If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of etender.up.nic.in - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.

Military Engineer Services - MES Tender

Works
Civil And Construction
Drainage Work
Eprocure
Opening Date21 Apr 2025
Closing Date12 May 2025
Tender Amount₹ 48,52,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
M&L for 1.00 mm thick mild steel black sheet for manhole cover and similar works cut to size, holes punched including round headed screw / welding with bars etc complete as specified and as directed.

150

-

-

... More
S & F 110 mm bore PVC (SWR) bends of any radius complete all as specified & directed.

25

-

-

... More
M&L for reinforced concrete pipe of 300 mm bore, class NP 3 with one collar per lenth of pipe, laid in trenches and jointed in cm 1:1 complete all as specified and directed.

40

-

-

... More
M& L form work to sofits of suspended slabs such as roof slabs,floors slabs,landings/chajja and similar work not exceeding 200mm thick (horizontal or sloping) for fair finished surfaces of concrete required gap filler etc complete all as specified and directed.

15

-

-

... More
Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over 2 mm thick putty and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm on new surfaces complete all as specified and directed

20

-

-

... More
M&L, rendering 15 mm thick in CM 1:4 on surface other than fair faces of brick work or concrete surface and finishing surface even and smooth complete all as specified and directed.

300

-

-

... More
S&F clamps made out by 50 x 5 mm flat iron fixed with suitable bolt / screws securing ends of stays to wall or roof for PVC (SWR) / CI Pipe for 100 mm bore pipe complete all as specified & directed.

36

-

-

... More
Demolition and breaking up drain pipes (salt glazed ware, AC or reinforced concrete) set in cement mortar including concrete bedding and haunching complete all as specified and directed for upto 450 mm dia bore of pipe etc completed all as specified & directed.

90

-

-

... More
S&F TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips etc complete all as specified & directed.

3400

-

-

... More
S&F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted,or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 etc complete all as specified and directed.

250

-

-

... More
Excavation in trenches not exceeding 1.5 M wide and not exceeding 1.5 M in depth for foundation, manholes, etc n.exc 10 Sqm plan and getting out in soft/loose soil complete all as specified and directed.

50

-

-

... More
M&L for Cleaning/clearing of Drainage of any depth by removing any type of blockage from drain by rodding or any other means including dewatering if present etc complete all as specified and directed.

1000

-

-

... More
M&L for Providing cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate in roof kerbs or mud stops, haunching, benching slightly rounded or chamfered angles and throating as directed including necessary form work complete all as specified and directed.

20

-

-

... More
Supply only Integral waterproofing compound etc complete all as specified and directed.

50

-

-

... More
S&F in repair PVC (SWR) pipes 110 mm dia single socketed in any length with rubber ring joints laid in trenches or in floors etc complete all as specified and directed .

200

-

-

... More
M&L for reinforced concrete pipe of 200 mm bore, class NP 3 with one collar per lenth of pipe, laid in trenches and jointed in cm 1:1 complete all as specified and directed.

20

-

-

... More
Removing or dismantling of damage / cracked/ concrete /loose concrete / plaster of ceiling/ wall/ chajja/ facia to expose the sound and hard concrete using a suitable mechanical device or by hammer and chisels etc complete all as specified & directed.

10

-

-

... More
M&L for brick work with subclass B bricks old size straight or curved on plan exc 6 m mean radius built in cement mortar 1:6 complete all as specified and directed.

340

-

-

... More
M&L PCC 1:3:6 type C-2, using 40 mm graded stone aggregate as in bed of 200 mm bore reinforced cement concrete pipes including packing under and haunching against the sides of pipes after they are laid and tested complete all as specified and directed

16

-

-

... More
S&F in repair PVC (SWR) pipes 110 mm dia single socketed in any length with rubber ring joints fixed on wall etc complete all as specified and directed .

200

-

-

... More
All as per item no 8 above but except brick (using old brick)

30

-

-

... More
Taking up or down 20 mm bore steel tubing/ PPR pipe including fitting and connections, including cleaning for Refixing or removal to store complete all as specified and directed by the Engineer-in-charge.

50

-

-

... More
M&L for Cutting of road for repairing of existing drain and after repairing drain, road will be repaired by PCC 1:2:4 using 20 mm graded stone aggregate including necessary foam work etc complete all as specified and directed

1

-

-

... More
M&L PCC 1:3:6 type C-2, using 40 mm graded stone aggregate as in bed of 450 mm bore reinforced cement concrete pipes including packing under and haunching against the sides of pipes after they are laid and tested complete all as specified and directed

25

-

-

... More
M&L PCC 1:3:6 type C-2, using 40 mm graded stone aggregate as in bed of 300 mm bore reinforced cement concrete pipes including packing under and haunching against the sides of pipes after they are laid and tested complete all as specified and directed

35

-

-

... More
M&L for PCC 1:3:6 type B2 (using 40 mm graded Agg) as in surface channel and drains manhole etc all as specified and directed.

60

-

-

... More
M&L for two coats of oil bound distemper over a coat of average 2 mm thick putty on new plastered surfaces including preparation complete all as specified and directed.

20

-

-

... More
Demolition of Reinforcement Concrete of any description and in any position etc all as specified & directed.

26

-

-

... More
M&L for providing ready made reinforced cement concrete cover using M-25 Design mix concrete of size 1000 x 500 x 75 mm for cover slab of manhole, drain and similar articals with plane faces including minimum reinforcement 8 mm TMT bar at 150 mm c/c spacing complete all as specified and directed by engineer-in-charge.

100

-

-

... More
Taking down cement plaster on brick or stone walls, etc., including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified & directed.

150

-

-

... More
Fixing Only 20 mm bore Galvanized Steel tubes, medium grade with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed by the Engineer-in-charge.

10

-

-

... More
M&L for Providing and laying 60 mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footpath,parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand,compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete all as specified & directed.

166

-

-

... More
Demolition of brick work or stone/ boulder Masonry, built in cement mortar including all quoins, pillars etc including removal of spoil etc complete from drain. (No extra payment shall be claimed on this account)

350

-

-

... More
M&L, rendering 15 mm thick in CM 1:4 on fair faces of brick work or concrete surface and finishing surface even and smooth complete all as specified and directed.

1810

-

-

... More
M&L RCC M-25 (20 mm graded stone aggregate) as in slabs suppoorted on walls,beams and column in floors, roof, landings, balconies, canopies, deck slab and in shevels the like etc complete all as specified and directed.

4

-

-

... More
M&L for reinforced concrete pipe of 450 mm bore, class NP 3 with one collar per lenth of pipe, laid in trenches and jointed in cm 1:1 complete all as specified and directed.

30

-

-

... More
M&L providing precast cement concrete Type B1 1:2:4 (20mm graded aggregate) (nominal mix) for cover slab for manhole, drain and similar articals with plane faces complete all as specified and directed by engineer-in-charge.

26

-

-

... More
Removing of surplus soil excavated materials to a distance exceeding 50 M but not exc 100M and depositing where directed at a level not exceeding 1.5 M above the starting point complete all as specified and directed.

50

-

-

... More
M & L for applying bonding agent for bonding old to new concrete surface likes chajja/ beams/ celings/ columns/ facia etc by high performance modified Styrene- Butadiene Rubber ( SBR ) base binder . Applying of binder is as 10 sqm/ per lit etc complete all as specified & directed.

10

-

-

... More
Preparation of new steel surfaces of any description over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed

165

-

-

... More
S&F 20 mm bore Galvanized Steel tubes, medium grade with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed by the Engineer-in-charge.

40

-

-

... More
M&L for PCC 1:2:4 Type B1 ( using 20 mm graded stone aggregate), in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in eight, copings, kneelers, apex stones bed plates, kerbs chajjas , water troughs, bed blocks and the like including weathering, slightly rounded or chamfered angles and throating, fixing of chain link fencing etcall as directed incl necessary formwork etc complete all as specified and directed.

23

-

-

... More
M&L for 75 mm thick Cement concrete type D-2 1:4:8 (using 40 mm graded stone aggregate) in sub base of flooring/ hard standing finishing surface even and rough using broomfinish complete all as specified and directed.

166

-

-

... More
M&L for preparation of newly plastered surfaces of walls and applying three coat of white wash complete all as specified and directed.

1036

-

-

... More
M & L for applying 25 mm thick ( average ) repair mortar ready to use single component polymer modified repair mortar for repair of RCC members likes beams, columns, chajja and facia/Ceiling, mortar having good compressive strength and shrinkage resistance etc complete all as specified & directed.

10

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.