New Okhla Industrial Development Authority Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
New Okhla Industrial Development Authority Tender
Housekeeping Services
Electrical and Electronics
Eprocure
Opening Date12 Jan 2024
Closing DateCancelled
Tender Amount₹ 17,86,452
Costs
EMD
₹ 35,800Document Cost
₹ 1,416Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_NOIDA_879790_1Tender No
39/DGM(E/M)/S M.(E and M)-IV/2023-24Tender Authority
New Okhla Industrial Development Authority ViewPurchaser Address
-Website
http://https://www.noidaauthorityonline.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Repairing of 11KV Fuse wire/Jumper i/c supply & fixing of required size conductor, fuse wires of 11KV Line/DP Structure of Transformer by taking shutdown from UPPCL Department with all safety instruments like-safety belt, Gloves, Shoes and other necessary items. (AOR)
20
57100
2855
Dismantling of pole/ street light standard/ strut embedded in cement concrete foundation etc. as required. DSR-2018. 12.42
5
11105
2221
Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required.. DSR-2018, 11.3.1 Above 4.5 metre and upto 6.5 metre
5
22460
4492
Supply and burring of Safe Earthing Electrode T-19, (Hot Dip Galvanized), Length up to 3000mm, outer Dia 50 mm inner Dia 25 mm, terminal Dia 12mm, outer GI pipe of 16 swg and inner GI pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity and one earthing lead of 25mm x 3mm G.I. strip, upto switch board (from apron to switch board, the cost of G.I. strip will be extra) along with 30 cm square C.I. frame with hinged cover & masonry housing. Make: As approved in U.P. P.W.D., & C.P.R.I. Certified. UPPWD-2018, PS 725B
1
11847
11847.2
S/L of Al. armoured cable PVC insulated Ar. served & sheathed cable 1100 V grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. on surface the cable run shall be fixed on M.S. clamps etc of suitable size or as directed by the E/I.Complete in all respects . The armouring of the cable shall be properly connected with the earth conductor by clamps etc. Make -KEI/Diatron/Gloster/Universal/Polycab/Havells. (PS No. 501) UPSR -2018 a)- 16 sq. mm 2 core
800
293584
366.98
c)- 50 sq. mm 3.5 core
400
232224
580.56
S/F of Plain or Pin type copper tin plated cable socket (Lug) to the cable lead, insulating with tape and making connector etc. Complete in all respects as per Direction of E/I (PS No. 504) UPSR-2018 a)- 16 sq. mm
150
3717
24.78
c)- 50 sq. mm
18
1019
56.64
Supply and laying of 25mm x 3mm G.I. strip from earth electrode directly in the ground as required complete in all respect., PS No. 716
5
531
106.2
S/F of 11 KV TPMO 9 Nos. insulator of complete in all respects as per direction of E/I UPERC Pg. No-48
2
36584
18292
S/F of out door type 11KV fuse set with insulator. complete in all respects as per direction of E/I AOR
2
16588
8294
Supplying and erection of 11 KV pin insulator complete with large steel head G.I. pin, nuts, washers etc. as required. DSR-2018, 13.10
9
2529
281
Supplying and erection of 11 KV disc insulator for 11 KV over head lines with galvanised insulator fittings, ball and socket type and complete with galvanised strain clamps, bolts, nuts, washers etc. as required.DSR-2018, 13.11
9
8379
931
Supply & fixing of 6 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 130mm and base plate 12mm thik) having 3mm thikness with Single arm bracket 1 Mtr length in 1:2:4 RCC foundation bolt including the cost of foundation, excavation & back filling and Required T&P completee in all respect. PS No.647
2
34810
17405
S/F of Sintex SMC Junction box model no. GSIB-2817 size 240x130x110 mm with porceline Kit-kat & Al. Bus-bar hinged nut for cable connection etc. as per direction of E/I. (AOR)
15
23145
1543
Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required DSR-2018, 12.34
10
10120
1012
Fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 52 watt to 72 Watt. Confirming to IP66 Protection complete in all respect.. PS No.1422
15
2885
192.34
Supply and fixing of Pole Bus Bar Support Connector 3 Way With Backsheet complete in all respect as per direction of the Engineer-Incharge. AOR
20
2260
113
Repairing of transformer 63 KVA with replaced HV LV coil,, Bushing, Gasket Set, injection Material, Fresh transformer oil savita make & painting etc. Complete in all respects.
2
84700
42350
Dis./Re-fixing of 25/63/100 KVA with replaced loading & uploading, cartage charge frome site to repairing at workshop complete in all respects as per direction of E/I.
2
8800
4400
Rewinding & repairing of 400 KVA transformer as per orignal winding 11/433 k volt with super cnamelled copper wire as required gauge complete in all respects as per direction of eE/I. it is also incl. the dismentling/refixing/cartage from site workshop/factory and vice xersa. the old material with property of contractor (old material rate already deducted in. (AOR)
1
193483
193483
Rewinding & repairing of 250 KVA transformer as per orignal winding 11/433 k volt with super cnamelled copper wire as required gauge complete in all respects as per direction of eE/I. it is also incl. the dismentling/refixing/cartage from site workshop/factory and vice xersa. the old material with property of contractor (old material rate already deducted in. (AOR)
2
310888
155444
Supply of 185 sq. mm 3 core high conductivity aluminum strand compacted circular conductor XLPE armoured 11 KV(E) Cable neutral earthed system confirming to IS 7098-Part-II (1985) with latest amendment complete in all respects as per direction of E/I. Make: Gloster/ Universal/KEI/ Diatron/ Havells . (UPERC P-28)
10
8910
891
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required..(DSR elect 2018 Item.N. 8.3.2 Above 120 Sqmm and upto 400 Sqmm
10
1120
112
Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :DSR 2018 10.5.3 I) 240 Sq.MM
1
17166
17166
Supplying and making straight through cable jointing with heat shrinkable jointing kit complete with all accessories including ferrules suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required : DSR 2018. 10.6.3 I) 240 Sq.MM
2
38628
19314
Supply of 2.5 sqmm 3 core copper conductor XLPE cable at site as per direction of E/I. (AOR)
270
22680
84
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.63 mm dia (OD-63 mm & ID-51 mm nominal) DSR-Electrical-2018, 14.16.1
100
20900
209
Supply and fixing of 40 A TPN of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contactors, HRC fuses, isolating switch metering instrument & instrument box with CTs etc. in case of TPN, complete in all respect. UPPWD-2018, PS-807 (F)-II
1
34574
34574
Supply & erection of overhead line with ACSR conductor on poles / service bracket including binding etc. complete in all respects. PS No-627
10
3103
310.34
Supplying and making straight through joint with cast resin compound including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required DSR-2018 9.3.1 a) 2 X 16 sq. mm
25
64825
2593
b) 2 X 25 sq. mm DSR-2018, 9.3.2
5
12965
2593
c)3½ X 50 sq. mm DSR-2018, 9.3.19
2
6924
3462
d)3½ X 70 sq. mm sq. mm DSR-2018, 9.3.20
2
6984
3492
Providing and fixing of G.I. Chain Link fabric fencing of required width size50x50mm including strengthening with 2mm dia wire or nuts, bolts and washers as required Complete as per the direction of Engineer-in-charge. Made of G.I. Wire of dia 4mm PVC Coated to achieve outer dia not less 5mm in required colour and shade. Complete in all respect as per direction of E/I.(AOR)
12
8635
719.62
Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. (AOR) 10.25.2(AOR)
200
23640
118.2
12 mm cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement. (AOR) 13.9.1
5
1336
267.38
Brick work with F.P.S. bricks of class designation 100 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand) (AOR) 6.1.1
0.5
3076
6153.46
Cement Concrete with 2 cm gauge approved stone ballast, coarse sand & cement in the proportion of 4:2:1 including supply of all mlaterials, labour, tools & plants etc. required for proper completion of the work. SOR 5.07 Schedule Item no. 279 (a)
0.5
4130
8260
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements