New Okhla Industrial Development Authority Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
New Okhla Industrial Development Authority Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date6 Sep 2024
Closing Date19 Sep 2024
Tender Amount₹ 71,44,516
Costs
EMD
₹ 1,42,900Document Cost
₹ 2,832Tender Fee
Refer Documents
Summary
Shifting Of 11 Kv Overhead Line With Lt Transformer At Sector-19, Noida
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_NOIDA_952228_1Tender No
27/DGM(E/M)/S.M(E and M)-II/2024-25Tender Authority
New Okhla Industrial Development Authority ViewPurchaser Address
-Website
http://https://www.noidaauthorityonline.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
S/Making of Straight through joint suitable for 185 sqmm x 3 core 11KV armoured cable as per ISS & Complete in all respects Make: Raychem, Denson, Cabseal. As per direction of E/I. UPERC-2019 P-41
1
10166
10166
Supply and fixing of following type plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer- Incharge. UPPWD-2019 (PS No. 504) -1. 185 Sq.mm.
36
8198
227.74
S/F of Steel Tubular Pole 11 M long designated 410-SP-56 in 1:3:6 Cement, Concrete graded stone aggregate of 40 mm. Nominal size & foundation including excavation back filling etc. complete in all respects as per direction of E/I. (UPERC-2019 Pg-44)
10
150490
15049
S/F of 25x3 mm. G.I. Strip from earth electrode directly in the ground as required complete in all respects as per direction of E/I UPPWD-2018 (PS-716)
100
10620
106.2
Painting of the electric pole with 2 coats of aluminium paint after cleaning of pole. Complete in all respects as per direction of E/I. UPPWD-2018 P.S. No. 634
10
3823
382.32
Supply & erection of overhead line with ACSR conductor on poles / service bracket including binding etc. complete in all respects. UPPWD-2018 PS-627
60
18620
310.34
S/F of straight MS Channel 125x65 mm (13.1 per kg) 175 mtr. Long including packing piece clamp & all nuts and bolts fixing on pole. complete in all respects. As per direction of E/I. (UPERC-2019 P-45)
20
31840
1592
S/F of 11 KV pin 12" long with insulator of Jai Shree/BHEL on cross arm fixed on HT pole including all T/P etc. complete in all respects as per direction of E/I (UPERC-2019) Pg-39
36
7056
196
Providing & Laying of 200 mm dia 6 mm thickness thorugh trenchless method including joints of pipe, excavation of thrust pit and receiving pit of required size, cutting and repairing of road with all T & P and the GPS report submitted by the tendere before excavation & back filling with compaction complete as per specification by H.D.D. machine method. Pipe will be installed at minium depth 2 M to 3M below the ground surface or download as per site condition in required slope.(AOR)
150
902100
6014
Supply and fixing of 150 mm. dia. G.I. Pipe B Class for cable duly clamped with supports by 1 Nos. with clamps of 20x3 mm. M.S. Flat, bolts, nuts and washer required for proper completion or work. UPERC-2019 Page-30
24
35400
1475
S/Laying of Heavy density poly ethylene Pipes ISI marked anti radiant grade OD -160 mm dia PN-8 PE 100 grade as per IS Code 4984 with excavation at the depth of 1.20 mtr below ground level i/c the cost of cutting of pipes for making up to length and making joint complete in all respects. As per direction of E/I. (AOR)
900
831600
924
Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. Complete in all respect as per direction of E/I. Above 10 Mtr and 12 Mtr
DSR-2018(Electrical) 11.3.4
10
73260
7326
Dismantling of pole/ street light standard/ strut embedded in cement concrete foundation etc. as required. Complete in all respect as per direction of E/I. (DSR-2018, 12.42)
10
22210
2221
S/L of Al. armoured cable PVC insulated Ar. served & sheathed cable 1100 V grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. on surface the cable run shall be fixed on M.S. clamps etc of suitable size or as directed by the E/I.Complete in all respects . The armouring of the cable shall be properly connected with the earth conductor by clamps etc. . (PS No. 501) UPSR -2018
-a)- 16 sq. mm 4 core
1800
660564
366.98
b) 50 Sq.mm. 3.5 Core
150
87084
580.56
b)- 400 sq. mm 3.5 core
240
579993
2416.64
S/F of Plain or Pin type copper tin plated cable socket (Lug) to the cable lead, insulating with tape and making connector etc. Complete in all respects as per Direction of E/I (PS No. 504) UPSR-2018 -a)- 16 sq. mm
24
594
24.78
b)- 400 sq. mm
32
22504
703.28
Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 75 to 90 Watt. Confirming to IP 66 and above Protection complete in all respect. E/I. UPPWD-2018 PS No. 1423 Catt-AAA
20
208860
10443
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. DSR-18 (Elect.) Item No-14.16
-a)-63 mm dia (OD-63 mm & ID-51 mm nominal) DSR-18 (Elect.) Item No-14.16.1
80
16720
209
b)-90 mm dia (OD-90 mm & ID-76 mm nominal) DSR-18 (Elect.) Item No-14.16.2
60
14940
249
Supply and burying of 600 mm x 600 mm x 6.0 mm GI plate, vertically for eathing with its top at least 3 meters below ground level complete with 20 mm dia. GI Pipe and funnel for watering and one earthing lead of one no. 8 to 10 SWG GI wire in 12 mm. dia. GI Pipe up to switch board (from appron to switch board the cost of GI pipe and GI wire will be extra) 30 cm. square GI Frame with hinged cover, masonry housing, alternate layers of charcoal/coke and salt at least 150 mm. thick alround etc. as per direction of Engineer-in-charge complete in all respects (This will apply for earthing of poles also). UPPWD-2018, PS-702
2
12626
6313
Supply and burring of Safe Earthing Electrode T-19, (Hot Dip Galvanized), Length up to 3000mm, outer Dia 50 mm inner Dia 25 mm, terminal Dia 12mm, outer GI pipe of 16 swg and inner GI pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity and one earthing lead of 25mm x 3mm G.I. strip, upto switch board (from apron to switch board, the cost of G.I. strip will be extra) along with 30
cm square C.I. frame with hinged cover & masonry housing. Make: As approved in U.P. P.W.D., & C.P.R.I. Certified.. as per direction of Engineer-in-charge complete in all respects (This will apply for earthing of poles also). UPPWD-2018, PS-725B
10
118472
11847.2
Supplying and embedding following dia G.I. pipe 32 mm dia (medium class) in pole collar/ foundation (during casting) for cable entry including bending the pipe to the required shape complete as required. DSR-2018, 11.6.1
48
15552
324
S/E of straight MS Channel 50x100 mm. (9.2 Kg/M) 2.24 M long as per design with required clamps made of M.S. flat of size 50x6 mm. with nut & bolts etc. as per direction of E/I. UPERC-2019 P-24
10
8260
826
S/F of 11 KV TPMO Relco/Rama make 9 Nos. insulator of Jai shree/BHEL/Rama/ Rastriya make complete in all respects as per direction of E/I UPERC-2019 Page No-48
4
73168
18292
S/F of out door type 11KV fuse set with insulator Jai shree/ BHEL make complete in all respects as per direction of E/I. Relco/ Rama/Rastriya /UPPCL approved make (AOR)
4
31488
7872
S/F of 11 KV Disc insulator 70 KN or 7000 Kg. and fitting B&S heavy duty with clamp of cross arm fixed on HT Pole.UPERC-2019 Page no-48
36
6012
167
Cement concrete with 4 cm gauge approved stone ballast coarse sand & cement in the proportion of 8:4:1 including supply of all materials, labour, Tools & Plants etc. Required for proper completion of the work. (SOR)
13
89278
6867.6
Excavation in foundation in ordinary soil (Loam, clay or sandy) including lift upto 1.50 M and lead upto 30 M. And including filling watering and ramming of excavated earth into the tenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the E/I upto a distance of 30 M. from the foundation trenches (Where machine con not reach/move) For Building work only as in item 251A P.W.D. (SOR)
170
19057
112.1
Laying old Cement concrete interlocking paver blocks of any design/shape laid in required line, level, curvature, colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. All complete as per the direction of engineer (AOR)
800
228400
285.5
Taking out existing CC interlocking from footpath/central verge, including removal of rubbish etc, disposal of unserviceable material to the dumping ground, for wich payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of E/I. (AOR)
800
47200
59
Providing and fixing of M.S. Special such as Tee, Bends, collars, Tapers, Gap pieces including Flange ends as required, painting, cutting, welding as per site requirement of MS pipe thickness etc. complete in all respect as per direction of E/I. (AOR)
1500
112650
75.1
Cement concrete with 4 cm gauge approved stone ballast coarse sand & cement in the proportion of 8:4:1 including supply of all materials, labour, Tools & Plants etc. Required for proper completion of the work. (SOR)
7.5
51507
6867.6
M.S. Strip (50x6mm ) Fencing (6 Feet Height including Civil work) as per direction of E/I. (UPER-2019) pg-53
48
117600
2450
FRP Fencing (6 Feet Height including Civil work) as per direction of E/I. (UPER-2019) pg-53
48
115200
2400
Supply & erection of "D" clamps of 50 mm x 6mm flat iron on steel tubular poles / steel rail poles with bolts, nuts etc. complete in all respects including painting with aluminium paintUPPWD-2018, PS-623
60
15788
263.14
Supply of Danger Borad with Clamp UPERC-2019 Page No-45
20
9220
461
Evaluation Notes How It Works ?