Military Engineer Services Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Military Engineer Services - MES Tender
Civil Works Others
Eprocure
Opening Date5 Sep 2024
Closing Date7 Jan 2025
Tender Amount₹ 54,37,20,000
Costs
EMD
₹ 15,00,000Document Cost
₹ 3,000Tender Fee
Refer Documents
Summary
Demolition And Reconstruction Of Single-entry Hardened Air Craft Shelters And Construction Of Two Single Entry Orp
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_671878_1Tender No
958119/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Lump sum price worked out by the contractor for Internal Water Supply as listed in Sch ‘A’ Part II.
1
-
36083.88
... More
Sch A Part III (INTERNAL ELECTRIFICATION)
-
-
-
... More
Lump sum price worked out by the contractor for Internal Electrification as listed in Sch ‘A’ Part III .
1
-
2258261.78
... More
Sch A Part IV (EXTERNAL ELECTRIFICATION)
-
-
-
... More
Lump sum price worked out by the contractor for External Electrification as listed in Sch ‘A’ Part IV.
1
-
3203843.48
... More
Sch A Part V (SEWAGE DISPOSAL)
-
-
-
... More
Lump sum price worked out by the contractor for Sewage Disposal as listed in Sch ‘A’ Part V.
1
-
97811.71
... More
Sch A Part VI (AREA DRAINAGE)
-
-
-
... More
Lump sum price worked out by the contractor for Area Drainage as listed in Sch ‘A’ Part VI
1
-
12206041.71
... More
Sch A Part VII STATIC WATER TANK
-
-
-
... More
Lump sum price worked out by the contractor for Road/Path & Culvert as listed in Sch ‘A’ Part VII
1
-
740597.21
... More
Sch A Part VIII RUNWAY/TAXI TRACK/PAVEMENT (NON-LOAD BEARING SURFACE)
-
-
-
... More
Lump sum price worked out by the contractor for Fencing and gate as listed in Sch ‘A’ Part VIII
1
-
4100945.65
... More
Sch A Part IX RUNWAY/TAXI TRACK/PAVEMENT (LOAD BEARING SURFACE)
-
-
-
... More
Lump sum price worked out by the contractor for Air conditioning and water cooler as listed in Sch ‘A’ Part IX
1
-
76804593.2
... More
Sch A Part X (LIGHTENING PROTECTION)
-
-
-
... More
Lump sum price worked out by the contractor for lightening protection as listed in Sch ‘A’ Part X
1
-
663960.2
... More
Sch A Part XI EXTERNAL WATER SUPPLY
-
-
-
... More
Lump sum price worked out by the contractor for cable duct as listed in Sch ‘A’ Part XI
1
-
67769.45
... More
Sch A Part XII ROAD/PATH/CULVERT
-
-
-
... More
Lump sum price worked out by the contractor for Earthwork as listed in Sch ‘A’ Part XII
1
-
19334192.78
... More
Sch A Part XIII DEMOLITION
-
-
-
... More
Lump sum price worked out by the contractor for Earthwork as listed in Sch ‘A’ Part XIII
1
-
3308010.59
... More
Sch A Part XIV AC and Refrigeration
-
-
-
... More
Lump sum price worked out by the contractor for Earthwork as listed in Sch ‘A’ Part XIV
1
-
1077609.48
... More
Sch A Part XV BARRICADING
-
-
-
... More
Lump sum price worked out by the contractor for Earthwork as listed in Sch ‘A’ Part XV
1
-
4914404.54
... More
Sch A Part XVI RAIN WATER HARVESTING
-
-
-
... More
Lump sum price worked out by the contractor for Earthwork as listed in Sch ‘A’ Part XVI
1
-
1328065.92
... More
Sch A Part XVII SITE CLEARANCE AND EARTHWORK
-
-
-
... More
Lump sum price worked out by the contractor for Earthwork as listed in Sch ‘A’ Part XVII
1
-
7986743.84
... More
Sch A Part XVIII (Miscellaneous Items of B/R and E/M)
-
-
-
... More
S&F sink mixer complete all as specified and directed.
2
-
-
... More
Suuply and fix LED High Bay Light Fitting 120 Watt IP 65 protection single phase 230 Volts AC complete all as specified and directed
20
-
-
... More
Supply and fixing MCCBs 63 Amps capacity, 415 volts, 4 pole, 25 KA, thermal magnetic complete all as specified and directed
2
-
-
... More
Supply and fixing MCCBs 40 Amps capacity, 415 volts, 4 pole, 25 KA, thermal magnetic complete all as specified and directed
2
-
-
... More
M&L for earthing complete with galvanized steel earth plate 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25 Mtr deep below normal ground level) with top edge of plate not less than 1.5 Mtr below normal ground level connected to earth lead wire of GI wire 4mm dia by means of nuts/bolts and washers, check nuts and washer of galvanized iron or steel including 15 mm dia GI pipe mediumt grade upto 1.5 mtr below ground level for protection pipe ,excavation and earth work charcole dust, common salt PCC 1:3:6 type C-I using 20 mm stone aggregate for chamber and MS angle iron frame 40x40x3mm and RCC cover 40 mm thick (1:2:4) type BI using 20 mm graded stone aggregate reinforced with 8 mm dia TMT bars @ 75 mm c/c both ways with MS handle 12 mm dia, round ,PGI funnel and wire mesh, 20 mm dia GI pipe light grade for watering all as shown in Plate no 3 of SSR Part I of 2009 and connected to earth test point incl testing complete all as specified and directed . Note :- Cost of earthing strip & GI pipe 25mm up to 7.5 m shall be included in cost of above item.
8
-
-
... More
M&L for Chemical Earthing by drilling a hole of 100 mm dia and 4 Mtr in depth in any kind of soil and providing a 3.0 mtr long pure copper strip of size 32mm x 6mm duly encapsuled in a medium grade Galvinized Steel pipe of size 88mm (OD) and filling the hole with advance non toxic earth enhancing backfill compound (qty not less than 30 Kgs) and water till complete soaking of Chemical- water mixture and providing a cylindrical type FRP earth pit chamber of size 254mm dia at top, 330mm dia at bottom and 260mm height and 7.50 Mtr long copper strip of size 32mm x 6mm as earth lead conductor duly protected with a 65mm bore medium grade GI pipe (from terminal point to earth test point) and duly connected with the terminal point through brazing and to connect with earth test point with brass bolts, nuts and washers of suitable size and fixed on the walls by mounting the strip on FRP / DMC Bridge insulators and providing a test point terminal block made of Gun Metal or Phosphorus Bronze of size 75mm x 75mm x 25mm, duly drilled and screwed and fixed on wall on insulators including 3 Nos 8mm dia 25mm long hex head brass screw complete with removing of excavated soil to a distance not exceeding 50 Mtr and at a height not exceeding 1.5 Mtr from the starting point and testing on completion all as specified and as directed.
Note : The additional length of earth lead conductor beyond 7.5 Mtr (if required at site) shall be measured and paid separately under the respective item mentioned here-in-under.
3
-
-
... More
M&L for earthing complete with Copper earth plate electrode 600mm x 600mm x 3.15mm thick buried directly in ground (earth pit not less than 2.25 Mts deep below ground level with top edge of the plate not less than 1.50 Mtrs below ground level connected to copper strip of size 32mm x 6mm by means of bolts, nuts check nuts and washers of brass connected to earthing test point all as specified incl 40 mm GI tubing medium grade and necessary fitting for protection of copper strip incl laying of charcoal dust and common salt in alternate layer, PCC Pit (1:3:6) type C-1 using 20 mm graded stone aggregate, RCC cover 40mm thick (1:2:4) type B-0 using 12.5mm graded stone aggregate reinforced with 6 mm dia round bar @ 75mm C/C both ways with MS handle 8mm dia, plastering 15mm thick CM (1:6) externally upto 150mm below ground level , GI funnel with 20mm dia medium grade GI pipe for watering and wire mesh incl excavation and earth work and disposal of surplus soil complete all as specified and shown on electrical plate No 3 of SSR Part (2009) and connected to earth test point incl testing and marking Bldg Nos and writing Test Results on a 3.0mm thick painted M.S. earth pit marking Plate (200mm x 100mm) duly welded with a 450mm long 10mm dia round M.S. rod, fixed with the earth pit chamber by grouting complete all as specified and directed.
7
-
-
... More
S&F RJ 11 Tele phone sockets SINGLE with transparrent shutter 1 module complete all as specified and directed
7
-
-
... More
M&L for earthing complete with galvanized steel earth plate 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25 Mtr deep below normal ground level) with top edge of plate not less than 1.5 Mtr below normal ground level connected to earth lead wire of GI wire 4mm dia by means of nuts/bolts and washers, check nuts and washer of galvanized iron or steel including 15 mm dia GI pipe mediumt grade upto 1.5 mtr below ground level for protection pipe ,excavation and earth work charcole dust, common salt PCC 1:3:6 type C-I using 20 mm stone aggregate for chamber and MS angle iron frame 40x40x3mm and RCC cover 40 mm thick (1:2:4) type BI using 20 mm graded stone aggregate reinforced with 8 mm dia TMT bars @ 75 mm c/c both ways with MS handle 12 mm dia, round ,PGI funnel and wire mesh, 20 mm dia GI pipe light grade for watering all as shown in Plate no 3 of SSR Part I of 2009 and connected to earth test point incl testing complete all as specified and directed . Note :- Cost of earthing strip & GI pipe 25mm up to 7.5 m shall be included in cost of above item.
8
-
-
... More
M&L for Chemical Earthing by drilling a hole of 100 mm dia and 4 Mtr in depth in any kind of soil and providing a 3.0 mtr long pure copper strip of size 32mm x 6mm duly encapsuled in a medium grade Galvinized Steel pipe of size 88mm (OD) and filling the hole with advance non toxic earth enhancing backfill compound (qty not less than 30 Kgs) and water till complete soaking of Chemical- water mixture and providing a cylindrical type FRP earth pit chamber of size 254mm dia at top, 330mm dia at bottom and 260mm height and 7.50 Mtr long copper strip of size 32mm x 6mm as earth lead conductor duly protected with a 65mm bore medium grade GI pipe (from terminal point to earth test point) and duly connected with the terminal point through brazing and to connect with earth test point with brass bolts, nuts and washers of suitable size and fixed on the walls by mounting the strip on FRP / DMC Bridge insulators and providing a test point terminal block made of Gun Metal or Phosphorus Bronze of size 75mm x 75mm x 25mm, duly drilled and screwed and fixed on wall on insulators including 3 Nos 8mm dia 25mm long hex head brass screw complete with removing of excavated soil to a distance not exceeding 50 Mtr and at a height not exceeding 1.5 Mtr from the starting point and testing on completion all as specified and as directed.
Note : (i) The additional length of earth lead conductor beyond 7.5 Mtr (if required at site) shall be measured and paid separately under the respective item mentioned here-in-under. (ii) Earth resistance should be maximum 3 ohm. In case the same is not likely to be achieved. The contractor will go for additional depth & soil treatment so as to achieve maximum 3 ohm resistance. Without any extra cost
4
-
-
... More
Supply and laying well burnt sub class ‘B’ bricks, locally best available laid in trenches for protection of underground cable complete all as specified and directed.
7200
-
-
... More
Supply, installation, testing and commissioning of 11 KV, 630 Amps, Extensible Outdoor Fixed Type (IP64), RMU (Ring main unit) 4-way comprising of 1 No 630 Amps, Motorised Load Break Switches (Comprising One No. Incomers) & 3 Nos. Vacuum Circuit Breaker as Outgoing, inside robotically / manually welded stainless steel (Non Ferrite Non Magnetic Grade) tank having min. thickness 2 mm having IP 67 Degree of Protection. RMU should be provided with Copper busbars internal, external as well as earthing busbars should be of copper, Resin cast ring core protection CT on cables 100/1 Amp, 5P10, 2.5 VA - 3 No's. & Resin cast ring core metering CT 50/1 Amp, Cl 1.0, 2.5 VA - 3 No's. on cables, one number fault passage indicator per unit, padlock provisions & complete with all accessories. The RMU shall be type tested for Internal arc test of 20kA/1 sec as per IEC62271-200. The unit shall include the following with all necessary standard fitting as required at site. (A) 1 No 630 Amp motorised Load Break Switches triple pole, single break 3 position as incomer (On, Off and earth having STC capacity 20 KA for 3 seconds with copper bus bar and copper earth bar fitted with fixed type voltage indicator device as per IEC 61958-1,fully rated with earth switch, spring assisted mechanism,Red/Green Push Button for On/Off Operation, Arc proof hinged type cable cover interlocked with Earth Switch, Air insulated cable boxes and boots suitable for bottom entry front termination of 3 core cable 95 Sqmm.
1
-
-
... More
(B) 3 Nos. 630 Amp Motorised Vacuum Circuit Breaker, triple pole, single break 3 position (On, Off and earth having STC capacity 20 KA for 3 seconds with copper bus bar and copper earth bar fitted with fixed type voltage indicator device as per IEC 61958-1, fully rated with earth switch, spring assisted mechanism, Red/Green Push Button for On/Off Operation, Arc proof hinged type cable cover interlocked with Earth Switch, Air insulated cable boxes and boots suitable for bottom entry front termination of 3 core cable 95 Sqmm. (C ) 3O/C + 1E/F self powered relay with Low and High set for Over current and Earth Fault. Relay should have LCD (16 x 2). Relay should have facility to trip the breaker from remote commands without shunt trip coil, Last 5 Fault Record with Time stamp, battery pack replaceable from front.
Transformer VCB should be provided with protection scheme for transformer faults like OTI, WTI & Buchholz's relay alaram & trip, along with annunciation & lock-out function Bus Connected PT Unit -1 No. for Metering consisting of following:-
-
-
-
... More
(i) Type M: Air Insulated metering module 12KV, 630A, 20KA for 3sec.
(ii) 3 Voltage Transformers of the ratio 11kV/√3 / 110 V/√3, 25 VA, Class 1 with HT fuses on primary side and MCB on secondary side.
(iii) 1 Digital MFM to measure Amps,Volts,Frequency,PF,KWH,KVAR.
(iii) 1 LED Illumination.
(iv) 1 Space Heater with thermostat.
(v) 1 RYB phase indications.
(vi) 1 set Bushings for external busbar connection along with Busbar cover & Sleeved busbars for coupling. (vii) 2x12 V Battery with battery charger with suitable burden for motor operation. Input 230 V AC & Output 24 V DC. Battery make: EXIDE/HBL.
(D) LED based Capacitive voltage indication fixed type VPIS 9-15 kV
Necessay interclocking arrangement for safety and operations
LBS shall be of ratings 12 KV, 630 A, 20 KA for 3 Sec.
(E) One No. Operationg Handle for Manual Operation.
(F) One No. Manometer.
(G) Safety Interlocks Shall be provided as per relevant IEC/IS Standards and Manufacturers directions.
(H) Above switchgear shall confirm to all relevant IEC/IS Standards.
(I) Manual operation of Load Break switch should be possible without dismantling the motor from RMU. The motor should be fitted in such a way that it should not be outside front covers of RMU. Coupling of RMU and Metering module should be with the help of Bolted type arrangement, so that the coupling at site shall be easy. Plug-in type bushing shall not be acceptable.
(J) The Cable termination of RMU should be rear accessible only. And minimum 3 module should accommodate in one tank to avoid multiple coupling at site
(K) PCC 1:2:4. type B1 using 20 mm graded aggregate for foundation of RMU as per recommendations of manufacturers of directed by EIC.
Note (i) Any other parts/items not specified above but have been required essential for smooth and safe functioning of the RMU system shall be quoted rate.Make: AREVA/ L&T/SIEMENS/SCHNEIDER
(ii) The RMU will be tested at site by primary injection test system and submit the test report.
-
-
-
... More
Shifting of transformer HT 11 KV, three phase, LT 433 volt ,capacity up to 100 KVA using man power /crane/transport vehicle to required location within AF Stn BKT incluiding re-installation at new location & making all HT/LT connection & Earthings connection, testing and re-commissioning of the transformer including any other requirement for smooth funtioning to restore the electric supply complete all as sepecified and directed.
Notes:-
(i)For shifting of transformer from existing location to new location shall be required mechanical instrument such as crane & vechicles including loading/unloadingetc. Cost will be bear by bidder and shall be deemed included in the unit quoted rate ,no any claim entertained on this account at later stage
1
-
-
... More
M & L for horizontal boring under PTT/Runway / Road, pavement, Hard standing complete by trenchless technology using ultra sound technique and necessary machine including HDPE PN-10 pipe of 150 mm dia suitable for 0.4 Mpa working pressure complete all as sepecified and directed.
20
-
-
... More
Supply and fix steel tubular swaged poles type 410 SP-22 (8.5 meter long) complete with CI base plate and foundation, coping complete all as specified and directed.
15
-
-
... More
S&F 3 core PVC insulated flexible cable cord 1.5 sqmm multi stranded copper conductor flexible cables 1100 Volt grade complete and making connection from pole box to Flood light complete all as sepecified and directed.
150
-
-
... More
S&F Weather Proof thermo plastic (Polysterene) Cable Junction box, having protection class IP-66 and of overall size 155mm x 210mm x 92mm (Approx) having metric knockouts on the wall, duly fixed with the pole with aluminium strip (25x3mm) clamp, GI bolts, nuts, washers and 2 Nos polymide weather proof cable glands of cable sealing range 10mm to 17mm (Complete with check nut) and including 1 No 30 Amps 4 Way cable connector and 1 No. 6 Amps SP MCB complete all as sepecified and directed.
16
-
-
... More
Design, supply, erection, testing and commissioning of outdoor type LT Feeder Pillar of overall size not less than 1000mm Height (Without Canopy & Base Channel) 1400mm width x 450mm Depth, M.S. Channel Base Frame mounted (to be mounted on the 3 side covered brick/PCC. pedestal of height 750 mm above ground level) , suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos Aluminium bus bars of rating 600 amps, Provision of Spreader link to both incoming and outgoing side of MCCBs for termination of cables. The Feeder Pillar shall be duly fabricated in a approved / certified factory / fabrication house who posseses type test certificate from CPRI for similar type of Feeder Pillar and having modern fabrication and testing facility which includes atleast seven (07) tanks pre-treatment facility comprising of de-greasing, rinsing, de-rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting with approved shade of RAL 7032 (SIEMENS GRAY). The Feeder Pillar shall be provided with suitable rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-54 and general construction conforming to IS : 13947. The feeder pillar shall be made out of 3.15mm thick CRCA Stainless steel sheet for outer sheet and 2.0mm thick for inner doors/partations and 3.15mm thick gland plate and having compartmentalized construction for individual switchgears and Bus Bars and having front opening facility (with double layer shutter) and rear opening facility with single layer shutter with locking facility and 2 side slanting canopy type roof on top and mild steel channel (MC-75) base frame at bottom, suitable for mounting on the brick pedestal through grouting bolt, The panel board shall be provided with ventilation facility in the form of louvers for better heat dissipation. The feeder pillar shall be comprising of the followings :-
1
-
-
... More
PROVISION FOR CABLE ENTRY :- The provision for cable entry / exit shall be provided from the bottom for both incoming and outgoing cables. BUS BARS & INTERNAL CONNECTIONS :- The bus bars should be made of Aluminium, duly insulated with 1100 volts grade standard colour coded heat shrink type PVC sleeves and rigidly mounted on suitable size 'F' class insulators of non hygroscopic non combustable, track resistant,high strength FRP / SMC / DMC material. 4 Nos Aluminium bus bars of rating 300 amps, . For all internal connections from main bus bars to switch gears shall be carried out with suitable size PVC insulated aluminium strip as per the current carrying capacity of individual switch gears. Earthing bar shall be provided as per standard practice and shall be made of Galvanized Steel flats of size 25mm x 6 mm
CONTROL WIRING :- All control wirings shall have to be carried out with 1100 volts rated FRLSH grade PVC insulated (Gray Colour) multi-flexible type copper wire of cross sectional area 1.50 Sq mm and shall be properly bunched,tied and dressed, ferrule marked for proper identification and crimped with suitable size & type of tinned copper lugs and shall be wrapped with PVC spring type flexible pipes near the door hinges.
-
-
-
... More
INCOMING :- (i) MCCB 250 Amps (16 KA) 4 Pole Adjustabble thermal (80% to 100%) and fixed magnetic protection -01 No (For Blast pen).
OUTGOINGS :-
(i) MCCB 100 Amps (16 KA) 4 PoleAdjustabble thermal (80% to 100%) and fixed magnetic protection - 04 Nos (For Blast pen)) (ii) MCCB 63 Amps (16 KA) 4 Pole 4 PoleAdjustabble thermal (80% to 100%) and fixed magnetic protection -03 Nos (For annexe). (iii) MCB SPN 32 Amps B series 10 KA -02 Nos(Garrage)
(iii) Street Light Controller : (a) 2 Pole MCB 6 Amps (10 KA) - 01 Nos (b) Dial type DIN rail mounting, Analog Time Switch 16 Amps / 230 Volts AC 50Hz, with battery back up, 24 Hrs programmable type with 1 NO & 1 NC output contact.- 01 No. (c) Modular type DIN rail mounted 2 pole power contactor having 2 Nos "NO" contact of rating 25 Amps complete with 230 v0lt AC coil - 01 No. (d) 2 way Toggle switch (6 amps) for Auto / Manual operation - 01 No.
-
-
-
... More
MISCELLANEOUS ITEMS :- (a) SP MCB 3 Amps 10 KA (For Control Wiring) - 03Nos. INSTRUMENTATION SYSTEM :-
a) LED Phase Indicating light, shrouded type, 22mm, with cluster LED - 01 set of 3 lamps (RED,YELLOW & BLUE)
b) Digital Volt Meter 0-500 Volts (96mm x 96mm), 4 1/2 digit,Accuracy Class 1% - 01 No.
c) Digital Ammeter 0-500 Volts (96mm x 96mm), 4 1/2 digit,Accuracy Class 1% - 01 N0
d) C.T. having Ratio 250/5, tape wound,BPL, rated burden 15 VA - 03 Nos. (e) Volt meter selector switch (6 Amps), 3 position with "OFF" - 01 No.
f) Ammeter selector switch (6 Amps), 3 position with "OFF" - 01 No.
g) Danger Notice Plate duly written in Signal Red colour on Aluminium plate in English & Hindi language and of size not less than 150mm x 100mm - 02 Nos.
-
-
-
... More
Note :
All incoming & outgoing feeders to be marked with aluminium name plates duly rivetted on the front inner door of the feeder pillar.
(2) All the cable entry / exit will be through bottom only, duly glanded with single compression type brass cable gland of suitable size. Cost of end termination of cable shall deemed to be included in the cost of feeder pillar.
(3) All the inner / outer doors should have locking facility through castle locks
(4) Cost of all civil work for brick pedestal, duly plastered, shall deemed to be included in the unit rate quoted, no separate payment shall be allowed for this.
(5) The dimention of Panel Board as mentioned above is tentative. If it is required to be enhanced to accomodate the switchgears and maintaining the gaps as per IE Rules, it should be enhanced as per requirement without any extra cost to the department.
(6)The thickness of MS Sheet for outer shell and canopy shall be of 3.15mm and inner doors and partitions shall be of 2.0 mm
(7) The Panel Board should be designed in such a way that adequete workable space is made available inside every compartments.
(8) The drawing of the Panel Board shall have to be got approved by Garrison Engineer before starting of fabrication process.
Note:- 1) All incoming & outgoing feeders to be marked with aluminium name plates duly rivetted on the front inner door of the feeder pillar.
2) All the cable entry / exit will be through bottom only, duly glanded with single compression type brass cable gland of suitable size. Cost of end termination of cable shall deemed to be included in the cost of feeder pillar.
3) All the inner / outer doors should have locking facility through castle locks
4) Cost of all civil work for brick pedestal, duly plastered, shall deemed to be included in the unit rate quoted, no separate payment shall be allowed for this. 5) The dimention of Panel Board as mentioned above is tentative. If it is required to be enhanced to accomodate the switchgears and maintaining the gaps as per IE Rules, it should be enhanced as per requirement without any extra cost to the department.
6)The thickness of MS Sheet for outer shell and canopy shall be of 3.0mm and inner doors and partitions shall be of 2.0 mm
7) The Panel Board should be designed in such a way that adequete workable space is made available inside every compartments.
8) The drawing of the Panel Board shall have to be got approved by Garrison Engineer before starting of fabrication process.
-
-
-
... More
M & L for earthing complete with Galvanised steel earth plate 600 mm x 600 mm x 6.00mm thick buried directly in ground vertically in pit of depth not less than 2.25 mtr below normal ground level with top edge of the earth plate not less than 1.50 mtr below normal ground level connected to contineous (without joint) galvanised strip 32 x 6 mm as earthing by means of bolts, nuts, check nuts and washers of brass connected including gun metal or phosphorus bronze of size 75 mm x75 mm x 25 mm drilled and screwed including 3 Nos 8 mm dia 25 mm long hexagonal head screwed all as specified including excavation and earth work and disposal of surplus soil including 15 mm bore Gl tubing medium grade and necessary fitting for protection of Gl wire including laying of charcoal, dust and common salt PCC 1:3:6 type C-1( using 20 mm graded crushed black trap/ granite/ Basalt stone aggregate), 40 mm thick pre-cast cover reinforced cement concrete with 8 mm dia TMT bars@ 75 mm c/c both way with 12 mm dia round bar as handle, GI medium grade watering pipe 20 mm dia with funnel and wire mesh, 15mm thick rendering in cement mortar 1:4 internally and upto 150mm below ground level & externally. PGI funnel with wire mesh , complete all as shown on electrical plate No.3 of SSR Part -1( 2009) and connected in earth test including testing complete all specified and directed. NOTE :- (i) The rates quoted shall also deemed to include the cost of Earth test point and earth wire and protection pipe upto 7.5 metre beyond the earth plates electrode and the earth resistance of the whole system shall be as near as possible to 0 but shall not in any case exced one ohm.
16
-
-
... More
Dismantaling of Existing serviciable DG Set of capacity 100/125 KVA including Disconnectiong electric connection from Alternator & body and shifting safely at a distance not excceding 3-4 KM (Appx) at new loction within af Stn BKT and making electric connection complete all as specified and as directed.
1
-
-
... More
M&L Construction of septic tank for 50 users including necessary earth work in excavation in any type of soil, plain concrete 1:2:4 type b2 (using 40mm graded crushed aggregate ) as in foundation brick work in cement mortar 1:4 , reinforced cement concrete in M-25 (Design Mix) as in slab cover including pre-cast manhole cover slab having 8mm TMT bar reinforcement @75mm c/c & 6mm thick mild steel plate embedded all around of cover slabb, 15mm thick plaster in cement sand mortar in 1:4 on wall, vent shaft, sludge chamber , form work to sides and soffits, CI vent pipe, sludge chamber RCC baffle wall returning filling and removal etc complete all as shown on drawings & as specified. TD No- 217 sheet No- 1/2 & 2/2 complete all as specified and directed.
1
-
-
... More
M&L for construction of Soakage well for 2.40 m internal dia and 4.5m (effective depth) including necessary excavation in earth work in any type of soil, plain cement concrete 1:3:6 type C-2 (using 40mm graded curshed stone aggregate) as in foundation, brick work in cment mortar 1:4 in walls and honey combed brick wall, reinforced cement concrete M-25 (design mix) as in slab cover including pre-cast cover slab having 8mm dia TMT bar reinforced plain cment concrete band and dwarf wall , form work to sides and soffits of RCC slab & filling with brick bats loose filling complete all as specified and shown in drawings TD No- 576 sheet No- 1/2 & 2/2 complete all as specified and directed.
1
-
-
... More
M & L for earthing complete with copper plate 60×60cm ×3.15mm thick electrode and 20×6mm copper strip as earthing lead buried directly in ground (earth pit not less than 2.25 Mtr deep below normal ground level) with top edge of plate not less than 1.5 Mtr below normal ground level connected to 20×3mm copper strip as earthing lead by means of nuts/bolts and washers, check nuts and washer of galvanized iron or steel including 40 mm dia GI pipe light grade upto 1.5 mtr below ground level for protection pipe ,excavation and earth work charcole dust, common salt PCC 1:3:6 type C-I using 20 mm stone aggregate for chamber and MS angle iron frame 40x40x3mm and RCC cover 40 mm thick (1:2:4) type BI using 20 mm graded stone aggregate reinforced with 8 mm dia TMT bars @ 75 mm c/c both ways with MS handle 12 mm dia, round ,PGI funnel and wire mesh, 20 mm dia GI pipe light grade for watering all as shown in Plate no 3 of SSR Part I of 2009 and connected to earth test point incl testing complete all as specified and directed . Note :- (i) Cost of earthing strip & GI pipe 25mm up to 7.5 m shall be included in cost of above item.
(ii) Excavation and earthwork in any type of soil strata shall be deemed to be included in the rates quoted.
(iii) The Steel work, RCC , PCC work shall be deemed to be included in the rates quoted.
16
-
-
... More
Taking down of GI pipes 80 mm dia with all fittings laid in trenches complete all as specified and as directed.
30
-
-
... More
Material and Labour for cutting of existing GI pipe 80 mm bore and inserting TEE 80 x 80 x 40 mm with all connected accessories Complete all as specified and directed.
1
-
-
... More
Supply and fixing gun metal gate valve ISI marked cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for union and fixed complete all as specified for the size 80 mm dia bore complete all as specified and directed.
1
-
-
... More
M & L Boring of holes under PTT/Runway, road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 100 mm dia suitable for 0.4 mpa working pressure complete all as specified and directed.
20
-
-
... More
M&L for construction of brick masonry valve pit of size 1050 X 1050 X 1050 mm (Internal dimensions) with brick work of old size fly ash bricks built in cement mortar 1:4 and 10 mm thick rendering on internal and 15 mm thick on exposed external surfaces in cement mortar 1:4, 40 mm X 40 mm X 6 mm mild steel angle iron frame, 3.00 mm thick mild steel sheet cover with appropriate size lifting handles and locking arrangement and 01 No. 50 mm size 4 levers lock with keys in duplicate including painting steel and iron surfaces with two coats of black bituminous paint over a coat of red oxide primer complete all as specified and as directed.
2
-
-
... More
Supply & Fix electronic wall mounted digital display (Input & output) voltage stabilizer for automatic voltage correction single phase, naturally air cooled, indoor type, designed for input voltage between 140 Volt to 280 Volts and out put voltage 230 Volt and High/ Low voltage cut off with facility of including instant start & time delay relay of 3 minute capacity 4 KVA.
4
-
-
... More
Supply & Fix electronic wall mounted digital display (Input & output) voltage stabilizer for automatic voltage correction single phase, naturally air cooled, indoor type, designed for input voltage between 140 Volt to 280 Volts and out put voltage 230 Volt and High/ Low voltage cut off with facility of including instant start & time delay relay of 3 minute capacity 5 KVA.
8
-
-
... More
S & F socket outlet 5 pin 20 Amps modular type, 2 module with suitable size of module metal flux boxes and including modular front cover plate and back plate for mounting modular type switch & socket with one single pole modular type MCB of capacity 20 amps (1 module) including electrical connection all as specified and directed.
12
-
-
... More
S&F PVC casing pipe 250 mm dia bore medium grade 6 KG/sqcm, ISI marked, plain with bail plug at the bottom of each bore complete all as specified and as directed
132
-
-
... More
All as per item No. 17.38 above but slotted pipe complete all as specified and directed
312
-
-
... More
M&L for drilling 200mm dia bore holes by DHT cum rotary method at any depth as in any type of soil maximum upto 40mtr depth from natural ground level and including removal of surplus soil to a distance n. exc 50m complete all as specified and directed
132
-
-
... More
Taking out unsv old HT cable of any type and of size from 95 sqmm from existing trenches/ floor/road/wall of any size for relaying and refilling the excaated trench complete all as specified & directed.
380
-
-
... More
Laying of old bricks/pre cast PCC cover,as obtained from item No. 17.42 Above old size well burnt laid flat dry for protection of underground cable complete all as specified and directed
680
-
-
... More
M&L complete for boring of holes under road ,pavement,hard standing by trenchless technology using ultrasound technique and necessary machinery including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all as specified and directed
50
-
-
... More
M&L for drilling suitable dia horizontal bore holes for insertion/ laying of 80 mm bore GI tubing of any description below/under existing road surfaces / apron /floors etc with using mechanical and / or manual devices as required at site including making good the disturbed surfaces to match with the existing streta after laying pipes complete all as specified and directed.
20
-
-
... More
Relaying of cable XLPE insulated , armoured heavy duty electric cable with alumnium conductor ,11000 volts grade of,size 95 sqmm 3 core complete all as specified and directed .
380
-
-
... More
Supply, installation , testing and commissioning factory made LT feeder pillar box outdoor type platform mounted suitable for 415 Volts 3 phase 4 wire system 50Hz supply having aluminium bus bar 400 Amps for phases and neutral, fixed on porcelain / epoxy insulator. the panel shall be dust proof, vermin proof (IP54) and applying spray painting with two coats of synthetic enamelled paint over a coat of red oxide primer on sheet and made of out of 3.15 mm thick CRCA sheet self moulded type and 50x50x6 mm angle iron frame front and rear opening with double shutter and locking arrangement with 50mm lock and including grouting of panel with necessary PCC 1:2:4 type B-1 work complete all as specified. The scope of work includes provision of housing the following accessories:-
2
-
-
... More
Incoming :- (i) MCCB having current rating 63 Amp. 4 pole of breaking capacity 16 KA -01 No.
(ii) Volt meter 0-500 Volts,Square flush pattern, 96x96 mm digital type -01 No.
(iii) Amp meter square flush pattern,96mm x 96mm 0-600 Amps digital type-01 No.
(iv) Indicating lamp LED type one set in incoming phases.
(v) Internal wiring with PVC insulated copper conductor multi stranded cable 1100 volts grade IS 694 marked .
Outgoing :-
(i) MCCB having current rating 63 Amp, 4 pole, of breaking capacity 16 KA, 415 volts -01 Nos. (ii) MCB spn 16 Amp 2 Pole -01 Nos
-
-
-
... More
M& L for Earthing complete with steel earth plate electrode 60cm x 60cmx6 mm thick burried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to GI earth strip of size 32x6 mm by means of bolts, nuts, check nuts and washers of brass all as shown in electrical plate No 3 of MES Schedule Part-I including and connecting to panel and testing on completion with and including 50 mm bore light grade G.I. protection pipe (upto 7.5 M beyond outer edge of earth pit) PCC base 1:4:8 type using 40 mm agregrate of size 750x750x100 mm thick with precast RCC cover 40 mm thick in PCC 1:3:6 type B1 using 20 mm graded stone aggregrate with 8 mm dia TMT bars 3 nos both ways with 12 mm dia round handle , PGI funnel with wire mesh, 20 mm dia GI pipe light grade for watering all as shown in electrical plate no 3 of SSR Part no 1 of 2009 complete all as specified and directed.
4
-
-
... More
Supply, fixing, light bracket on pole fabricated /made of GI pipe 40 mm dia 1.20 mtr long bend to shape with and including MS clamps 40 mm with nut bolt and washer complete all as specified and directed.
6
-
-
... More
S&F Weather Proof thermo plastic (Polysterene) Cable Junction box, having protection class IP-66 and of overall size 155mm x 210mm x 92mm (Approx) having metric knockouts on the wall, duly fixed with the pole with aluminium strip (25x3mm) clamp, GI bolts, nuts, washers and 2 Nos polymide weather proof cable glands of cable sealing range 10mm to 17mm (Complete with check nut) and including 1 No 30 Amps 4 Way cable connector and 1 No. 6 Amps SP MCB complete all as specified and directed.
6
-
-
... More
Supply and fix flush mounted factory made VTPN DBs, 415 volt IP - 43 protection IK-09 with metal double door with 200 Amp copper bus bar with 2 neutral bar, earth bar and cables management fully insulated bus bar with set of wire and door earthing with provision of space of 100 amps MCB as incomer and SP/TP MCBs as outgoing 4 way complete all as specified and as directed.
2
-
-
... More
Supply & Fix PCC block of size 300mm X 300mm complete all as specified and directed.
40
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%