National Projects Construction Corporation Limited Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
National Projects Construction Corporation Limited - NPCC Tender
Civil And Construction
Civil Works Others
Eprocure
Opening Date25 Jun 2024
Closing DateCancelled
Tender AmountRefer Documents
Costs
EMD
₹ 2,76,415Document Cost
₹ 5,900Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_NPCC_199318_1Tender No
UPZ/366/AH/Baghpat/24-25/183Tender Authority
National Projects Construction Corporation Limited ViewPurchaser Address
-Website
http://http://npcc.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
03 Nos Asstt Technician (Semi Skilled)
-
-
-
01 Nos Reliver (Semi Skilled)
-
-
-
Deployment of Manpower for operation of Sub Station and DG set
12
-
-
CAMC of DG sets - 3 nos ( 750 KVA- 1 No., 500 KVA - 1 No., 10 KVA- 1 No.), and Transformers ( 800 KVA- 2 Nos.) . Pump room and panel and substation etc Cost of batteries not included and only one brakers cost is included.
12
-
-
CAMC includes following activity :
-
-
-
Attending of all electrical complaints as and when called
-
-
-
Preventive and routine maintenance of 3 DG Sets & 2 Transformers, MLT/LT Panel, all Breakers and 11 KVA breaker, Pumps and substation by providing all the consumables.
-
-
-
Servicing & overhauling of DG set & 2 Transformers once in a year through OEM by providing all materials (all type of filters, batteries,charger engine lubricant oil, silica gel, toping up of transformer oil if required at least one in a year)
-
-
-
Repair/replacement of self starter, capacitor bank, if required
-
-
-
Repair /Replacement of indicators, Push Buttons, charger bank, PT,CT, heater and other measuring instruments if required.
-
-
-
Repair of electrical wiring and controling, MCCB ETC
-
-
-
Not Covered in the Contract : Replacement of following item as a whole is not covered under CAMC contract however the repairing is covered under the contract if repairable.
-
-
-
Fuel required for Runing of D G Sets.
-
-
-
Radiator of Engine
-
-
-
AVR (automatic voltage regulator)
-
-
-
Replacement of Engine and generator as a whole
-
-
-
Replacement of ACB/VCB as a whole beyond one quantity
-
-
-
Replacement of any type of panel as a whole
-
-
-
Note : Rates for the items "not covered in the contract" can not be quoted right now because rates varies with time.
-
-
-
Consumbles Goods
-
-
-
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (Group C)
20
-
-
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
10
-
-
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required
20
-
-
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.
-
-
-
Upto 450 mm sweep
5
-
-
510 mm sweep
5
-
-
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
-
-
-
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
100
-
-
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
100
-
-
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
100
-
-
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
-
-
-
1 x 1.5 sq. mm
100
-
-
2 x 1.5 sq. mm
100
-
-
2 x 2.5 sq. mm
100
-
-
2 x 4 sq. mm
100
-
-
2 x 6 sq. mm
100
-
-
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
-
-
-
20 mm
100
-
-
25 mm
100
-
-
32 mm
100
-
-
40 mm
100
-
-
50 mm
100
-
-
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required
-
-
-
5/6 A switch
20
-
-
2 way 5/6 A switch
20
-
-
15/16 A switch
20
-
-
3 pin 5/6 A socket outlet
20
-
-
6 pin 15/16 A socket outlet
20
-
-
Telephone socket outlet
10
-
-
Annual Maintenance of Water Softner Plant
-
-
-
CAMC of water softner plant and daily routine mainteance consumable chemicals and other items on as is where is basis
12
-
-
Operation and CAMC of Fire Fighting System, Fire Hydrant, fire panel and Fire Alarm System
-
-
-
03 Nos Electrician (Skilled)
-
-
-
01 Nos Reliver (Semi Skilled)
-
-
-
Manpower for operation of Fire Fighting System, Fire Hydrant, fire panel and Fire Alarm System. (Materials will be billed as per actual requiremetnt )
12
-
-
CAMC Charges for fire fighting system, Fire Hydrant, DG set , fire station fire panel and Fire Alarm System, refilling of cylinders.
System shall be taken over in healthy condition only.
12
-
-
Pipeline (repair and replacement )
80
-
-
Operation and CAMC of HVAC Plant (2x90 TR and 3x30 TR), 2 Nos. UPS (ETON make)
-
-
-
01 Nos Supervisor (High Skilled)
-
-
-
03 Nos Electrician (Skilled)
-
-
-
03 Nos Asstt Technician (Semi Skilled)
-
-
-
01 Nos Reliver (Semi Skilled)
-
-
-
Manpower for operation of HVAC Plant
12
-
-
Comprehensive Maintenace Charges for 2x90TR and 3x30TR capacity HVAC system & UPS (02Nos.) Total tonnage: 270 Tonne CAMC charges to be taken on total tonnage of chillers 270 tonne. If any plant is shut down for upgradation deduction will be done accordingly
12
-
-
CAMC includes following activities :
-
-
-
Attending and rectification of day to day complaints.
-
-
-
Replenshing of refrigerant after repairing of leakage if any
-
-
-
Repairing/replacement of any type of electrical swithgear
-
-
-
Replacement of V belts, bearing
-
-
-
Repairing/rewinding of motors of any capacity installed for HVAC system. Replacement upto 3 motors, 2 pumps in case beyond repair only.
-
-
-
Overhauling of complete HVAC(Motors, Pumps, Electrical Panels, AHU motors, system once in a year
-
-
-
Cleaning of condenser & cooling coils with chemical once in a year. Intensive Cleaning of AHUs
-
-
-
Preventive maintenance of the complete HVAC equipment once in a quarter i.e. Four times in a year.
-
-
-
Repairing of compressor as and when required.
-
-
-
Maintaining of proper day to day record of equipment as per maintenance schedule.
-
-
-
Comprehensice maintenance of UPS 30 kva and 50 KVA
-
-
-
Air balancing, Annual validation, 10 Sq. meters of Ducting to be replaced per month, Control Cable, beyond that unit rates as per DSR shall be applicable.
-
-
-
Repair /replacement of VFDs and its routine servicing.
-
-
-
Not Covered in the Contract : Replacement of following item as a whole is not covered under CAMC contract however the repairing is covered under the contract if repairable.
-
-
-
Replacement of equipment as a whole such as compressor, condenser coil, cooling coil, body of chiller & AHU & UPS.
-
-
-
Replacement of M S Pipe, Insulation, Ducting, Diffuser/grills, Dampers, control cables.
-
-
-
Replacement of pre, fine & hepa filters.,
-
-
-
BMS system.
-
-
-
Electric & water supply charges .
-
-
-
One time repair of UPS (30KVA)
1
-
-
Manpower for operation & routine maintence ETP, LTDP and incinerator etc at CCSNIAH, Bagpat.
-
-
-
Operator
12
-
-
Comprehensive Maintenace of ETP, LTDP and Incinerator with Small tools and plants, Chemical for ETP, LTDP and incinerator including consumables/spares
12
-
-
DG , Tranformers and Electrical Panels Repair Work
-
-
-
Repair HT/LT Electrical Panels. (Replacement of heavy Switch Gears not included in our scope of work)
1) Repair /Replacement of indicators, Push Buttons, upto 05 nos. MCBs upto rating of 32A.
2) Replacement of damaged gaskets for prevention of dust and entry of insects.Cleaning and closing of any openings at the bottom/ side for prevention of entry of rats.
3) Opening of all doors, side covers, drawl of breaker from the unit and cleaning & dusting of the equipment with cora cloth and vaccum cleaner. 4) Checking and correction of the internal wiring of the unit
5)Oiling of the moving mechanision and check for proper operation.
1
-
-
Repairing of ETP, LTDP, Incinerator plant including piping, fittings, blower, motors, panels etc.
1
-
-
Earthing with GI Pipe 4.5M long, 40 mm dia including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe with charcoal coke and salt as required
20
-
-
Earthing with copper earth plate 600mm x 600mm x 3 mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe of 2.7 M long etc. with charcoal coke and salt as required
5
-
-
Supplying and laying 25mm x 5 mm copper strip at 0.50 Mtr below ground as strip earth electrode, including comnnection/termination with nut, bolt, spring, washer etc. as required
30
-
-
Supplying and laying 25mm x 5 mm G.I strip at 0.50 Mtr below ground as strip earth electrode, including comnnection/termination with nut, bolt, spring, washer etc. as required
100
-
-
Supplying, Installation, testing & Commissioning of small brunt panel in front of electrical room.
2
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements