of RCC cable route marker, made with concrete in the ratio 1:3:6, engraved "NCR" "S&T" on top portion and painted on both sides, along the route at every 50 meter 66 and at route diversion. The cable marker is to be fabricated as per RDSO drawing no. SDO/cable laying/020, issued vide RDSO document no. RDSO/SI/G/2010 Version 1.1 dated 04.02.2014, or latest. The fixing work is to be done as per extant practice of NC Railway and as per Railway site supervisor incharge. (Inspection by Representative of Dy.CSTE/C/JHS)

400

429

171624

... More
Supply of thermo shrink jointing kit as per RDSO Specn.No. IRS: TC 77-2012 (Rev.3.0) with (Amdt.-1 to 3) or latest, suitable for 6 Quad/jelly filled cables for straight through/derivation joints. It includes supply of all the accessories, without transformer (Inspection by RDSO)

50

3361

168096

... More
Supply of Thermo Shrinkable straight through joint suitable for making straight 68 through/deviation joint for underground jelly filled cable, with all accessories as per RDSO Specn. No. IRS:TC57-2015(Rev-1.0) with Amdt-1 or latest amendment with all accessories for 10 pair/20 pair PIJFcables, 0.63 mm dia conductor. Inspection by RDSO

50

3128

156432.6

... More
Supplying and placing of one layer of quality bricks of standard size and of 'B' grade of the local make and spreading on cables laid.(minimum size of brick 200mm X 100mm X 70mm) (Inspection by Representative of Dy.CSTE/C/JHS)

48000

4

207360

... More
Supply of Digital AC/DC Leakage Clamp on meter, make/model ST-CL360, DCM 39A/Motwane or similar. (Inspection by Representative of Dy.CSTE/C/JHS)

1

58267

58267.8

... More
Supply of Digital Clamp Earth tester/meter, with memory storage facility, make Motwane/Meco/Fluke or better. (Inspection by Representative of Dy.CSTE/C/JHS)

-

-

71

... More
Supply of Handheld Digital Insulation Tester with separate ranges of 50 V, 100 V, 250 V, 500 V, 1000V with additional feature of multi metering of voltage continuity and low resistance model No.I 12 MOTWANE make or similar. (Inspection by Representative of Dy.CSTE/C/JHS)

1

17642

17642.29

... More
Supply of Steel stool, 1 ft by 1 ft size, 1.5 ft height, laminated top. (Inspection by Representative of Dy.CSTE/C/JHS)

12

1267

15207.12

... More
Supply of Office Almirah of size 900W x 1168.5H X 450D mm as per model no.KD minor with metal top of Godrej make or similar. (Inspection by Representative of Dy.CSTE/C/JHS)

3

17599

52798.66

... More
Supply of Office table, laminated top, size minimum 3 ft x 4 ft, make Godrej/Durian/Methodex/President or of similar reputed make. (Inspection by Representative of Dy.CSTE/C/JHS)

6

12583

75503.46

... More
Supply of Chair model PCH-7001 of Godrej make or of similar reputed make. (Inspection by Representative of Dy.CSTE/C/JHS)

9

11174

100570.95

... More
Supply of Chair, superior quality, size 57D x 58W x 88H and seat height 45 mm, make CH-7(Godrej) or of similar reputed make. (Inspection by Representative of Dy.CSTE/C/JHS)

9

2993

26945.28

... More
Supply and installation of of Gallant make Modular Power Supply Arrangement for VDU (42" - 85") and Industrial PC (Embedded PC) with Input and Output Redundancy Arrangement and Hot Pluggable Modules including necessary wire & accessories. Consisting of: 1. Input O-Ring Diode Module with Potential Free-1 No contacts (PFC) for two 110VDC Sources from IPS and Single 110VDC bus. 2. 78 Isolated Inverters (Master/Slave) -2 Nos. Input: 110VDC, Output: 120VAC/220VAC 500VA 3. Isolated DC-DC Converters-2 Nos. Input:110VDC, Output:24VDC/10A. 4.3U SS Rack with back Panel Mother Board/ Front Panel Power Connectors Inverter Auto Change Over Switch and all required over Switch and all required protection circuits. SS Rack Dimension:- 1.3U Height for main Rack (132. Smm ± 10%) 2.1U height for Mounting (44.4mm ±10%) Supply of Gallant make Modular Power Supply Arrangement for VDU (42" - 85") and Industrial PC (Embedded PC) with Input and Output Redundancy Arrangement and Hot Pluggable Modules.(Inspection by RITES)

11

195000

2145000

... More
Supply, Installation and commissioning of active lightning arrestor of Class 'A' for building protection as per statndard NFC-17-102 :2011 or latest. It shall work on early streamer 79 emission principle. It shall be made of stainless steel with an opearting time of 60 microsecond or less. A non-resettable counter shall be provided to count the number of lightning occurences. The device shall be installed on top of the building on a GI mast and shall be connected to the earth pit through a copper tape of 25mm x 2mm or better. The copper tape shall not touch the building throughout and shall be connected to the earth electrode by exothermic welding. (Inspection by RITES)

8

111652

893217.92

... More
Supply, installation, testing & Commissioning of Automatic Changeover device for DAC/MSDAC V.21/V.23to optical fibre STM (E1), Standard 19" Rack Mountable device consisting of two E1 port supporting 120 Ohms interface dual optical ports with (1+1) hot stand by (Dual core path and single core path) 20 Kms driving distance and four V.21/V.23 (E&M) Interface (04 ports) (04 E&M + 04 Quad) 2W/4W Interfaces with auto Change over Mechanism to Quad Ports 2W/4W each port 80 configurableas 2W or 4W No restriction in configuration unit to support potential free contacts four numbers can be linked with data logger/RTUfor E1 status, Quad status & power supply status, unit support front panel ressetable audiable buzzer in case of main link fails (opticalor E1): unit to support power off fail safe mechanism when the unit switched off the inputs is byepassed to the Quad cable automatically unit supports front panel indicators for Quad health status: E1Dual, optical dual path, dual DC power supply 18V DC to 72 VDC range make: team Engg/Cygnus/Latana/Waves /Fabio1CX-4P or Similar reputed make.(Technical specification as per annexure B attached.) (Inspection by RITES)

3

155665

466996.8

... More
Supply of CO2 type fire extinguisher capacity 4.5 Kg capacity ISI marked, with all 81 accessories, operating temperature (-30) ° to (50) ° for class 13 B type of fire with 1 mtr. long hose pipe fitted with PVC bend horn, with carying handle and wall mounting brcket, complete in all respect. It should conform to IS 2878:2004. Extinguisher certificate has to be supplied along with the item. (Inspection by Representative of Dy.CSTE/C/JHS)

62

5179

321148.22

... More
Supply, installation, Testing and Commissioning of Microprocessor based networkable analog addressable and modular type of fire alarm control panel with display with 2 loop expandable upto 4 loop, power supply and battery back up as per RDSO Specification no. RDSO/SPN/217/2021 ver 3.0 or latest, including GSM module-01 No' for sending SMS to configured mobile number and relay module-02 No's for connecting to Datalogger for remote monitoring. This panel should support sufficient devices of both Detectors and module in a single line circuit. (Inspection by RDSO)

5

100285

501428.65

... More
Supply, installation, testing and commissioning of addressable heat & smoke multi sensor, as per RDSO Specification No. RDSO/SPN/217/2021 Ver 3.0 or latest (Inspection by RDSO)

50

3133

156674.5

... More
Supply, installation, testing and commissioning of analog addressable & Resettable Manual call point with inbuilt short circuit fault isolator. (as per RDSO Specification No. RDSO/SPN/217/2021 Ver 3.0 or latest)

6

4303

25822.32

... More
Supply, installation, testing and commissioning of aspiration system with single pipe slot along with required module and power supply, interfacing module etc. (as per RDSO Specification No. RDSO/SPN/217/2021 Ver 3.0 or latest) (Inspection by RDSO)

2

290878

581756.32

... More
CPVC pipe and all other associated fittings, (as per RDSO Specification No. RDSO/SPN/217/2021 Ver 3.0 or latest) (Inspection by RDSO)

220

1180

259626.4

... More
Supply, installation, testing and commissioning of Hooter cum strobe including its control module. (as per RDSO Specification No. RDSO/SPN/217/2021 Ver 3.0 or latest) (Inspection by RDSO)

6

7748

46490.04

... More
Supply, installation, testing and commissioning of Fire survival cable 2C*1.5 sqmm (unarmored), (as per RDSO Specification No. RDSO/SPN/217/2021 Ver 3.0 or latest) (Inspection by RDSO)

1100

113

124729

... More
Supply, installation, testing and commissioning of analog LHS cable (as per RDSO Specification No. RDSO/SPN/217/2021 Ver 3.0 or latest) (Inspection by RDSO)

620

1084

672297

... More
Supply, installation, testing and commissioning of LHS interface module for LHS cable connectivity to control panle (as per RDSO Specification No. RDSO/SPN/217/2021 Ver 3.0 or latest) (Inspection by RDSO)

3

82951

248853.03

... More
Supply of module/cards/sub-systems of Automatic Fire detection and Alarms System. a. Loop Card.

2

23364

46728

... More
Supply of RS485/RS232/RS422 serial to fiber media converter single mode dual fiber SC type and distance upto 20KM.(Inspection by Representative of Dy.CSTE/C/JHS)

4

47500

190000

... More
Supply and fixing of PVC pipe of 25 mm size of IS standards on wall/floor etc. All necessary items like screws/nails required to be supplied by contractor. (Inspection by Representative of Dy.CSTE/C/Jhs)

1600

34

55952.01

... More
Laying / drawing of various type of cables on PVC pipe /capping casing, or cable trays, 94 ladder, shelter etc as instructed by Railway engineer at site. (Indoor cables to be drawn through pipe, outddor cables if required to be clamped on wall/Floor etc) (Inspection by Representative of Dy.CSTE/C/Jhs)

1600

4

7199.99

... More
Supply of Relay Rack Assembly powder coated complete with scaffolding, fixtures and 95 accessories including MS Bars for fixing of relay, plug board, string rods, fuse strips with bracket, 11 Way Bus Bars with cover and mounting brackets, runway for cable/wires, frame, base assembly etc. Siemens type & as per extant practice on the division. Typical part list as per Annexure and Rack arrangement as per standard Drg.& sketch SK-727/A of N.C.Rly. (Inspection by Rites)

3

42076

126230.41

... More
Supply of PVC indoor cable 1x40x0.6mm dia colour coding of insulation of inner core shall be in eight colours viz Blue, Red, Grey, Green, Brown, Block, Yellow & White as per specn IRS S 76/89 (Amd.-3) or with latest . (Inspection by RDSO)

2

145706

291412.87

... More
Supply of PVC indoor cable 1x60x0.6mm dia colour coding of insulation of inner core shall be in six colours viz Blue, Red,Green, Grey, Brown, & Black as per specn IRS S 76/89 (Amd.-3) or with latest. (Inspection by RDSO)

-

-

97

... More
Supply of PVC indoor cable 1x24x1 mm dia colour coding of insulation of inner core shall be in eight colours viz Blue, Red, Grey, Green, Brown, Block, Yellow & White as per specn IRS S 76/89 (Amd.-3) or with latest . (Inspection by RDSO)

1.5

160727

241090.63

... More
Supply, installation, testing and commissioning of Audio visual alarm system for link indication of UFSBI. (Inspection by Representative of Dy.CSTE/C/Jhs)

14

16490

230860

... More
(A) Supply, Installation, Transportation, Testing, Execution and Commissioning of Block Proving by Axle Counter [BPAC] using Block panel and UFSBI for Double line Operation as per Spec No. IRS: S-105/2012 [ver.0] with latest amdt. Each set consisting of following: (i) Universal Fail safe Block interface complete with all accessories as per Spec No. IRS:S-104/2012 [ver.0] with latest version and amdt. Qty-02nos. (ii) Block panel complete with all accessories as per RDSO Drg No. RDSO/S/32017 for double line (latest amdt.)- Qty-02nos. (iii) Relay rack with due locking and sealing arrangement as per RDSO Drg No. RDSO/S/32018 including all relays and wiring as wiring diagram as per RDSO drg No. RDSO/S/32018 with latest amdt. and supply of all type of Relays (iv) Block Telephone with accessories as per RDSO Spec No. RDSO/SPN/191/2006, Qty-2nos. with all type lighting protection and inbuilt automatic media change over with voice, E1 and dark fiber port. OR (B) Supply, Installation, 100 Transportation, Testing, Execution and Commissioning of microprocessor based Station Master Block Panel for Double line Block instrument with Block telephones as per RDSO/SPN/175/2005 with automatic media change over material and description: (1) Supply of (a) Microprocessor based Station Master Block Panel for Double line instrument with Block telephone as per RDSO/SPN/175/2005- version 1 or latest (b) Block Telephone as per RDSO Spec No. RDSO/SPN/191/2005 or latest (inspection by RDSO)- Qty-2nos. (2) Supply of Microprocessor based SSBPAC (d) Block instrument for double line as per RDSO/SPN/175/2005 version 1 or latest (inspection by RDSO) Qty-2nos (3) Supply of lighting and surge protection devices or power line 24 V DC, Class-C (inspection by Consignee) qty-02Nos (4) Supply of lighting and surge protection devices for Data lines Class D (inspection by Consignee) Qty. 2Nos. (5) Supply of all type of relays Qty. 02 lot with inbuilt automatic media changeover with voice, E1 and Dark fiber Port.(Inspection by RDSO) Note: It should also include dual modem (Quad and OFC (E1/Dark fibre)) and auto media changeover required to work simultaneously on both Quad and OFC channel.

4

1139938

4559753.23

... More
Supply, Installation, testing and commissioning of Block Panel BPAC(Block Proving with digital axle counter) using UFSBI as per specification IRS:S-105/2012 (Ver.0) with latest amendment for single line operation.NOTE: One set will include all equipments viz. SM panel, block telephone-2 no, pre-wired relay rack-2 no, all types of required relays, surge and lightning protection, technical manuals etc. required for one complete Single line Block Section (except DAC). (Inspection by RDSO) OR (B) Supply, Installation, Transportation, Testing, Execution and Commissioning of microprocessor based Station Master Block Panel for Single line Block instrument with Block telephones as per RDSO/SPN/175/2005 with automatic media change over material and description: (1) Supply of (a) 101 Microprocessor based Station Master Block Panel for Double line instrument with Block telephone as per RDSO/SPN/175/2005- version 1 or latest (b) Block Telephone as per RDSO Spec No. RDSO/SPN/191/2005 or latest (inspection by RDSO)- Qty-2nos. (2) Supply of Microprocessor based SSBPAC Block instrument for single line as per RDSO/SPN/175/2005 version 1 or latest (inspection by RDSO) Qty-2nos (3) Supply of lighting and surge protection devices or power line 24 V DC, Class-C (inspection by Consignee) qty-02Nos (4) Supply of lighting and surge protection devices for Data lines Class D (inspection by Consignee) Qty. 2Nos. (5) Supply of all type of relays Qty. 02 lot with inbuilt automatic media changeover with voice, E1 and Dark fiber Port. Note: It should also include dual modem (Quad and OFC (E1/Dark fibre)) and auto media changeover required to work simultaneously on both Quad and OFC channel.

1

959857

959857.49

... More
Supply of Electrically Operated Lifting barrier assembly 110 V AC without hand generator with motorized locking/unlocking arrangement including all the accessories as per RDSO specification No. RDSO/SPN/208/2012(Ver.2.0)with latest amendment. (Inspection by RDSO)

1

360404

360404.32

... More
Supply of Block Instrument Double Line, bell unit, 3-position relay complete with 103 Telephone, condenser, Induction Coil etc. with arrangement for commutator Handle Lock. As per Drawing No. SA-22781 ( adv.) Alt-1 as per Specification No. IRS:S-22/2016 Ver. 1.0 and IRS: S-23/88 or latest. One gong may conform to IRS drawing No. S 22912 and the other to S 22912A. (Inspection by RDSO)

2

53652

107304

... More
Supply of Filter unit Drg. No. TCA-20080 as per Specification No. IRS:S-68/89 or latest, complete with all accessories. (Inspection by RDSO)

2

12667

25334

... More
Supply of Relays - 3-Position DC Polarized (Metal to Metal), 77 Ohms, 1N/1R contacts, Metal to Metal centre biased armature confirming to Specification No. IRS: S - 31/80 (Amd.1), IRS: S - 34 and IRS-S - 23 or latest. (Inspection by RDSO)

2

10000

20000

... More
Supply of Road signal complete with signal post, CLS unit 3 aspect, ladder assembly, LED signals and hooter etc. (Inspection by RITES.)

3

73722

221166.92

... More
Supply, installation, testing and commissioning of LED type control cum indication panel complete with prewired Tag- Blocks, Wires MS angles etc. for LC gate , depicting the yard layout Signal, Point, Track circuit, Operating / emergency Push Button, counter with sealing arrangements, 109 house in a Steel metal cabinet. This shall be consist 15 x 10 exchangeable Domino Unit as per Spec. SPN/186/2004 Rev. 2.0 or latest. The indoor wiring inside panel shall be terminated on tag block as per instructions of Engineer-in-charge. The wiring on panel tag blocks shall be repeated on tag blocks located in relay room. This includes laying & termination of cable, if any from Panel Room to Relay Room in HDPE pipe. (Inspection by Representative of Dy.CSTE/C/JHS)

1

65778

65778.96

... More
Supply, Installation, testing and commissioning of Sliding type mechanical Boom barrier (SBB) assembly, 11 to 12 Meter Long, movement drive mechanism, resetting & supporting stand 110 suitable for Mechanical/Electrical level crossing gate as an emergency arrangements as per GZB Workshop drawing no. SA-SWG/GZB/E/01. The sliding boom assembly should be have the provision of 50mmx50mmx50mm angles for the entire length. Boom rest posts should be 10 no per gate or more as per site requirement. Painting should be completely done of all the assemblies/parts of Sliding LC gate. (Inspection by RITES)

3

189475

568427.88

... More
Supply of Electrical lifting barrier booms of 9.76 meter (32 feet) long, in four section of 8 feet each, as per RDSO spec. RDSO/SPN/208/2012 Ver.2.0 or latest and as per RDSO drawing no. RDSO/S/11600 or latest. (Inspection by Representative of Dy.CSTE/C/JHS)

3

17202

51607.83

... More
Supply of ARA terminal block, made of PBT, as per RDSO spec. No. IRS: S-75/2006 (Rev.2) or latest and as per Drawing. No. SA- 23741A (Alt.-4) or latest. (Inspection by RDSO)

22000

119

2625040

... More
Multi Section Digital Axle Counter (MSDAC) supply ,design, installation ,testing and commissioning of Multi Section Digital Axle Counter (MSDA) complete system as per RDSO specification No. RDSO/SPN/176/2013(Ver.3) with latest. Suitable for commissioning of yard/auto section/dual detection(DCTC/AFTC with MSDAC) . MSDAC should have facility to reset track sections. Design of axle counter indoor installation testing and commissioning of Multi Section Digital Axle Counter (per unit), supply of essential 10% spares covering all type of cards, wheel sensors for MSDAC. Supply of Diagnostic system for remote diagnostics tool set for wheel sensors monitoring and maintenance of MSDAC consisting of torque wrench, rathet, testing plate, measuring tape, screw driver, gloves and multimeter fluke115(1No per 14DP0Note1:1- If any housing is required to keep outdoor equipment , it has to be supplied with rhe equipment with no extra cost.2.Maintenance free earthing (supply and installation) for Track device/Mushroom housing etc to be done by the contractor 113 if required by system design. No extra cost/payment will be made for this by Railways. 3.Automatic resetting facilities through hardware/software for auto resetting to be provided by contractor by his own materials for this no extra cost/payment will be made for this by Railways. 4.MSDAC system networking to be done with central control room . Required hardware/PC/network equipment to be provided by the contractor, no extra cost/payment will be made for this by Railways. EI Channel /media will be provided by Railway for this purpose from nearest Railway station. 5.All other hardware like TPR. Extra cards to make dual DP, modem, Ethernet Switches etc. if required for commissioning and final track section pickup, will be supplied by contractor, No extra payment will be made for this by Railway. 6.Separate evaluator for UP , DN and 3rd line to be provided at station/RH as decided by Railway site engineer. For the communication between evaluator to evaluator (RH to station)Quad/OFC link (dark fibre)will be provided by Railway. Any other networking equipment if required will be supplied by contractor at no extra cost. 7.Manual resetting through reset box at station to be provided as per requirement. (Inspection by RDSO)

128

354930

45431120.64

... More
Supply, Installation, Testing and Commissioning of High Availability Single Section digital axle counter (HASSDAC) with Dual sensor system as per RDSO/SPN/177/2012 (Version 3) or 114 latest. This includes the supply of High frequency web mounting type Tx coil/Rx coil, VR/PR Box duly wired, Vital relays, PR Relays, Clamp with deflector plates & hardware, Dual display reset box/monitoring console with auto resetting facility, Surge voltage protection devices and filter card to be mounted on DIN rail etc as per OEM for complete installation & testing & commissioning of (HASSDAC) system. This include fixing of track device, relays, wiring, lacing /dressing, cable termination with lug eyelet, drilling holes in rails, Installation of track devices and make it functional along with existing UFSBI/block instrument. Material required other then supply item of HASSDAC shall be arranged by contactor to make it functional. NOTE: One set of HASSDAC system will include equipment required to monitor One Up line or One Dn line of a full Block Section between two stations. (Inspection by RDSO)

3

732954

2198863.44

... More
Supply of Tools Kit for Digital AxleCounter (Multi section/Single section). (MSDAC comply to the RDSOspec. RDSO/SPN/176/2013/ Ver.3or latest and manufacturer's specification and SSDAC comply tothe RDSO/SPN/177/2012, Ver.3 orlatest respectively). The tool kitshall be minimum 115 equipped withthe following equipments: (i) Allmechanical tools shall be ofreputed make like Taparia/Boschetc. (ii) Digital multimeter trueRMS type of make Fluke 189 orsimilar reputed make with probeset - 1 no (iii) Adjustable torquewrenches 25-135 N/mtr with 13mm and 19 mm inserts- 1 set (iv)Set of spanners screw drivers andsoldering iron - 1 set (v) Dummywheel - 1 no. (vi) Marking Jig - 1no. (vii) Adapter card - 1 no. (viii)Extended wired socket to inetrface with diagnostic plug - 1 no. (viii)Selector switch on panel base - 1no. (ix) DAC EC card puller etc. Inspection agency- Consignee

1

122070

122070.68

... More
Supply of hand cuff lock of Godrej/Navtal or reputed make with key and as approved by site engineer. (Inspection by Representative of Dy.CSTE/C/Jhs)

500

460

230260

... More
All in One PC(Q2) DEL/Intel/LG/HP 400 G6 AIO i7 10700 Win10P 161512 SSD3 Wifi 23.8" 7200 rpm HDD 64 2 processer including HP Laser P1007 or similar Printer or better (latest version) (Inspection by Representative of Dy.CSTE/C/Jhs)

7

75172

526208.07

... More
Supply installation testing & commissioning of Dual Redundant Arrangement of UFSBI Electronics for exchange of vital relay state information between two different Signalling installations pertaining to ABS /IB signalling application working on OFC/Quad media in set and consisting of following sub systems: a) Electronics for UFSBI interface in redundancy as per IRS spec. no. IRS:S- 104/2012 ver. 0 (latest amendment). Qty: Two Nos.; b) Modem for UFSBI (for use of secondary media 118 OFC / Quad). Qty Two Nos.; c) Automatic Media changeover of modem working on redundant channels for data transmission on OFC/Quad. Qty: Two Nos.; d) Pre wired 36-U loor mounting MS Cabinet suited to it Two sets of UFSBI Electronics with Siemens grey/Smoke grey powder coating (Rust proof and long life), tinted 3-4 mm thick tinted Acrylic/Polycarbonate/ Glass sheet itted on front door and metal back door, with double lock and bottom cable entry facility. Qty: One Nos.; Item (a) shall be inspected by RDSO and item (b), (c) & (d) by consignee along with OEM Test Report. Note: 1 Pair shall consist of 2 Sets of above mentioned items. Inspection: RDSO

2

1416000

2832000

... More
Supply and installation of Data Concentrator as per technical specifications. (Inspection Agency:RITES)

2

144971

289942.42

... More
Supply of Dual serial to OFC media converter card suitable to insert in the data logger/RTU/DC euro rack for interlinking Data loggers/RTU/DCs installed at various locations . (Inspection Agency:RITES)

5

38014

190073.36

... More
Supply of Dual card E1 Converter as per RDSO Spec. No. IRS (S) 99/2006 (Amdt. 3) or latest (Inspection Agency:RITES)

4

59351

237404.28

... More
Supply of Antistatic mats of size 1 mtr x 0.75 mtr and 3 mm thickness. (Inspection by Representative of Dy.CSTE/C/JHS).

310

2009

623093.8

... More
Supply and Installation of Fibre distribution management system as per RDSO spec. 123 RDSO/SPN/TC/37/2020 Revision 4.0 or latest. It includes the supply of 19"42U rack with mounting arrangement. It will also include all installation material, splicing, termination, testing of all 2 x 24 fibres. (Inspection by Rites.)

8

77346

618768.48

... More
Supply of 24 fiber optical fiber cable straight joint enclosure (SJC) complete with all 124 accessories along with enclosures with heat shrinkable splice protection sleeve as per RDSO spec.RDSO/SPN/TC68/2014 Revision 1.0, Amndt. 1.0 or latest. Splice losses in no case should be more than 0.1 dB. (Inspection by Representative of Dy.CSTE/C/JHS).

30

5506

165201.3

... More
Supply of permanently lubricated HDPE duct, 40 mm outer dia, as per RDSO spec. No. RDSO/SPN/TC/45/2013 Rev.2 Amndt.2 or latest, along with all accessories like end caps, collars, bends, couplers etc. (Inspection by RITES).

26

76811

1997096.92

... More
Termination of Outdoor Cables (Main Cables /tail cables) at ARA/Disconnect type 1 terminals provided in Apparatus Cases, Cable termination rack in relay room, station building, generator room etc. The item includes dressing of cables and wires with dressing threads as per standard practice. All material required for this item will be supplied by contractor. The outdoor cable shall be terminated in Relay Room, DG Room, ASM Room etc under supervision and instructions issued by Engr. incharge of the work.

86000

1270220

1270220

... More
Testing & commissioning of led indication system with indication, buzzer & 2 acknowledgment button up to 6 line station with interface facility to existing data logger and modification of data logger embedded software when a station master fails to set the point against the occupied line within stipulated time after arrival of the train.

3

5000

15000

... More
Installation wiring and shifting of block instrument , control phones, gate phones etc. The work of wiring right from Telecom DP to block Instrument, Control phones , shifting of existing 3 equipments & circuits from old building to the new panel building will be done by contractor as per instructions of site engineer. Other telecom gears connection etc. (if required) and block instrument to Relay Room and connection with power supply will be done by the Contractor with Contractor's own material .

3

4207

12621.48

... More
Installation, wiring & Testing of KLR boxes, Group phone, ELD, Test board, Auto change over panel, Service test panel, SPT, TRX etc. This includes laying & termination of cable, if any from 4 Panel Room To Relay Room in GI/HDPE pipe. Note Important: All the S&T cables transists entries in PI, Equipment Room & Station Building, Control room, OFC hut/Shelters, Pota cabin, Cabinets (indoor & outdoor) shall be sealed with cement concrete mixture of 1:3:6 with contractors' own material. Energisation of the system in presence of Rly. Engineer. Soldering, lacing rosin core etc. required will be arranged by the contractor at his own cost.

3

28925

86775.09

... More
Lettering & Numbering of detail and description writing of particulars of terminations & equipments on relay rack, relays, cable termination rack, battery & power equipments, IPS, operating 5 panel, axle counter etc constituting entire system with contractor's own paint and writing material. This includes supply and fixing of Teflon strips 3mm thick and 25 mm wide for each row of relays and cable terminations. The work shall be done as per extant practice on the division& instruction of Rly engineer at site.

5

8623

43116.75

... More
Fixing of GI pipes for crossing the culverts, minor bridges etc. and concreting the ends with cement concrete 1:3:6 and brick soling at both ends as per Drg. No. TS/Cable laying/12/03/05 and 6 as per the instructions of Rly. Engineer at site with Contractor's materials (GI pipes shall be supplied by Rlys.) 3 perforation of 6mm dia per meter shall be made on the GI pipe. This includes fixing with contractors own MS channel, clamps / concrete blocks of proper size etc as per instructions of engineer at site.

1000

284

284592.33

... More
Casting, concreting and curing of foundation for Main Signal Post in the ratio of 1:3:6 as per NCR drg.No. TYP/013/14/SIG FOUND. dtd 12.11.2014 (total 2 sheets of drawing) issued vide NCR Letter no. S&T/NCR/DRG/TYP dated 13.11.2014, using standard size of foundation/galvanized anchor 7 bolts complete, required for erection of colour light signal post. Anchor bolts complete should comply with the RDSO drg. no. SA 116 A/M. Item includes excavation, ramming of CC using vibrator, curing and plastering with 1:4 cement-sand mixture (aggregate will not exceed 3.8 cm). Aggregate, cement, sand and holding down bolts will be supplied by contractor. Any machines & tools, if required for execution of this item, will be arranged/provided by contractor.

122

13512

1648516.46

... More
Casting, concreting and curing of foundation for Position Light Shunt Signal as per Drg.No.CR/S&T/C/SK/184 using standard size of foundation/galvanized anchor bolts complete, required for erection of shunt signal post. Anchor bolts complete should comply with the RDSO drg. no. SA 116 A/M. Item includes excavation, ramming of CC using vibrator, curing and plastering with 1:4 cement sand mixture. Aggregate cement, sand and holding down bolts, will be supplied by contractor. Any machines and tools, if required for execution of this item, will be arranged/provided by contractor.

-

-

8

... More
Erection of CLS Post with base and signal unit on top or on Offset Bracket including erection of auxiliary signals like calling on, shunt signal if any. It includes fixing of all LEDs and wiring 9 of complete signal including route and auxilliary signals, if any. It includes fixing of front and back staging, ladder and guards, signal name plates / boards, with contractor's own brackets and fixing materials. The work shall be done as per instructions of Rly engineer at site. It also includes provision & fixing of maintenance platform as per design given by Engineer -In-Charge at site. The Item includes cutting of Signal post if required by Site In charge.

122

5881

717533.24

... More
Erection of Position Light Shunt signal with Base, Post, Signal unit, complete fixing of LEDs and wiring of full signal. It includes fixing of Number Plates. The work shall be done as per instructions of Rly engineer at site.

36

951

34253.28

... More
Fixing of Junction type Route Indicator on top of signal post and complete wiring, 1- Way/2-Way/3-Way/4-Way/5-Way/6-Way/theater type.

41

1112

45612.91

... More
Excavation, casting, curing of foundation and Installation and Erection of Apparatus 12 case Full with contractor's own frame, cement and other material in the ratio 1:3:6. 'E' type lock to be supplied and installed with App. case. This includes filling of location foundations with river bed sand and plastering on top with a mixture of 1:4 of cement and sand. It covers fixing of lamp holder , switch and lamp etc. in Apparatus Case.

402

12277

4935679.62

... More
Excavation, casting, curing of foundation and Installation and Erection of Apparatus 13 case Half with contractor's own frame, cement and other material in the ratio 1:3:6.'E' type lock to be supplied and installed with App. case.This includes filling of location foundations with river bed sand and plastering on top with a mixture of 1:4 of cement and sand. It covers fixing of lamp holder , switch and lamp etc. in Apparatus Case.

154

10332

1591161.88

... More
Fixing of ARA(M-6) Terminals /Screw less connectors / modular disconnect terminal 14 blocks and fuse blocks on phenolic laminated sheets and fixing by stainless steel/brass nuts & bolts. This includes provision of two additional holes on the board on either side for cable conductor entry. The work shall be carried out a per instructions of railway Engineer incharge.(Supply of all above terminals has been covered separately).

44000

18

796840

... More
Installation of Eqpt. (Relays, resistance, chargers, bulb holders & batteries etc.) & wiring of the same in apparatus cases as per location & circuit diagrams with contractor's own wiring 15 material suitable for 25KV RE area. This also includes supply & installation of Three pole switch & socket 5 A ( Anchor make ) and Lamp Holders with lamp, two pin, Bakelite type with fixing arrangement at contractor own cost. The work shall be done as per instruction of Rly engineer at site and approval of wiring material ( from RDSO approved firms) being used and extant practice in the division. Single case

402

2155

866543.03

... More
Installation of Eqpt. (Relays, resistance, chargers, bulb holders & batteries etc.) & wiring of the same in apparatus cases as per location & circuit diagrams with contractor's own wiring 16 material suitable for 25KV RE area. This also includes supply & installation of Three pole switch & socket 5 A ( Anchor make ) and Lamp Holders with lamp, two pin, Bakelite type with fixing arrangement at contractor own cost. The work shall be done as per instruction of Rly engineer at site and approval of wiring material ( from RDSO approved firms) being used and extant practice in the division. Half case

154

1580

243472.53

... More
Fabrication and fixing of phenolic laminated sheet of grade P3, minimum 10 mm thick,as per Apparatus case diagram/plan, in location box by providing all fixtures like ARA/Disconnect 17 terminals, fuse blocks, fuses, relays on square bars etc. including fixing of PVC coated string rods at the back side for cable support with contractor's own material like iron angle, nuts, bolts etc. The iron angle for fixing shall be minimum 3 mm thick. This also includes fixing of teak wood shelf minimum 25 mm thick for holding track circuit equipments. The work shall be done as per instructions of Rly engineer at site. (Apparatus case Full)

402

4478

1800348.96

... More
Fabrication and fixing of phenolic laminated sheet of grade P3, minimum 10 mm 18 thick,as per Apparatus case diagram/plan, in location box by providing all fixtures like ARA/Disconnect terminals, fuse blocks, fuses, relays on square bars etc. including fixing of PVC coated string rods at the back side for cable support with contractor's own material like iron angle, nuts, bolts etc. The iron angle for fixing shall be minimum 3 mm thick. This also includes fixing of teak wood shelf minimum 25 mm thick for holding track circuit equipments. The work shall be done as per instructions of Rly engineer at site. (Apparatus case Half)

154

2429

374110.66

... More
Installation of Unit Maintenance Free Earth to achieve a resistance less than 1 ohm as supplied under item no. 13002 of Chapter 13 of SOR. It includes (i) Digging the earth to the required depth. (ii) Insertion of electrode. (iii) Filling of earth enhancing compound (Approx.30 Kg) (iv) Provision of exothermic weld connections to copper tape of 25 mm x 6 mm x 150 mm to the earth electrodes. All material tools and features required for weld will be arranged by contractor. (v) This also includes CC cover 1.5 ft x 1.5 ft. 1 ft wall thickness 2 inch with cover 3 inch thickness. Cables 35 Sq mm/ 16 Sq mm/10 sq mm for connecting earth to busbar, busbar to busbar and busbars to various equipments. Earth electrode of 17.20 mm dia and 3.00 meter long high tensile low carbon steel circular rods molecularly bonded with copper and outer surface (minimum copper bonding thickness of 250 19 micrones to made requirement of under writer's laboratories (UL) 467-2007 or latest. Copper strips of 150 mm x 25 mm x 6 mm to be welded with each earth electrode, copper strips of 300 mm x 25 mm x 6 mm for main equip- potential busbar, copper strips of 150 mm x 25 mm x 6 mm sub equip-potential busbar in relay room, power room and panel room. GI strip 25 mm x 2 mm for ring formation of earth pits Earth enhancement material in bags for each Earth Electrode. Inspection chamber of site 300 mm x 300 mm x 300 mm (Inside dimension) of approximate 50 mm thick with pulling hooks to cover the earth pits. Note: The installation of this item shall be carried out by the contractor as per RDSO Specn.No.RDSO/SPN/ 197 Ver 1.0 or latest. Typical RDSO approved drawings referred in the RDSO specification document are : (i) SDO/RDSO/E&B/001 for typical installation of Earth, (ii) SDO/RDSO/E&B/002 for typical bondong and earthing connections, (iii) SDO/RDSO/E&B/003 for typical arrangement for earth resistance measurements.

136

7276

989670.64

... More
Charging of Lead Acid Batteries, 2V, 80 AH, with contractors own battery grade 20 sulphuric acid and distilled water with minimum two charge - discharge cycles, installation of charged batteries in groups & their connection & wiring. The work shall be done as per the procedure prescribed by the OEM and extant practice of N.C.Rly and instruction of Engineer-in-charge. Detailed measurements of initial charging shall be recorded jointly by contractor & Rly's site-in-charge.

870

247

215124.9

... More
Installation wiring testing and commissioning of Fuse auto change over system. This 21 includes provision of common Buzzer & indication at ASM Room & ESM Duty Room and painting of fuse details. This also includes fabrication of frame for installation of FACS at Station/ LC gate where installation of relay racks not feasible. One set means set of each fuse.

1692

159

270330.84

... More
Fixing, wiring, testing and commissioning of Electrical Point Machine on the Wooden/PRC sleepers at points as per standard practice and as per section of rails used. Item includes fixing switch extension bracket, providing insulation for switch extension bracket, fixing ground connection, adjusting opening of the switches and adjusting the point machine with crank handle.The item also includes : (i)Complete material for installation like ground-connections, switch extension brackets, point insulation material, I pipes, wiring materials, various fixing nuts & bolts including castle nuts, spring washers (ii) All smithy & fitting works required at site for complete installation. (iii) 22 Installation of gauge tie plate & providing insulation for gauge tie plate (Insulation in William Stretcher Bar will be provided by Railways). (iv) Wiring inside the point machine, insertion and termination of tail cable in point machine and junction boxes / location box /cable hut as per extent practice on NCR and the instruction of Railway Engineer at site. (v) Supply and fixing of bend pipes with welded frame for cable entry to machine (vi) Supply and filling of industrial grade/good quality lubricant/grease/oil for smooth opertion of point machine Note ; The ground connections shall be suitable to the Point Machines as specified by Engineer-in-charge and shall be suitable to the point lay out i.e. 60 Kg. / 52 Kg / 90R as per yard layout. Electrical Point Machine and M-6 / Screw less terminals will be supplied by Railways / covered in Schedule separately

140

14054

1967588

... More
Fixing/Refixing of electrical point machine, ground connection during phase working (Non interlock working) after removing the mechanical fitting if any, adjustment if necessary, testing and commissioning of electricaly operated point, fixing and connecting point indicator on derail switch 23 if necessary. This will include fabrication and fixing of bent pipes with welded frame for cable entry to the point machine and termination of tail cable in point machine and wiring of detection contacts with contractors own wiring material,servicing of point machine & supply & filling of SAE 30 lubricating oil (500 ml approx). This also includes supply of GI bend pipe, 'B' class, 50mm dia, for cable entry in point machines. The work shall be done as per extant practice on the division & the instruction of Rly engineer at site.

30

5492

164787.3

... More
Digging of 1.00.Meter deep and 0.3 Meter wide trenches including clearing of roots of trees and bushes and temporary obstruction on the selected route, as per technical specifications and cable route plan. Note:In case where digging of trench up to 1.00 Meter depth and 0.3 meter wide is 24 not possible or bigger size trench is required to lay more cables or loose soil/ muck is encountered, the depth can be reduced / increased as per directions of the Engineer-in-charge of the works, the payment will be decreased/increased proportionate to the depth & width of excavation compared to 1.00 Meter deep and 0.3 Meter wide. This also includes Back filling and consolidating of cable trench first for 5 CM (in case where bricks are to laid over cables) after laying of cables and then complete back filling & Ramming of loose soil as per the technical specifications. In all type of soils including soft rock

26000

65

1692135.9

... More
Digging of 1.00.Meter deep and 0.3 Meter wide trenches including clearing of roots of trees and bushes and temporary obstruction on the selected route, as per technical specifications and cable route plan. Note:In case where digging of trench up to 1.00 Meter depth and 0.3 meter wide is 25 not possible or bigger size trench is required to lay more cables or loose soil/ muck is encountered, the depth can be reduced / increased as per directions of the Engineer-in-charge of the works, the payment will be decreased/increased proportionate to the depth & width of excavation compared to 1.00 Meter deep and 0.3 Meter wide. This also includes Back filling and consolidating of cable trench first for 5 CM (in case where bricks are to laid over cables) after laying of cables and then complete back filling & Ramming of loose soil as per the technical specifications. In rocky soils

4000

96

384045.8

... More
Horizontal Boring/Manual moling without damage to surface road /track for laying/isertion of DWC/GI/HDPE pipe. The bore shall be done at the depth of minimum 1400 mm from 26 the ground level. The ground level shall be considered ignoring the bank height of the bank of the road. Note:- DWC/HDPE/GI Pipe Supply is not covered under this item. Contactor shall provide all material required for work and adequate nos. of labours for proper laying of cables into the bore. Cable shall be laid cautiously so that it should not get damage due to rough handling & pressure on cable. Payment of boring shall be made only after DWC/HDPE/GI pipe is laid in the bore.

3200

1083

3466528

... More
Excavation of cable trench 1m deep and 300mm wide across the track, for track crossing and refilling after laying of DWC/channel pipes. The work shall be done as per extant practice on the division & instruction of Rly engineer at site

2500

162

405343.25

... More
Cement concrete work for miscellaneous, unscheduled items in ratio 1:3:6 of cement, 28 coarse, sand and aggregate Item includes excavation, ramming of CC by using vibrator, curing and plastering with cement and sand mixture in ratio 1:4 (aggregate will not exceed beyond 3.8 cm). The aggregate cement and sand will be supplied by contractor.

730

5109

3730022.6

... More
Preparation of cable duct 150mm*200mm deep for laying of cable in rocky area and refilling the duct (after cable laying ) with concrete mixture of 1:3:6 with contractor own cement & other materials.

3750

415

1556297.81

... More
Cutting of all types of platforms/road crossing and trenching and excavation to a width and depth of 300 mm x 300 mm, laying of DWC/HDPE/GI pipe in the trench and refilling and 30 concreting it afterwards as per original condition. In hard rocky ground area , cables will be laid normally on layer of soft earth of 0.05 mtrs thickness previously deposited at bottom of the trench . The cutting to be filled and finished with cement/concrete, as per the RDSO drawing no.SDO/Cable laying/008, issued vide RDSO document no. RDSO/SI/G/2010 Version 1.1 dated 04.02.2014 or latest. 31

800

158

127104

... More
Cross trench for identification of the route of existing signlalling and telecomm cables.

800

290

232336

... More
Laying of S&T Cables of various cores/ pairs/ quads in trenches/ GI pipes/ RCC pipes/ DWC pipes etc. as per the site requirement and as per approved cable route plan. This also includes 32 laying of cables in track crossings & road crossings.(Cables will be meggered before and after its laying by contractor under supervision of Railway Representative and he will submit the meggering report of each testing). Length of the cable laid includes the length of the cable coiled for termination purposes.

680000

6

4651200

... More
Installation, testing and commissioning of electrically operated lifting barrier, complete 33 with casting of cement concrete foundation for pedestal and boom rest post, cabling, power supply connection, earthing of barriers & wiring with complete outdoor work as per approved drawing, wiring etc.

3

55688

167065.86

... More
Earth work for excavation and refilling around location boxes and signals etc. where necessary, including 50 Mtr. Lead and 1.5 lift. The lead is to be measured from centre of gravity of location to the centre of filling and lift from main ground level. The earthwork should be well rammed including breaking of clods, levelling and dressing etc. as per instructions of Engineer at site.

-

-

34

... More
Excavation of pit in and around the existing location boxes very carefully without damaging the working cables and shifting and turning the location boxes to clear of the infringement as instructed by the Railway representative at site. The work includes ensuring the safety of the 35 signalling system, releasing the cable coils to give access for shifting/turning the location boxes, Necessery masonry work and earth work in and around the location boxes to the required level shall be done as instructed by the Railway representative at site.If the existing earth connections to the location boxes are disturbed, thr earth wires shall be properly re-connected.(All materials required for the work shall be supplied by the contractor.] Shifting of Appratus cases(Full)

65

4907

318995.46

... More
Painting two coats of enamel paint over one coat of Red Oxide primer on the location boxes, signal posts, base & unit, Glued & block joints, TLJB, point machine etc. following items after scrapping and cleaning of the surface wherever necessary. This includes lettering/Numbering of 36 signals, point machine, TLJB, Block joints, apparatus cases etc. Termination particulars, equipment names etc. legibly and neatly inside & outside location boxes etc. Primer and Paints both Asian paints make are to be supplied by Contractor. The work shall be done as per instructions of rly engineer at site and extant practice on the division.( This also includes all location boxes in entire JRO-MXS & KOA- BINA section).

5

24387

121939.19

... More
Loading, Transportation/Carriage and Unloading of various S&T material by a 9 MT truck, from/to the consignee depot to/from various locations, as decided by the Railways.

20000

54

1093000

... More
Jointing of Signalling/Telecom cable with heat shrinkable joint kit TSF-2/TSF-3. This includes excavation of pit of suitable size and refilling the same after jointing of cable.

90

1068

96142.83

... More
Provision & running of one MUV to the sites of work as per requirement and direction of 39 Engineer In charge along with Driver for Transportation of less heavy materials & manpower. The rates includes all taxes, license fee, road permit, driver wages, fuel, repair and maintenance cost etc complete in all respects.

50000

34

1724420

... More
Dismentaling and releasing of S&T gears in Asm room, Battery room,Relay 40 room,Equipment roon,Power room. This include all equipments and relays, relay rack, terminal board,SM slide frame, panel batteries, battery chargers, angle iron, IPS etc. All material to be transported to Dy.CMM/Stores with consultation of SSE incharge at depot.

4

8066

32266.3

... More
Dismantling and Releasing of existing Location boxes/Apparatus cases/Jn boxes and other associated S&T fi ttings. All the released material will be transported to Dy.CMM/Stores with consultation of SSE incharge at depot.

252

822

207166.19

... More
Dismantling and Releasing of existing Points (both electrical and Mechanical) and other associated S&T fi ttings. All the released material will be transported to Dy.CMM/Stores with consultation of SSE incharge at depot.

30

1293

38810.02

... More
Dismantling and Releasing of existing Signals (both electrical and Mechanical) and other associated S&T fi ttings like wheel, pulleys, wires, stakes etc. All the released material will be transported to Dy.CMM/Stores with consultation of SSE incharge at depot.

92

1293

119017.39

... More
Installation of Relay Rack Assembly including IDF pillars complete with wall supports, 44 scaffolding, ladders, runway for cables, Relay/Relay group base plates, fixing of Tag blocks etc. This also includes supply & fixing of indicative type of fuse with inserts of required capacity. The work shall be done as per approved plan, extant practice on the division & the instructions of Railway engineer at site.

3

1989

5968.42

... More
Transportation of HDT machine with accessories including handing of stores materials preparation of site & boring for placing and supply of onenumber 110 mm dia HDPE pipe for crossing 45 of S&T cables together at bridges?Culverts track pucca road crossing boring trench shall be 3 Mtr. below the river bed and ! mtr. below the track / road / pucca road crossing area. this includes supply of accessories for HDPE pipes cost of fuel and all other items which will be required for laying of cables throughit. the work shall be executedas per instruction of site engineer. The rate includes laying of cable through the pipe laid by HDT machine boring upto the length of 150 Mtrs.

7400

1471

10890580

... More
Fixing of earth electrodes earthing of S&T apparatus cases, signal post etc. connected through GI wire and SWG supported on MS flat size 5 mm x 40 mm to earth electrode as per Drg.No.NGP/S&T/C/309.

250

1317

329310.75

... More
Installation, Testing and Commissioning of Block Proving by Axle Counter (BPAC) using Block Panel and UFSBI for Single line operation complete with all accessories as per Specification No. IRS:S-105/2012 (Ver.0) or latest.

5

84066

420330

... More
Installation, Testing and Commissioning of Block Proving by Axle Counter (BPAC) using Block Panel and UFSBI for Double line operation complete with all accessories as per Specification No. IRS:S-105/2012 (Ver.0) or latest.

4

90932

363728

... More
Installation, Testing and Commissioning of UFSBI for IB operation or Other works as per decision of site incharge complete with all accessories as per Specification No. IRS: S - 105/2012 (Ver.0) or latest.

6

59394

356364

... More
Dismantling and Releasing of existing Electrically operated LC gate/Mechanically operated LC gate and other associated S&T fittings. All the released material will be transported to Dy.CMM/Stores with consultation of SSE incharge at depot.

3

7427

22282.59

... More
Installation of DC track circuits (Straight Portion) including supply of materials as per directive of site Engineer. NOTE : (i) This includes drilling 9/32" holes on rails, provision of double continuity GI wire bonding, provision of Block Joints 60 Kg/52 Kg/90R with machined fish plates, installation of Track lead junction box (separately for (+) and (-) rails), provision of track lead jumper wires/cables, fixing of track circuit equipment i.e. track charger, resistance, fuses, batteries, chokes, relays, anti-titling arranginment and painting, lettering and numbering of DC track circuit equipments 51 etc., (ii) [a] Un-machined fish plates shall be supplied by the Railway's, but machining of fish plates shall be done by the Tenderer. In case of provision of Glued Joints by Engineering Department in lieu of RDSO Block joint, the cost of machining of fish plates@ 100/- per straight track circuit and @ 500/- per point zone track circuit will be deducted. [b] This includes insulation of gauge tie plates, Crossing plates, rod in siding points if required or any other place as instructed by Railway Site Engineer, by Tenderer's insulation materials. Railway will supply Track Charger, B-type choke, Resistance, Un- charged battery, TLJB and relays through a separate schedule/from the stores of railway consignee. These are to be transported to site of work at contractor's cost. Tenderer/Contractor shall supply any other materials that are required for the work.

130

7718

1003402.4

... More
Installation of DC track circuits (Point zone) including supply of materials as per directive of site Engineer. NOTE : (i) This includes drilling 9/32" holes on rails, provision of double continuity GI wire bonding, provision of Block Joints 60 Kg/52 Kg/90R with machined fish plates, installation of Track lead junction box (separately for (+) and (-) rails), provision of track lead jumper wires/cables, fixing of track circuit equipment i.e. track charger, resistance, fuses, batteries, chokes, relays, anti-titling arranginment and painting, lettering and numbering of DC track circuit equipments 52 etc., (ii) [a] Un-machined fish plates shall be supplied by the Railway's, but machining of fish plates shall be done by the Tenderer. In case of provision of Glued Joints by Engineering Department in lieu of RDSO Block joint, the cost of machining of fish plates@ 100/- per straight track circuit and @ 500/- per point zone track circuit will be deducted. [b] This includes insulation of gauge tie plates, Crossing plates, rod in siding points if required or any other place as instructed by Railway Site Engineer, by Tenderer's insulation materials. Railway will supply Track Charger, B-type choke, Resistance, Un- charged battery, TLJB and relays through a separate schedule/from the stores of railway consignee. These are to be transported to site of work at contractor's cost. Tenderer/Contractor shall supply any other materials that are required for the work.

150

12472

1870819.5

... More
Supply of labour (helpers) for assistance to Railway inspector's/officers during inspection, supervision and measurement of field work etc as per instruction of engineer In-charge or his representative.

300

503

151144.47

... More
Alteration of existing Data Logger, then testing and commissioning of the DATALOGGER as per RDSO's Spec. including networking and central monitoring along with installation of remote 54 monitoring software and hardware. The contractor is also required to list out the no. of analog & digital inputs for wiring & operation of the datalogger by taking approval of the Rly. for those inputs. NOTE: The contractor has to supply all the hardware & software required for networking & remote monitoring at his cost including training to 4 staffs at site.

4

9573

38293.52

... More
Installation, Testing and Commissioning of High Availability Dual redundant Single Section Digital Axle System (HASSDAC) as per Specification No. RDSO/SPN/177/2012 Ver. 3.0 or latest.

3

55667

167001

... More
Design, installation, testing & commissioning of MSDAC complete set with all accessories consisting of indoor & outdoor equipment including reset box, Lv box, Monitoring console 56 etc required track section. (1No.= 1DP) Note-It includes supply of HDPE pipe for laying of transmitter andas per RDSO specification no. RDSO/SPN/176/20139Ver.3) with latest amendment/revision of receiver cable, digging of trench under track up to location/mushroom housing & grouting, installation, wiring commissioning of cubicle, All other accessories required for commissioning will be provided by the contractor. It also includes the transportation of all material from store to site for installation purpose.

44

13860

609864.2

... More
Transportation, installation, cable termination, wiring, painting, lettering, testing and commissioning of Token less/Double line Block instrument working (in pair) on block instrument cup- board along with fixing of block bell equipment and filter units as per the instructions of Site engineer.

2

7183

14366

... More
Splicing of 24 core optic fibre cable and making the splicing joint with contractor's own 58 machine and tools. Joint should be prepared in such a way that the top of the enclosure shopuld be at a depth of minimum 1.2 mtr and the enclosure should be covered with soft soil and bricks. Splice loss of each fibre should be less than 0.05 dB.

30

12011

360352.5

... More
Construction of OFC jointing pit of size 1mx1mx0.6m, using bricks, sand and cement in 59 the ratio 1:3. The thickness of the wall shall be 120 mm. The top cover shall be of concrete of thickness 75 mm with two iron handles on top of it. The pit shall be covered with sand after putting the joint enclosure. All construction material to be supplied by contractor. 60

30

6257

187729.5

... More
Installation of Antistatic mats of size 1 mtr x 0.75 mtr and 3 mm thickness.

310

148

45911

... More
Laying of HDPE duct as per the approved cable route plan in the exavated trenches/other protected works/RCC channel etc. including all accessories like end caps, collars, 61 bends, couplers etc. The ends of the duct to be sealed with end plugs till OFC blowing is done. Important: The laying of OFC cable independently or along with Quad cable/PIJF cable in the same trench shall be governed by the RDSO drawings no. RDSO/TCDO/COP-6(a) and RDSO/TCDO/COP-8(a) respectively, issued vide Chapter-XIII of the Telecomm Manual.

26

8092

210398.5

... More
Blowing/drawing of OFC cable in the HDPE pipe duct and protective work already 62 provided in the trench. The cable shall be laid only after the successful completion of the DIT (Duct Integrity test). The DIT should be certified by the Railway engineer at site. All the equipments/machinery required shall be arranged by the contractor.

26

17093

444419.3

... More
Taking all type of cables inside station building.Relay room, OFC room, UTS/PRS room ,SSP/FP and location boxes etc and sealing of cable entry point as per instruction of side engineer and contractors own man power and material.

16

3403

54453.66

... More
Installation, cable termination, wiring, testing, & commissioning of integrated power 64 supply (IPS) panel as per approved power supply diagram and specification. The contractor has to supply arrangements at central relay room, goomties on original tracing paper of size 60cm*42cm with 8 computer prints in the format supplied by railways.

7

9427

65994.6



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.