Military Engineer Services Tender

... More
The MES has issued a formal invitation for competitive bids for the Military Engineer Services project, for Repair And Maint Of Split Window Air Conditioner And Water Cooler Refrigerator, Deep Freezer And Desert Cooler At Technical Area At Afs Chakeri Kanpur in Kanpur Nagar, Uttar Pradesh, with an estimated contract value of Rs. 50,00,000. The bid opening date for this tender is 27-10-2026 and the last date for bid submission is 17-11-2026. Interested bidders for Military Engineer Services tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.

Military Engineer Services - MES Tender - UP Tender

Opening Date27 Oct 2026
Closing Soon17 Nov 2026
Tender Amount₹ 50,00,000 
Notes
Download

Costs

Description

Repair And Maint Of Split Window Air Conditioner And Water Cooler Refrigerator, Deep Freezer And Desert Cooler At Technical Area At Afs Chakeri Kanpur

Contact

Unlock the Tender details

GEM & Bid Advisory Services

Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

Unlock the Tender details
... More
Supply only of running capacitor 1.5 µF, complete all as specified and directed by Engineer-in-Charge.

40

53

-

... More
Supply only of running capacitor 2.5 µF, complete all as specified and directed by Engineer-in-Charge.

50

10

-

... More
Supply only of running capacitor 4 µF, complete all as specified and directed by Engineer-in-Charge.

50

-

-

... More
Supply only of running capacitor 6 µF, complete all as specified and directed by Engineer-in-Charge.

50

100

-

... More
Supply only of running capacitor 36 µF, complete all as specified and directed by Engineer-in-Charge.

60

53

-

... More
Supply only of running capacitor 45+6 µF, complete all as specified and directed by Engineer-in-Charge.

130

-

-

... More
Supply only of running capacitor 50+6 µF, complete all as specified and directed by Engineer-in-Charge.

120

100

-

... More
Supply only of running capacitor 55+6 µF, complete all as specified and directed by Engineer-in-Charge.

120

53

-

... More
Supply only of starting relay suitable for air conditioner of capacity 1.5/2.0/3.5 TR, complete all as specified and directed by Engineer-in-Charge.

40

10

-

... More
Supply only of thermostat switch with knob suitable for window type air conditioner, complete all as specified and directed by Engineer-in-Charge.

50

-

-

... More
Supply only of contactor relay for split/tower type air conditioner of capacity up to 3.5 TR, 2 pole for single phase 230 V split type air conditioner or 3 pole for three phase 415 V tower type air conditioner, 50 Hz, current rating and coil voltage as per existing, complete all as specified and directed by Engineer-in-Charge.

80

100

-

... More
Material and labour for disconnecting unserviceable PCB from the unit of split/window type air conditioner, transporting to market for repair/replacement of defective parts required to make it serviceable, reinstalling in the unit and making connections, complete all as specified and directed by Engineer-in-Charge.

100

53

-

... More
Material and labour for disconnecting unserviceable PCB from the unit of inverter type split/window type air conditioner, transporting to market for repair/replacement of defective parts required to make it serviceable, reinstalling in the unit and making connections, complete all as specified and directed by Engineer-in-Charge.

50

-

-

... More
Supply and fixing in replacement of MCB SP, 240 V, 20 A, C curve, 10 kA breaking capacity, conforming to IS/IEC 60898-1, complete all as specified and directed by Engineer-in-Charge.

30

100

-

... More
Supply and fixing in replacement of metal clad industrial type socket, 2 pin and earth, 20 A, 230 V, suitable for AC box, complete all as specified and directed by Engineer-in-Charge.

70

53

-

... More
Supply and fixing in replacement of metal clad industrial type plug top, 2 pin and earth, 20 A, 230 V, suitable for AC box, complete all as specified and directed by Engineer-in-Charge

70

10

-

... More
Supply only of non-return valve suitable for window/split type air conditioner of capacity 1.5/2 TR, complete all as specified and directed by Engineer-in-Charge.

50

-

-

... More
Supply and fixing in replacement of flare nut 3/4 inch, complete all as specified and directed by Engineer-in-Charge.

10

100

-

... More
Supply and fixing in replacement of flare nut 5/8 inch, complete all as specified and directed by Engineer-in-Charge.

60

53

-

... More
Supply and fixing in replacement of flare nut 3/8 inch, complete all as specified and directed by Engineer-in-Charge.

10

-

-

... More
Supply and fixing in replacement of flare nut 1/2 inch, complete all as specified and directed by Engineer-in-Charge.

80

100

-

... More
Supply and fixing in replacement of flare nut 1/4 inch, complete all as specified and directed by Engineer-in-Charge.

100

53

-

... More
Supply and fixing in replacement of dead nut 3/4 inch, complete all as specified and directed by Engineer-in-Charge.

10

10

-

... More
Supply and fixing in replacement of dead nut 5/8 inch, complete all as specified and directed by Engineer-in-Charge.

50

-

-

... More
Supply and fixing in replacement of dead nut 3/8 inch, complete all as specified and directed by Engineer-in-Charge.

10

100

-

... More
Supply and fixing in replacement of dead nut 1/2 inch, complete all as specified and directed by Engineer-in-Charge.

60

53

-

... More
Supply and fixing in replacement of dead nut 1/4 inch, complete all as specified and directed by Engineer-in-Charge.

60

-

-

... More
Supply and fixing in replacement of suction valve 3/4 inch, complete all as specified and directed by Engineer-in-Charge.

10

100

-

... More
Supply and fixing in replacement of suction valve 5/8 inch, complete all as specified and directed by Engineer-in-Charge.

60

53

-

... More
Supply and fixing in replacement of suction valve 1/2 inch, complete all as specified and directed by Engineer-in-Charge.

80

10

-

... More
Supply and fixing in replacement of discharge valve 3/8 inch, complete all as specified and directed by Engineer-in-Charge.

10

-

-

... More
Supply and fixing in replacement of discharge valve 1/4 inch, complete all as specified and directed by Engineer-in-Charge.

80

100

-

... More
Supply only of overload protector relay suitable for air conditioner of capacity 1.5/2.0 TR, complete all as specified and directed by Engineer-in-Charge.

80

53

-

... More
Supply only of copper liquid line filter, 3 way, suitable for copper pipe of 3/8 inch diameter for window/split type air conditioner, complete all as specified and directed by Engineer-in-Charge.

50

-

-

... More
Supply and fixing in replacement of copper pipe 5/8 inch outer diameter, conforming to IS 10773, complete all as specified and directed by Engineer-in-Charge.

150

100

-

... More
Supply and fixing in replacement of copper pipe 3/8 inch outer diameter, conforming to IS 10773, complete all as specified and directed by Engineer-in-Charge.

40

53

-

... More
Supply and fixing in replacement of copper pipe 1/2 inch outer diameter, conforming to IS 10773, complete all as specified and directed by Engineer-in-Charge.

200

1

-

... More
Supply and fixing in replacement of copper pipe 1/4 inch outer diameter, conforming to IS 10773, complete all as specified and directed by Engineer-in-Charge.

200

-

-

... More
Supply and fixing in replacement of copper pipe insulation of any size, suitable for split/tower type air conditioner, complete all as specified and directed by Engineer-in-Charge.

350

100

-

... More
Material and labour for disconnecting and dismantling unserviceable compressor from split/window type air conditioner of capacity 1.5 TR and replacing with new hermetically sealed rotary compressor of the same capacity, refrigerant and electrical rating as the existing unit, on mountings such as rubber pads, nuts, bolts and washers, brazing suction and discharge lines properly, making electrical connections, checking for leakage at joints and vacuumising the system, complete all as specified and directed by Engineer-in-Charge. Note: The compressor shall carry a warranty of 12 months from the date of fixing and shall be replaced free of cost if found defective within that period.

34

53

-

... More
Description all as per item No. 43 above but rotary compressor for air conditioner of capacity 2.0 TR, 230 V, single phase.

15

10

-

... More
Description all as per item No. 43 above but scroll compressor for air conditioner of capacity 3.5 TR, 415 V, 50 Hz, three phase.

2

-

-

... More
Material and labour for transportation of air conditioner from site to workshop for detecting leakage in the closed circuit of window type air conditioner of capacity 1/1.5/2.0 TR, rectifying the leakage by brazing with copper rod using butane gas flame, vacuumising the system after rectification of leak, charging nitrogen and holding the pressure for not less than 24 hours or as directed, and refixing back in its original position at site, complete all as specified and directed by Engineer-in-Charge. Note: Cost of brazing rod, butane gas cartridge and nitrogen shall be included in the quoted rates.

50

100

-

... More
Material and labour for dismantling indoor unit of split type air conditioner of capacity 1.5/2 TR, transporting from site to workshop for detecting leakage in the closed circuit of the split type air conditioner, rectifying the leakage by brazing with copper rod using butane gas flame, vacuumising the system after rectification of leak, charging nitrogen and holding the pressure for not less than 24 hours or as directed, and refixing back in its original position at site, complete all as specified and directed by Engineer-in-Charge. Note: Cost of brazing rod, butane gas cartridge and nitrogen shall be included in the quoted rates.

100

53

-

... More
Material and labour for dismantling outdoor unit of split type air conditioner of capacity 1.5/2.0 TR, transporting from site to workshop for detecting leakage in the closed circuit of the split type air conditioner, rectifying the leakage by brazing with copper rod using butane gas flame, vacuumising the system after rectification of leak, charging nitrogen and holding the pressure for not less than 24 hours or as directed, and refixing back in its original position at site, complete all as specified and directed by Engineer-in-Charge. Note: Cost of brazing rod, butane gas cartridge and nitrogen shall be included in the quoted rates.

150

-

-

... More
Material and labour for detecting leakage in the closed circuit of tower type air conditioner of capacity 3.5 TR, rectifying the leakage by brazing with copper rod using butane gas flame, vacuumising the system after rectification of leak, charging nitrogen and holding the pressure for not less than 24 hours or as directed, and refixing back in its original position at site, complete all as specified and directed by Engineer-in-Charge.

3

100

-

... More
Material and labour for charging of refrigerant R-22 in window/split type air conditioner of capacity 1/1.5/2.0/3.5 TR after detection and rectification of leakage under relevant item of the schedule, including testing, complete all as specified and directed by Engineer-in-Charge. Note: Refrigerant under this item shall be the contractor's own supply and shall not be drawn from departmental store stock.

180

53

-

... More
Description all as per item No. 50 above but charging of refrigerant R-32.

180

10

-

... More
Description all as per item No. 50 above but charging of refrigerant R-410A.

45

-

-

... More
Supply only of refrigerant R-22 gas suitable for split/window type air conditioner, filled in empty cylinder at AGE E/M-III storeyard, complete all as specified and directed by Engineer-in-Charge. Notes: (i) Empty cylinder will be provided by the department for filling of refrigerant. (ii) Refrigerant purchase voucher shall be provided by the contractor. (iii) The refrigerant shall be taken on ledger charge with receipt voucher and issued as per requirement. (iv) The refrigerant supplied under this item is for use by departmental industrial staff only and shall not be issued back to the contractor.

120

100

-

... More
Description all as per item No. 53 above but refrigerant R-32.

120

53

-

... More
Description all as per item No. 53 above but refrigerant R-410A.

45

-

-

... More
Material and labour for disconnecting and dismantling blower/condenser fan motor of window type air conditioner of capacity 1.5/2.0 TR, transporting to civil workshop, rewinding with super enamelled copper conductor wire of superior quality, assembling with the air conditioner unit, testing and commissioning, complete all as specified and directed by Engineer-in-Charge.

30

100

-

... More
Description all as per item No. 56 above but motor of outdoor unit of split type air conditioner of capacity 1.5/2.0 TR.

50

53

-

... More
Description all as per item No. 56 above but motor of tower type air conditioner of capacity 3.5 TR.

3

10

-

... More
Supply and fixing in replacement of single phase electric motor, AC type, of indoor unit of split type air conditioner of capacity 1.5/2.0 TR, as per existing make and sample as per site requirement, complete all as specified and directed by Engineer-in-Charge. Note: The motor shall carry a warranty of 12 months from the date of fixing and shall be replaced free of cost if found defective within that period.

53

-

-

... More
Supply and fixing in replacement of single phase electric motor, DC type, of indoor unit of split type air conditioner of capacity 1.5/2.0 TR, as per existing make and sample as per site requirement, complete all as specified and directed by Engineer-in-Charge. Note: The motor shall carry a warranty of 12 months from the date of fixing and shall be replaced free of cost if found defective within that period.

50

100

-

... More
Material and labour for disconnecting leaking aluminium condenser coil from split type air conditioner of capacity 1.5/2.0 TR and supply and fixing of copper tube condenser coil of suitable size as per sample and make, fixing with the outdoor unit of the air conditioner, vacuumising the system and commissioning after fixing, complete all as specified and directed by Engineer-in-Charge.

10

53

-

... More
Supply and fixing in replacement of 20 A, 240 V, SPN industrial type socket outlet with 2 pole and earth, metal enclosed plug top, along with 20 A C curve SP MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet, complete with connections, testing and commissioning as required, complete all as specified and directed by Engineer-in-Charge.

40

-

-

... More
Material and labour in replacement of factory made MS angle iron stand of suitable size to mount outdoor unit of split type air conditioner of capacity 1.5/2.0 TR, complete all as specified and directed by Engineer-in-Charge.

80

100

-

... More
Supply and fixing of nylon braided PVC flexible drain pipe of size 15 mm as per sample, complete all as specified and directed by Engineer-in-Charge.

200

53

-

... More
Supply and fixing in replacement of PVC insulated and sheathed round multi-stranded copper conductor cable, 2.5 sqmm, 3 core, 1100 V grade, conforming to IS 694, complete all as specified and directed by Engineer-in-Charge.

300

10

-

... More
Supply and fixing in replacement of fan blade for window type air conditioner of capacity 1.5/2.0 TR as per existing make and sample, complete all as specified and directed by Engineer-in-Charge.

40

-

-

... More
Supply and fixing in replacement of condenser fan blade of outdoor unit of split type air conditioner of capacity 1.5/2.0 TR as per make and sample, complete all as specified and directed by Engineer-in-Charge.

70

100

-

... More
Material and labour for disconnecting burnt PCB from the unit and supply and fixing of new PCB of window type air conditioner of capacity 1.5/2.0 TR of any make/model, including testing and commissioning, complete all as specified and directed by Engineer-in-Charge. Note: The PCB shall carry a warranty of 12 months from the date of fixing and shall be replaced free of cost if found defective within that period.

18

53

-

... More
Material and labour for disconnecting burnt PCB from the unit and supply and fixing of new PCB of split type air conditioner of capacity 1.5/2.0 TR of any make/model, including testing and commissioning, complete all as specified and directed by Engineer-in-Charge. Note: The PCB shall carry a warranty of 12 months from the date of fixing and shall be replaced free of cost if found defective within that period.

30

-

-

... More
Material and labour for disconnecting burnt PCB from the unit and supply and fixing of new PCB of inverter type split air conditioner of capacity 1.5/2.0 TR of any make/model, including testing and commissioning, complete all as specified and directed by Engineer-in-Charge. Note: The PCB shall carry a warranty of 12 months from the date of fixing and shall be replaced free of cost if found defective within that period.

14

100

-

... More
Material and labour for disconnecting burnt PCB from the unit and supply and fixing of new PCB of tower type air conditioner of capacity 3.5 TR of any make/model, including testing and commissioning, complete all as specified and directed by Engineer-in-Charge. Note: The PCB shall carry a warranty of 12 months from the date of fixing and shall be replaced free of cost if found defective within that period.

3

53

-

... More
Supply and fixing in replacement of condenser fan motor including mounting base, rubber and clips, as per existing make and shaft length, in split type air conditioner of capacity 1.5/2.0 TR, complete all as specified and directed by Engineer-in-Charge. Note: The motor shall carry a warranty of 12 months from the date of fixing and shall be replaced free of cost if found defective within that period.

30

10

-

... More
Supply and fixing in replacement of swing motor of any type for split/window type air conditioner of capacity 1.5/2.0 TR, complete all as specified and directed by Engineer-in-Charge.

25

-

-

... More
Material and labour for rewinding burnt transformer of voltage stabilizer of capacity 5 kVA with super enamelled copper conductor winding wire and assembling with the stabilizer, complete all as specified and directed by Engineer-in-Charge.

60

100

-

... More
Supply and fixing in replacement of relay 30 A, 24 V coil, suitable for voltage stabilizer of capacity 5 kVA, complete all as specified and directed by Engineer-in-Charge.

40

53

-

... More
Supply and fixing in replacement of main PCB with high and low voltage cut off PCB, suitable for 5 kVA voltage stabilizer of the existing make, complete all as specified and directed by Engineer-in-Charge.

40

-

-

... More
Supply and fixing in replacement of window AC kit for 1.5 TR (with and including fans and compressor of approved make), complete all as specified and directed by Engineer-in-Charge. Note: The kit shall carry a warranty of 12 months from the date of fixing and shall be replaced free of cost if found defective within that period.

6

100

-

... More
Supply and fixing in replacement of split AC kit for indoor unit of capacity 1.5 TR (with all indoor accessories of approved make), complete all as specified and directed by Engineer-in-Charge. Note: The kit shall carry a warranty of 12 months from the date of fixing and shall be replaced free of cost if found defective within that period.

14

53

-

... More
Supply and fixing in replacement of split AC kit for outdoor unit of capacity 1.5 TR (with outdoor unit all accessories and including fans and compressor of approved make), complete all as specified and directed by Engineer-in-Charge. Note: The kit shall carry a warranty of 12 months from the date of fixing and shall be replaced free of cost if found defective within that period.

14

1

-

... More
Shifting of existing split type air conditioner of any capacity from one location to another location, complete, pumping down refrigerant gas into compressor, including disconnecting electrical/gas connections, making good disturbed surfaces in cement mortar 1:4 to match the existing, and installation by making necessary electric connections including brazing and refixing, complete all as specified and directed by Engineer-in-Charge.

50

-

-

... More
Material and labour for application of coil saver spray on copper pipe and condenser coil of window/split type air conditioner, complete all as specified and directed by Engineer-in-Charge.

200

100

-

... More
Supply and fixing in replacement of timer of tower type air conditioner, complete all as specified and directed by Engineer-in-Charge.

4

53

-

... More
Supply and fixing in replacement of new remote, complete all as specified and directed by Engineer-in-Charge.

40

10

-

... More
Supply and fixing in replacement of cooling coil sensor, complete all as specified and directed by Engineer-in-Charge.

20

-

-

... More
Supply and fixing in replacement of remote battery, complete all as specified and directed by Engineer-in-Charge.

200

100

-

... More
Material and labour for disconnecting water cooler of any size from main power and taking out for carrying out necessary repair/service/maintenance to check serviceability of compressor, fan motor, capacitor, thermostat, switches, gas leakage, push taps, fan blades, relays, overload protectors, condenser coils and any other spares required to make the water cooler functional, and fixing in original/existing position, complete all as specified and directed by Engineer-in-Charge.

10

53

-

... More
Supply and fixing in replacement of push cock of brass, chromium plated, 15 mm bore, complete all as specified and directed by Engineer-in-Charge.

5

-

-

... More
Supply and fixing in replacement of 15 mm bore PTMT float valve assembly with PVC float for water cooler, complete all as specified and directed by Engineer-in-Charge.

5

100

-

... More
Supply and fixing in replacement of combination relay unit complete, suitable for water cooler of 40 to 150 litres capacity, complete all as specified and directed by Engineer-in-Charge.

6

53

-

... More
Supply and fixing in replacement of condenser coil suitable for water cooler of 40 litres per hour cooling capacity and 80 litres storage capacity, as per existing size, complete all as specified and directed by Engineer-in-Charge.

1

10

-

... More
Supply and fixing in replacement of condenser coil suitable for water cooler of 60 litres per hour cooling capacity and 120 litres storage capacity, as per existing size, complete all as specified and directed by Engineer-in-Charge.

2

-

-

... More
Supply and fixing in replacement of thermostat switch suitable for water cooler, including knob plate and screw, complete all as specified and directed by Engineer-in-Charge.

5

100

-

... More
Supply and fixing in replacement of condenser fan motor of not less than 1/5 HP or as required, suitable for water cooler, complete all as specified and directed by Engineer-in-Charge.

5

53

-

... More
Material and labour for disconnecting old defective burnt sealed compressor unit of water cooler of 40 litres per hour cooling capacity and 80 litres storage capacity and replacing the same with new sealed compressor unit as per sample, including soldering of copper pipes, foundation rubber bushes, nuts and bolts and cleaning the refrigerant system, complete all as specified and directed by Engineer-in-Charge. Note: The compressor shall carry a warranty of 12 months from the date of fixing and shall be replaced free of cost if found defective within that period.

2

-

-

... More
Material and labour for disconnecting old defective burnt sealed compressor unit of water cooler of 60 litres per hour cooling capacity and 120 litres storage capacity and replacing the same with new sealed compressor unit as per sample, including soldering of copper pipes, foundation rubber bushes, nuts and bolts and cleaning the refrigerant system, complete all as specified and directed by Engineer-in-Charge. Note: The compressor shall carry a warranty of 12 months from the date of fixing and shall be replaced free of cost if found defective within that period.

2

100

-

... More
Material and labour for testing of water cooler, vacuumising properly, rectification of leakage in the entire system, making the gas system leak proof by brazing/welding and charging of refrigerant R-22, complete all as specified and directed by Engineer-in-Charge.

5

53

-

... More
Material and labour in replacement of factory made MS angle iron stand of suitable size to mount water cooler of any capacity, complete all as specified and directed by Engineer-in-Charge.

2

10

-

... More
Material and labour for disconnecting refrigerator from main power to carry out necessary servicing and check-ups to maintain efficient working throughout the season/year by checking and cleaning all parts, complete all as specified and directed by Engineer-in-Charge.

4

-

-

... More
Material and labour for disconnecting old defective burnt sealed compressor unit of refrigerator of 150 to 180 litres capacity of any make and replacing the same with new sealed compressor unit, including soldering of copper pipes, foundation rubber bushes, nuts and bolts, cleaning the refrigerant system and testing, complete all as specified and directed by Engineer-in-Charge. Note: The compressor shall carry a warranty of 12 months from the date of fixing and shall be replaced free of cost if found defective within that period. Make:

2

100

-

... More
Material and labour for cleaning the gas system along with rectification of leakage in the system of refrigerator of 165/190/290/310 litres capacity and charging of refrigerant R-134a, complete all as specified and directed by Engineer-in-Charge.

2

53

-

... More
Supply and fixing in replacement of DC freezer fan motor of refrigerator, suitable for any make and capacity, complete all as specified and directed by Engineer-in-Charge.

2

-

-

... More
Material and labour for disconnecting deep freezer from main power to carry out necessary servicing and check-ups to maintain efficient working throughout the season/year by checking and cleaning all parts, complete all as specified and directed by Engineer-in-Charge.

2

100

-

... More
Material and labour for disconnecting old defective burnt sealed compressor unit of deep freezer of 500 litres capacity of any make and replacing the same with new sealed compressor unit, including soldering of copper pipes, foundation rubber bushes, nuts and bolts, cleaning the refrigerant system, charging of refrigerant and testing, complete all as specified and directed by Engineer-in-Charge. Note: The compressor shall carry a warranty of 12 months from the date of fixing and shall be replaced free of cost if found defective within that period.

1

53

-

... More
Supply and fixing in replacement of starting relay assembly suitable for deep freezer of up to 500 litres capacity, complete all as specified and directed by Engineer-in-Charge.

1

10

-

... More
Supply and fixing in replacement of thermostat switch with defrosting arrangement suitable for deep freezer of up to 500 litres capacity, including knob plate and screw, complete all as specified and directed by Engineer-in-Charge.

2

-

-

... More
Supply and fixing in replacement of overload protector suitable for deep freezer, complete all as specified and directed by Engineer-in-Charge.

2

100

-

... More
Supply and fixing in replacement of condenser fan motor of not less than 12 W or as required, suitable for deep freezer, complete all as specified and directed by Engineer-in-Charge.

1

53

-

... More
Material and labour for cleaning the gas system of deep freezer of up to 500 litres capacity by flushing with dry nitrogen, vacuumising with vacuum pump, rectification of leakage in the system, fitting anti-moisture substance and filter, and charging of refrigerant R-134a or R-290 as per nameplate of the existing unit, complete all as specified and directed by Engineer-in-Charge.

1

-

-

... More
Material and labour for disconnecting industrial cooler from main power and taking out for carrying out necessary repair/service/maintenance to check serviceability of water pump, fan motor, capacitor, switches, cooler body and water distribution pipes of the cooler, removing existing paint/treatment completely, preparing the surface and applying externally two coats of synthetic enamel spray paint as approved over a coat of red oxide primer, shutters being painted all round externally and internally with one coat of synthetic enamel spray paint over a coat of red oxide primer, painting cooler body internally with one coat of bituminous paint, and refixing only serviceable motor, pump, PVC pipe, distributor and shutters in existing position, complete all as specified and directed by Engineer-in-Charge.

4

100

-

... More
Material and labour for disconnecting desert cooler from main power and taking out for carrying out necessary repair/service/maintenance to check serviceability of water pump, fan motor, capacitor, switches, cooler body and water distribution pipes of the desert cooler, removing existing paint/treatment completely, preparing the surface and applying externally two coats of synthetic enamel spray paint as approved over a coat of red oxide primer, shutters being painted all round externally and internally with one coat of synthetic enamel spray paint over a coat of red oxide primer, painting cooler body internally with one coat of bituminous paint, and refixing only serviceable motor, pump, PVC pipe, distributor and shutters in existing position, complete all as specified and directed by Engineer-in-Charge.

40

53

-

... More
Material and labour for rewinding fan motor of industrial cooler with suitable size of super enamelled copper wire, including replacement of bush and insulating material, greasing, testing and refixing after repair, complete all as specified and directed by Engineer-in-Charge.

2

10

-

... More
Material and labour for rewinding fan motor of desert cooler with suitable size of super enamelled copper wire, including replacement of bush and insulating material, greasing, testing and refixing after repair, complete all as specified and directed by Engineer-in-Charge.

14

-

-

... More
Supply and fixing of PVC flexible tubing, distributor and elbows for desert cooler, complete all as specified and directed by Engineer-in-Charge.

5

100

-

... More
Supply and fixing in replacement of submersible pump of desert cooler, single phase AC, 230 V, 50 Hz, including necessary connection and testing, complete all as specified and directed by Engineer-in-Charge. Make: POLAR/KHAITAN/GEC or equivalent approved by Engineer-in-Charge.

20

53

-

... More
Supply and fixing in replacement of rotary selector switch with 3 speed for desert cooler/industrial cooler, complete all as specified and directed by Engineer-in-Charge. Make: ANCHOR/AGI/DELITE or equivalent approved by Engineer-in-Charge.

5

-

-

... More
Supply and fixing in replacement of PVC sheathed 3 core cable with copper conductor of size 23/0.0076 for desert cooler, complete all as specified and directed by Engineer-in-Charge.

90

100

-

... More
Supply and fixing in replacement of new wood wool dry pads of suitable size as required for desert cooler, in set of three pads, of best quality as approved by Engineer-in-Charge, complete all as specified and directed by Engineer-in-Charge.

30

53

-



Evaluation Notes How It Works ?

Related Tenders

Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.