New Okhla Industrial Development Authority Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
New Okhla Industrial Development Authority Tender
Civil And Construction
Water Storage And Supply
Eprocure
Opening Date21 Jan 2025
Closing Date3 Feb 2025
Tender Amount₹ 38,06,621
Costs
EMD
₹ 76,200Document Cost
₹ 2,124Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_NOIDA_995980_1Tender No
65/SM(JAL)-II/ET/2024-25Tender Authority
New Okhla Industrial Development Authority ViewPurchaser Address
-Website
http://https://www.noidaauthorityonline.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Capability Statements- File to be downloaded and upload the same file after filling it
BOQ Items
... More
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. The Contractor has to detect different utilities like sewer line, water supply line, electric cable, telephone cable, gas pipe line etc. using utility detecting machine before start of excavation and shall start excavation only after getting permission of Engineer-in-Charge.
1661.78
171
284197.62
... More
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil. The Contractor has to detect different utilities like sewer line, water supply line, electric cable, telephone cable, gas pipe line etc. using utility detecting machine before start of excavation and shall start excavation only after getting permission of Engineer-in-Charge.
638.31
160
102435.99
... More
Providing and laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS : 8329 : 250 mm dia Ductile Iron Class K-7 pipes.
25
4628
115724
... More
300 mm dia Ductile Iron Class K-7 pipes.
35
5914
206998.75
... More
Repairing of Existing PVC water line including bailing out of water by /Manually/Deisel Engine, P/F PVC coupler, CID joint etc. complete work as per direction of E/I (But Excluding cost of Excavation filling and PVC pipe) 200 mm dia.
40
3977
159108
... More
160 mm dia.
45
2938
132214.5
... More
110 mm dia.
30
2165
64971
... More
Supply of PVC pipe 6 Kg/Cm2 Pressure with required PVC standard special confirming to IS : 4985-2000 with latest amendment Make-Finolex Industries Ltd./Kisan/Supreme Industries Ltd. (Rate As Per Comparative Statement per Rm.) 200 mm dia with coupler @ 6 Kgf/Cm2 Pressure.
60
906
54360
... More
160 mm dia with coupler @ 6 Kgf/Cm2 Pressure.
67.5
548
37003.5
... More
110 mm dia with coupler @ 6 Kgf/Cm2 Pressure.
45
257
11565
... More
Repairing existing AC/CI/DI water line i/c all required materials such as CID joints, rubber packing, nut & bolts, bailling out of water, all labour and T&P i/c cutting of pipe etc. complete work as per direction of E/I (But Excluding cost of Excavation filling and M.S. Special.) 200 mm dia.
7
3962
27739.6
... More
250 mm dia.
4
5101
20404.8
... More
300 mm dia.
3
6444
19332.9
... More
P/L following size of Finolex Makes PVC pipes 6 Kg/Cm2 with required PVC standard special confirming to IS codes with latest amendment and lowering the same treches and laying true to alignment and gradient complete i/c the cost of cutting of pipes for making up to length and making joints i/c cost of socket, plstochem PV-85 PVC solvent cement complete. PVC Pipe must be confirmed IS : 4985-2000 with latest amendment. Make- Finolex Industries Ltd./Kisan/Supereme Industries Ltd (Rate as per Comparative Statement per Rm.) a) 110 mm dia with coupler @ 6 Kgf/Cm2 Pressure with i/c all PVC Standard Specials.
95
298
28329
... More
b) 160 mm dia with coupler @ 6 Kgf/Cm2 Pressure with i/c all PVC Standard Specials.
115
611
70276.5
... More
c) 200 mm dia with coupler @ 6 Kgf/Cm2 Pressure with i/c all PVC Standard Specials.
80
996
79688
... More
S/F of M.S. specials such as Tee, Bend, Collars, Tapers, Gap Pieces, including flage ends as required, painting, cutting, welding as per site requirement of MS pipe thickness etc. complete in all respect as per direction of E/I.
18.96
7510
142389.6
... More
P/F Sluice Valve Shall generally conform to IS 14846 with latest amendment, with length over flanges as per PD of IS 14846 corrensponding to BS EN-558/ ISO 5752 Basic Series 3 in CI Construciton having metal seating (IS 318 Gr. LTB 2). with complete Component & Material of construction following below:- 1. Body/Door/Dome -Cast Iron IS 210 Gr. FG 260 2. Spindle- Non rising ; Stainless Steel AISI 410 3. Body Seat/Door Face - Gun Metal : IS 318 Gr. LTB 2 (rings to be press fitted and riveted; no screws allowed) 4. Rivets - Soft annealed brass 5. Spindle Nut - Gun Metal : IS 318 Gr. LTB 2 6. Stem Seal - Greased Hemp 7. Fasteners - Carbon Steel 8. Flange Drilling - IS 1538 Table 4 & 6 9. PN 1.0 10. Accessories (400 mm and above) - Ball thrust bearing to be housed above the wet chamber ie. above the gland. Enclosed Spur Gear Box for ease of operation. Air Plug 11. Painting/Coating - Inside & Outside epoxy liquid coated; DFT minimum 250 micron, shade RAL 5005/5015 (BLUE) 12. Hydro-test - (Open Ended Only) Seat: 10/16 Kg/cm²; Body 15/24 Kg/cm² 13. Upto 600 mm dia Manual Operated & above 600 mm Gear Box Make-Indian Valve Pvt. Ltd. (IVC)/Kirloskar Brothers Limited (KIRLOSKAR) 150 mm dia.
1
24073
24073.6
... More
200 mm dia.
2
42038
84077.8
... More
250 mm dia.
2
54867
109734.4
... More
300 mm dia.
1
78362
78362.6
... More
400 mm dia.
1
164886
164886.4
... More
P/F Reflex Valve upto 600 mm dia shall conform to IS 5312 Part 1 & above to IS 5312 Part-2 with latest amendment, Valves shall be in graded CI with metal to metal (IS 318 Gr. LTB 2) seating, preferably slanted (and not perpendicular) vis-à-vis horizontal axis; SS AISI 410 stub pins & slant seat design with complete Component & Material of construction following below:- 1. Body/Door/Dome - Cast Iron IS 210 Gr. FG 260 2. Hinge pin (single door)/stub pin (multidoor type) - SS AISI 410 3. Seat & Face rings -Gun metal : IS 318 Gr. LTB 2 4. Rivets - Soft annealed brass 5. Fasteners - Carbon Steel 6. Flange Drilling - IS 1538 Table 4 7. PN - 1.0 8. By - pass arrangement - Optional 9. Painting/Coating Inside & Outside epoxy liquid coated : DFT minimum 250 micron, shade RAL 5005/5015 (Blue) 10. Hydro-test Seat : 10/16 Kg/cm2; Body : 15/24 Kg/cm2 MAKE -India Valve Pvt. Ltd. (IVC)/ Kirloskar Brothers Limited (KIRLOSKAR) 150 mm dia Kirloskar MAKE.
1
17018
17018.2
... More
200 mm dia Kirloskar MAKE.
2
28662
57325.2
... More
250 mm dia Kirloskar MAKE.
2
45523
91047.6
... More
300 mm dia Kirloskar MAKE.
1
61284
61284.1
... More
400 mm dia Kirloskar MAKE.
1
138082
138082.8
... More
Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 7.5
5
14501
72505.1
... More
Constructing masonry Chamber 120x120x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 7.5
2
20167
40335.44
... More
Hire Charge of Generator (Including cost Service of operating staff, supply of lubricating oil and diesel also) D.G. Set/Generator 63 KVA
270
748
202041
... More
Hiring of Gas Cutting Set with Oxygen and LPG Running Time @ 6 Hrs.
45
1875
84375
... More
Hiring of Welding Set Running Time @ 6 Hrs.
45
1650
74250
... More
Repairing of sluice valve with the change of spendle (I.e. S.S. non megnated) flapper adjusting nut & bolts & rod & welding machining of body for fitting the flapper properly complete as per direction of E/I. 150 mm dia.
2
2431
4862
... More
200 mm dia.
2
2931
5862
... More
250 mm dia.
2
4829
9658
... More
300 mm dia.
1
6634
6634
... More
400 mm dia.
1
12857
12857.4
... More
Repairing of reflex valve with the change of flapper sheet i/c new lever, rubber sheet, MS ring, S.S.pin shaft & shaft rubber etc. complete. 150 mm dia.
2
3026
6052
... More
b) 200 mm dia.
2
3182
6364
... More
c) 250 mm dia.
2
4778
9556.6
... More
d) 300 mm dia.
1
6378
6378
... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 15 mm nominal outer dia Pipes. 15 mm nominal outer dia Pipes.
138
139
19244.1
... More
Providing and fixing brass ferrule with C.I. mouth cover i/c boring and tapping the main.15 mm dia nominal bore.
115
302
34770.25
... More
Steel work welded in built up sections/ framed work, including hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.
750
108
81720
... More
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 10.0 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand).
4.78
6249
29870.32
... More
12 mm cement plaster finished with a floating coat of neat cement of mix 1:3 (1 Cement : 3 C. Sand).
20.2
267
5401.08
... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size).
15
6781
101719.8
... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources).
22.5
7969
179304.08
... More
Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
638.31
109
70048.14
... More
Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.
63.45
142
9025.76
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%