New Okhla Industrial Development Authority Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
New Okhla Industrial Development Authority Tender
Civil And Construction
Eprocure
Opening Date20 Sep 2024
Closing Date26 Sep 2024
Tender AmountRefer Documents
Costs
EMD
₹ 1,24,700Document Cost
₹ 2,832Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_NOIDA_954283_1Bid Award Id
ViewTender No
22/SM (JAL)-I/ET/2024-25Tender Authority
New Okhla Industrial Development Authority ViewPurchaser Address
-Website
http://https://www.noidaauthorityonline.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
Repairing existing AC/CI/DI water line i/c all required materials such as CID joints, rubber packing, nut & bolts, bailling out of water, all labour and T&P i/c cutting of pipe etc. complete work as per direction of E/I. (But exluciding cost of Excavation filling and M.S. Special) 4.01) 200 mm dia C.I.
13
3962
51516.4
... More
250 mm dia C.I.
13
5101
66315.6
... More
300 mm dia C.I.
14
6444
90220.2
... More
350 mm dia C.I.
11
8047
88523.6
... More
400 mm dia C.I.
12
10085
121029.6
... More
Repairing of Existing PVC water line bailing out of water by / Beldar / Deisel Engine, P/F PVC coupler, CID joint etc. complete work as per direction of E/I (But Excluding cost of Excavation filling) 5.01) 90 mm dia
65
2027
131768
... More
110 mm dia
55
2165
119113.5
... More
140 mm dia
25
2662
66555
... More
160 mm dia
18
2938
52885.8
... More
200 mm dia
16
3977
63643.2
... More
250 mm dia
11
5357
58934.7
... More
P/L following size of Finolex makes PVC pipes 6 Kg/Cm2 with required PVC standard special confirming to IS codes with latest amendment and lowering the same trenches and laying true to alignment and gradient complete i/c the cost of cutting of pipes for making up to length and making joints i/c cost of socket, plstochem PV-85 pvc solvent cement complete. PVC pipe must be confirming to IS:4985-2000 with latest amendment. Make-Finolex Industries Ltd./Kisan/Superme Industries Ltd. (Rate As per Comparative Statement Per. Rm.) 6.01) 90 mm dia with coupler @ 6 Kg/Cm2 Pressure with i/c all PVC standard Specials
123.5
209
25823.85
... More
110 mm dia with coupler @ 6 Kg/Cm2 Pressure with i/c all PVC standard Specials
110
298
32802
... More
140 mm dia with coupler @ 6 Kg/Cm2 Pressure with i/c all PVC standard Specials
52.5
492
25877.25
... More
160 mm dia with coupler @ 6 Kg/Cm2 Pressure with i/c all PVC standard Specials
39.6
611
24199.56
... More
200 mm dia with coupler @ 6 Kg/Cm2 Pressure with i/c all PVC standard Specials
40
996
39844
... More
250 mm dia with coupler @ 6 Kg/Cm2 Pressure with i/c all PVC standard Specials
27.5
1530
42080.5
... More
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth consolidating each deposited layer by ramming & watering, lead upto 50 m and lift upto 1.5 m.
2337.21
109
256485.43
... More
P/F M.S. specials such as Tee, Bend, Collars, Tapers, Gap pieces, including Flange Ends as required, Painting, Cutting, welding as per site requirement of MS pipe thickness etc complete in all respect as per direction of E/I.
15793.73
75
1186109.12
... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
54.94
6781
372565.72
... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : "1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size).
54.94
7969
437820.71
... More
P/F Sluice Valve shall generally conform to IS 14846 with latest amendment, with length over flanged as per PD of IS 14846 corresponding to BS EN-558 / ISO 5752 Basic series 3 in CI construction having metal seating (IS 318 Gr. LTB 2). With comple component & material of construction following below:-
1 - Body / Door / Dome - Cast Iron IS 210 Gr. FC 260
2 - Spindle - Non rising: Stainless Steel AISI 410
3 - Body seat / Door face - Gun metal : IS 318 Gr. LTB 2 (rings to be press fitted and riveted: no screws allowed)
4 - Rivets - Soft annealed brass
5 - Spindle Nut - Gun metal : IS 318 Gr. LTB 2
6 - Stem Seal - Greased Hemp
7 - Fasteners - Carbon steel
8 - Flange Drilling - IS 1538 Table 4 & 6
9 - PN 1.0
10 - Accessories (400 mm and above) - Ball thrust bearings to be housed above the wet chamber ie. above the gland. Enclosed Spur Gear Box for ease of operation. Air Plug
11 - Painting / Coating - Inside & Outside epoxy liquid coated; DFT minimum 250 micron, shade RAL 5005 / 5015 (BLUE)
12 - Hydro-test-(Open Ended only) (Seat : 10/16 Kg/cm2; Body: 15 / 24 Kg/cm2
13 - Upto 600mm dia Mannual Operated & above 600mm Gear box
Make-Indian Valve Pvt. Ltd. (IVC) / Kirloskar Brothers Limited KIRLOSKAR) 11.01) 150 mm dia
1
24073
24073.6
... More
200 mm dia
1
42038
42038.9
... More
250 mm dia
1
54867
54867.2
... More
300 mm dia
1
78362
78362.6
... More
350 mm dia
1
129265
129265.2
... More
400 mm dia
1
164886
164886.4
... More
P/F Reflex Valve upto 600mm dia shall conform to IS 5312 Part-1 & above to IS 5312 Part-2 with latest amendment, Valves shall be in graded CI with metal to metal (IS 318 Gr. LTB 2) seating, preferably slanted (and not perpendicular) vis-a-vis horizontal axis; SS AISI 410 stub pins & slant seat design. with comple component & material of construction following below:-
1 - Body / Door / Dome - Cast Iron IS 210 Gr. FC 260
2 - Hinge pin (single door) / Stub pin (multidoor type) - SS AISI 410
3 - Seat & Face rings - Gun metal : IS 318 Gr. LTB 2 4 - Rivets - Soft annealed brass
5 - Fasteners - Carbon steel
6 - Flange Drilling - IS 1538 Table 4 & 6
7 - PN 1.0
8 - By - pass arrangement - Optional
9 - Painting / Coating - Inside & Outside epoxy liquid coated; DFT minimum 250 micron, shade RAL 5005 / 5015 (BLUE)
10 - Hydro-test Seat : Seat : 10/16 Kg/cm2; Body: 15 / 24 Kg/cm2
Make-Indian Valve Pvt. Ltd. (IVC) / Kirloskar Brothers Limited KIRLOSKAR) 12.01) 150 mm dia
1
17018
17018.2
... More
200 mm dia
1
28662
28662.6
... More
250 mm dia
1
45523
45523.8
... More
300 mm dia
1
61284
61284.1
... More
350 mm dia
1
107403
107403
... More
400 mm dia
1
138082
138082.8
... More
Repairing of sluice valve with the change of spendle (I.e. S.S. non megnated) flapper adjusting nut & bolts & rod & welding machining of body for fitting the flapper properly complete as per direction of E/I. Kirloskar make. 13.01) 150 mm dia
5
2431
12155
... More
200 mm dia
6
2931
17586
... More
250 mm dia
6
4829
28974
... More
300 mm dia
3
6634
19902
... More
350 mm dia
3
7207
21621
... More
400 mm dia
1
12857
12857.4
... More
Repairing of reflex valve with the change of flapper sheet i/c new lever, rubber sheet, MS ring, S.S.pin shaft & shaft rubber etc. complete Kirloskar make. 14.01) 150 mm dia
5
3026
15130
... More
200 mm dia
5
3182
15910
... More
250 mm dia
6
4778
28669.8
... More
300 mm dia
3
6378
19134
... More
350 mm dia
3
6991
20973
... More
400 mm dia
1
12354
12354
... More
Constructing masonry Chamber inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 10.00. 15.01) 90 x 90 x 100 cm.
6
14501
87006.12
... More
120 x 120 x 100 cm.
6
20167
121006.32
... More
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
1500
108
163440
... More
Hiring of Diesel Engine (Including cst of Diesel, Lubricant & Operator)
50
250
12500
... More
Hiring of Gas cutting Set With oxygen and LPG Running Time @ 6 Hrs.
5
1875
9375
... More
Hiring of Welding Set Running Time @ 6 Hrs.
5
1650
8250
... More
Charge of Generator (Including cost Service of operating staff, supply of lubricating oil and diesel also) DG Set / Generator 50 KVA
50
728
36415
... More
Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.
276.45
142
39325.01
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements