New Okhla Industrial Development Authority Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

New Okhla Industrial Development Authority Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date19 Jan 2024
Closing Date25 Jan 2024
Tender Amount₹ 1,46,46,665 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
the Luminaire only. The rated voltage of the Luminaire should be 230Vac, Luminaire shall be offered with a BIS Approved Potted Driver of IP 66/67 rating made of extruded aluminium to make it more thermal efficient, Led Driver should have Operating input voltage range: 90-305VAC, PF 0.90 and must have safety operation range form 90V - 176Vac. Life time of LED driver should be 80,000 hours and MTBF of LED driver should be ≥ 2,00,000 hrs, Led driver must have SELV output and Case temperature i.e. Tc 90°C. Fixture shall be suitable to operate at an ambient temperature range of -30°C to 50°C and complete luminaire shall be IP66 and IK07 rated. LED Life time shall be at least L70B50 @ 70000 burning hours at 50°C. LED should be with ceramic package of make Nichea, Osram, Cree, Lumiled only. The product should be BIS approved with R number mentioned on product label. To be supported with Product test reports - LM79, BIS Report and LEDs Test Reports. Luminaire shall be conforming to BIS i.e. IS 10322 (Part 5/Sec 5) and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required.with 5 years warranty AOR

40

1215880

30397

... More
Supply, Installation, Testing and Commissioning of exterior BIS registered LED RGBW flood lighting luminaire for facade lighting with Die-cast aluminium housing, powder-coated finish, Clear toughened glass of 4mm thickness, of Total System wattage not exceeding 45W with system lumen output 2379 lm with all LEDs on , minimum system lumen efficacy 55 lm/w. Luminaire shall be capable of producing dynamic color changing light with 16 million colors as the light fixture should be programmable using 8 bit control DMX512 protocol / Ethernet based control. Luminaire should be complete with dedicated Lens made up of UL/VDE approved PC for each LED, offering beam angle of different types such as narrow, medium, wide or elliptical as per the site requirement. Fixture should have Height 276 mm±5% including surface mount base width 183 mm±5% , length 320 mm ±5% with constant locking hinges for simple position control from various angles without special tools.Fixture shall be suitable to operate at an ambient

-

-

-

... More
temperature range of -30°C to 50°C and complete luminaire shall be IP66 and IK07 rated. LED Life time shall be at least L70B50 @ 70000 burning hours at 50°C. LED should be with ceramic package of make Nichea, Osram, Cree, Lumiled only. DMX enabler circuit should be inside the Luminaire only. DMX enabler circuit should be inside the Luminaire only. Luminaire shall be complete with integrated BIS IP 66/67 potted driver and capable of operating at line voltage from 90-305 Vac, 50Hz with power factor 0.9. The product should be BIS approved with R number mentioned on product label. To be supported with Product test reports - LM79, BIS Report and LEDs Test Reports.Luminaire shall be conforming to BIS i.e. IS 10322 (Part 5/Sec 5) and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required.with 5 years warranty AOR

30

1035540

34518

... More
Supply, Installation, Testing and Commissioning of exterior BIS registered LED RGB flood lighting luminaire for facade lighting with Die-cast aluminium housing, powder-coated finish, Clear toughened glass of 4mm thickness, of Total System wattage not exceeding 28W with system lumen output 1641 lm with all LEDs on , minimum system lumen efficacy 58lm/w. Luminaire shall be capable of producing dynamic color changing light with 16 million colors as the light fixture should be programmable using 8 bit control DMX512 protocol / Ethernet based control. Luminaire should be complete with dedicated Lens made up of UL/VDE approved PC for each LED, offering beam angle of different types such as narrow, medium, wide or elliptical as per the site requirement. Fixture should have Height 208 mm±1% including surface mount base and outer dia of 224 mm±1% with constant locking hinges for simple position control from various angles without special tools. Fixture shall be suitable to operate at an ambient temperature range of -30°C to 50°C and complete luminaire shall be IP66 and IK07 rated.

-

-

-

... More
LED Life time shall be at least L70B50 @ 70000 burning hours at 50°C. LED should be with ceramic package of make Nichea, Osram, Cree, Lumiled only. DMX enabler circuit should be inside the Luminaire only. DMX enabler circuit should be inside the Luminaire only. Luminaire shall be complete with integrated BIS IP 66/67 potted driver and capable of operating at line voltage from 90-305 Vac, 50Hz with power factor 0.9. The product should be BIS approved with R number mentioned on product label. To be supported with Product test reports - LM79, BIS Report and LEDs Test Reports. Luminaire shall be conforming to BIS i.e. IS 10322 (Part 5/Sec 5) and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required.with 5 years of warranty

30

658560

21952

... More
Supply, Installation,Testing and Commisioning of exterior BIS registered RGBW Flexible LED Strip with 14.4 Watt per meter. LED Strip should have 60Nos LEDs per meter through out the length with the silicon cover with system lumens 708 lms/meter and System Lumen Efficacy 49lm/w. Standard Length of LED Strip is 5 mtr and it shall be capable of producing dynamic color changing light for with 16 million colors and should be programmable using 8 bit control DMX512 protocol / Ethernet based control. The Strip should have IP 67 protection with inbuilt IP67 connectors at both ends. DMX enabler circuit should be outside the Luminaire/LED Strip only. LED Strip shall be suitable to operate at an ambient temperature range of -20°C to 50°C. Life time shall be at least L70B50 @ 35000 burning hours at 50°C. LED should of make Nichea, Osram, Cree, Lumiled, Hongya of 5050 SMD package only. The rated voltage of the Luminaire should be 24VDC, Luminaire shall be offered with a BIS Approved Potted Driver of IP 66/67 rating made of extruded aluminium to make it more thermal efficient,

-

-

-

... More
Led Driver should have Operating input voltage range: 90-305Vac, PF 0.95 and must have safety operation range form 90V - 176Vac. Life time of LED driver should be 80,000 hours and MTBF of LED driver should be ≥ 2,00,000 hrs, Led driver must have SELV output and Case temperature i.e. Tc 90°C. The product should be BIS approved with R number mentioned on product label. To be supported with Product test reports - LM79, BIS Report and LEDs Test Reports. Luminaire shall be conforming to BIS i.e. IS 10322 (PART 5/SEC 7) and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required.with 5 Years of warranty

615

3271800

5320

... More
Supply,Installation, Testing and commisioning of DMX Controller for the system including all other accessories required for the running of the system Controller should have Input Power 5-5.5V DC 0.6A and Output Protocol DMX512 with 4 universe, 2 universe should work in Stand Alone Mode and 2 universe should work in live mode with laptop/ tablet / computer. The universe should be expandable from 2 to 4 DMX512 universes. It should be compatible for Programmability with PC, Mac, Tablet, Smartphone by using USB & Ethernet .Dmx controller should have network controllability feature to control the scene remotely through LAN and triggered via UDP packets on port 2430. Its must have Connections Type C USB, XLR3, Ethernet, battery. There should be provision for Memory microSD card. Device should have Intuitive backlit keyboard with 10 presets and also have provision of kepad on device for changing scene manually from device. Device should be capable to work on Extended triggering possibilities (TCA) & also have Smart Upgrade Technology (SUT).

-

-

-

... More
It is an IP 20 unit and has an Operating Temperature of 0°C to 50°C. weight should not be more than 120g. OS Requirements for the controller is Mac OS X 10.8-10.12, Windows 7/8/10. Standards should be EC, EMC, ROHS. The controller should have a variety of features including 2048 DMX channels, clock/calendar, iPhone/iPad/Android remote control, Ethernet facilities, dry contact port triggering and multi-zone SD card memory. Network synchronization of one area across hundreds of universes with the possibility of 99 scenes across 5 areas with auto clock triggering for sunrise and sunset and as per the festivals for specific occasions. Device should be equipped with meta; clamp to mount on wall. All Dynamic LED lighting fixtures & controllers shall be of same make to avoid integration, synchronization, and maintenance issues in future. To be provided with IP 66 enclosure if installed in external environment.with 5 Years warranty AOR

1

140000

140000

... More
Supply ,Installation, Testing and Commissioning of Signal Amplifier to boost the Signal, IP 65 rated module to enahce the depleting DMX Signals, should have IP 66/67 rates inbuilt connectors compatible with Luminaires. It should be offered with inbuilt electronic ciruit for functioning. No external LED driver needed.

6

100800

16800

... More
Supply,Installation,Testing and Commisioning of DMX Splitter with Input Voltage range : 190-240V AC, Power Consumption 5W max. Housing is made of CRCA with powder coated finish Mounting, 19 inch rack mountable, Operation Temperature -30°C to +55°C, 8 Output with 3pin XLR terminal sockets, Ingress Protection Rating IP20. This unit takes the DMX Signal from DMX Controller & split the signal into 8 separate output channels. The output terminals of Splitters are optically isolated from the input. Splitters should be capable to amplify the DMX signal & allowing the data link to be extended by max. 300 m (1044 ft.) using AWG 22 DMX cable or 150 m (500 ft.) using AWG 24 DMX cable or maximum 20-25 fixture per output channel. To be provided with IP enclosure if installed in external environment.AOR

2

84000

42000

... More
Supply installation testing and Commissioning of DMX Wire 2Core 0.75 mm Shielded cable Network wiring consists of a shielded twisted pair, with a characteristic impedance of 120 ohms, with a termination resist or at the end of the cable farthest from the controller to absorb signal reflections with 5 Years Warranty. AOR

800

201600

252

... More
Programmingof the entire job with desired themes as per the engineer in charge with 5 Years Warranty. AOR

1

280000

280000

... More
Supply, Installation, testing & Commissioning of flexible copper power cable 3 x 2.5 sqmm with 5 Years Warranty. AOR

1200

201600

168

... More
Supply and fixing following capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contactors, HRC fuses, isolating switch metering instrument & instrument box wi th CTs etc. in case of TPN, complete in all respect. Ps.No.807 i) 15 A SPN

2

40592

20296

... More
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required..DSR.2018 1.20.2

900

148500

165

... More
Supply and burring of Safe Earthing Electrode T-19 (Hot Dip Galvanized), Length up to 2000mm, outer pipe 50mm, inner pipe 25, terminal Dia 12 mm, outer GI pipe of 16 swg and inner GI pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30cm square C.I. frame with hinged cover & masonry husing (from electrode terminal to switch board, cost of 25 x 3 G.I . strip will be extra) Make: As approved in U.P. P.W.D., & C.P.R.I. Certified.(P.S. No 725A)

8

60888

7611

... More
S/Laying of 90 mm dia (OD 90 mm & ID 76 mm nominal) size of (DWC) HDPE Pipes ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part-II complete with filling and cutting, jointing etc. direct in ground ( 75 cm below ground level) including excavation and refilling the trench pat excluding sand cushioning and protective covering etc. Complete in all respects. Rex/Duraline/ Time/CPE make. as per DSR 2018 item no. 14.16.2 page no. 49

30

7470

249

... More
Supplying and embedding following dia G.I. pipe (medium class) in pole collar/ foundation (during casting) for cable entry including bending the pipe to the required shape complete as required. DSR - 2018 11.6.2 i) 40mm

110

40480

368

... More
Supplying and fixing of WPC panel 11 mm thick with laser cutting of design as directed by engineer in charge , cost including fixing of pannels with required accessories, nuts, bolts ,channels , scews, scaffoldings fastners as required to complete the work AOR

515

3989808

7747.2

... More
Providing & Fixing Polycarbonate sheet with 10 mm thickness of approved colour, shade and texture and fixed with approved adhesive as per manufacture sepcifications. The adhesive used for laying the sheet shall be as per the written recommendation made by the manufacturer with written approval on shade as per direction of Engineer-in-charge AOR

652

1407159

2158.22

... More
finishing wall with acrylic smooth exterior paint of fequired shade . New work two coat or more applied @1.67 lt/ 10 sqm over and including priming coat of exterior primer applied @2.20 kg / 10 sqm AOR

2410.1

335155

139.06

... More
Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineerin-charge .The elevational area of the scaffolding shall be measured for payment purpose .The payment will be made once irrespective of duration of scaffolding. This item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to be done. AOR

510

91214

178.85

... More
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works AOR

7850.73

855424

108.96



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.