New Okhla Industrial Development Authority Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

New Okhla Industrial Development Authority Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date13 Nov 2024
Closing Soon26 Nov 2024
Tender Amount₹ 1,95,28,953 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
protection 2KV-4KV with additional 20KV SPD connected, Toughened transparent glass having the IK protection up to IK05, Painting : Silver Grey................ range of 0°C to 50°C , LED life should be at least 70,000 burning hours at L70 at 25 degree centigrade. Luminaire should be inclusive of factory fitted male/female 2 Pin waterproof connectors & Cable with min approx 300mm(±10%) length for loop-in-loop-out in pre wired conditions as per IS standard. Luminaire Light Engine PCB should be Metal Core PCB made of high grade Al 5052 with not less than 70 micron copper thickness & 2 W/mk thermal conductivity for better performance & thermal management. LM79, IK05, IP66, TTC Certificates from a NABL Acrediated laboratory.Also BIS & M80 Report to be submitted by Manufecturer/OEM. LED................................... Surge : IEC 61000-4-5, EMC : EN 55015 Including Power supply & connectors .Make: Color Kinetics/LT/ Unilamp/Traxon/ Thorn ) Complete in all respects as per direction of E/I

450

27550

12397500

... More
SITC of Outdoor LED System wattage not more than 80W, System efficacy100LPW (±5%), CCT=3000Kfor uniform illumination ensuring every LED in Luminaire reproducing same color at all time. Fixture should have Integral Driver Fixture should be compatible for DMX512 .Housing should be Extruded Aluminium alloy ensuring optimum thermal management , Fixture should be available in Diffused optics (As per approved concept & Site requirement). Secondary Lens should be of PMMA material & covered with Heat Resistance Toughened Glass / PC cover, Ingress Protection should not be less than IP66, Impact Resistance should be IK08 or more. Total Inbuilt and Additional Surge protection of more than or equal to 6KV Internal + 20KV Additional SPD along with other necessary protections No Load protection, Over voltage protection, Short circuit protection. LED Life should be 50,000 B Hrs@L70 B10, , PF0.95, Operating voltage range 140-270V AC, Operating ambient Temp 0 to +50°C, Operating Humidity 10-90% Powder coating should be corrosion resistant Nano technology powder coating in Silver grey colour.

-

-

-

... More
Standard Power cable should have IP67 connector. Technical Data Sheet, Type test Certificate from In-House NABL accredited Lab should be submitted on request.Manufacturer/OEM emblem/logo should be embossed into theAluminium housing to allow identification of OEM & traceability till the life of the fixture. Luminaire should comply with Performance & safety standards IEC 60598/ IEC60950 , IEC 60529, IS 10322-5, IS 161- 03/05/06/07, Surge : IEC 61000-4-5, EMC : EN 55015 .Make: Color Kinetics/LT/ Unilamp/Traxon/ Thorn ) Complete in all respects as per direction of E/I

40

17110

684400

... More
Supply, installation, testing & commissioining of Universe (1024 Channels) DMX controller with following features & specifications:This is built on the latest generation of lighting controllers and combines all recent innovations. Designed for DIN rail mounting, this is the perfect solution for midrange lighting installations. Delivered with 1024 DMX channels.The lighting levels, color and effects can be programmed from a PC, Mac, Android, iPad or iPhone using software from our website.It'sKey Features includes • DMX Stand Alone controller • Up to 2 x DMX512 universes (1024 channels) • RDM compatible • USB & Ethernet connectivity for programming/control • Stand Alone mode with 99 scenes • Play scenes in 5 areas / zones • microSD

-

-

-

... More
slot • 8+3 dry contacttrigger ports • Test scenes rotary switch • Windows/Mac software to set dynamic colors/effects . iPhone/iPad/Android remote and programming apps • cloudcompatibility.Technical Data Input Power 12v DC (8‐15V range), Output Protocol DMX512 , Programm ability PC, Mac, Android, iOS, Connections‐USB‐C Ethernet Screw terminals for DMX / RDM Universes, 8+3 Contact ports, 12v powering Battery holder (CR2032), microSD slot Memory SD Card ,Environment IP20 / to 0 to +50°C, Buttons Rotary switch ,OSRequirements Mac OS X 10.8‐10.14 Windows 7/8/10 Standards CE, ETL, Low voltage, EMC, and RoHS compliance with 5 year waranty complete in all respect as per direction of E/I.

1

265500

265500

... More
Programming & Commisioning Charges of above all Lights with different Scenes complete in all respect as per approved by Noida officials

1

295000

295000

... More
Supply, installation, testing & commissioining of 3port DMX Splitter(Din rail Mountable)with following features & specifications: DMX signal splitter enables branching in complex DMX installations. The combination of a large number of receivers in series can be troublesome, therefore it was possible to create branching DMX tracks using a splitter.With Splitter, it possible to split the DMX input signal into 6 independent branches. The individual outputs are galvanically isolated from input and between each other. The output signals are appropriately reinforces, which guarantees correct operation of the entire installation. DMX Splitter is manufactured in a housing adapted for mounting on standard DIN 35mm rails. Specification ‐ Power Supply‐DC12‐ 24V,DMX Channels‐‐ 512,Nos. of DMX Inout‐1 & output‐ 6,Optical Isolation of DMX Lines,Built‐in Terminatior,breakdown voltage of the isolation1000V,current consumption‐ 500mA with 5 year waranty complete in all respect as per direction of E/I.

2

49560

99120

... More
Supply, installation, testing & commissioining of 2 port DMX Splitter(Din rail Mountable)with following features & specifications: DMX signal splitter enables branching in complex DMX installations. The combination of a large number of receivers in series can be troublesome, therefore it was possible to createe branching DMX tracks using a splitter.With Splitter, it possible to split the DMX input signal into 6 independent branches. The individual outputs are galvanically isolated from input and between each other. The output signals are appropriately reinforces, which guarantees correct operation of the entireinstallation. DMX Splitter is manufactured in a housing adapted for mounting on standard DIN 35mm rails. Specification ‐

3

11800

35400

... More
Supply , Installation , Testing & Commissioning of 4 core .5 sq mm DMX Cable Wiring for circuit/ submainwiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable inExisting surface/ recessed PVC conduit as required.

1000

377

377000

... More
Supply , Installation , Testing & Commissioning of 3 core 2.5 sq mm Wire Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required

1600

168

268800

... More
Supply and laying of 40 mm dia heavy duty (2mm thick) PVC conduit complete with bends and other acessories as required and 14 SWG fish steel wire etc. in slab alongwith reinforcement, before concreting and plastering etc. complete in all respects.P.S No. 284(A).

1200

100

120360

... More
Supply and laying of 25 mm dia heavy duty (2mm thick) PVC conduit complete with bends and other acessories as required and 14 SWG fish steel wire etc. in slab alongwith reinforcement, before concreting and plastering etc. complete in all respects.P.S No. 282(A).

1000

59

59000

... More
Supplying and laying of aluminium conductor PVC insulated armoured, served, sheathed cable 1100 Volts grade at a depth of 750 mm. below ground level over a cushion of 75 mm. thick sand alround and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. Clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respects. the armouring of the cable shall be properly connected with the earth conductor by clamps etc. Complete in all respects as per direction for E/I (PS No. 501).

-

-

-

... More
(1) 4 Sq.mm. x 4 Core (PS No. 501)

100

333

33394

... More
(2) 6 Sq.mm. 4 Core (PS No. 501)

100

350

35046

... More
(3) 25 Sq.mm. 3.5 Core (PS No. 501)

100

440

44014

... More
(3) 50 Sq.mm. 3.5 Core (PS No. 501)

190

580

110306.4

... More
S/F of Plain of pin type copper tin plated cable socket(lug) to the cable leads, insulating with tape and making connection etc. Complete in all respects as per direction for E/I (PS No. 504).

-

-

-

... More
1- 4 sq. mm

1080

20

21664.8

... More
2- 6 sq. mm

800

21

16992

... More
3- 16 sq. mm

2

24

49.56

... More
4- 25 Sq.mm.

6

31

191.16

... More
S/Laying of 90 mm dia (OD 90 mm & ID 76 mm nominal) size of (DWC) HDPE Pipes ISI marked along wigh all accessories like socket, bend, couplers etc. conforming to IS 14930, Part-II complete with filling and cutting, jointing etc. direct in ground ( 75 cm below ground level) including excavation and refilling the trench pat excluding sand cushioning and protective covering etc. Complete in all respects. Rex/Duraline/Time/CPE make. as per DSR 2016 item no. 14.16.2 page no. 49

500

249

124500

... More
Supply and fixing of 40 Amp TPN capacity of automatic street light cubical control panel painted with anti corrosive alkali and acid proof paint crossing of time switch TSO 100 series with contractors, HRC fuse, isolating swtich metering instrument & instrument box with CTs etc. in case ofTPN, Complete in all respects. as per PS No. 807f

2

34574

69148

... More
Supply and buring of safe earthing electrode T-19 (Hot dip galvanized), length up to 2000mm outer type 50mm, inner pipe, 22mm terminal dia 12mm, outer GI pipe of 16 SWG and inner GI pipe of 12 SWG with Hot Dip galvanization up to 100 micron filled with crystalline conductive mixture(CCM) having anti corrosive & conductive property with 50 Kgs activated soil (BFC) capable of reducing the soil resistivity with good micture of retaining capicity along with 30cm square C.I. frame with hinged cover & masonry husing (from electrode terminal to switch board, cost of 25x3 G.I. strip will be extra as per PS No. 725A

2

7611

15222

... More
S/F of 25x3 mm. G.I. Strip from earth electrode directly in the ground as required complete in all respects as per direction of E/I as P.S. No. 716

50

106

5310

... More
Operation and Non Comprehensive Maintenance of above all lights, controller, splitters and other all equipments installed by workingagencies including replacement of defective lights and other parts which are under defect Liabiity period with theft liabelity also complete for 2nd year.(Monthly Payment of 27163.16-/ )

1

325958

325958

... More
Operation and Non Comprehensive Maintenance of above all lights, controller, splitters and other all equipments installed by workingagencies including replacement of defective lights and other parts which are under defect Liabiity period with theft liabelity also complete for 3rd year.(Monthly Payment of 40744.91-/ )

1

488939

488939



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.