New Okhla Industrial Development Authority Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

New Okhla Industrial Development Authority Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date26 Nov 2024
Closing Date9 Dec 2024
Tender Amount₹ 99,98,276 
Notes
Download

Costs

Summary

Strengthening Of Cables And Street Light At Sector-70, 121, 123,noida

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Taking out existing CC interlocking from footpath/central verge, including removal of rubbish etc, disposal of unserviceable material to the dumping ground, for wich payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of E/I. (AOR)

1250

59

73750

... More
S/F of 25x3 mm. G.I. Strip from earth electrode directly in the ground as required complete in all respects as per direction of E/I UPPWD-2018 (PS-716)

40

106

4248

... More
Painting of the electric pole with 2 coats of aluminium paint after cleaning of pole. Complete in all respects as per direction of E/I. UPPWD-2018 P.S. No. 634

4

382

1529.28

... More
Supply & erection of overhead line with ACSR conductor on poles / service bracket including binding etc. complete in all respects. UPPWD-2018 PS-627

20

310

6206.8

... More
S/F of straight MS Channel 125x65 mm (13.1 per kg) 175 mtr. Long including packing piece clamp & all nuts and bolts fixing on pole. complete in all respects. As per direction of E/I. (UPERC-2019 P-45)

10

1592

15920

... More
S/F of 11 KV pin 12" long with insulator of Jai Shree/BHEL on cross arm fixed on HT pole including all T/P etc. complete in all respects as per direction of E/I (UPERC-2019) Pg-39

18

196

3528

... More
S/L of Al. armoured cable PVC insulated Ar. served & sheathed cable 1100 V grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. on surface the cable run shall be fixed on M.S. clamps etc of suitable size or as directed by the E/I.Complete in all respects . The armouring of the cable shall be properly connected with the earth conductor by clamps etc. (PS No. 501) UPSR -2018 a)- 10 sq. mm 2 core

2450

344

844172

... More
b)- 16 sq. mm 2 core

6800

366

2495464

... More
c)- 16 sq. mm 4 core

3515

404

1422661.1

... More
d)- 50 sq. mm 3.5 core

860

580

499281.6

... More
S/F of Plain or Pin type copper tin plated cable socket (Lug) to the cable lead, insulating with tape and making connector etc. Complete in all respects as per Direction of E/I (PS No. 504) UPSR-2018 a)-10 sq. mm

400

23

9440

... More
b)-16 sq. mm

440

24

10903.2

... More
c)- 50 sq. mm

24

56

1359.36

... More
Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 75 to 90 Watt. Confirming to IP 66 and above Protection complete in all respect. E/I. UPPWD-2018 PS No. 1423 Catt-AAA

80

10443

835440

... More
Supply and fixing Following automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contactors, HRC fuses, isolating switch metering instrument & instrument box with CTs etc. in case of TPN, UPPWD-2018, PS-807 1. 40 AMP SPN

6

22656

135936

... More
2. 40 AMP TPN

8

34574

276592

... More
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. DSR-18 (Elect.) Item No-14.16 -a)-63 mm dia (OD-63 mm & ID-51 mm nominal) DSR-18 (Elect.) Item No-14.16.1

6500

209

1358500

... More
b)-90 mm dia (OD-90 mm & ID-76 mm nominal) DSR-18 (Elect.) Item No-14.16.2

36

249

8964

... More
Supply and burying of 600 mm x 600 mm x 6.0 mm GI plate, vertically for eathing with its top at least 3 meters below ground level complete with 20 mm dia. GI Pipe and funnel for watering and one earthing lead of one no. 8 to 10 SWG GI wire in 12 mm. dia. GI Pipe up to switch board (from appron to switch board the cost of GI pipe and GI wire will be extra) 30 cm. square GI Frame with hinged cover, masonry housing, alternate layers of charcoal/coke and salt at least 150 mm. thick alround etc. as per direction of Engineer-in-charge complete in all respects (This will apply for earthing of poles also). UPPWD-2018, PS-702

12

6313

75756

... More
Supplying and embedding following dia G.I. pipe 32 mm dia (medium class) in pole collar/ foundation (during casting) for cable entry including bending the pipe to the required shape complete as required. DSR-2018, 11.6.1

12

324

3888

... More
S/E of straight MS Channel 50x100 mm. (9.2 Kg/M) 2.24 M long as per design with required clamps made of M.S. flat of size 50x6 mm. with nut & bolts etc. as per direction of E/I. UPERC-2019 P-24

10

826

8260

... More
S/F of 11 KV TPMO Relco/Rama make 9 Nos. insulator of Jai shree/BHEL/Rama/ Rastriya make complete in all respects as per direction of E/I UPERC-2019 Page No-48

2

18292

36584

... More
S/F of out door type 11KV fuse set with insulator Jai shree/ BHEL make complete in all respects as per direction of E/I. Relco/ Rama/Rastriya /UPPCL approved make (AOR)

2

7872

15744

... More
S/F of 11 KV Disc insulator 70 KN or 7000 Kg. and fitting B&S heavy duty with clamp of cross arm fixed on HT Pole.UPERC-2019 Page no-48

18

167

3006

... More
M.S. Strip (50x6mm ) Fencing (6 Feet Height including Civil work) as per direction of E/I. (UPER-2019) pg-53

16

2450

39200

... More
FRP Fencing (6 Feet Height including Civil work) as per direction of E/I. (UPER-2019) pg-53

16

2400

38400

... More
Excavation in foundation in ordinary soil (Loam, clay or sandy) including lift upto 1.50 M and lead upto 30 M. And including filling watering and ramming of excavated earth into the tenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the E/I upto a distance of 30 M. from the foundation trenches (Where machine con not reach/move) For Building work only as in item 251A P.W.D. (SOR)

60

112

6726

... More
S/E testing & commissioning of 100 KVA copper wound outdoor type distribution transformer as per ISS : including inspection fees etc. complete in all respect Make: Crompton/Alstom/ABB/ Schneider as per direction of E/I. (UPER-2019) pg-51

2

136710

273420



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.