Municipal Corporation Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Municipal Corporation Tender

Works
Civil And Construction
Eprocure
Opening Date2 Oct 2024
Closing Date16 Oct 2024
Tender Amount₹ 9,41,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Dismantling of existing damaged brick wall with cement mortar etc all complete work

9.43

4413

468

... More
1st class brick work in 1:4 cement mortar with all complete work

12.66

67098

5300

... More
R.CC work (1:1.5:3) with cement course sand &20mm the stone grit including all complete work (S.I.No.279B)

6.49

60357

9300

... More
M.S iron work including cutting bending and praper laying all complete work

764.08

47372

62

... More
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours andshades, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joints with white cement and matching pigments etc., complete

30

43995

1466.5

... More
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by. Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete, DSR 8.31

156.72

161468

1030.3

... More
12mm thick plaster cement mortar consisting of 1 part cement and 4 parts of fine sand of 1.25 finerness modulus

203.47

34793

171

... More
20mm thick rough cast exterior cement plaster and boundry wall

234.99

48877

208

... More
Providing and applying white cement based putty of average thickness1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete

438.46

37817

86.25

... More
Wall painting (two coats) with plastic emulsion paint of first quality approved brand manufacture on undecorated wall surface to give an even shade i/c thoroughly brushing the surface free from mortar droppings and other foreign matter and sand prepared smooth as

438.6

71930

164

... More
Fixing of Mild steel or iron work in Angle iron Door window frame including cutting 14 welding & wastage including supply of all material etc required for proper completion of work.

399.3

24756

62

... More
Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3.15 mm thick M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of read lead paint on all sides and digonal bracing etc complete.As Per- DSR Code 10.5.2Using flats 30x6mm for diagonal braces and central cross plece. D.S.R.

31.86

87933

2760

... More
2 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix: 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer's specifications, This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. DSR 11.4

9.8

7717

787.5

... More
Providing and fixing ISI marked flush door shutters conforming to IS2202 (Part 1) non decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters DSR 18 9.21.1.1 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws

2.31

4358

1886.7

... More
Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with:. DSR 10.30.1

1.08

972

900.55

... More
S/F of 24 guage Aluminum sheet on toilet 19 door shutters bottom including fixing with aluminum greeves

3.15

1228

390

... More
Wiring point for light with 1.5 sq.mm FRLSH PVC insulated multistrand single core Copper Conductor cable in PVC conduit pipe partly concealed in wall & partly laid in slab along with the reinforcement before concreting,complete with 1.5 sq.mm. FRLSH PVC insulated multistrand copper conductor cable earth continuity wire, piano type switches & ceiling rose/angle/batten" holder on 3 mm thick phenolic paminated backelite sheet etc complete in all respects

15

9150

610

... More
Wiring point for fan with 1.0 sq.mm FRLSH PVC insulated multistrand single core Copper Conductor 5.000 No 671.000 3355.000 cable in PVC conduit pipe partly concealed in wall & partly laid in slab along with the reinforcement before concreting.complete with 1.5 sq.mm. FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduit continuity wire, plano type switch & ceiling rose on 3 mm thick phenolic paminated backelite sheet etc complete in all respects

10

6710

671

... More
Wiring point for plug with 1.0 sq.mm FRLSH PVC insulated multistrand single core Copper Conductor cable in PVC conduit pipe partly concealed in wall & partly laid in slab along with the reinforcement before concreting,complete with 1.5 sq.mm. FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduit continuity wire and piano type switches & socket etc., complete in all respects as directed

10

3270

327

... More
Supply and fixing of 6amp to 32 amp SP MC

10

2600

260

... More
Supply and fixing of Ceiling Fans with fan motor of AC permanent insulation cpacitator rating confirming BEE 5 Star rating and IS: 374/79 and Also comply with IS 1709/1984 with latest amendment. The rated voltage 220/240 volts, 50 Hz, 1-PH AC the fan assembled should consist of down rod blades, shakel canopies etc. and with double wall bearing system BEE 5 star rated-1200 mm sweep Sl No. 1501 i

10

18000

1800

... More
Supply and fixing of tubelights including all fittings etc complete

10

11900

1190

... More
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete DSR 11.27

31.5

57016

1810.05

... More
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound onforming to 15. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement: 5 coarse sand) admixed with water proofing compound conforming to IS: 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to 15 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admised with water proofing compound conforming to IS: 2645 and approved by Engineerin-charge. Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement:4 coarse sand) admixed with water proofing compound conforming to IS: 2645 and approved by Engineerin-charge including laying glass fibre cloth of approved quality in top layer of plaster, and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in- Charge: With average thickness of 120 mm and minimum thickness at khurra as 65 mm.

56.84

58809

1034.65

... More
Providing and placing on polythiene Water Supply and Sanitation work Providing and placing on terrace polythlene water storage tank IS: 12701 marked with cover and suitable locking aggangement and making necessary holes for inlet, outlet and overflow pipes but out fitting and baser support tank etc. all complete.

500

4850

9.7

... More
P/F EUROPEAN TYPE WC with seat and 10 lit flushing cistern & CP flush bend with fittings & C.I brackets 40mm flush bend etc complete all fittings, as per required

1

6941

6941.3

... More
P/F INDIAN TYPE WC with seat and 10 lit flushing cistern & CP flush bend with fittings & C.I brackets 40mm flush bend etc complete all fittings, as per required

1

5781

5781.35

... More
p/F white viterous china wash basin with CI/MS brackests 15 mm CP brass waste of standard pattern 550*400mm with 15 mm cp brass pillar tap.

1

2731

2731.45

... More
p/F flexible PVC waste pipe for wash basin including waste fittings 32 mm dia

2

208

104.35

... More
Providing & fixing soil, waste and vent pipes. a) 100mm dia centrifugally cast iron S & S pipe.

10

900

90

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 15 mm nominal outer dia Pipes

10

4096

409.65

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 20 mm nominal outer dia Pipes

10

4781

478.15

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 25 mm nominal outer dia Pipes

10

5619

561.95

... More
Providing & fixing CP brass bib cock of approved quality conforming to IS 8931 a) 15mm nominal bore

5

2171

434.2

... More
Providing & fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS 8931 a) 15mm nominal bore

2

1000

500.35



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.