National Botanical Research Institute Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
National Botanical Research Institute - NBRI Tender
Automobiles and Auto Parts
Eprocure
Opening Date1 Mar 2019
Closing Date12 Mar 2019
Tender Amount₹ 6,48,140 This is an estimated amount, exact amount may vary.
Costs
EMD
₹ 9,707Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2019_CSIR_23765_1Bid Award Id
ViewTender No
1/WKS/ES/74/18-GENTender Authority
National Botanical Research Institute ViewPurchaser Address
-Website
http://https://www.csir.res.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
SUPPLYING AND FIXING OF PVC TRUNKING 100/50 MM END CAP
15
-
-
S/F PVC SWITCH BOX FOUR MODULE
115
-
-
SUPPLYING AND FIXING FOLLOWING MODULAR BASE AND COVER PLATE ON EXESTING MODULAR METAL BOXES ETC AS REQUIRED
4 MODULE
115
-
-
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
-
-
-
15/16 A switch
115
-
-
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
-
-
-
6 pin 15/16 A socket outlet
115
-
-
SUPPLYING AND FIXING FOLLOWING MODULAR BASE AND COVER PLATE ON EXESTING MODULAR METAL BOXES ETC AS REQUIRED
12 MODULE
6
-
-
SUPPLYING AND FIXING FOLLOWING SIZE/MODULES GI BOX ALONG WITH MODULAR BASE AND COVER PLATE FOR MODULAR SWITCHES IN RECESS ETC AS REQUIRED
12 MODULE
SUPPLYING AND FIXING FOLLOWING MODULAR SWITCH SWITCH/SOCKET ON THE EXISTING MODULAR PLATE AND SWITCH BOX INCLUDING CONNECTIONS BUT EXCLUDING MODULAR PLATE ETC AS REQUIRED
15/16 SWITCH
6
-
-
SUPPLYING AND FIXING FOLLOWING MODULAR SWITCH SWITCH/SOCKET ON THE EXISTING MODULAR PLATE AND SWITCH BOX INCLUDING CONNECTIONS BUT EXCLUDING MODULAR PLATE ETC AS REQUIRED
-
-
-
5/6 A SWITCH
50
-
-
SUPPLYING AND FIXING FOLLOWING MODULAR SWITCH SWITCH/SOCKET ON THE EXISTING MODULAR PLATE AND SWITCH BOX INCLUDING CONNECTIONS BUT EXCLUDING MODULAR PLATE ETC AS REQUIRED
-
-
-
3 PIN 5/6 SOCKET OUT LET
6
-
-
S/F TWO MODULE STEP TYPE ELECTRONIC FAN REGULATER ON THE EXESTING MODULAR PLATE SWITCH BOX INCLUDING CONNECTION BUT EXCLUDING MODULAR PLATE ETC AS REQUIRED
10
-
-
SUPPLYING AND FIXING MODULAR BLANKING PLATE ON THE EXESTING MODULAR PLATE AND SWITCH BOX EXCLUDING MODULAR PLATE AS REQUIRED
10
-
-
Supplying & drawing of following sizes PVC insulated copper Conductor single core cable in existing conduit /casing capping as required
-
-
-
3* 2.5 SQ MM
550
-
-
3* 4 SQ MM
400
-
-
SUPPLYING ANF FIXING OF 20 AMP 415 VOLT SPN INDUSTRIAL TYPE SOCKET OUT LET WITH TWO POLE AND EARTH METAL ENCLOSED PLUG TOP ALONG WITH 20 AMP C CURVE SP MCB IN STEEL ENCLOSURES ON SURFACE OR IN RECESS WITHY CHAINED METAL COVER FORT THE SOCKET OUT LET AND COMPLETE WITH CONNECTION TESTING AND COMMISSIONING AS REQUIRED
12
-
-
Supplying and fixing of 6 amp to 32 amp rating240/415volt ‘c’ curve ,miniature ckt breaker suitable for inductive load of following poles in the existing MCB DB complete with connection ,testing and commissioning etc as required
-
-
-
SINGLE POLE
36
-
-
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required.
(Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 4 way (4 + 12), Double door
2
-
-
PROVIDING AND FIXING FOLLWOING RATING AND BREAKING CAPPACITY AND POLE MCCB WITH THERMMAGNETIC RELEASE AND TERMINAL SPREADERS IN EXESTING CUBICLE PANEL BOARD INCLUDING DRILLING HOLES IN CUBICLE PANEL,MAKING CONNECTIONS ETC
A - 100 AMP, 16KA, 4P, MCCB
2
-
-
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 4 way (4 + 12), Double door
1
-
-
S/F OF 63AMP, 4 POLE MCB
1
-
-
SUPPLY OF 50 SQ MM 3.5 CORE XLPE,1100V CABLE
110
-
-
LAYING OF 50 SQ MM ,XLPE POWE CABLE OF 1100 V GARDE ON WALL SURFACE AS PER THE UP TO 95 SQ MM.CLAMPED WITH 1 MM THICK SADDLE
upto 70 sq. mm (clamped with 25x3mm)
100
-
-
SUPPLYING & DRAWING OF FOLLOWING SIZES PVC INSULATED COPPER CONDUCTOR SINGLE CORE CALE IN EXISTING CONDUIT /CASING CAPPING AS REQUIRED
A- 4* 10 SQMM
60
-
-
S/F OF 2' X 2' 30/34WATT LED RECESS MOUNTED LIGHT FITTING, MAKE- PHILIPS/HAVELLS/CG
12
-
-
SUPPLYING AND FIXING OF LED TUBE ROD,22 WATT,T-08 TYPE,4 FEET LONG WITH BATTEN
4
-
-
WIRING FOR LIGHT POINT/ FAN POINT/ EXHAUST FAN POINT/ CALL BELL POINT WITH 1.5 SQ.MM FRLS PVC INSULATED COPPER CONDUCTOR SINGLE CORE CABLE IN SURFACE / RECESSED MEDIUM CLASS PVC CONDUIT, WITH MODULAR SWITCH, MODULAR PLATE, SUITABLE GI BOX AND EARTHING THE POINT WITH 1.5 SQ.MM. FRLS PVC INSULATED COPPER CONDUCTOR SINGLE CORE CABLE ETC AS REQUIRED. GROUP C