New Okhla Industrial Development Authority Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
New Okhla Industrial Development Authority Tender
Electrical and Electronics
Eprocure
Opening Date19 Jan 2024
Closing Date1 Feb 2024
Tender Amount₹ 1,32,09,463
Costs
EMD
₹ 2,64,200Document Cost
₹ 5,310Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_NOIDA_882611_1Bid Award Id
ViewTender No
58/DGM(E/M)/SM.(E and M)-III/2023-24Tender Authority
New Okhla Industrial Development Authority ViewPurchaser Address
-Website
http://https://www.noidaauthorityonline.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Supplying and laying of aluminium conductor PVC insulated armoured, served, sheathed cable 1100 Volts grade at a depth of 750 mm. below ground level over a cushion of 75 mm. thick sand alround and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. Clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respects. the armouring of the cable shall be properly connected with the earth conductor by clamps etc. (Polycab, Grandlay, Skytone, Havell's make)
-
-
-
(1) 16 Sq.mm. 4Core (PS No. 501)
8780
3553617
404.74
(2) 50 sq mm 3 ½” core
450
261252
580.56
S/F of cable Lug(socket) to the cable lead. Complete in all respects as per PS No. 504
-
-
-
1- 16 Sq.mm.
2288
56696
24.78
2- 35 Sq.mm.
12
438
36.58
3- 50 Sq.mm.
36
2039
56.64
S/Laying of 90 mm dia (OD 90 mm & ID 76 mm nominal) size of (DWC) HDPE Pipes ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part-II complete with filling and cutting, jointing etc. direct in ground ( 75 cm below ground level) including excavation and refilling the trench pat excluding sand cushioning and protective covering etc. Complete in all respects. Rex/Duraline/ Time/CPE make. as per DSR 2018 item no. 14.16.2 page no. 49
4000
996000
249
Supply and fixing of 25 Amp TPN capacity of automatic street light cubical control panel painted with anti corrosive alkali and acid proof paint crossing of time switch TSO 100 series with contractors, HRC fuse, isolating swtich metering instrument & instrument box with CTs etc. in case of TPN, Complete in all respects. as per PS No. 807E
2
62540
31270
Supplying and fixing of light class G.I. pipe of 80 mm dia. (nominal) 3 metres length along the pole for pro/P+B46-tection of under ground cable as required(DSR-18/12.38/P40
4
9216
2304
Supply of Steel Tubular Pole 11 M long designated 410-SP-56 . complete in all respects as per direction of E/I. .(UPERC P-30)
4
60196
15049
Errection of metallic pole of following length in cement concrete 1:3:6 ( 1cement:3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required above 10.0 mtr and upto 12 mtr (Electrical DSR 2018 I. n. 11.3.4)
4
29304
7326
Supply and erection of overhead line with ACSR Conductor (Dog & Raccoon) poles / service bracket including binding etc. complete in all respects. P.S. No. 627
20
6206
310.34
Painting of the electric pole with 2 Coats of aluminium paint over red oxide primer complete in all respects. P.S. No. 634
4
1529
382.32
Supplying of channel iron 75mmx40mmx6mm(7.14 Kg Per mtr) pole top bracket/cross arm for single 11 kV overhead line conductor complete with 50mmx6mm flat iron clamp, bolts, nuts and washer including drilling holes for insulator pins bolts and nuts etc, and painting with primer and finish paint as required (Electrical DSR-2018 item no. 13.2 pg.44)
2
892
446
S/E of straight MS Channel 50x100 mm. (9.2 Kg/M) 2.60 M long as per design with required clamps made of M.S. flat of size 50x6 mm. with nut & bolts etc. as per direction of E/I. .((UPERC P-30)
14
13426
959
Supplying and erection of 11kV pin insulator complete with large steel head G.I. Pin, nuts & washer etc. as required (DSR-2018 item no. 13.10 pg.46)
12
3372
281
Supplying and erection of 11kV Disc insulator for 11kV overhead line with galvanised inculator fitting, ball and socket type and complete with galvanised strain clamp, bolts, nuts & washer etc. as required (DSR-2018 item no. 13.11 pg.45)
12
11172
931
S/F of 11 KV TPMO Relco/Rama/Azad make 9 Nos. insulator of Jai shree/BHEL/ Rama/ Rastriya make complete in all respects as per direction of E/I.(UPERC page no. 48)
2
36584
18292
S/F of out door type 11KV fuse set Relco/Rama/Rastriya make with insulator Jai shree/BHEL make complete in all respects as per direction of E/I..(AOR)
2
16588
8294
S/E Testing & Commissioning of 63 KVA Al. wound outdoor type Transformer as per ISS. Complete in all respects Make : AZAD/P.M./Kanohar/LD Power/Paramix as per direction of E/I..(RESPO page no. 51)
2
209192
104596
Demolishing cement concrete manually/ by mechanical means including disposal of material with in 50 Mtr. Lead as per direction of E/I. Nominal concrete 1:3:6 or richer mix(i/c equivalent design mix) (DSR civil I No. 15.2.1/P-253)
10
10896
1089.63
Providing and laying in position cement concrete 1:3:6 (1 cement : 2 coarse sand : 6 graded stone aggregate 40 mm nominal size) in foundation of pump, DG set etc including form work etc as required. (DSR Elect. 2018/14.9/48)
5
33070
6614
Supply and burying of 600 mm x 600 mm x 6.0 mm GI plate, vertically for eathing with its top at least 3 meters below ground level complete with 20 mm dia. GI Pipe and funnel for watering and one earthing lead of one no. 8 to 10 SWG GI wire in 15 mm. dia. GI Pipe up to switch board 30 cm. square CI Frame with hinged cover, masonry housing, alternate layers of charcoal/coke and salt at least 150 mm. thick alround etc. as per direction of Engineer-in-charge complete in all respects . PS No. 702
75
473475
6313
Supply and burrying of 75 mm Dia 3 Mtrs. Long Electrode casted with maintenance free, conductive concrete, non corrosive mixture ( Ultra low Resistive carbon 0.001 ohm/Mtr) in the ratio of 3:1:1 (marconite : cement : water) on M.S. Rod with hole (16 mm diameter X3 Mtrs ) will be vertically installed for earthing with 1Mtr G.I strip (25 mm X 2.5mm) connected with SS nut bolt. The earth electrode will be installed into the 100 mm pit up to 3000 mm depth. noraml soil will be used as backfill material. Make : As approved in U.P.P.W.D & C.P.R.I. Certified. (PS no 729(c) P-144)
2
46492
23246
Supply and laying of 25mm x 3mm G.I. strip from earth electrode directly in the ground as required complete in all respect.(PS no 716/ P-138)
200
21240
106.2
Cutting road and making good the same including supply of extra quantities of materials i.e. aggregate, moorum screening, red bajri and labour required (AOR)
-
-
-
a) Bituminous Portion (AOR) (2265.0+18% gst)
15
40090
2672.7
b) Water Bound Macadam (AOR) (1400.0+18% gst)
15
24780
1652
Taking out existing CC interlocking paver blocks form foothpath / Central verge including removel of rubbish etc. disposal of unserviceble material to the dumping ground, For which payment shall be made sepatately and stacking of serviceable meterial within 50 metre lead as per direction fo Engineer-in-Charge D.S.R/S.O.R 16-83
3250
191750
59
Laying old cement cocrete interlocking paver blocks of any design/Shape laid in required line , level curvature, colour and pattern over and including 50 mm thick complete bed of coarse sand, filling the joints with fine sand etc. all comlete as per the direction of Engineerin-Charge.(Old CC paver blocks shall be supplied by the department free of cost).
3250
927875
285.5