Get tender documents at just ₹200 per tenderKnow More
Search made simple for latest tendersNo hidden charges. No keyword restrictionsExplore Our Plansor Pay Per Tender
Combined ShapeCreated with Sketch.Awarded Tender: Contract Date - 20 Sep 2019

Ministry Of Micro Small And Medium Enterprises

Banda, Uttar Pradesh

  • Opening Date

    19 Aug 2019

  • Closing Date

    21 Aug 2019

  • Tender Amount

    Refer document

  • EMD

    -

Are you Looking for Joint Venture Partners, Contractor Consortium, Back-to-Back Contractor, Project Financier?
We will help you to find the right match for FREE.
Summary

Spectrophotometer

Don't have sufficient eligibility, BG funds or resources?
We will help you to find the right match for FREE.
BOQ Items

No BOQs Available

RA Number: GEM/2019/RA/15615 Dated: 05-08-2019 RA Document RA Details RA Technical End Date/Time 13-08-2019 18:00:00 RA Life Cycle (From Publish Date) 90 (Days) RA Offer Validity (From End Date) 30 (Days) Ministry/State Name Uttar Pradesh Department Name Agriculture Department Uttar Pradesh Organisation Name N/a Office Name Banda Total Quantity 1 Item Category SPECTROPHOTOMETER MSE Exemption For Years Of Experience And Turnover Yes Startup Exemption For Years Of Experience And Turnover Yes SPECTROPHOTOMETER ( 1 pieces ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Bid Requirement (Allowed Values) TYPE Type of Spectrophotometer UV - VISIBLE UV - VISIBLE Type of Optical System Double Beam Double Beam Monochromator Type Czerny-turner Czerny-turner Detector Type Photodiode Photodiode Spectral Bandwidth Type Fixed Bandwidth Fixed Bandwidth LIGHT SOURCE Light Source Halogen Lamp,Tungsten Halogen Lamp Halogen Lamp, Tungsten Halogen Lamp Diffraction Grating 1200 1200 1 / 5 (lines/mm) Switching of Light Source Automatic Automatic Wavelength Setting And Scanning Automatic Automatic OPTICAL PERFORMANCE Source Wavelength - Minimum 190 190.0 Source Wavelength - Maximum 1100 1100, 1500, 2000, 2500, 2700, 3000, 3200, 3300, 1650 Or higher Resolution 1 1.0 Wavelength Accuracy (+/-) 0.1 0.1 Bandwidth (nm) 1 1 If variable band width, Specify the incremental step value(mm) NA * Scanning Speed (nm/min) 5000 * Focal length (mm) 0 to 49 0 to 49 Photometric measurement modes Transmittance,Absorba nce,Concentration (Wavelength, time),Refl ectance,Energy Transmittance, Absorbance, Concentration (Wavelength, time), Reflectance, Energy Photometric Absorbance (Max) (Abs) (+/-) 4 4 Photometric Absorbance Accuracy (Max) (+/-) 0.002 0.001 - 0.002 Or lower Photometric Transmittance (Max) (+/-) 100 100.0 Photometric Transmittance Accuracy (Max) (+/-) 0.5 0.0 - 0.5 Or lower Photometric Reflectance (Max) (+/-) 100 100.0 Photometric Reflectance Accuracy (Max) (+/-) 0.5 * Stray Light Correction Automatic * Baseline Correction Automatic * 2 / 5 GENERIC Display In-built display In-built display Display type LCD touchscreen LCD touchscreen Display Size 6 6.0 - 30.0 Or higher Test result printing Through external printer Through external printer If inbuilt printer, Type of printer Dot matrix Dot matrix Suitable software for connecting PC & Printer Yes * Connectivity USB,ETHERNET,RS 232 * Internal storage(GB) 32 32.0 - 80.0 Or higher Sample switching/selection Manual * Capacity of Sample holder / Sample Carousel 1 * Mximum Path Length of sample 100 100.0 Number of Cuvettes supplied-inclusive in the scope of supply 10 10 Power Supply 230 V ± 10, 50 Hz * Spares and Consumables inclusive in the scope of supply No No List of Items and Quantity of each item included in the offer - * OPERATING CONDITIONS Minimum Operating Temperature 10 10.0 Maximum Operating Temperature 35 35.0 Operating Humidity (RH) (%) at 40 degree C 80 80.0 WARRANTY Onsite Warranty 1 1.0 Availability of Spares (at extra cost) 10 10.0 Certification Availability of UL/CE Certification as per EN 61010-1:2010 Safety requirements for electrical equipment for Yes Yes 3 / 5 measurement, control, and laboratory use General requirements Conformance to EMC/EMI as per EN 61326-1:2013 Electrical equipment for measurement, control and laboratory use Yes Yes Availability of Test Reports from Central Govt / NABL approved / ILAC acredited lab to prove conformity to the specification No No If yes test report to furnished,to the buyer on demand Yes * * Bold specifications are the golden parameters. * Bidders may note that In respect of non-golden Parameters, the specifications 'Values' chosen by Buyer will generally be preferred over 'Bid requirement ( allowed Values) by the Buyer. Consignee/Reporting Officer and Quantity S.No. Consignee/Reporti ng

Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.