Muzaffarnagar Development Authority Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Muzaffarnagar Development Authority Tender
Civil And Construction
Building Construction
Eprocure
Opening Date8 Jan 2024
Closing Date18 Jan 2024
Tender Amount₹ 14,41,000
Costs
EMD
₹ 29,000Document Cost
₹ 2,360Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_UPMDA_878585_6Bid Award Id
ViewTender No
2364/MDA/CD/2023-24 Dt. 05-01-2024 (TB)Tender Authority
Muzaffarnagar Development Authority ViewPurchaser Address
-Website
http://etender.up.nic.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
RCC work with cement, approved Coarse sand and 20mm stone grit in proportion of 1:1.5:3 in raft foundation and footings excluding supply of reinforcement and its bending but including its fixing and binding the same with 24 B.W.G.G.I. binding wire and including necessary centering and shuttering etc. and supply of all materials, labour, T&P etc. required for proper completion of the work, including cost of binding wire. SI.No. 287(a)
21
132510
6310
M-150 brick work in 1:6 cement and fine sand of 1.25 fineness modulus mortar in foundation and plinth including supply of all material, labour T&P etc. required for proper completion of the work as per direction of the work as per direction of Engineer-in-charge. SI.No. 303
25
102250
4090
2 cm thick Damp Proof Course with Cement and approved coarse sand 1:2 with and including water proofing compound (1 Ltr in 1 bag of cement of 50kg) as ordered by the Engineer incharge in the proportion as specified by the manufacturer including supply of all materials, labour, Tools & plants etc. Required for proper completion of the work and including proper curing & shutterings as necessary. SI.No. 360
12.22
2872
235
Painting on DPC or over roof one coat air blown bitumen 0.70 kg/sqm including cost of fuel wood other materials, labour T&P etc. required for proper completion of work. SI.No. 363
12.22
977
80
RCC work with cement, approved Coarse sand and 20mm stone grit in proportion of 1:1.5:3 excluding supply of reinforcement and its bending but including its fixing and binding the same with 24 B.W.G.G.I. binding wire and including necessary centering and shuttering etc. and supply of all materials, labour, T&P etc. required for proper completion of the work, including cost of binding wire.
-
-
-
A) For Column Work SI.No. 289
4.04
31543
7800
B) For Plinth beam SI No. [285+[284(a)-284] Rate=7200+(7400-6900)= 7700.00
4
30800
7700
C) For T-Beam below slab level- SI.No. 289
4.28
33368
7800
D) For Roof Slab SI.No. 284 A
11
81400
7400
(D) For lintels and Sun Shade (R.C.C. mix 1:1.5:3) SI.No. [283+[284(a)-284] Rate=6450+(7400-6900)= 6950.00
1.31
9132
6950
M.S (Tor steel or plain) work in plain work such as RCC or RB work including bending for proper shape and including supply of steel and its wastage, bend, hooks and authorized over lapping shall be measured and including cost of binding wire (Based on S.I No. 504)
36
248940
6915
M-150 class brick work in 1:6 cement and fine sand of 1.25 fineness modulus mortar in super structure for one brick thick wall including supply of all material, labour, T&P etc. required for proper completion of the work as per direction of Engineer-in-charge. (SI.No. 303+309+310)
31
140430
4530
M-150 class brick work in 1:4 cement and approved coarse sand of 2.20 FM mortar in super structure for half brick thick wall including supply of all material, labour, T&P etc. required for proper completion of the work as per direction of Engineer in charge. (SI.No 305a+309+310a)
24
124320
5180
M.S. or iron work in MS Grills/ Stair case railings/ gates/ racks etc. wrought to required form including supply of steel bolts, nuts, wastage etc and their fixing required for proper completion of the work. [SI No.502(A)]
2
12300
6150
M.S. or iron work of small size and section such as Z-SECTION WINDOWS & VENTILATORS OF OPENABLE PANELS excluding glass panes wrought to required form includingc supply of steel bolts, nuts and wastage etc & their fixing required for proper completion of the work. [SI No.502 B-ii]
2
13400
6700
Cement concrete with 2cm gauge approved stone grit,coarse sand & cement in the proportion of 4:2:1 including supply of all materials,labour,Tools & plants etc.required for proper completion of the work. [SI No.279(A)]
2
11500
5750
12mm thick cement plaster with 1:4 cement and fine sand of 1.25 FM mortar over brick work minimum thickness not to be less than 1cm including supply of all material, labour, tools and plants etc, required for proper completion of the work as per direction of Engineer-in-charge. [SI No.584]
186
29760
160
12mm thick cement plaster with 1:4 cement and coarse sand mortar over brick work minimum thickness not to be less than 1cm including supply of all material, labour, tools and plants etc, required for proper completion of the work as per direction of Engineer-in-charge. [SI No.584A]
303
49995
165
Add for extra labour & materials for plaster over rough face of one brick thick wall. (SI No. 596)
123
2460
20
S/F of hexagonal/round GP fan box of approved make made up of 1.0 mm thick ISI marked GP sheet spot welded four to eight holes of 25.4 mm for pipe entry of the box . Holes should be semi shuttered type with 0.5mm GP sheet made upper & lower cover duly screwed fitted with 300mm round zink coated MS bar of 12 mm dia and brand name should be embossed. Fixing with wiring conduit laid in the RCC roof before concreting along with supply of all materials, labour, T & P etc. for proper completiom of work. SI No 1149 SOR 2018E/M
6
900
150
Providing and applying two coats of wall putty of average thickness 1 mm on new surface with approved quality material of Berger/ Birla or similar brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. ( 2 Coats) [SI No. new items of Ch-15]
309
20703
67
Finishing wall with 2 coats weather paint of approved make & quality on new work with two coats to given an even shade i/c supply of all material, labour, T&P etc. required for completion of the work.[SI No. new items of Ch-15]
123
12054
98
Distempering two coat with oil bound distemper of approved brand and manufacture and of required shade on undecorated wall surface to give an even shade over and including a priming coat with cement primer of approved brand and manufacture such as berger, j&k, shalimar, asian paint after thoroughly brushing the surface free from mortar dropping and other foreign matters and also including the surface even with plaster of paris or approved synthetic materials and sand papered smooth including supply of all materials, labour, tools & plants etc required for proper completion of the work. SI NO 649+650
186
14508
78
Painting or varnishing work in small areas or new wood/steel work with one coat ready mixed priming paint and two coat or approved superior quality ready mixed paint or varnish including supply of all materials, labour. T&P etc. required for proper completion of the work. Paint to be used should confirm the ISI.No.103-1950. As per SOR. 641+642
35
3640
104
Providing and fixing cup board shutters with 25mm thick veneered particle board IS: 3097 marked exterior grade ( Grade I ) of approved make including lind class tedk wod lipping of 25mm wide x 12mm thick with necessary screws and bright finished stainless steel piano hinges complete as per direction of Engineer in charge. With non decorative veneering on both sides. [SI No. new items of Ch-9 (9.130.2)]
11
20020
1820
Approximate cost of ISI marked oxidized iron fitting with screws for door & windows etc.(for estimate purpose only) [SI No.473 ]
11
4180
380
Renewing panes of Glass in doors, window & ventilators or fixing in the new work with 4 mm thick Glass panes fixed with breds and putty including supply of all materials, labour, Tools & plant etc. required for proper completion of the work. SI No. 16b + 5% for putty + 5% for labour
1
440
440
2.5 cm (1") thick 1:2:4 plain cement concrete floor with cement, approved coarse sand 2 cm.(1") graded approved stone grit, laid in panels finished with 3mm. (1/8") floating coat of neat cement of cement and marble dust in ratio 5:1 as specified over and including 8 cm(3") thick base concrete consisting of cement, fine sand of 1.25 fineness modulus and brick ballast 4 cm. (11/2") gauge in the proportion of 1:4:8 and removing any overlapping mortar at the joints of the penals if any and giving them a uniform finish, including supply of all materials, labour, Tools & plants etc. required for proper completion of the work. [SI No. 601]
77
42350
550
P/L (Brick coba treatment) integral cement based water proofing treatment including preparation of surface as required for treatment of roofs terrace, sunken portion horizontal surface and side wall etc. consisting of following operations applying and grouting a slurry coat of neat cement using 2.75Kg/sqm. of cement and mixed with proprietary water proofing compound confirming to IS 2645 over the RCC slab including cleaning the surface before treatment laying cement concrete using broken brick/bricks bats 25mm to 100mm size with 50% of cement mortar 1:4 (1cement 4coarse sand) and mixed with proprietary water proofing compound confirming IS 2645 to fequi4red slope and treating similarly the adjoining walls up to 300 height in the rounding of junctions of walls and slabs after two day days of proper curing applying second coat of cement slurry admixed with proprietary water proofing compound confirming IS. 2645 finish the surface with 20mm thick joint less cement mortar of 1:4 ( 1cement 4 coarse sand) and mixed with proprietary water proof compound confirming to IS 2645 and finally finish8ingthe surface with trowel with neat cement slurry and making of 300x300mm square. the whole terrace so finished shall be flooded on water for a minimum period of three weeks to during and for final test all above operations to be done in order and as directed and specified y the E./I with average thickness at Khurra 66mm. [SI No. new items of Ch-11]
77
73150
950
Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design: In 75x75 mm deep chase.
DSR 12.21.1
58
15091
260.2
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. DSR 12.22
4
1066
266.6
Conrete with 4cm guage brick ballast, Fine sand of 1.25 FM and cement, in proposan of 12:6:1 in foundations and under floors, including supply of all materials, labour, Tools & plants etc. required for proper completion of the work (SI No. 273)
6
17910
2985
Finishing wall with water proof cement paint of approved make and quality on new work with two coat to give an even shade including supply of all materials, labour, Tools & plant etc. required for proper completion of the work. (S.I No. 660+661)
180
14940
83
Wiring point for light in PVC conduit with 1.5 sq. mm. FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduit conduit partly concealed in the wall and partly laid in slab alongwith the reinforcement before concreting, complete with 14 SWG copper earth continuity wire, GP box, piano type switch and ceiling rose/angle/ batten holder on 3 mm. thick phenolic laminated backlite sheet etc. complete in all respect, as directed i/c matching colour wash. SI No 138(C) SOR 2018E/M
20
12200
610
Wiring point for fan/ fresh air fan (light duty exaust fan) in PVC conduit with 1.5 sq. mm. FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduit conduit partly concealed in the wall and partly laid in slab alongwith the reinforcement before concreting, complete with 14 SWG copper earth continuity wire, GP box, piano type switch and ceiling rose/angle/ batten holder on 3 mm. thick phenolic laminated backlite sheet etc. complete in all respect, as directed including matching colour wash. SI No 140(C) SOR 2018E/M
10
6710
671
Wiring point for 5amp plug in PVC conduit with 1.5 sq. mm. FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduit conduit partly concealed in the wall and partly laid in slab alongwith the reinforcement before concreting, complete with 14 SWG copper earth continuity wire, GP box, piano type switch and ceiling rose/angle/ batten holder on 3 mm. thick phenolic laminated backlite sheet etc. complete in all respect, as directed i/c matching colour wash. SI No 178(C) SOR 2018E/M
10
2140
214
Supply and fixing of power plug with 15A/250 volt flush type switch and 5 pin 15A/250V flush type universal socket in suitable M.S. box of 175mm x 100mm x 50mm size with phenolic laminated bakelite sheet cover 3mm thick fixed with brass machine screw and cup washer. SI No 1139 SOR 2018E/M
5
3125
625
Supply and wiring of 3 nos 4 sq.mm. FRLSH but in 25 mm dia heavy duty (2 mm thick) PVC conduit FRLSH PVC insulated 1100V grade multistrand single core copper conductor cable partly concealed in wall & partly laid in slab along with reinforcement before concreting, with two number 14 SWG copperearth continuity wire including matching colour wash etc, complete in all respect SI No 261(C) SOR 2018E/M
50
10850
217
Supply and wiring of submain with 3 nos 6 sq.mm. FRLSH PVC insulated multistrand copper conductor cable as earth continuity wire drawn in 25 mm dia heavy duty (2 mm thick) PVC conduit partly concealed in wall and partly laid in slab alongwith reinforcement before concreting, with two number 14 SWG copper earth continuity wire including matching colour wash etc.complete in all respect. SI No262(C) SOR 2018E/M
25
7250
290
Supply and fixing of 6amp to 32 amp SPMCB (10KA) C curve (Cat-B). SI No 1002 SOR 2018E/M
8
1648
206
Supply & Fixing surface/Flush mounting 8 ways SPN distribution board without additional metal door without MCB complete in all respect, as direct by Engineer in Charge. (Cat B) SI No 1024 SOR 2018E/M
1
1090
1090
S&F of 40 Amp. S.P. Isolator (Cat B) SI No 1004(A) SOR 2018E/M
1
250
250
Supply and laying of 25 mm dia heavy duty (2mm thick) PVC conduit pipe complete with bends and other acessories as required and 14 SWG fish steel wire etc. in slab and walls alongwith reinforcement before concreting and plastering etc. complete in all respect SI No 185(III) SOR 2018E/M
52.08
1250
24
Supply and fixing of switch box of 175x100x65 mm size of approved make made up of 1.0 mm thick ISI marked GP sheet, all 4 corners folded and spot welded for screw and holes plugged with PVC nylon caps. Two or more holes for pipe entry of 25.4 mm on upper and lower sides of the box, holes should be semi shuttered type and fitted with heavy brass earth piller duly screwed and brand name should be embossed. Box flushed in wall including cutting of brick work, fixing it to the level with cement - sand mortar, including matching colour wash with supply of all materials, labour and T&P required for proper completion of work as directed at site by the Engineer in charge. SI No 161 SOR 2018E/M
15
2340
156
Supply and fixing of switch box of 100x100x50 mm size of approved make made up of 1.0 mm thick ISI marked GP sheet, all 4 corners folded and spot welded for screw and holes plugged with PVC nylon caps. Two or more holes for pipe entry of 25.4 mm on upper and lower sides of the box, holes should be semi shuttered type and fitted with heavy brass earth piller duly screwed and brand name should be embossed. Box flushed in wall including cutting of brick work, fixing it to the level with cement - sand mortar, including matching colour wash with supply of all materials, labour and T&P required for proper completion of work as directed at site by the Engineer in charge. SI No 159 SOR 2018E/M
20
1960
98
3 mm thick phenolic laminated sheet.
4625
462
0.1
Supply and burying of 40mm dia x 4.5 metres long G.I. pipe vertically for earthing having 12mm dia. Holes spaced 75mm apart drilled up to 2 metre from the bottom complete with earthing lead of No. 6 to 8 SWG GI wire in G.I. pipe up to appron (and from appron to switch board the cost of G.I. wire and pipe will be extra) upto switch board, 30 cm square C.I. box with hinged cover masonary enclosure, funnel at top, alternate layers of charcoal/coke and salt at least 150mm thick alround etc. as per directions of Engineer in charge complete in all respect as per drawing. SI No 701 SOR 2018E/M
1
4076
4076
Supply and laying of 25mm x 3mm G.I. strip from earth electrode directly in the ground as required complete in all respect. SI No 716 SOR 2018E/M
25
2250
90