Military Engineer Services Tender

... More
The MES has issued a formal invitation for competitive bids for the Military Engineer Services project, for Provn Of Sewage Treatment Plant At 664 Army Avn Sqn At Jhansi Cantt in Jhansi, Uttar Pradesh, with an estimated contract value of Rs. 3,38,49,368. The bid opening date for this tender is 22-05-2021 and the last date for bid submission is 31-07-2021. Interested bidders for Military Engineer Services tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.

Military Engineer Services - MES Tender

Opening Date22 May 2021
Closing Date31 Jul 2021
Tender Amount₹ 3,38,49,368 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply, install, test and commissioning of silent type Diesel engine driven Generating set of capacity 62.5 KVA/50 KW, 3 phase, 415 Volts, 50 Hz, at 0.8 pf(lag) with Diesel Engine, Alternator and control panel all mounted in acoustic enclosure complete confirming to the detailed specifications as given below :-

1

-

-

... More
Supply, fixing, testing & commissioning of silicon coarse bubble diffuser having disc dia as 150mm (approx), size of bubble 4 to 5 mm with air flow rate as 4 to 5 M3/Hr at pressure of 0.65 Kg/Cm2 to be fitted in stainless steel air grid inside the equalization tank and having minimum port as 8 for air to escape complete all as specified and directed.

14

-

-

... More
S&F of Solid PVC door frame of size 50 mm x 47 mm made out of 5 mm wood coloured PVC sheet and edges, reinforced with MS square tube, as specified in SSR Part-II 2010 (Section 8, on Page no - 175), complete all as specified and directed.

5.7

-

-

... More
S&F of 200 mm long mild steel barrel tower bolts, stove enamelled black, with bright bolt and fixed with screws, complete all as specified and directed.

4

-

-

... More
S&F in replacement of 20 mm dia of Ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iorn pipe and fixed. (minium weight 20 mm-210 gms) etc, complete all as directed.

1

-

-

... More
M & L Treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured)

1.35

-

-

... More
Supply, laying, testing & commissioning of Power Cables, Aluminum Stranded Conductor 95 sqmm, 3.5 core, XLPE Insulated, Cores laid up, PVC Inner sheathed, Armoured with galvanized wire or galvanized steel strip, overall PVC Sheathed, 1100V grade as per IS 7098(Part 1) 1988 complete laid in trenches / floors / fixed to poles / walls / drawn through pipes etc including provn of lugs, glands, nuts, bolts & washers etc for connecting in LT feeder pillar box / transformer bushings and testing on completion all as specified and directed. Note: Excavation, earth work and provn of cable covers / protection pipe etc shall be measured and paid separately under relevant items of BOQ.

20

-

-

... More
M&L for Ductile Iron (DI) fittings, class K-12, such as Bends (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch. "Y" junction, double branch, cross (sockets or socket and spigot or flanged ends as per site requirement) collars, caps and plugs etc suitable for up to 150mm dia pipe complete all as specified and directed.

200

-

-

... More
M&L RCC (Design Mix) M-30 ( using 20 mm graeded aggregate as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like all as specified and directed.

73.19

-

-

... More
M&L for steel round bars 10mm dia and over, cut to length bent to shape required incl cranking bending spirally complete all as specified and directed.

960.12

-

-

... More
No provision of reliever is considered in Sch ‘A’ (BoQ), however contractor have to make necessary arrangements of reliever as per provisions made in Indian labour law/regulation, the contractor shall be solely responsible for providing the same cost of which shall be deemed to be inclusive in the quoted rate.

-

-

-

... More
Supply, connecting & testing of 2 core, 1.5 sqmm power cable with copper conductor, PVC insulated, Cores laid up, PVC Inner sheathed, Armoured with galvanized wire or galvanized steel strip, overall PVC Sheathed, 1100V Grade as per IS IS 1554 Part-1 including taking out of existing unserviceable cable of any description complete all as specified and directed complete all as specified and directed.

50

-

-

... More
GE/Engineer-in-charge shall notity contractor that there will be mandatory break of service of every employee on completion of each 11 month service and will be strictly monitored to avoid any litigation in future.

-

-

-

... More
Cutting into existing manholes for connecting 200mm new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required all as specified and directed

154

-

-

... More
M&L for machine cut Kota stone 20-25 mm thick in riser of steps skirting , dado and pillar, laid over and incl 15mm thick screed bed in CM (1:6), set and jointed with grey cement slurry mixed with pigment to match the shade of the slab, with and including Cutting / Griding / mirror Polishing on Kota stone as per local trade practice, complete all as specified and directed.

3.56

-

-

... More
One light / ceiling fan / exhaust fan point controlled by one switch.

22

-

-

... More
Supply and fix forged brass ball valve of size 25mm NB with screwed female ends conforming to ISI complete all as specified and directed.

15

-

-

... More
M&L DWCPE pipe 150/175 mm (ID/OD) complete laid in trenches including earthwork, removal and return filling and jointed including testing alongwith necessary jointing material tees/ union / socket etc complete laid on PCC beed 150 mm thick PCC in 1:2:4 type B0 of avg depth 2.0 m including packing under and haunching against the side of pipes after they are laid and tested all as specified in IS 16098:2013 and as directed

2094

-

-

... More
The duty staff / operator will be responsible for cleanliness and necessary up keeping of installations, including grass cutting, bush cutting and cutting of small branches of surrounding areas up to 5 meters from the installations. The duty staff will also maintain the installation, machinery, control panels etc clean and tidy. If installation(s) is not found up to the mark, the contractor will be penalized @ Rs 100/- per day till the cleaning and maintenance is not completed. The contractor should also visit the installations once daily and inform defects/ problems if any to concerned JE E/M or Engr-in-charge.

-

-

-

... More
M&L for medium grade galvanised steel water tubing with and incl all fittings and fixtures, fixed to wall or laid in floors for 20 mm bore, concealed or exposed, complete all as specified and directed.

30

-

-

... More
S & F 110mm bore PVC (SWR) pipes single socketed in any length fixed/ laid in trenches or in floors complete all as specified and as directed.

25

-

-

... More
Use & waste formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter rough finished suface of concrete all as specified and directed.

1664.62

-

-

... More
Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5 m deep for foundation etc., and getting out in any types soil all as specified and directed..

1696.63

-

-

... More
S&F of 150mm long barrel tower bolt aluminum anodized extruded section fixed with cadmium plated screws complete all as specified and directed.

2

-

-

... More
The Operator must be qualified/skilled enough in operation of various equipments / pumps of STP and LT panel boards / control valves and other connected accessories for smooth & uninterrupted operation of STP plant. The operator(s) must be qualified enough to understand the functions as well as routine/periodical maint of each equipments / items of STP plant. He should be well conversant with the lay out diagram / single line diagram of various equipments / items of STP plant.

-

-

-

... More
Supply and fix socket 16A & 6A, 2-in-1 flush type universal 240V, 50Hz complete all as specified and directed.

4

-

-

... More
The contractor shall be solely responsible in case of any accident for the risk involved in the work and nothing shall be paid by the department.

-

-

-

... More
S&F of Ringfit PVC (SWR) pipe of 75 mm nominal dia size, wall thickness of 3.5 mm, Type A, in any length, single socketed type as per IS : 13592-1992 with latest amendment, having one end of the pipe as plain and other end as self socketed with an integral groove to hold the rubber gasket, with and incl rubber tighten gaskets, ringfit sockets etc, complete pipe duly fixed to wall, complete all as specified and directed.

15

-

-

... More
Supply and erection in position of Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-55 (11.0 meters long) including painting of poles with two coats of aluminium paint over a coat of red oxide primer on all exposed surfaces and black bituminous paint on embedded portion and Zebra marking on pole with black paint up to one meter height above PCC coping including pasting of radium reflector band / strips (Make: 3M or equivalent) of 5cm wide in Green (02 Nos) & White (01 No.) colour shall be provided at a height of 1.25mtr from coping of pole complete all as specified and directed. Note: Excavation and concrete shall be measured and paid separately under relevant items of this BOQ.

2

-

-

... More
Supply and fixing of Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required with 32mm x 6mm galvanized iron strip complete all as specified and directed.

100

-

-

... More
S&F for 1.25 mm lath Steel rolling shutters, with ball bearing, and Safety lever locks mild steel with 4 levers as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete: but gear operated type with chain wheel and hand chain all as specified and directed.

7.5

-

-

... More
M&L for machine cut Kota stone slab flooring 18-20 mm thick and laid over and incl 15mm thick screed bed in CM (1:6), set and jointed with grey cement slurry mixed with pigment to match the shade of the slab, with and including Cutting / Griding / mirror Polishing on Kota stone as per local trade practice, complete all as specified and directed.

123.28

-

-

... More
Supply and spread floating media for MBBR, Cylindrical / circular shaped - Wagon wheel design having external fins, surface area - 500 m2/m3, nontoxic, PP black, having specific gravity of 0.90 – 0.92 gms/cm3 including taking out existing unserviceable media strainer of any description complete all as specified and directed.

11.7

-

-

... More
Supply, laying, jointing and testing of Galvanized Iron (GI) pipe Heavy Class of size 80mm dia bore with all necessary fittings such as sockets, bends, tees, elbows, unions, nipples etc as per site requirement complete all as specified and directed.

2400

-

-

... More
One 6A socket point controlled by one switch on same board.

4

-

-

... More
Supply, connecting & testing of 3 core, 10 sqmm power cable with aluminium conductor, PVC insulated, Cores laid up, PVC Inner sheathed, Armoured with galvanized wire or galvanized steel strip, overall PVC Sheathed, 1100V Grade as per IS IS 1554 Part-1 including taking out of existing unserviceable cable of any description complete all as specified and directed.

60

-

-

... More
Supply and fixing of Danger notice plate of 1.6mm thick mild steel sheet, vitreous enameled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT 11 KV, 25x20cm size complete all as specified and directed.

4

-

-

... More
Excavation in trenches n.exc 1.50 m wide and n exc 1.50 m depth for foundation n.exc. 10 sqm on plan and getting out in Hard/ dens soil from sewage line etc, all as specified and as directed.

1503.4

-

-

... More
The operator should have necessary tool kit (i.e. wrench, spanner, screw driver set each sizes, line tester, combination and cutting pliers, cutting knife, hand gloves suitable for available voltages, Test lamp with conductor and holder etc) available with him every time at installation.

-

-

-

... More
Supply and fix Cast Iron foot valve of size 65mm NB Flanged end / Screwed end swing type / ball type ISI marked including replacement of necessary packing material, bolts, nuts and washers complete all as directed.

6

-

-

... More
Removing excavated material not exc. 50 m and depositing where directed at a level n exc. 1.5 m above the starting point all as specified and directed.

1322.85

-

-

... More
Use & waste formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc all as specified and directed.

309.36

-

-

... More
Supply, installation, testing and commissioning of Centrifugal monoblock water pump with CI casing, bronze impeller, high tensile steel shaft, with mechanical seal complete suitable for 150 LPM discharge at a head of 20 meters coupled with suitable AC 3 Phase, 415 V, 50 Hz, TEFC squirrel cage induction motor with IP 55 degree of protection and Class 'B' insulation but capacity of motor shall not be less than 2 HP complete with and including MS base frame with anti-vibration mounting pads on suitable PCC foundation as per manufacturer's recommendations complete all as specified ad directed. (Arboriculture Pump) (01 Working + 01 Standby)

2

-

-

... More
S&F in replacement of 20 mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed, complete all as specified and directed.

1

-

-

... More
One 6A socket point controlled by one switch on independent board.

6

-

-

... More
Supply and fix LED street/security light fitting 25 watts with high efficiency long life LEDs with In-built electronic driver complete housed in pressure die-cast aluminium housing covered with polycarbonate cover with IP66 degree of protection including GI pipe bracket made up of 25mm dia medium grade GI pipe of length 1.50m bent to required shape and fixing on walls with suitable MS clamps(02Nos) made up of 25mmx4mm MS flat, nuts, bolts and washers and provision of 3 core twisted flexible copper cable of size 0.5 sqmm from ceiling rose to connector of fitting complete all as specified and as directed.

4

-

-

... More
M&L for RCC (Design Mix) M-30 ( using 20 mm graeded aggregate as in Columns, pillars, piers, posts and struts all as specified and directed.

26.02

-

-

... More
M&L Treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface all as specified and directed.

21.59

-

-

... More
M&L for Gully trap PVC(SWR) 125/110 mm, setting and jointing with solvent cement all as specified and directed.

1

-

-

... More
Supply and fixing of 100mm dia bore tubes, 'light grade' galvanized, with all fitting and fixed to poles / structure or laid in trenches/ floors for cable protection complete all as specified and directed.

10

-

-

... More
Excavation over area, exc. 7.50 m deep but n exc 9.00 and getting out for Hard/ dense Soil all as specified and directed.

51.58

-

-

... More
All as per item No. 193.00 here-in-before but of size 10 sqmm, 2 core.

300

-

-

... More
Supply and fix in replacement of 25mm NB, Stainless Steel (SS) 304, SCH 10 seamless pipe for coarse bubble air grid for MBBR tank and equalization tank as per site requirement and OEM design complete all as specified and directed.

35

-

-

... More
M&L for medium grade galvanised steel water tubing with and incl all fittings and fixtures, fixed to wall or laid in floors for 15 mm bore, concealed or exposed, complete all as specified and directed.

15

-

-

... More
All the pumps / Chemical dosing system / Air blower / LT control panels / starter panel etc, will be operated by one operator in one shift simultaneously or as per OEM's control manual. In case, additional manpower other than mentioned here-in-above, will be required for smooth functioning of Plant/installation, the contractor shall be solely responsible for providing the same without any extra cost and no extra payment will be made in this effect at any stage.

-

-

-

... More
Supply, installation, testing and commissioning of Centrifugal monoblock water pump with CI casing, bronze impeller, high tensile steel shaft, with mechanical seal complete suitable for 50 LPM discharge at a head of 10 meters coupled with suitable AC 3 Phase, 415 V, 50 Hz, TEFC squirrel cage induction motor with IP 55 degree of protection and Class 'B' insulation but capacity of motor shall not be less than 0.5 HP complete with and including MS base frame with anti-vibration mounting pads on suitable PCC foundation as per manufacturer's recommendations complete all as specified ad directed. (Centrifuge filtrate water pump) (01 Working + 01 Standby).

2

-

-

... More
M&L for cement concrete in foundation filling and mass concrete type C2 1:3:6 (40 mm graded aggregate) all as specified and directed.

60.37

-

-

... More
Excavation in trenches n.exc 1.50 m wide and exc 3.0 m and n.exc 4.5 m depth for foundation n.exc. 10 sqm on plan and getting out in Hard/ dense soil from sewage line etc, all as specified and as directed.

162.59

-

-

... More
S&F of 35mm thick factory made modular designer flush doors, solid core construction, with block board core and prelamination on both sides, complete all as specified and directed.

10.08

-

-

... More
On completion of the manning contract, the contractor will hand over all E/M & Bldg assets under the contract to the Department. Any loss / damage / deficiency occurred shall be made good or regularized by the contractor at his own risk and cost.

-

-

-

... More
M&L RCC (Design Mix) M-30 ( using 20 mm graeded aggregate Chullah hoods; stairways (except spiral staircases) including steps (square or spandril), string pieces, carriages, etc., complete, any section straight or winding, but excluding landings; RCC water tanks upto 1500 litres all as specified and directed.

7.39

-

-

... More
Supply, laying, jointing and testing of Centrifugally Cast (Spun) Ductile Iron Pressure Pipe with Socket and Spigot ends suitable for Push-on-Jointing, Class "K-9" of size DN 150mm duly applied with Zinc Coating with finishing layer of Bitumen on external surfaces and Cement Mortar Lining with Bituminous Seal Coat on internal surfaces complete confirming to IS-8329(2000) duly ISI marked and all as specified and directed.

860

-

-

... More
Notes for Item No 240.01 :- The duty(s) of operating staff / nature of work(s), the followings provisions & conditions and rate(s) quoted is deemed to be inclusive for such provisions & conditions:-

-

-

-

... More
All as per item No. 1 here-in-before but suitable for 470 LPM discharge at a head of 25 Meter. (Location: Raw Sewage Collection Sump - 2 near JCOs Md Accn) (02 Working + 01 Standby)

3

-

-

... More
M&L Forming construction joints 30mm deep x 10mm wide filled with sealing compound grade A all as specified and directed.

7

-

-

... More
Supply and fix forged brass ball valve of size 40mm NB with screwed female ends conforming to ISI complete all as specified and directed.

3

-

-

... More
S&F of 150 mm butt hinges medium weight cold rolled mild steel ISI marked and fixed with mild steel wood screws or welded to angle frame, complete all as specified and directed.

12

-

-

... More
Supply and fix MCB 6 - 32A, 10 KA, single Pole, 'C' curve, 240 V, 50 Hz complete all as specified and directed. s

6

-

-

... More
Supply and fixing of Switch Air Break, Gang Operated, Triple Pole, mechanically operated, vertical mounted on 09 insulators and steel frame, with operating mechanism worked from ground level, for current rating up to 200 amps suitable for 11000 volts grade complete all as specified and directed.

2

-

-

... More
Calcium Hypo Chlorite for chlorination of treated water will be issued under Schedule 'B' as free for consumption only in STP plants.

-

-

-

... More
Mounting Arrangement: Engine and Alternator shall be mounted on a common MS fabricated base frame with Anti Vibration Mounting Pads

-

-

-

... More
M&L for 150mm dia SWG pipes grade'A' laid in trenches and jointed in CM 1:1 complete all as specified and as directed.

15

-

-

... More
Supply and fix Cast Iron Non Return Valve (NRV) of size 80mm NB with flanged ends swing type / ball type ISI marked including necessary packing material, bolts, nuts and washers complete all as directed.

5

-

-

... More
S&F of 150mm aluminum handle cast type anodized complete all as specified and directed.

4

-

-

... More
S&F in replacement of towel rail 600 mm long and wall bracket made of cast copper alloy, chromium plated, complete all as directed.

1

-

-

... More
M&L for Point wiring with 1.5 Sqmm FRLS insulated, unsheathed, multistranded, 1100 Volts grade copper conductor cable single core conforming to IS:694 along with one run of 1.5 Sqmm FRLS insulated copper conductor cable green in colour for continuous earthing drawn through and including medium grade rigid PVC conduit conforming to IS:9537 (Pt-III) and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 20mm(OD), concealed in wall/ floor etc including provision of pressed steel terminal box of thickness not less than 18 SWG / with earth dolly of suitable size concealed in wall and covered with 3 mm thick phenolic laminated hylam sheet fixed with brass/GI screws for mounting switches, sockets, fan regulator, etc.as per site requirement complete all as specified and directed for the following points:-

-

-

-

... More
M&L for RCC (Design Mix) M-25 ( using 20 mm graeded aggregate as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete all as specified and directed.

52.89

-

-

... More
S&F in replacement of 1st quality vitreous china squatting pan Orissa pattern of size 580x440 mm, white colour with integral foot rests water closet including flush pipe but exluding flushing cistern, duly fixed in lime concrete bedding and making good of floor surface, complete all as specified and directed.

1

-

-

... More
Excavation in trenches not exceeding 1.5m wide and exceeding 1.5m and not exceeding 3.0m depth and getting in any type of soil for laying of cables/ for erection of poles etc complete all as specified and directed.

0.5

-

-

... More
(i) Bus bar: TPN copper bus bar of suitable rating provided with heat shrinkable coloured PVC sleeve insulation mounted on insulators for main bus bar and Continuous earth bus with GI strip of suitable size capable for carrying full short circuit current for 1 sec shall be provided at bottom of the panel. (ii) Incomer: (a) MCCB, 100 A, 4 Pole, 25 KA (Ics=100%Icu), 415 V, 50 Hz, with adjustable thermal - magnetic release - 01 No (b) Digital Voltmeter with selector switch - 01 Set. (c) Digital Ammeter with selector switch & suitable ratio of CT's - 01 set of 03 (d) LED Pilot light indication lamps for R,Y,B phases - 01 Set of 03 (iii) Outgoing:- (a) Motor Protection Circuit Breaker (MPCB), rotary type, up to 10 Amps, 3 Pole, 100 KA, with short circuit & overload protection along with Direct Online (DOL) starter suitable for up to 5 HP 3 ph, 415 V, 50 HZ, AC motor along with LED pilot light indication lamps to indicate motor ON & OFF position - 10 Sets (b) Motor Protection Circuit Breaker (MPCB), rotary type, up to 2.5 Amps, 3 Pole, 100 KA, with short circuit & overload protection along with LED pilot light indication lamps to indicate motor ON & OFF position - 05 Nos (c) MCB SPN 32 Amps, 10 KA, 'C' curve - 06 Nos.

-

-

-

... More
Excavation over area, n exc. 1.5 m deep and getting out for Hard/ dense Soil all as specified and directed.

387.84

-

-

... More
Note for Item No. 1:- (i) PCC foundation for DG set as per manufacturer's recommendations shall be measured and paid separately under relevant items of Schedule 'A'. (ii) On successful installation, the DG set shall be subjected to load test as specified below :- Phase-I : No-load test for 01 hour in the presence of Engineer-in-Charge. Phase-II : Load test for 12 hours continuously (at 25% of full load for fist one hour, 50% of full load for second one hour, 75% of full load for third one hour, 100% load for next 08 hours and 110% of full load for last one hour). Resistive type load bank or Water Load, Fuel and testing instruments as required for load testing shall be arranged by the contractor and cost of the same shall deemed to be included in the quoted rate. (iii) Phase-II load test shall be carried out in the presence of testing officer nominated by accepting officer or IEM.

-

-

-

... More
Supply and fixing of Post top lantern Black ABS plastic spigot, spun aluminium canopy, with clear acrylic diffuser and accessories along with LED lamp 9 Watt with B22 base lamp holder including provision of 50mm dia GI pipe of 300mm long (02 Nos) grouted on gate pillars for mounting of light fitting complete all as specified and directed.

2

-

-

... More
M&L 15mm thick rendering on fair faces of brick or concrete surfaces in CM 1:4 finished even and smooth without using extra cement all as specified and directed.

2391.06

-

-

... More
S&F of 150mm Mild Steel Handle cast type complete all as specified and directed.

8

-

-

... More
S&F of GI wire cloth 1 mm in nominal dia with 50X50 mm mess fixed to MS angle frame with expandable metal 1 mm dia to cover the Sewage sump, complete all as specified and directed.

32.02

-

-

... More
M&L 25 mm thick Damp proof course to horizontal or vertical surfaces including necessary form work in cement concrete 1:2:4 type B-0 (using 12.5 mm graded stone aggregate), complete all as specified and directed.

21.59

-

-

... More
Mild steel TMT bars 5mm dia and over upto and including 10mm dia as in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified and directed.

12583.34

-

-

... More
M&L for RCC (Design Mix) M-25 ( using 20 mm graeded aggregate) as in Beams, cantilevers, bressumers, lintels all as specified and directed.

12.27

-

-

... More
Supply and fix Cast Iron foot valve of size 50mm NB Flanged end / Screwed end swing type / ball type ISI marked including replacement of necessary packing material, bolts, nuts and washers complete all as directed.

2

-

-

... More
S&F 600/610 mm dia punched tape concertina coil as per IS: 4454 with galvanised coating and punched tape material as per IS:513 deep drawn quality with galvanised coating having medium barbs (bars length: 24+1mm, pitch between two barbs 35+1mm) fixed in position and secured to both sides of shaped angle iron post, stretched to a length of 6 to 8 mm to achieve 600/610mm dia, weighing 8 kg (+5% as in fencing to steel post and another coil/ MS ribs including fixing with special galvanised fasteners such as J clips C clips U clips all as specified and directed having 4 rings between angle iron frame of dia 1.40 mtr all as specified and directed.

250

-

-

... More
All as per item No. 193.00 here-in-before but of size 50 sqmm, 3.5 core.

100

-

-

... More
M & L for construction of Sockage wells of size 1.20 mtr internal dia and 4.5 mtr efective depth, Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of sizecomplete all as specified and directed.

1

-

-

... More
M&L for box type steel window with 80x40x1.25 m MS tubular frame with side hung shutters ( double shutter for glass and gauze) without sash bars jointed together with and incl grill using 12 mm square bar @ 10 cm C/C incl box type hinges with steel handle and steel pag stay complete glazing bars doweled and welded complete all as specified as directed. Note:- (a) The Glass / gauze shell be measured and paid separately. (b) Side hung Z-Section shutter shall be of size 20mm x 20mm x 25mm and 0.3mm thick.

16.2

-

-

... More
Use & waste formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter all as specified and directed.

747.16

-

-

... More
S&F of 100 mm size butt hinges, extruded aluminum alloy with galvanized mild steel pin type B-21 anodized complete all specified and directed.

6

-

-

... More
M & L for preparing newly plastered surfaces of wall and applying two coat of cement base paint over a coat of primer complete all as specified and directed.

2186.66

-

-

... More
S&F Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long, complete all as directed.

1

-

-

... More
M&L for preparation of new plastered surface and applying two coats of oil bound distemper, over and incl a layer of wall care putty to get even and smooth level finish on new plastered surface of internal wall, complete all as specified and as directed.

231.36

-

-

... More
M&L for PCC 1:4:8 type D2 using 40 mm graded stone aggreagate as in sub base of flooring complete all as specified and directed.

70.33

-

-

... More
M&L for cutting of existing road / hard standing up to 15 cm depth for laying of pipe lines and making good the disturbed surfaces by providing PCC 1:2:4 type B-1 (using 20mm graded aggregate) after laying of pipes lines and returning filling of soil, complete all as specified and directed. Note:- Excavation and earth work below road / hard standing will be measured and paid under relevant items.

5

-

-

... More
All as per item No. 193.00 here-in-before but of size 10 sqmm, 4 core.

100

-

-

... More
Material and labour for M.S. Black Pipe plain end as per IS:1239 (I), nominal bore 65 mm dia, 'C' class with all fittings including cutting, welding and joining etc as per site requirement and applying two coats of synthetic enamel paint of approved colour over a coat of red oxide primer complete all as specified and directed complete all as specified and directed.(For compressed air from air blower to MBBR and equalization tank).

30

-

-

... More
Material & Labour for HT 11 KV cable route indicator made out of Cast iron plate round or oval shaped duly embossed and painted as per standards and fixed to angle iron 25mm x 25mm x 4mm embedded in PCC 1:3:6 block of size 300mm x 300mm x300mm and placed over the cable line complete all as specified and directed.

5

-

-

... More
It is an explicit condition of the contract that payment of wages to tradesmen/workers employed on the work shall be made through bank account of individuals only. The contractor shall deposite the payment in Ist week of every month and will confirm to Engr-in-Charge by showing the payment slip/bank transaction document from bank. The wage paid to the tradesmen/workers shall not be less than minimum wages/fair wages as notified time to time by state / central Govt (Which ever is more).

-

-

-

... More
Removing excavated material exc. 50m upto 100 m and depositing where directed at a level n exc. 1.5 m above the starting point all as specified and directed.

385.18

-

-

... More
M&L Treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area all as specified and directed.

42.23

-

-

... More
Alternator : The Alternator shall be of capacity 62.5 KVA/ 50KW, 415 Volts, at 0.8 pf(lag), 50 Hz, 3 phase, 4 wire system, suitable for operation at 1500 RPM. The Alternator shall be brushless type, screen protected, revolving field, self excited, self regulated through an AVR, copper wound, Class 'H' insulation, having ±1.0% voltage regulation (max) in static conditions and continuous duty operation.

-

-

-

... More
Excavation over area, exc. 4.50 m deep but n exc 6.00 and getting out for Hard/ dense Soil all as specified and directed.

96.63

-

-

... More
S&F in replacement of overhead shower of dia 125 mm round shape single flow, ABS body chrome plated fancy type, with and incl swirl type shower arm of 20mm dia with wall flange made of cast copper alloy, chromium plated fancy type, complete all as directed.

1

-

-

... More
(i) Bus bar: TPN copper bus bar of suitable rating provided with heat shrinkable coloured PVC sleeve insulation mounted on insulators for main bus bar and Continuous earth bus with GI strip of suitable size capable for carrying full short circuit current for 1 sec shall be provided at bottom of the panel. (ii) Incomer: (a) MCCB, 63 A, 4 Pole, 25 KA (Ics=100%Icu), 415 V, 50 Hz, with adjustable thermal - magnetic release - 01 No (b) Digital Voltmeter with selector switch - 01 Set. (c) Digital Ammeter with selector switch & suitable ratio of CT's - 01 set of 03 (d) LED Pilot light indication lamps for R,Y,B phases - 01 Set of 03 (iii) Outgoing:- (a) Motor Protection Circuit Breaker (MPCB), rotary type, 10 Amps, 3 Pole, 100 KA, with short circuit & overload protection along with Direct Online (DOL) starter suitable for up to 5 HP 3 ph, 415 V, 50 HZ, Sewage Submersible pump set along with LED pilot light indication lamps to indicate motor ON & OFF position - 03 Sets (b) MCB SPN 20 Amps, 10 KA, 'C' curve - 02 Nos.

-

-

-

... More
Material & Labour for High density polyethylene pipes (HDPE) 50mm dia of pressure rating 6 kgf/cm2 laid in trenches/floors/duct or fixed on walls /pole for cable protection complete all as specified and directed.

500

-

-

... More
Excavation in trenches n.exc 1.50 m wide and exc 1.50 m and n.exc 3.0 m depth for foundation n.exc. 10 sqm on plan and getting out in Hard/ dense soil from sewage line etc, all as specified and as directed.

766.11

-

-

... More
Supply and fix socket 6 Amps, 2-in-1 flush type universal 240V, 50Hz complete all as specified and directed.

10

-

-

... More
Supply, laying, testing & commissioning of XLPE insulated, insulation screening with extruded semi conducting compound in combination with copper tape, cores laid up, PVC inner sheathed, galvanized steel strip armoured and overall PVC sheathed electric power cables(heavy duty) with stranded aluminum conductor of cross sectional area 95 sqmm, 3 core, 11000 volts grade(Earthed) cable confirming to IS:7098 (Part-II) complete all as specified and directed. Note: Excavation, earth work and provn of cable covers / protection pipe and cable jointing kit etc shall be measured and paid separately under relevant items of BOQ.

600

-

-

... More
All as per item No. 218 here-in-before but one 16A socket point controlled by one 16A switch on independent board with 2.5 sqmm wires.

4

-

-

... More
M&L for mild steel section as in door/windows chowkhats frame of steel gate of grade Fe-410-0 or Fe-310-0 including all necessary machine wks i.e. cutting, welding, grinding etc, complete all as specified and directed.

46.2

-

-

... More
M&L for clearing the non accessible roof top surface of concrete and providing water proofing treatment to roof slab with APP based modified polymeric membrane centre core 100 micron HMHDPE outer film 20 micron each having thickness 3mm weight not less than 3 kg/sqm with 100mm overlap laid as per manufacturers instructions, complete all as specified and directed with following courses of description below :- (a) Applying evenly a coat of bituminous primer confirming to IS-3384-1965 @ 0.40 kg/sqm on prepared surfaces till the surface is properly impregnated. (b) Second coat of bonding material using blown grade bitumen 85/25 conforming to IS-702 @ 1.20 kg/sqm ( c) third course is laying APP based modified membrane described hereinbefore with 100mm overlap in longitudinal direction and 100mm in tranverse direction, all joints and changes in all directions should be curved with cement mortar (1:3) mixed with SBR latex @ 200ml per bag of cement and cured well before laying the membrane. (d) Fourth coat of bonding materials using blown grade bitumen 85/25 confirming to IS-702 @ 1.20 kg/sqm (e) Apply a coat of bituminous aluminium paint @ 0.20 kg/sqm.

168.73

-

-

... More
S&F in replacement of 10 ltr capacity PVC valve less symphonic action type flushing cistern, white, with inlet ball valve, float and handle with and including wall bracket, 32 mm dia PVC flush pipe and connected to squat pattern / pedestal pattern water closet, including all joints and making good to the wall & floor,complete all specified and directed.

1

-

-

... More
Supply and fix Cast Iron sluice valve of size 150mm NB, having pressure rating PN 1.6, double flanged, non-rising stainless steel spindle with iron wheel complete as per IS:14846 and all as specified and directed.

1

-

-

... More
Suitable conveyance shall be provided by the contractor to all operating staff under this contract to perform the duties as assigned to them and cost of this provision is deemed to be included in the quoted rate.

-

-

-

... More
M&L for RCC M-25 (design mix) (using 20mm gradded stone aggregate)as in column, llar etc all as specified and directed.

26.91

-

-

... More
S&F of Ringfit PVC (SWR) pipe of 110 mm nominal dia size, wall thickness of 3.5 mm, Type A, in any length, single socketed type as per IS : 13592-1992 with latest amendment, having one end of the pipe as plain and other end as self socketed with an integral groove to hold the rubber gasket, with and incl rubber tighten gaskets, ringfit sockets etc, complete pipe duly fixed to wall, complete all as specified and directed.

10

-

-

... More
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement including forms, moulds, mitered / stopped ends all as specified and directed.

250

-

-

... More
S&F galvanised, 2 strands, steel barbed wire 2.24 mm dia barbed with 2 mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with provision of galvanised mild steel wire, staples or steel pins etc all as specified and directed.

95

-

-

... More
Supply, installation, testing and commissioning of Centrifugal monoblock water pump with CI casing, bronze impeller, high tensile steel shaft, with mechanical seal complete suitable for 135 LPM discharge at a head of 25 meters coupled with suitable AC 3 Phase, 415 V, 50 Hz, TEFC squirrel cage induction motor with IP 55 degree of protection and Class 'B' insulation but capacity of motor shall not be less than 2 HP complete with and including MS base frame with anti-vibration mounting pads on suitable PCC foundation as per manufacturer's recommendations complete all as specified ad directed. (Filter feed pump) (01 Working + 01 Standby).

2

-

-

... More
Supply and fix Cast Iron sluice valve of size 50mm NB, having pressure rating PN 1.6, double flanged, non-rising stainless steel spindle with iron wheel complete as per IS:14846 and all as specified and directed.

11

-

-

... More
M&L for providing precast reinforced cement concrete type B1, 1:2:4 (20 mm graded aggregate)in cover slabs set in cement mortar 1:4 including all necessary form work. Exposed surfaces of concrete shall be finished even and smooth without using extra cement all as specified and directed. (Note : Reinforcement shall be measured and paid separately under relevant items of this schedule.

22.52

-

-

... More
Use & waste formwork to sides of pillars, posts, struts, piers, columns and stanchions all as specified and directed.

589.45

-

-

... More
Use & waste formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) all as specified and directed.

275.74

-

-

... More
M & L for PCC 1:4:8 type D2 (using 40 mm graded stone aggregate) in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for pipes of 150 mm bore all as specified and directed.

15

-

-

... More
Supply, laying, jointing and testing of Galvanized Iron (GI) pipe Heavy Class of size 65mm dia bore with all necessary fittings such as sockets, bends, tees, elbows, unions, nipples etc as per site requirement complete all as specified and directed.

2400

-

-

... More
S&F PVC floor trap of 75 mm outlet, jointing to waste pipe, complete all as specified and directed.

3

-

-

... More
M&L for prepared on of new steel surfaces of any description over 10 cm width or girth and applying to coat of synthetic enamel paint over a coat of red oxide primer all as specified and directed.

108.76

-

-

... More
S&F 75 mm bore PVC (SWR) bends of any radius, complete all as specified and directed.

2

-

-

... More
Supply and laying in replacement of un-reinforced precast concrete cable cover, class HVP, type 1 with peak, size 300mm x 180mm x 40mm for cable protection in trenches complete all as specified and directed.

2700

-

-

... More
M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified and directed.

53613.21

-

-

... More
M&L Forming construction (Dummy) joints 65mm deep x 10mm wide filled with sealing compound all as specified and directed.

70

-

-

... More
Supply and fix LED batten with CRCA sheet steel box type body pre-wired suitable for and including provision of 1x20/22 Watt (4 feet) retrofit LED tube with PC body, full white and connecting up with twisted three core flexible copper wire of 0.5sqmm from ceiling rose to connector of fitting complete all as specified and directed.

8

-

-

... More
Supply, installation, testing & commissioning of Hypo Dosing Pump consisting of metering type dosing pump for 1 LPH at 5 Kg/cm2, PP head and PVC fitting and HDPE dosing tank of 100 Liter capacity complete all as specified and directed. (01 Working + 01 Standby)

2

-

-

... More
M&L 5mm thick rendering in CM 1:3 on ceiling of concrete surface finished even and fair etc. complete all as specified and directed.

32.19

-

-

... More
(i) Bus bar: TPN copper bus bar of suitable rating provided with heat shrinkable coloured PVC sleeve insulation mounted on insulators for main bus bar and Continuous earth bus with GI strip of suitable size capable for carrying full short circuit current for 1 sec shall be provided at bottom of the panel. (ii) Incomer: (a) MCCB, 63 A, 4 Pole, 25 KA (Ics=100%Icu), 415 V, 50 Hz, with adjustable thermal - magnetic release - 01 No (b) Digital Voltmeter with selector switch - 01 Set. (c) Digital Ammeter with selector switch & suitable ratio of CT's - 01 set of 03 (d) LED Pilot light indication lamps for R,Y,B phases - 01 Set of 03 (iii) Outgoing:- (a) Motor Protection Circuit Breaker (MPCB), rotary type, 10 Amps, 3 Pole, 100 KA, with short circuit & overload protection along with Direct Online (DOL) starter suitable for up to 5 HP 3 ph, 415 V, 50 HZ, Sewage Submersible pump set along with LED pilot light indication lamps to indicate motor ON & OFF position - 03 Sets (b) MCB SPN 20 Amps, 10 KA, 'C' curve - 02 Nos.

-

-

-

... More
Supply, installation, testing & commissioning of Batch type Centrifuge Machine of capacity 25 Kg / Batch suitable to handle sludge generated from 0.174 MLD STP. Material of Construction for outer shell with 4mm thick Mild Steel, Perforated plate with 3mm thick Stainless Steel (SS 304 grade), Main Shaft with EN8, Base Frame with Mild Steel Channel, Boring housing with Cast Iron, Legs with Cast Iron, Dome nut with Forged Mild Steel with Stainless Steel lining, Filter Bag with Multi P.P. Bag, Basket with Stainless Steel (SS 304 grade) of size not less than 500mm dia X 280mm depth duly statistically and dynamically balanced complete belt driven with suitable capacity 3 phase, 415 Volts, 50 Hz Electric Motor but not less than 2.0 HP, including suitable pulley and 'V' belt for driving the machine complete all as specified and directed. (01 Working + 01 Standby)

2

-

-

... More
Material & Labour for Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all as specified and directed.

40

-

-

... More
Excavation over area, exc. 1.5 m deep but n exc 3.00 and getting out for Hard/ dense Soil all as specified and directed.

327.17

-

-

... More
Supply and fixing of Anti-climbing device; spikes type fabricated out of M.S. bars (round, square and flat) including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the pole complete all as specified and directed.

0.2

-

-

... More
S&F in replacement of angular stop cock 15 mm dia with wall flange made of cast copper alloy, chromium plated type, complete all as directed.

3

-

-

... More
Daily log sheets in proper format, attendance register and other stationery items, as required, for all installations will be provided by the contractor and the cost of the same is deemed to be included in the quoted rates only. In case Contractor fails to maintain the said documentation, a penal recovery @ Rs. 50.00 per shift shall be recovered from the Contractors dues.

-

-

-

... More
M&L for sub main wiring with 2runs x 4 sqmm(Ph & N) + 1run x 4 sqmm(earth wire, FRLS insulated copper conductor, single core cable drawn through and including medium grade rigid PVC conduit conforming to IS:9537 (Pt-III) and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 25mm concealed in wall/ floor etc complete all as specified and directed by Engineer-in-Charge. (Note: Three runs of copper cable and one run of PVC conduit shall be measured as one unit length)

15

-

-

... More
Supply, installation, testing and commissioning of Oil free Tri-lobe Air Blower suitable for not less than 168 M3/Hr of air delivery at a pressure of 0.65 Kg/Cm2 complete with 3 phase, 415 V, 50 Hz, TEFC (Totally Enclosed Fan Cooled) motor with IP55 degree of protection complete with and including Blower 3 lobe rotors, Electric Motor IE3, Supporting frame with discharge silencer, Filter and suction silencer, Belt drive with automatic tension, Safety valve, PVO valve, Non-return flap valve on discharge, Compensator, Pressure gauge on discharge, Outdoor canopy (Sound Enclosure) & Vacuum gauge etc complete as per OEM specifications.

2

-

-

... More
Diesel Engine : The diesel engine shall be of capacity suitable for alternator of capacity 62.5 KVA/50 KW developing required power for rated KVA not less than 59KW at 1500 RPM, 4 cylinders in-line, 4 stroke, radiator cooled, continuous duty with 10% overload capacity for any one hour in 12 hours of continuous running and consisting of following:- a) Radiator cooled b) Electrical Starter Motor 12V DC. c) 1No X 12 V battery, 90 AH rating with connecting leads and terminals d) Battery Charging Alternator e) Fuel System with electronic governor f) Full flow Spin-on lube oil filter g) Duel fuel filter with water separator h) Residential type silencer j) Dry type air cleaner k) Fly wheel and fly wheel housing l) First fill of lube oil & Coolant.

-

-

-

... More
S&F of 250mm long mild steel, sliding door bolt plate type, stove enamelled black, with bright bolt not less than 12mm dia with and incl minimum of 6 bolts and nuts, complete all as specified and directed.

4

-

-

... More
M&L for Cable jointing kit for 11 KV (Earthed) grade cable for outdoor end termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm complete all as specified and directed.

2

-

-

... More
Supply and fixing of Pin type, porcelain, vitreous, brown insulator including one galvanized mild steel spindle, two galvanized iron washers and one galvanized iron nut, 150mm height, 150mm dia for 11000 volts grade complete all as specified and directed.

6

-

-

... More
Supply and fix electronic fan regulator rotary type in 5 steps, 240V, 50Hz complete all as specified and directed.

3

-

-

... More
All as per item No. 193.00 here-in-before but of size 16 sqmm, 4 core.

100

-

-

... More
M&L for 100 mm thick Cement concrete B-1 1:2:4 (20 mm graded aggregate) complete all as specified and directed.

920

-

-

... More
S&F joist, channel, angle, or tee sections, fixed independtly, without connecting plates, etc all as specified and confirming to Fe-410-W (Gde E-250) Quality-A all as specified and directed.

960.12

-

-

... More
Providing and fixing SFRC (Steel fibre Reinforced Concrete) cover and frame (heavy duty HD-20 grade designation) 560 mm internal diameter confirming to IS-12592, total weight of cover and frame not less than 182 Kg fixed in cement concrete 1:2:4 type B-1 using 20mm garded stone aggregate complete all as specified and directed

77

-

-

... More
M&L for second class hard wood. Plain, solid, straight chowkhats and frame, wrought framed, rebated on the solid, rounded or chamfered, put together with glue, pinned at joints and fixing, complete all as specified and directed.

0.02

-

-

... More
M&L for earthing complete with galvanized iron earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level connecting to GI wire 4 mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel and earth wire protected by 15mm dia GI pipe medium grade and connected to distribution board/earthing test point all as shown in electrical plate No. 3 of SSR Part-I(2009) and testing on completion complete all as specified and directed. Note :- The unit rate quoted shall also include for excavation, earth work in any type of soil, plain cement concrete 1:3:6 mix, Type C1 pit, 40mm thick RCC 1:2:4 mix type B1 cover reinforced with 8mm dia TMT bras @ 150mm C/C both ways, GI funnel with watering pipe, wire mesh, protection pipe, earth wire up to 7.50m long complete in addition to item No. 1(a) to (e) of preamble (Notes) under sub heading earthing, specified in SSR Part II.

2

-

-

... More
Design, fabricate, supply, installation, testing and commissioning of Indoor Type cubicle panel board compartmentalized suitable for 3 phase 4 wire, 415 Volts, 50 Hz, AC supply system as per latest IS / IEC standards & regulations, factory fabricated in an approved factory having modern fabrication facilities, made out of CRCA sheet steel of 2mm thick with front and rear openable doors with locking facility. Complete panel board shall be applied with power coat painting of approved shade duly pretreated with seven tank process and suitable packing material for IP-54 degree of protection and including provision of 50mmx50mmx6mm angle iron base frame of suitable size for floor mounting the panel board with a minimum ground clearance of 300mm above FFL to the bottom of panel including PCC foundation with PCC 1:3:6, type C2 using 40mm graded stone aggregate. Detachable gland plates including double compression stainless steel cable glands of suitable size shall be provided for all incoming and outgoing cables. Steel plate Danger Notice Boards(02 Nos) LT 415/440 Volts, and manufacturer's name plate shall be riveted on external doors of feeder pillar box. The size of panel board shall suitable for accommodating and including provision of following switchgear, control gear and accessories including internal wiring with suitable gauge of copper cables complete all as specified and directed:- (Main control panel at STP pump house Bldg) Note: The Contractor shall submit set of all drawings of the L.T. Pillar Boxes and its components in duplicate and get the same approved from GE before commencement of production. The contractor shall furnish all details and clarifications required if any for scrutiny and evaluation. Manufacture of material to be supplied shall be done strictly as per approved drawing. However, approval of drawing shall not absolve the contractor/supplier of his liability for ensuring correctness according to applicable standards & regulations.

1

-

-

... More
Supply and fix Cast Iron Non Return Valve (NRV) of size 50mm NB with flanged ends swing type / ball type ISI marked including necessary packing material, bolts, nuts and washers complete all as directed.

9

-

-

... More
M&L for Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and incl joint plate nut Bolt etc; fixed with angle cleats or other connecting plates all as specified and directed.

603.42

-

-

... More
Supply, fixing, testing & commissioning of fine air bubble tubular diffuser of silicon having minimum dia 50 to 63mm and length 600mm to create fine bubble of 1 to 2mm dia with air flow rate as 4 to 5 M3/Hr at pressure of 0.65 Kg/Cm2 to be fitted in stainless steel air grid inside the MBBR tank tank complete all as specified and directed.

28

-

-

... More
Supply, installation, testing and commissioning of Non clog type Submersible Sewage Pump Set with single suction, stationary arrangement type suitable for 125 LPM discharge at a head of 10 meter along with suitable 3 phase, 415V, 50 Hz submersible motor complete with and including submersible cable and foundation as per the following detailed specifications:- (Location: Equalization Tank at STP) (01 Working + 01 Standby) (i) Pump Casing : Radially split casing type provided with delivery nozzle cast integral with it, axial suction and central and horizontal delivery nozzle, specially designed semi concentric casing to ensure vibration free performance and wide volute passage to ensure non clogging operation of the pump. (ii) Impeller : Impellers shall be of non clog type to allow smooth passage of solids with multi vanes in semi open with cutting and tearing arrangement. (iii) Shaft : Shaft shall be of high tensile steel supported by two ball bearings in the motor above the impeller and shall be designed to transmit the power without undue vibrations and deflections. The shaft shall be common for pump and motor of monoblock design. (iv) Mechanical Seal: Double mechanical seal with back to back arrangement to ensure no ingress of pumping liquid in the motor. (v) Bearings: Bearing shall be grease lubricated and sealed for maintenance free operation. (vi) Motor: Motor shall be of dry type submersible and cooled by liquid being handled. Motor shall be air tested for leak proof operation. Degree of protection for motor shall be IP 68 as per IS:2147. Motor shall be 3 phase, 415 Volts, 50 Hz with Class 'F' insulation of suitable rating as per manufacturer's design. (vii) Cable: Cable shall be of suitable size and specially designed with 1.1 KV grade, annealed tinned copper conductor, insulated with electron beam irradiated cross linked elastomeric compound, cores laid up with proof cotton binder tape and sheathed overall with electron beam irradiated cross linked HD HOFR (Heavy Duty, Heat, Oil, Fire Retardant) elastomeric compound and generally confirming to IS:9968. (viii) Foundation: RCC / PCC foundation at the bottom of sump as per manufacturer's recommendations. (ix) Accessories : Stand, Duck Foot Bend, Support Bracket, Guide Shoe, Guide Pipe Adapter, Chain for pulling the pump, Guide Pipe Holder, Guide Pipe Connector Unit, Cable Bracket, Hose Clip, Cable Gland and Potting Cup complete for single guide pipe design shall be supplied and fixed with pump set complete all as specified and directed.

2

-

-

... More
MANNING & OPERATION OF STP (PHASE-II WORK)

-

-

-

... More
Fuel Tank: Integral fuel tank shall be of capacity not less than 140 Liters and provided with drain plug, air vent, inlet and outlet connection, level indicator and provision for cleaning.

-

-

-

... More
M&L for Cable jointing kit for 11 KV (Earthed) grade cable for straight through termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm complete all as specified and as directed.

1

-

-

... More
M&L for machine cut Kota stone slab flooring 18-20 mm thick on the vertical surface/dado over and including 10mm thick CM rendering in CM (1:4) set and jointed with grey cement slurry mixed with pigment to match the shade of the slab, with and including Cutting / Griding / mirror Polishing on Kota stone as per local trade practice, complete all as specified and directed.

113.03

-

-

... More
Excavation in trenches n.exc 1.50 m wide and exc 4.50 m and n.exc 6.00 m depth for foundation n.exc. 10 sqm on plan and getting out in Hard/ dense soil from sewage line etc, all as specified and as directed.

20.06

-

-

... More
M&L for brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in Cement Mortar 1:4 all as specified and directed.

51.75

-

-

... More
M&L for box type steel ventilator with 80x40x1.25mm MS tubular frame partly gauged with top hung shutter with and incl grill using 12mm square bars @ 10Cm C/C incl box type hinges with steel handle and steel pag stay complete glazing bars dovetailed and welded complete all as specified as directed. Note:- (a) The Glass / gauze shell be measured and paid separately. (b) Top hung Z-Section shutter shall be of size 20mm x 20mm x 25mm and 0.3mm thick.

0.72

-

-

... More
Supply and fix ceiling fan, 1200mm sweep, 3 blade, white colour, energy efficient, 50W / 52W power cosumption, minimum 310 RPM, 100% copper winding motor with and including down rod, canopy (02 Nos), GI fan clamp with rubber bush, GI nuts, bolts and split pins etc (without regulator) and connecting up with 3 core x 0.5 sqmm flexible copper conductor cable from ceiling rose to connector of fan complete all as specified and directed.

3

-

-

... More
S&F for 18/16 mm thick veneered particle board, interior grade, solid core, medium density general purposes type with decortive face veneers type 'BB all as specified and directed.

2.1

-

-

... More
M&Lfor RCC (Design Mix) M-30( using 20 mm graeded aggregate as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete all as specified and directed.

279.97

-

-

... More
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm all as specified and directed.

3789.2

-

-

... More
S&F of 600x450mm size and 4mm thick beveled edge looking mirror of selected quality glass, having PVC moulding/beading all around, mounted on 4mm thick PVC board, with and incl fixing accessories, complete all as specified and directed.

1

-

-

... More
The contractor shall maintain sufficient quantity of safety equipments such as hand gloves, gum boots, torch lights at all the installations for use by the operating staff employed under this contract and cost of this provision is deemed to be included in the quoted rate.

-

-

-

... More
S&F in replacement of long body bib cock, 15 mm dia with wall flange made of cast copper alloy, chromium plated, complete all as directed.

3

-

-

... More
Supply and spreading of M-sand in trenches for cushioning of cable complete all as specified and directed. (Note: Punned down thickness only shall be measured for the purpose of payment)

35

-

-

... More
S&F 110 mm bore PVC (SWR) bends of any radius, complete all as specified and directed.

3

-

-

... More
Supply, laying, jointing and testing of Galvanized Iron (GI) pipe Heavy Class of size 50mm dia bore with all necessary fittings such as sockets, bends, tees, elbows, unions, nipples etc as per site requirement complete all as specified and directed.

250

-

-

... More
Supply and fix in replacement of 40mm NB, Stainless Steel (SS) 304, SCH 10 seamless pipe for coarse bubble air grid for MBBR tank and equalization tank as per site requirement and OEM design complete all as specified and directed.

30

-

-

... More
The shut down period of the plant for carrying out any kind of repairs / maints will be jointly decided by Engineer-in-Charge and the contractor.

-

-

-

... More
Supply, laying, jointing and testing of Galvanized Iron (GI) pipe Heavy Class of size 25mm dia bore with all necessary fittings such as sockets, bends, tees, elbows, unions, nipples etc as per site requirement complete all as specified and directed.

150

-

-

... More
S&F M&L Stainless Steel Frame work such as grill, garting etc (verticle frame supprot signage boards) with ends of bars shouldered an/ or riveted or forged in to spikes, railings, ladders and similar works confirmimg to type-304 or type-316 complete as specified and directed.

856.36

-

-

... More
Acoustic Enclosure: The entire generator, prime mover, fuel tank and DG set control panel should be housed in a sound proof acoustic enclosure made of CRCA sheets with UV resistant powder coated and a structural/sheet metal base frame. The walls of the enclosure should be insulated with high quality noise absorbent and fire-retardant grade acoustic insulation material complying to IS 8183 for better sound attenuation so as to comply with the 75 dBA at 1 meter sound levels at 75% load under free field conditions as specified by MOEF/CPCB. The enclosure should be provided with the following:- (i) Suitable doors on all sides to enter in to the container for easy maintenance. All doors shall be provided with locks and handles for opening/ closing of doors. (ii) Suitable internal lighting to carry out easy inspection and maintenance. (iii) Air Inlet louvers designed to operate at rated load. (iv) Fluid drains for lube oil and fuel. (v) Fuel filling point with locking arrangement. (vi) Push button for emergency stop

-

-

-

... More
M&L for Non skid ceramic colored tiles of size 300x300mm, 7 to 8 mm thick (square / rectangular) as in flooring etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed/ bedding layer in CM (1:6) complete all as specified and as directed.

5.4

-

-

... More
M & L for construction of septic tank for 10 users, including excavation in any type of soil complete all as specified On site Hume Pipe septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, Vent shaft, connection etc., complete all as specified and directed.

1

-

-

... More
Supply, installation, testing and commissioning of Centrifugal monoblock water pump with CI casing, bronze impeller, high tensile steel shaft, with mechanical seal complete suitable for 125 LPM discharge at a head of 10 meters coupled with suitable AC 3 Phase, 415 V, 50 Hz, TEFC squirrel cage induction motor with IP 55 degree of protection and Class 'B' insulation but capacity of motor shall not be less than 1 HP complete with and including MS base frame with anti-vibration mounting pads on suitable PCC foundation as per manufacturer's recommendations complete all as specified ad directed. (Pumping to Oxidation Pond / Nallah)) (01 Working + 01 Standby).

2

-

-

... More
Supply, connecting & testing of Flat Three Core 2.5 sqmm PVC Insulated & PVC Sheathed Industrial Cable for Submersible Pump Motors 1100 Volts grade, conforming to IS: 694 complete all as specified and directed.

90

-

-

... More
Supply and fix switch piano flush type 6 Amps, one way, 240V, 50Hz complete all as specified and directed.

32

-

-

... More
M&L for Cutting opening in cement concrete / brick walls (any description) in round shape 300 mm dia for exhaust fan, including trimming surfaces to receive rendering and finishing with cement plaster, putty and paint to match with existing wall colour complete all as specified and directed.

5

-

-

... More
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in any type of soil all as specified and directed.

983.84

-

-

... More
M&L for RCC (Design Mix) M-25 ( using 20 mm graeded aggregate as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like all as specified and directed.

0.99

-

-

... More
Design, fabricate, supply, installation, testing and commissioning of Outdoor Type cubicle panel board compartmentalized suitable for 3 phase 4 wire, 415 Volts, 50 Hz, AC supply system as per latest IS / IEC standards & regulations, factory fabricated in an approved factory having modern fabrication facilities, made out of CRCA sheet steel of 3mm thick for outer shell and 2mm thick for inner shell with front and rear openable double leaf doors with two point locking arrangement i.e. locking system with handle up & down arrangement & pad-locking facility. Complete panel board shall be applied with power coat painting of approved shade duly pretreated with seven tank process and suitable packing material for IP-54 degree of protection and including provision of 50mmx50mmx6mm angle iron base frame of suitable size for mounting the panel board with a minimum ground clearance of 450mm above GL to the bottom of panel including PCC foundation with PCC 1:3:6, type C2 using 40mm graded stone aggregate. Detachable gland plates including double compression stainless steel cable glands of suitable size shall be provided for all incoming and outgoing cables. Steel plate Danger Notice Boards(02 Nos) LT 415/440 Volts, and manufacturer's name plate shall be riveted on external doors of feeder pillar box. The size of panel board shall not be less than 1200mm x 1200mm x 400mm (outer dimensions) for accommodating and including provision of following switchgear, control gear and accessories including internal wiring complete:- (Transformer main panel) (Note: The Contractor shall submit set of all drawings of the L.T. Pillar Boxes and its components in duplicate and get the same approved from GE before commencement of production. The contractor shall furnish all details and clarifications required if any for scrutiny and evaluation. Manufacture of material to be supplied shall be done strictly as per approved drawing. However, approval of drawing shall not absolve the contractor/supplier of his liability for ensuring correctness according to applicable standards & regulations.

1

-

-

... More
Supply and fix MCB distribution board, SPN, 8 way in sheet steel powder painted enclosure double door type with minimum IP 43 degree of protection with built in copper bus bar, neutral link and earth link complete including cutting the wall surfaces for flush mounting of DB and making good with cement plaster, putty and paint to match with the existing surface complete all as specified and directed. Note: MCBs shall be measured and paid separately.

1

-

-

... More
Material and labour for M.S. Black Pipe plain end as per IS:1239 (I), nominal bore 40 mm dia, 'C' class with all fittings including cutting, welding and joining etc as per site requirement and applying two coats of synthetic enamel paint of approved colour over a coat of red oxide primer complete all as specified and directed complete all as specified and directed.(For compressed air from air blower to MBBR and equalization tank).

30

-

-

... More
Excavation over area, exc. 6.00 m deep but n exc 7.50 and getting out for Hard/ dense Soil all as specified and directed.

64.48

-

-

... More
Supply and fix ceiling rose 6 Amps, 3 plate, 240V, 50Hz complete all as specified and directed.

17

-

-

... More
The cost of removal of sludge from site and disposal of the same outside defence land as per local civil authorities laid down rules is deemed to be included in quoted rates and no extra payment will be made in this effect at any stage.

-

-

-

... More
M&L for 75 mm PCC 1:3:6 type C-1 using 20mm graded stone aggregate as in plinth protection and path laid in alternate panels not more than 3 mtr in length, laid to slope 1:30 including forming joints 10 mm wide and upto full depth of PCC and filled with bitumen mastic (1:3) 1 part bitumen 85/25 and 3 parts of sand complete all as specified and directed.

69.78

-

-

... More
Supply and fix Lamp holder, angle type with metal ring, PVC/Polycarbonate body including supply and fix of 7 watt LED bulb complete all as specified and directed.

2

-

-

... More
S&F Polymer Encapsulated iron Ladder of 3.95 m long having 0.45 m long step all as specified and directed.

2

-

-

... More
Supply and fix Cast Iron sluice valve of size 80mm NB, having pressure rating PN 1.6, double flanged, non-rising stainless steel spindle with iron wheel complete as per IS:14846 and all as specified and directed.

5

-

-

... More
M&L for Brickwork with fly ash bricks, straight or curved on plan exc 6 m mean radius, built in CM 1:6 all as specified and directed.

189.05

-

-

... More
All as per item No. 1 here-in-before but suitable for 145 LPM discharge at a head of 25 meter. (Location: Raw Sewage Collection Sump - 1 near Offrs Md Accn) (02 Working + 01 Standby)

3

-

-

... More
M&L for Hardcore of gauge n exc. 63 mm Broken stone or boulders, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface all as specified and directed.

149.99

-

-

... More
S&F of aluminium alloy anodized sliding door bolt 200 mm length with hasp staple and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all specified and directed.

2

-

-

... More
Supply and fixing of Disc type insulator, porcelain, vitreous 145mm high and 255mm dia ball and socket type, brown, single disc assembly for tension with tension clamps for conductors, working pressure 11000 volts complete all as specified and directed.

6

-

-

... More
Supply and fix switch piano flush type 16 Amps, one way, 240V, 50Hz complete all as specified and directed.

4

-

-

... More
S&F of stainless steel wire cloth 0.36 mm in nominal dia of wire average width of aperture 1.40 mm and fixed with tinned tacks of stainless steel wire staples to steel shutters or fixed with wooden beads to wooden joinery, complete all as specified and directed.

14

-

-

... More
M&L for preparing newly plastered surfaces of walls and applying three coats of white wash complete all as specified and directed.

18.7

-

-

... More
AMF Panel : AMF Panel of the DG set can be located inside the acoustic enclosure or outside the acoustic enclosure as per manufacturer's standard. The AMF panel shall be totally enclosed, dust, damp and vermin proof, cubicle type free standing floor mounted type made out of 1.6mm/2.0mm thick CRCA sheet for the panel located inside the acoustic enclosure. If the AMF panel has to be located outside the acosustinc enclosure, the outer shell of the panel should be made out of 3mm thick CRCA sheet and provided with a canopy and the degree of protection shall be IP 54. The AMF Panel should be equipped with the follwoing control gear and components:- (a) Power contactor-3/4 pole of suitable current rating with thermal overload relay - 02 Nos (for alternator and mains) (b) MCB / HRC fuse of suitable current rating for short circuit protection (c) Microprocessor based AMF module incorporating functions:- - Supply failure timer - Restoration timer - 3 Impulse automatic engine start/ stop logic - Mains/ Generator Voltage & Frequency sensing (d) Aluminium bus bars of suitable capacity with incoming/ outgoing terminals (e) Instrument fuses duly wired and ferruled (f) MCCB of suitable rating 3/4 pole with overload and short circuit protections - 02 No's (for alternator & mains) (g) Current Transformers of suitable rating (h) Microprocessor based generator set monitoring and control system with LCD display integrated with all Features, Functions and Protections of Engine and Alternator provided with separate LED indication lamps for each. (i) Auto/Manual selector provision

-

-

-

... More
M&L for RCC (Design Mix) M-25 (using 20mm graded aggregate) Walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilasters and buttresses all as specified and directed.

124.39

-

-

... More
Material & Labour for Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all as specified and directed.

20

-

-

... More
The operator should be free from the habits of any addiction such as liquor, smoking or other drugs. If, any person, declared un-desirable by the Garrison Engineer, will be replaced by the contractor within 15 days and contractor will have no claim what so ever on this account.

-

-

-

... More
M&L for Moorum/Red bajri, spread, rolled and consolidated to gradient and camber required all as specified and directed.

50.96

-

-

... More
Material and labour for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paint complete all as specified and directed.

2

-

-

... More
Supply, installation, testing and commissioning of Activated Carbon Filter complete with pressure vessel in mild steel construction of size 800mm dia and 1875 mm height suitable for flow rate of 135 LPM for working pressure 1.8 Kg/Cm2 (Min) to 3.5 Kg/Cm2 (Max) including supply and fixing of frontal pipe work, all control valves, first fill of activated carbon filter media for 1000 mm depth, PCC foundation complete all as per manufacturer's specifications / recommendations.

1

-

-

... More
M&L for 10 mm thick rendering in cement morter (1:4) mixed with water proofing compound @ 0.20 Ltr/bags on roof surface when concrete is green, complete all as specified & directed (Note: WPC shall be measured and paid separately)

168.73

-

-

... More
M&L for ceramic colour tiles in vertical surface of size 450 X 300 x 7 mm thick, jointless type, set and jointed in neat cement slurry and pointed in white or coloured cement to match tiles with and including 10 mm thick rendering in CM (1:4) for receiving the tiles, complete all as specified and directed.

27.72

-

-

... More
Supply and fixing of Lightning arresters expulsion type complete with all fittings, distribution class of discharge capacity 10 kilo amp suitable for 11 Kilo Volts complete all as specified and directed.

2

-

-

... More
Supply, connecting & testing of 4 core, 1.5 sqmm power cable with copper conductor, PVC insulated, Cores laid up, PVC Inner sheathed, Armoured with galvanized wire or galvanized steel strip, overall PVC Sheathed, 1100V Grade as per IS IS 1554 Part-1 including taking out of existing unserviceable cable of any description complete all as specified and directed complete all as specified and directed.

50

-

-

... More
Excavation over area, exc. 3.00 m deep but n exc 4.50 and getting out for Hard/ dense Soil all as specified and directed.

112.71

-

-

... More
Supply only integral liquid water proofing compound, mixed in cement morter as per manufacturer instruction, complete all as directed.

10

-

-

... More
Supply and fixing of 11000 volts grade, expulsion type drop out fuse set mounted on 06 insulators and steel frame for current rating up to 25 Amps complete all as specified and directed.

2

-

-

... More
Supply, installation, testing and commissioning of step down transformer out door type suitable for plinth mounting complete with standard accessories/fittings suitable for HT 11KV 3 Phase and LT 433 volts 3 phase 4 wire ,copper wound ,with off load tap changer having voltage variation of +5% to -10% in step of 2.5 % continuous rating of capacity 100 KVA with temperature rise shall not exceed 45° C for transformer winding and 40° C for top oil complete conforming to IS 1180 (Part 1) : 2014 Energy Efficiency Level - 2 and equipped with and including following fittings :- (a) Two earthing terminals for body earthing and two additional for neutral brought out on a bushing. (b) Lifting lugs/hooks . (c) Rating and terminal marking plate. (d) Silica gel breather . (e) Drain - cum - sampling valve (3/4)" nominal thread with plug (f)Thermometer pocket. (g) Oil filling inlet pipe with plug. (h) Conservator with oil level gauge. (j) First fill of oil up to appropriate level as recommended by manufacturer with fresh new oil. (k) Type of connection arrangement : MS cable termination box on LT side and open bushing on HT side.

1

-

-

... More
Supply and fixing of 70 Watt LED street light fitting made up of Pressure die-cast aluminium alloy housing with toughened glass, IP66 protection and impact resistance of IK07 and individual high power LEDs with secondary optics having system lumen efficacy ≥100 lm/W, Inbuilt potted electronic LED driver with APFC (SMPS based constant current supply), lower THD, Open Circuit protection, Over Voltage protection, Surge Voltage protection & other safety test as per IS 15885 Part-2/Sec 13 and BIS complying complete all as specified and directed.

10

-

-

... More
Material and labour for earthing complete with galvanized iron earth plate electrode 600mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level connecting to GI strip of size 32 x 6mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel and earth strip protected by 50mm dia GI pipe medium grade and connected to DG Set / Panel Board all as shown in electrical plate No. 3 of SSR Part-I(2009) and testing on completion complete all as specified and directed. Note :- The unit rate quoted shall also include for excavation, earth work in any type of soil, plain cement concrete 1:3:6 mix, Type C1 pit, 40mm thick RCC 1:2:4 mix type B1 cover reinforced with 8mm dia TMT bras @ 150mm C/C both ways, GI funnel with watering pipe, wire mesh, earth lead & protection pipe up to 7.50m long complete in addition to item No. 1(a) to (e) of preamble (Notes) under sub heading earthing, specified in SSR Part II.

26

-

-

... More
M&L for 75mm thick cement concrete type D-2, 1:4:8 (40mm graded aggregate), complete all as specified and directed.

6.61

-

-

... More
S&F Stairs (framed) including stringers, treades, landing, balusters, hand rails, railing , MS leader etc. including cleats, brackets, etc. complete Fe 410-W(Gde E-250) quality-A all as specified and directed.

162.72

-

-

... More
M&L for precast RCC (1:2:4) 20mm aggregated cover for mainhole all as specified and directed.

0.07

-

-

... More
S&F of rotational moulded polyethylene cylindrical vertical with closed top water storage tank triple layered WHITE COLOUR 1000 Ltr capacity with connecting nipple, hoisted and fixed in position on new or existing foundation and making GI tubing inlet or outlet connection, with and incl disconnecting and dismantling the existing un-serviceable PVC/RCC water tank on top of roof/slab of bldgs, complete all as specified and directed.

1

-

-

... More
S&F 110 mm bore PVC (SWR) junction single (Single `T') equal or unequal, complete all as specified and directed.

2

-

-

... More
Supply and fix MCB 40A, 10 KA, SPN, 'C' curve, 240 V, 50 Hz complete all as specified and directed.

1

-

-

... More
Any damage made to STP installations due to negligence of staff employed by contractor that shall be made good by the contractor at his own cost.

-

-

-

... More
S&F of 3 mm thick sheet glass ordinary quality and glazing type, not exc 0.50 sqm in each pane, duly fixed with oil putty or wooden bidding as required, complete all as directed.

12.28

-

-

... More
Design, fabricate, supply, installation, testing and commissioning of Outdoor Type cubicle panel board compartmentalized suitable for 3 phase 4 wire, 415 Volts, 50 Hz, AC supply system as per latest IS / IEC standards & regulations, factory fabricated in an approved factory having modern fabrication facilities, made out of CRCA sheet steel of 3mm thick for outer shell and 2mm thick for inner shell with front and rear openable double leaf doors with two point locking arrangement i.e. locking system with handle up & down arrangement & pad-locking facility. Complete panel board shall be applied with power coat painting of approved shade duly pretreated with seven tank process and suitable packing material for IP-54 degree of protection and including provision of 50mmx50mmx6mm angle iron base frame of suitable size for floor mounting the panel board with a minimum ground clearance of 300mm above FFL to the bottom of panel including PCC foundation with PCC 1:3:6, type C2 using 40mm graded stone aggregate. Detachable gland plates including double compression stainless steel cable glands of suitable size shall be provided for all incoming and outgoing cables. Steel plate Danger Notice Boards(02 Nos) LT 415/440 Volts, and manufacturer's name plate shall be riveted on external doors of feeder pillar box. The size of panel board shall suitable for accommodating and including provision of following switchgear, control gear and accessories including internal wiring with suitable gauge of copper cables complete all as specified and directed:- (For Raw Sewage Collection Sump 1 & 2) Note: The Contractor shall submit set of all drawings of the L.T. Pillar Boxes and its components in duplicate and get the same approved from GE before commencement of production. The contractor shall furnish all details and clarifications required if any for scrutiny and evaluation. Manufacture of material to be supplied shall be done strictly as per approved drawing. However, approval of drawing shall not absolve the contractor/supplier of his liability for ensuring correctness according to applicable standards & regulations.

2

-

-

... More
Supply, installation, testing and commissioning of Progressive Cavity Screw Pump for pumping sludge from sludge holding tank (sludge having concentration of 5%) to centrifuge machine suitable for sludge discharge of 0.25 M3/Hr at a head of 30 meters and differential pressure of 3.0 bar, continuous duty with 330 RPM complete belt driven with suitable capacity 3 phase, 415 Volts, 50 Hz, 1440 RPM, IP:55, TEFC Electric Motor but not less than 0.75 HP, including suitable pulley and 'V' belt with guard for driving the pump complete mounted on MS fabricated common base plate all as specified and directed. (01 Working + 01 Standby).

2

-

-

... More
Outsourcing of services for operation and maintenance of Sewage Treatment Plant (STP) Installation of capacity 174 KLD comprising of Raw Sewage Pumps, MBBR reactors, Air Blowers, Tube Settler, Sludge Pumps, Centrifuge Machine, Chlorine Dosing Pumps, Filter feed pumps, Sand Filter and Activated Carbon Filter, Standby DG Set, Electric Control Panel, Starters, Cables, Various Control Valves, Sludge Drying Beds and all other connected equipment etc including pumping the Raw Sewage from Sewage Collection sumps located within the Avn Sqn area for round the clock operation in 03 shifts of 08 hrs each in every 24 hrs including Sunday and holiday (i.e. from 0600 hours to 1400 hours, 1400 hours to 2200 hours, 2200 hours to 0600 hours), to ensure uninterrupted and efficient functioning of STP to its designed parameters of treated water by employing 01 (one) Operator in each shift and 01 (one) helper in each shift in general shift (i.e 0900 hrs to 1700 hrs) complete all as directed.

24

-

-

... More
S&F factory made solid PVC moulded door shutter 28 to 30mm thick (Stiles) with 2, 4 or 6 raised panel design with 2mm thick Wooden texture moulded PVC sheet on the front face and 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification and drawing, complete all as specified and directed.

3.15

-

-

... More
S&F 75 mm bore PVC (SWR) junction single (Single `T') equal or unequal, complete all as specified and directed.

2

-

-

... More
Supply and fix Gun-metal, globe or gate valve of size 50mm NB, with iron wheel head, screwed both ends for iron pipe complete all as specified and directed.

2

-

-

... More
Supply and fix Gun-metal, globe or gate valve of size 25mm NB, with iron wheel head, screwed both ends for iron pipe complete all as specified and directed.

10

-

-

... More
Supply, connecting & testing of 3 core, 6 sqmm power cable with aluminium conductor, PVC insulated, Cores laid up, PVC Inner sheathed, Armoured with galvanized wire or galvanized steel strip, overall PVC Sheathed, 1100V Grade as per IS IS 1554 Part-1 including taking out of existing unserviceable cable of any description complete all as specified and directed complete all as specified and directed.

180

-

-

... More
The contractor will submit the name of all the deployed tradesman / workers along with their qualification, AADHAR CARD, police verification and other necessary documents as mentioned in PS within Twenty (20) days from the date of commencement of Phase-II (A) work. If, contractor fails to submit complete documents, a penal recovery of Rs 1000.00 (One Thousand only) per day will be recovered from the Contractors dues from date of commencement of Phase-II work.

-

-

-

... More
The operator/duty staff should not leave the installations till the next reliever does not take the charge of installation. Penal recovery @ Rs 1000/- per shift per operator, shall be made for full shift if Operator remains absent/leaves installation unattended & will be deducted from contractor’s dues. In case of any break down / defect(s), the duty staff / operator will report to concerned JE E/M or Engr-in- charge immediately. If, no report of break down / defect(s) is received and plant/installation is kept off, it will be assumed as absence of operator & penal recovery will be made as mentioned above. Contractor will not be admissible to claim for that shift for which penal recovery shall be made.

-

-

-

... More
The operator/duty staff shall be provided with proper uniform and shoes by the contractor as decided by the Engineer-in-Charge and operator shall wear them while on duty. The cost of this provision is deemed to be included in the quoted rate. In case operator do not maintain uniform on duty, a penal recovery @ Rs. 50.00 per operator per shift shall be recovered from contractor’s dues.

-

-

-

... More
M&L for cement concrete type B-1, 1:2:4 using 20 mm graded stone aggregate as in coping & in bedding & haunching against the side of wall of manholes complete all as specified and directed.

30.14

-

-

... More
Supply, installation, testing and commissioning of Multigrade Sand Filter complete with pressure vessel in mild steel construction of size 800mm dia and 1875 mm height suitable for flow rate of 135 LPM for working pressure 2.0 Kg/Cm2 (Min) to 3.5 Kg/Cm2 (Max) including supply and fixing of frontal pipe work, all control valves, first fill of sand filter media for 915 mm depth, PCC foundation complete all as per manufacturer's specifications / recommendations.

1

-

-

... More
Supply and fix Cast Iron sluice valve of size 65mm NB, having pressure rating PN 1.6, double flanged, non-rising stainless steel spindle with iron wheel complete as per IS:14846 and all as specified and directed.

7

-

-

... More
M&L Rendering 10 mm thick in cement mortar 1:4 on brick or concrete surfaces finished even and smooth with out using extra cement all as specified and directed.

300

-

-

... More
M&L for 15 mm thick rendering in CM (1:6) on fair/other than fair faces of brick work finished even and fair complete all as specified and directed.

231.36

-

-

... More
Supply, laying, jointing and testing of Galvanized Iron (GI) pipe Medium Class of size 25mm dia bore with all necessary fittings such as sockets, bends, tees, elbows, unions, nipples etc as per site requirement complete all as specified and directed.

100

-

-

... More
In case, additional manpower other than mentioned in Sch ‘A’ is required for attending any break down or in any emergency or to maintain the installations to the inspection standards etc , the contractor shall be solely responsible for providing the same without any extra cost and no extra payment will be made to this affect.

-

-

-

... More
Supply and erection of Hot dip galvanized tapered octagonal pole of height 7.0 mtrs in single or double section having top dia 70mm and bottom dia 130mm made up of 3mm thick sheet and welded with a base plate of size 200mm x 200mm x 12mm thick and provided with 1000mm long single arm bracket with 15 degree of angle for mounting street light fitting complete with provision of 04 Nos of ‘J’ type foundation bolts of size not less than 20mm dia, 600mm long embedded in RCC foundation concrete as per manufacturer’s recommendation including necessary earth work, RFR etc complete. A door should be provided at a height of 500mm from the base plate for accommodating and including provision of TPN aluminium bus bar system suitable for connecting up to 2 core, 10 sqmm aluminium cable and 01 No. of 6A SP MCB for street light protection inside the pole shaft including provision of 3 core, 1.50 sqmm PVC insulated PVC sheathed copper conductor cable 1100 volts grade confirming to IS:694 from pole junction box to street light fitting drawn through inside of pole . Radium reflector band / strips of 5cm wide in Green (02 Nos) & White (01 No.) colour shall be provided at a height of 1.25mtr from base plate. Numbering of pole shall be done in black colour on yellow background at suitable place on the pole complete as specified and directed. Note: The quoted rate shall deemed to be inclusive of RCC foundation concrete, necessary excavation, erth work & RFR etc complete as per manufacturer's recommendation. Contractor shall submit the pole drawing and foundation drawing as per manufacturer's recommendation for approval of GE before procurement.

10

-

-

... More
Supply and fix exhaust fan, 300mm sweep with 04 Nos of blade leafs, 70 W power consumption, 1300 to1400 RPM, 100 % copper winding heavy duty motor with double ball bearings including supply and fixining of metallic louvers and connecting up with 3 core x 0.5 sqmm flexible copper conductor cable from ceiling rose to connector of fan complete all as specified and directed.

5

-

-

... More
The provision of statutory laws relating to Minimum Wages, EPF and ESIC Payments shall be strictly adhered to by the Contractor and quoted rate is deemed to be inclusive of all these factors.

-

-

-

... More
Supply, connecting & testing of Flat Three Core 4.0 sqmm PVC Insulated & PVC Sheathed Industrial Cable for Submersible Pump Motors 1100 Volts grade, conforming to IS: 694 complete all as specified and directed.

50

-

-

... More
S&F in replacement of 1st quality vitreous china wash hand basin, white flat/angle back, size 550x400mm, complete including necessary cutting for and pinning in ends of brackets) with and including wall brackets, PVC waste pipe of 750mm long, CP waste coupling of 32mm dia size, complete all as specified and directed.

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Related Tenders

Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.