Noida Metro Rail Corporation Limited Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Noida Metro Rail Corporation Limited - NMRC Tender

Services
Laboratory Equipment and Services
Eprocure
Opening Date25 Jan 2023
Closing Date22 Feb 2023
Tender Amount₹ 69,71,204 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
b)-The lab should also have IS-6855 accredited sampling procedure

-

-

-

... More
c)-Relay Test Kit:-3-phase secondary current injection test kit of OMICRON/ DOBEL/ Megger make

-

-

-

... More
d)-For testing the equipment like Transformer the contractor shall ensure readiness of equipment for testing ,however shutdown shall be provided by employer

-

-

-

... More
e)-Visit charge shall as per activity completion, material shall be provided by employer

-

-

-

... More
f)-In-case of breakdown the contractor engineer shall visit within 24 hours of reporting via call/sms/e-mail

-

-

-

... More
g)-Scope of testing of relays shall be as per tentative sample reports attached

-

-

-

... More
A-Detailed Scope of work for Conditioning Monitoring of Power Transformer(s)

-

-

-

... More
Measure of winding insulation resistance value of Power Transformer. (Measure IR at 60 sec & 10 sec) and calculate PI Index (IR at 60 sec/ IR at 10 sec.) (Scope- Testing, Periodicity- half yearly)

32

-

-

... More
Power Transformer Testing of Oil as per oil parameters- As per relevant IS- 1866

-

-

-

... More
Oil Testing of Main Tank of Power Transformer:-which will include :-BDV (break Down Voltage); (Dissolve Gas Analysis:-Methane, Acetylene, Ethylene, Ethane, Hydrogen, Carbon Monoxide & Carbon Dioxiode); PPM (water content); Acidity (Neutralization Value); Resistivity(Specific Resitance), Dielectric Dissipiation Factor(Tan Delta) (Scope- Testing, Periodicity- half yearly)

32

-

-

... More
Oil Testing of OLTC of Power Transformer:- which will include :-BDV (break Down Voltage); (Dissolve Gas Analysis of gases :-Methane, Acetylene, Ethylene, Ethane, Hydrogen, Carbon Monoxide & Carbon Dioxiode); PPM (water content); Acidity (Neutralization Value; Resistivity(Specific Resitance), Dielectric Dissipiation Factor(Tan Delta) (Scope- Testing, Periodicity- half yearly)

48

-

-

... More
* Contractor has to submit the detail report analysis as well as trend analysis report of the Oil Test along with test report of testing from NABL accredited Lab

-

-

-

... More
Power Transformer Electrical Testing-As per relevant IS- 1866

-

-

-

... More
Carry out Tan delta and capacitance measurement of bushing (of Power Transformer) and of windings (of power Transformer) (Scope- Testing, Periodicity- Yearly)

16

-

-

... More
Magnetic balance test (Scope- Testing, Periodicity- As per requirement)

2

-

-

... More
Magnetic current test (Scope- Testing, Periodicity- As per requirement)

2

-

-

... More
Measurement of winding resistance at all taps (Scope- Testing, Periodicity- As per requirement)

2

-

-

... More
Measurement of voltage ratio at all taps (Scope- Testing, Periodicity- As per requirement)

2

-

-

... More
On line Partial Discharge measurement (Scope- Testing, Periodicity- As per requirement)

2

-

-

... More
Visit pertaining to any breakdown (Visit charge shall as per activity, material shall be provided by employer) (Scope- Visit, Periodicity- As per requirement)

12

-

-

... More
C-Testing of SIEMENS make relay(s) installed at various locations.

-

-

-

... More
22 no. ASS

-

-

-

... More
7SD80 (Line Differential) (testing parameters:- Differential Protection) (Annexure-A) (Scope- Testing, Periodicity- Yearly)

192

-

-

... More
7SR11 (O/C & Earth Fault) (testing parameters:- overcurrent and earth fault) (Annexure-B) (Scope- Testing, Periodicity- Yearly)

100

-

-

... More
7SR12 (O/C & Earth Fault) (testing parameters:- overcurrent and earth fault) (Annexure-C) (Scope- Testing, Periodicity- Yearly)

192

-

-

... More
7ST61 (Distance Protection) (testing parameters:- Distance protection) (Annexure-D) (Scope- Testing, Periodicity- Yearly)

8

-

-

... More
2 no. RSS

-

-

-

... More
7ST63 (Distance Protection)(testing parameters:-Over current, PFR(panto flashover),auto recloser,Distance,BCU,WPC) (Annexure-E) (Scope- Testing, Periodicity- Yearly)

32

-

-

... More
7SJ80 (Senstive earth fault/VDOC/50BF/ reverse power protection) (Annexure-F) (Scope- Testing, Periodicity- Yearly)

48

-

-

... More
7SJ64 (BCU,Bay control unit protection132kV)( testing parameters:- Overcurrent, Earth Fault and Bay control Unit protection) (Annexure-G) (Scope- Testing, Periodicity- Yearly)

56

-

-

... More
7SD52 (Line Differential) (testing parameters :- Distance, Differential) (Annexure-H) (Scope- Testing, Periodicity- Yearly)

32

-

-

... More
7UT63 (Transformer Differential) (testing parameters:- Transformer Differential, tank earth fault, Restricted Earth Fault, buchholz,OTI,OSR,PRD Valve) (Annexure-I) (Scope- Testing, Periodicity- Yearly)

32

-

-

... More
7SJ66 (O/C & Earth Fault)(Testing parameters:-over current, under voltage,BCU) (Annexure-J) (Scope- Testing, Periodicity- Yearly)

96

-

-

... More
7SS85 (Bus Bar protection) (Scope- Testing, Periodicity- Yearly)

8

-

-

... More
6MD85 (BCU( LT Side) (Scope- Testing, Periodicity- Yearly)

8

-

-

... More
Relay at incomer side of both RSS

-

-

-

... More
7SD5/87 (Line Differential) (testing parameters:- differential protection) (Annexure-K) (Scope- Testing, Periodicity- Yearly)

16

-

-

... More
**Tentative Performa of Relay testing for Relays mentioned above is attached from Annexure-A to Annexure-K

-

-

-

... More
D-Callibration of following testing kits from NABL accredited laboratory (Scope- Calibration, Periodicity- Yearly)

-

-

-

... More
Meggar (5kV) motwani make

2

-

-

... More
Hi-pot tester for cables upto 220kV level (technology products)

2

-

-

... More
Tan - Delta tester (shivnanda electronics)

2

-

-

... More
Primary injection kit, rated output of 3000A at 3V, 1500A at 6V and 750V at12V , motwani make

2

-

-

... More
Secondary injection kit with a continuously variable voltage of 0-250 VAC (capacity 2A) or 0-500VAC (capacity 1A), motwani make

2

-

-

... More
CT/PT accuracy tester (Udeyraj)

2

-

-

... More
Resonance circuit high voltage test kit (Applied techno products)

2

-

-

... More
Thermal imaging camera (Flir make)

2

-

-

... More
Cable fault detector (telemetrics equipments)

2

-

-

... More
Digital earth resistance meter (motwani make)

2

-

-

... More
Time interval meter (motwani make)

2

-

-

... More
Contact resistance meter (motwani make)

2

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.